Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polymer solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Autonomous platform for solution processing of electronic polymers

The manipulation of electronic polymers’ solid-state properties through processing is crucial in electronics and energy research. Yet, efficiently processing electronic polymer solutions into thin films with specific properties remains a formidable challenge. We introduce Polybot, an artificial intelligence (AI) driven automated material laboratory designed to autonomously explore processing pathways for achieving high-conductivity, low-defect electronic polymers films. Leveraging importance-guided Bayesian optimization, Polybot efficiently navigates a complex 7-dimensional processing space. In particular, the automated workflow and algorithms effectively explore the search space, mitigate biases, employ statistical methods to ensure data repeatability, and concurrently optimize multiple objectives with precision. The experimental campaign yields scale-up fabrication recipes, producing transparent conductive thin films with averaged conductivity exceeding 4500 S/cm. Feature importance analysis and morphological characterizations reveal key design factors. This work signifies a significant step towards transforming the manufacturing of electronic polymers, highlighting the potential of AI-driven automation in material science.

Wang, Chengshi [Argonne National Laboratory (ANL),↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

Data-Driven Discovery and Experimental Validation of Solvent Polarity Effects on Conjugated Polymer Solution-to-Film Assembly Pathways

Understanding how solvent properties influence the solution-to-film assembly of conjugated polymers remains a critical challenge due to the complex and intertwined nature of polymer–solvent interactions. In this study, we integrate a data-driven framework with experimental validation to identify key parameters influencing the assembly and performance of poly[2,5-(2-octyldodecyl)-3,6-diketopyrrolopyrrole-alt-5,5-(2,5-di(thien-2-yl)thieno[3,2-b]thiophene)] (DPP-DTT) in organic field-effect transistors (OFETs). A machine learning (ML) approach identified the normalized Reichardt polarity parameter (E T N ) as a significant descriptor correlated with DPP-DTT hole mobility (μ). Systematic DPP-DTT devices fabricated using solvents across a wide E T N range revealed that higher E T N solvents yield enhanced μ. To elucidate the structural origins of high μ, we conducted comprehensive analyses using UV–vis–NIR spectroscopy and grazing incidence wide angle X-ray scattering (GIWAXS) measurements. The results revealed that films processed from high E T N solvents exhibit reduced paracrystallinity. By analyzing the solution-state behavior using optical microscopy and solution WAXS, we revealed polymer solubility differences in the various solvents and associated distinct polymer assembly pathways, elucidating why the high E T N solvent produces long-range ordered films. Notably, the high E T N solvent shows a pronounced preference for liquid-crystal (LC)-mediated assembly, providing a mechanistic explanation for the enhanced structural order. Therefore, these results demonstrate that solvent polarity, as evaluated by E T N , serves as an important parameter that plays a significant role in the DPP-DTT assembly pathway and resultant solid-state morphology. This work provides a strategy for integrating data science with experiments to identify critical parameters associated with complex polymer systems and helps guide rational process design for high-performance organic electronics.

36 MATERIALS SCIENCE↗

Upper critical solution temperature polymer assemblies via variable temperature liquid phase transmission electron microscopy and liquid resonant soft X-ray scattering

Abstract Here, we study the upper critical solution temperature triggered phase transition of thermally responsive poly(ethylene glycol)- block -poly(ethylene glycol) methyl ether acrylate- co -poly(ethylene glycol) phenyl ether acrylate- block -polystyrene nanoassemblies in isopropanol. To gain mechanistic insight into the organic solution-phase dynamics of the upper critical solution temperature polymer, we leverage variable temperature liquid-cell transmission electron microscopy correlated with variable temperature liquid resonant soft X-ray scattering. Heating above the upper critical solution temperature triggers a reduction in particle size and a morphological transition from a spherical core shell particle with a complex, multiphase core to a micelle with a uniform core and Gaussian polymer chains attached to the surface. These correlated solution phase methods, coupled with mass spectral validation and modeling, provide unique insight into these thermoresponsive materials. Moreover, we detail a generalizable workflow for studying complex, solution-phase nanomaterials via correlative methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of Bottlebrush Polymers in Solution by Neutron Spin Echo Spectroscopy

In this work, we present dynamical and morphological studies on poly(dimethylsiloxane) (PDMS)-based bottlebrush polymers in solution. A combination of small-angle neutron scattering (SANS), pulsed field gradient nuclear magnetic resonance (PFG NMR), and neutron spin echo (NSE) spectroscopy was used to identify structural changes inherent in changing the side-chain length while keeping the backbone constant. These morphological changes are mirrored in the diffusion coefficient determined by PFG NMR, resulting in two coefficients for the elongated and one for the more spherical sample. Faster motions are tracked by NSE using the advantage of time- and length-scale resolutions with the diffusion coefficient predetermined by PFG NMR. Hereby, the sample with short side chains relaxes like wormlike micelles considering the longitudinal direction, whereas the dynamics along the radial extension shows a much stronger Q-dependence as known from any theory. The dynamical behavior within the blob region, covered with the more spherical sample, follows the predictions of Zimm as well as of Zilman and Granek (ZG).

36 MATERIALS SCIENCE↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Thermally-rearranged polymer blends for gas separation membranes

Polymer blends comprising an ortho-functionalized polyimide homo or copolymer and a polybenzimidazole homo or copolymer, wherein the ortho-functionalized polyimide thermally rearranges to a polymer comprising a phenylene heterocyclic group, such as, polybenzoxazole, polybenzothiazole, polybenzimidazole and/or other heterocyclic structure upon heating. Also disclosed are method of forming a polymer blend comprising dissolving an ortho-functionalized polyimide homo or copolymer and a polybenzimidazole homo or copolymer in a solvent, and optional compatibilizer, to form a polymer solution; contacting a support with the polymer solution; and evaporating the solvent to provide a thin layer comprising the polymer blend on the support. Further, methods of heat treating these polymer blends to thermally rearrange the disclosed polyimides are disclosed, as are the polymer blends prepared thereby. Methods of using these polymer blends to separate gases are also disclosed.

Freeman, Benny D.↗

Ion Exchange Gels Allow Organic Electrochemical Transistor Operation with Hydrophobic Polymers in Aqueous Solution

Conjugated-polymer-based organic electrochemical transistors (OECTs) are being studied for applications ranging from biochemical sensing to neural interfaces. While new polymers that interface digital electronics with the aqueous chemistry of life are being developed, the majority of high-performance organic transistor materials are poor at transporting biologically relevant ions. Here, the operating mode of an organic transistor is changed from that of an electrolyte-gated organic field-effect transistor (EGOFET) to that of an OECT by incorporating an ion exchange gel between the active layer and the aqueous electrolyte. This device works by taking up biologically relevant ions from solution and injecting more hydrophobic ions into the active layer. Using poly[2,5-bis(3-tetradecylthiophen-2-yl) thieno[3,2-b]thiophene] as the active layer and a blend of an ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, and poly(vinylidene fluoride-co-hexafluoropropylene) as the ion exchange gel, four orders of magnitude improvement in device transconductance and a 100-fold increase in kinetics are demonstrated. The ability of the ion-exchange-gel OECT to record biological signals by measuring the action potentials of a Venus flytrap is demonstrated. These results show the possibility of using interface engineering to open up a wider palette of organic semiconductors as OECTs that can be gated by aqueous solutions.

Bischak, Connor G.↗

Manipulation and statistical analysis of the fluid flow of polymer semiconductor solutions during meniscus-guided coating

Recent work in structure–processing relationships of polymer semiconductors have demonstrated the versatility and control of thin-film microstructure offered by meniscusguided coating (MGC) techniques. Here, we analyze the qualitative and quantitative aspects of solution shearing, a model MGC method, using coating blades augmented with arrays of pillars. The pillars induce local regions of high strain rates—both shear and extensional—not otherwise possible with unmodified blades, and we use fluid mechanical simulations to model and study a variety of pillar spacings and densities. We then perform a statistical analysis of 130 simulation variables to find correlations with three dependent variables of interest: thin-film degree of crystallinity and transistor field-effect mobilities for charge-transport parallel (Μ para ) and perpendicular (Μ perp ) to the coating direction. Our study suggests that simple fluid mechanical models can reproduce substantive correlations between the induced fluid flow and important performance metrics, providing a methodology for optimizing blade design.

36 MATERIALS SCIENCE↗

Shear History Extensional Rheology Experiment: A Proposed ISS Experiment

The Shear History Extensional Rheology Experiment (SHERE) is a proposed International Space Station (ISS) glovebox experiment designed to study the effect of preshear on the transient evolution of the microstructure and viscoelastic tensile stresses for monodisperse dilute polymer solutions. Collectively referred to as Boger fluids, these polymer solutions have become a popular choice for rheological studies of non-Newtonian fluids and are the non-Newtonian fluid used in this experiment. The SHERE hardware consists of the Rheometer, Camera Arm, Interface Box, Cabling, Keyboard, Tool Box, Fluid Modules, and Stowage Tray. Each component will be described in detail in this paper. In the area of space exploration, the development of in-situ fabrication and repair technology represents a critical element in evolution of autonomous exploration capability. SHERE has the capability to provide data for engineering design tools needed for polymer parts manufacturing systems to ensure their rheological properties have not been impacted in the variable gravity environment and this will be briefly addressed.

Hall, Nancy R.↗

Polyimide adhesives

A process of preparing aromatic polyamide-acids for use as adhesives is described. An equimolar quantity of an aromatic dianhydride is added to a stirred solution of an aromatic diamine in a water or alcohol-miscible ether solvent to obtain a viscous polymer solution. The polymeric-acid intermediate polymer does not become insoluble but directly forms a smooth viscous polymer solution. These polyamic-acid polymers are converted, by heating in the range of 200-300 C and with pressure, to form polyimides with excellent adhesive properties.

Progar, D. J.↗

Modeling Solution Drying by Moving a Liquid-Vapor Interface: Method and Applications

A method of simulating the drying process of a soft matter solution with an implicit solvent model by moving the liquid-vapor interface is applied to various solution films and droplets. For a solution of a polymer and nanoparticles, we observe “polymer-on-top” stratification, similar to that found previously with an explicit solvent model. Furthermore, “polymer-on-top” is found even when the nanoparticle size is smaller than the radius of gyration of the polymer chains. For a suspension droplet of a bidisperse mixture of nanoparticles, we show that core-shell clusters of nanoparticles can be obtained via the “small-on-outside” stratification mechanism at fast evaporation rates. “Large-on-outside” stratification and uniform particle distribution are also observed when the evaporation rate is reduced. Polymeric particles with various morphologies, including Janus spheres, core-shell particles, and patchy particles, are produced from drying droplets of polymer solutions by combining fast evaporation with a controlled interaction between the polymers and the liquid-vapor interface. Our results validate the applicability of the moving interface method to a wide range of drying systems. The limitations of the method are pointed out and cautions are provided to potential practitioners on cases where the method might fail.

36 MATERIALS SCIENCE↗

Chemical Amplification of Subthreshold Base Triggers To Drive Sol–Gel Transitions in Polymers

Chemical amplification has been widely applied in applications ranging from stimuli sensing to advanced photoresists, but it is rarely utilized to drive productive mechanical property changes. Here, we demonstrate the use of a base amplifier to drive the gelation of a functional polymer solution, in response to a subthreshold base trigger through a mechanism whereby the trigger drives a dramatic increase in the base concentration driven by base amplification, resulting in complexation of Fe(III) and polymer-bound catechol groups and subsequent gelation of the polymer solution. Furthermore, the concomitant crystallization of dibenzofulvene, which is a byproduct of base amplification, led to significant stiffening of the resultant gel and an unexpected temperature-sensitive change of gel stiffness.

Aromatic compounds↗

Hanging droplets from liquid surfaces

Natural and man-made robotic systems use the interfacial tension between two fluids to support dense objects on liquid surfaces. Here, we show that coacervate-encased droplets of an aqueous polymer solution can be hung from the surface of a less dense aqueous polymer solution using surface tension. The forces acting on and the shapes of the hanging droplets can be controlled. Sacs with homogeneous and heterogeneous surfaces are hung from the surface and, by capillary forces, form well-ordered arrays. Locomotion and rotation can be achieved by embedding magnetic microparticles within the assemblies. Direct contact of the droplet with air enables in situ manipulation and compartmentalized cascading chemical reactions with selective transport. Applications including functional microreactors, motors, and biomimetic robots are evident.

36 MATERIALS SCIENCE↗

Surface temperatures and glassy state investigations in tribology, part 4

Measurements were made of the limiting shear stress for two naphthenic oils of differing molecular weight and three blends of the lower molecular weight oil and polyalkylmethacrylate polymers of differing molecular weight. The two base oils reached the same limiting shear stress for the same temperature and pressure. This was also true for all the polymer solutions although the polymer reduced the limiting shear stress by about 15 percent. It is shown that limiting stress is more a function of material type than viscosity or molecular weight. A new falling body viscometer was constructed to operate to 230 C and 0.6 GPa. Another viscometer was constructed to extend the pressure range to 1.1 GPa. A concentrated contact simulator was developed which allows recording of the traction force while the slide-roll ratio is continuously varied and the rolling speed is maintained essentially constant by a single drive motor. The configuration is that of a crowned roller against a disk. Measurement of lubricant minimum film thickness of elliptical EHD contacts of various aspect ratios were made by optical interferometry. The data collected were used to evaluate the Hamrock and Dowson minimum film thickness model over a range of contract ellipticity ratio where the major axis of the contact ellipse was aligned both parallel and perpendicular to the direction of motion. A statistical analysis of the measured film thickness data showed that on the average the experimental data were 30 percent greater than the film thickness predicted by the model. Preliminary development of the application of a scanning infrared radiation system to a tribo-system was completed.

Bair, S. S.↗

Evidence for Photoinduced Polaron Generation in a High Persistence Length Low Bandgap Conjugated Polymer in Solution

Using ultrafast time-resolved infrared (TRIR) spectroscopy, we studied the solution-phase excited-state structural evolution of an indacenodithiophene-co-benzothiadiazole polymer (C8-IDTBT). Following band gap excitation, the TRIR spectra reveal vibrational features that develop within 10 ps and decay over 4 ns. Using pulse radiolysis measurements, charge-modulation spectroscopy, and quantum-chemical calculations, the IR features are assigned to polaron pairs. Interestingly, these features appear on an evolving broad mid-IR electronic absorption background, with kinetics correlating with the formation and decay of the cationradical vibrational bands. A three-state kinetic model successfully reproduces the spectral evolution, revealing that the polaron and exciton populations exist in dynamic equilibrium on picosecond time scales, with time constants for exciton dissociation in the range of 3− 5 ps and polaron-to-exciton reformation between 20 and 100 ps, while both species decay to the ground state on much slower nanosecond time scales (∼1 ns), yielding a remarkably high polaron-generation efficiency, higher than 50%. These findings provide fundamental insights into intramolecular charge photogeneration mechanisms in conjugated polymers, demonstrating efficient bound-polaron formation in isolated polymer chains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗