Pool Boiling Heat Transfer Characteristics of HFO-1234yf With and Without Microporous-Enhanced Surfaces
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract Boiling is an effective energy‐transfer process with substantial utility in energy applications. Boiling performance is described mainly by the heat‐transfer coefficient (HTC) and critical heat flux (CHF). Recent efforts for the simultaneous enhancement of HTC and CHF have been limited by an intrinsic trade‐off between them—HTC enhancement requires high nucleation‐site density, which can increase bubble coalescence resulting in limited CHF enhancement. In this work, this trade‐off is overcome by designing three‐tier hierarchical structures. The bubble coalescence is minimized to enhance the CHF by defining nucleation sites with microcavities interspersed within hemi‐wicking structures. Meanwhile, the reduced nucleation‐site density is compensated for by incorporating nanostructures that promote evaporation for HTC enhancement. The hierarchical structures demonstrate the simultaneous enhancement of HTC and CHF up to 389% and 138%, respectively, compared to a smooth surface. This extreme boiling performance can lead to significant energy savings in a variety of boiling applications.
Not Available
Not Available
Abstract not provided
Abstract not provided
Explore the source record for details and available documents.
Not provided.
Boiling water reactor (BWR) spent fuel pool (SFP) criticality safety analyses typically use the in-core k{sub inf} criterion methodology to demonstrate margin to safety. This method models all the fuel in the SFP with a limiting lattice design at a peak reactivity just above a specific in-core k{sub inf} limit. To bound all the fuel in the pool and future fuel with reasonable margin, these limits are often set conservatively high compared to the peak reactivities of actual BWR bundle designs. When current regulatory expectations are met for the quantification of bias and uncertainty adders to the criticality analyses, some results are quantified that are close to the 0.95 in-rack reactivity limit required by 10CFR50.68. The small margins being calculated in the criticality safety analyses have resulted in concerns that SFPs have less margin to safety than was present in the past; however, inherent in the peak reactivity in-core k{sub inf} criterion methodology used to assess these margins is a very conservative model of the fuel. While it is known that all the fuel in a BWR SFP is typically burned well past its peak reactivity exposure, it has been unknown how much reactivity margin could be quantified if bundles were modeled more realistically by accounting for their actual discharge exposure profiles, operational void fractions, control histories, and depletion fuel temperatures. In this study, fuel bundles were depleted to their explicit nodal discharge exposure while accounting for actual operational conditions defined by GEH/GNF's core simulator code, PANACEA. The use of these depleted isotopics in the criticality safety analysis is commonly referred to as taking 'burn-up credit' in the analysis. This paper provides a quantification of the reactivity margin available from burn-up credit in two currently operating BWR spent fuel pools. The evaluation demonstrates that many of the bundles in these storage configurations are significantly below the in-rack reactivity limit, even with the necessary bias and uncertainty adders included. The utilization of BWR burnup credit appears to be an attractive solution to consider when evaluating options for reduced neutron absorber credit or for quantifying additional margin to the regulatory in-rack k{sub eff} limit. (authors)
Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.
Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.
The ability to predict various aspects of boiling is important for both safety and design of water-cooled reactors. Component-scale modelling is necessarily done by semi-mechanistic, semi-empirical approaches, generally based on heat flux partitioning. This needs to be informed by multiple detailed experimental observations of boiling behavior. Such measurements are difficult to make, and much effort is being applied to microscopic computational modelling of the detailed boiling process. Aims of such activities include the mechanistic prediction of growth and detachment of one bubble during nucleate boiling, and the quantification of the associated heat transfer partitioning (evaporation, micro-convection, quenching). We here study a subset of the full problem, and focus on the thermal response of the boiling substrate to the early growth of a single vapour bubble during pool boiling of water at atmospheric pressure. In such conditions, a thin liquid film ('microlayer') is left behind beneath the bubble as this expands. The microlayer evaporates due to the temperature difference between the solid-liquid and vapour-liquid interface. Its thickness being small, of order of microns, the local evaporation rate per unit area of bubble base can be high, up to one kilogram per second. Microlayer evaporation can therefore be important in early stages of bubble growth. In this contribution, thermal response of the boiling substrate to microlayer evaporation is studied with a two-dimensional, axisymmetric transient conduction model, coupled with an algebraic sub-model of the liquid film. The flow of heat through the microlayer is modelled as conduction in the liquid and with a pseudo-convective 'evaporative' heat transfer coefficient at the liquid-vapor interface, accounting for the interface superheat driving the evaporation process. Thermal coupling (conjugate heat transfer) between microlayer and solid substrate is obtained with a time dependent non-homogeneous Neumann boundary condition, derived from the algebraic microlayer sub-model and applied at the top surface of the solid computational domain. The thermal resistance associated to the evaporative heat transfer mechanism is shown to depend on a highly uncertain parameter, termed an 'evaporation coefficient'. After some exploratory calculations of the likely importance of the evaporative resistance in the present context, the model is employed to interpret some recent microlayer measurements. Satisfactory agreement between computed and measured evolution of the microlayer profile is obtained if small values (between 0.01 and 0.10) of the evaporation coefficient are used. The order of magnitude of the predicted evaporation rate from the microlayer is consistent with experimental observations. (authors)
In this investigation, a large number of experiments have been performed to determine saturated nucleate pool boiling heat transfer coefficients of MEA/water and DEA/water binary mixtures and that of water/MEA/DEA ternary mixtures. These heat transfer coefficients have been measured at atmospheric pressure and over a wide range of heat fluxes and solution concentrations. The heat flux has been varied in 14 different levels from 7 to about 230 kW/m{sup 2} and amines concentration has been changed in 10 different levels from zero to 84 wt%. Results show that strong reduction of heat transfer coefficient occurs as a result of mass transfer interference in this phenomenon. Furthermore, in this study, all the correlations proposed during the last years for the prediction of nucleate boiling heat transfer coefficient of mixtures have been categorized in three groups. Some experimental results have been compared with the most accurate representatives of these three groups and the corresponding RMS errors have been calculated. Also, impacts of important existing parameters in these correlations like ideal heat transfer coefficient (h{sub id.}) on the prediction have been discussed. (author)
Recently, development of protective coatings on zirconium-alloy (Zr-alloy) fuel cladding in light water reactors has been extensively investigated to enhance safety margins in accident scenarios. One accident scenario is degradation of the reactor core under a coolant-limited condition, where a large amount of Zr-alloy claddings would react with high temperature steam, leading to oxidation, hydrogen production, and loss of intrinsic mechanical properties of the fuel cladding. Although, total replacement of Zr-alloy with SiC-SiCf composites or FeCrAl is being considered for the long-term, application of oxidation resistant coatings on zirconium-alloy is being investigated as a near-term solution to mitigate oxidation of Zr-alloy and increase the accident coping time. Coatings, such as chromium, Ti{sub 2}AlC, SiC, and Cr{sub 3}C{sub 2}- NiCr, deposited by various deposition techniques have been investigated. In addition, recent studies on modified heating surface for heat transfer enhancement provides basis on the optimal design of coated Zr-alloy claddings so that the new cladding can be achieve accident tolerance and heat transfer efficiency for both accident and normal operation conditions. Therefore, boiling heat transfer from the coated surface to water environment must be evaluated in parallel. In heat transfer performance, boiling heat transfer is characterized by nucleate boiling, critical heat flux (CHF), transition boiling, minimum film boiling temperature (T{sub min}), and film boiling. Zirconium-silicide (ZrSi{sub 2}) is a potentially attractive protective coating material for cladding applications. Although this material has not been studied extensively, it appears to be a promising candidate because of the high melting points, and the low neutron penalty, and the generally good oxidation resistance to transition metal silicides. It has been reported that oxidation of ZrSi{sub 2} powder in a flowing air environment at elevated temperatures produced ZrO{sub 2}, SiO{sub 2}, and ZrSiO{sub 4}, pointing to the possibility of achieving highly protective surface layers of SiO{sub 2} and ZrSiO{sub 4} that would protect the material from further oxidation. In this study, magnetron sputter deposition of ZrSi{sub 2} on zirconium-alloy flats and cylindrical rods was performed. The coated samples were oxidized in high temperature air (700 deg. C, 1000 deg. C and 1200 deg. C) to evaluate their oxidation resistance. The coated cylindrical rods were quenched in saturated water to observe transition boiling, T{sub min}, film boiling regime, while the coated flats were tested in pool boiling facility to investigate nucleation boiling and CHF.
The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) Advanced Fuels Campaign (AFC) is working closely with the nuclear industry to develop fuel and cladding candidates with potentially enhanced accident tolerance, also known as accident tolerant fuel (ATF). Thermal-fluids characteristics are a vital element of a holistic engineering evaluation of ATF concepts. One vital characteristic related to boiling heat transfer is the critical heat flux (CHF). CHF plays a vital role in determining safety margins during normal operation and also in the progression of potential transient or accident scenarios. This deliverable is a scoping survey of thermal-fluids evaluation and confirmatory experimental validation requirements of accident tolerant cladding concepts with a focus on boiling heat transfer characteristics. The key takeaway messages of this report are: 1. CHF prediction accuracy is important and the correlations may have significant uncertainty. 2. Surface conditions are important factors for CHF, primarily the wettability that is characterized by contact angle. Smaller contact angle indicates greater wettability, which increases the CHF. Surface roughness also impacts wettability. Results in the literature for pool boiling experiments indicate changes in CHF by up to 60% for several ATF cladding candidates. 3. The measured wettability of FeCrAl (i.e., contact angle and roughness) indicates that CHF should be investigated further through pool boiling and flow boiling experiments. 4. Initial measurements of static advancing contact angle and surface roughness indicate that FeCrAl is expected to have a higher CHF than Zircaloy. The measured contact angle of different FeCrAl alloy samples depends on oxide layer thickness and composition. The static advancing contact angle tends to decrease as the oxide layer thickness increases.
The time-temperature history of waste slurry feed during melting strongly affects various kinetic processes, such as reaction or dissolution rates, and, consequently, the melting rate. To analyze the time-temperature history of the feed in a cold-cap during nuclear waste vitrification, this work focuses on understanding how the main coldcap body forms, how the aqueous feed slurry interacts with the cold-cap, and estimating the cold-cap heat conductivity. To simulate the conditions during cold-cap formation, samples were prepared by rapid water evaporation from slurry feed. After water evaporated from the sample, a fresh slurry with tracer was poured onto the dry sample. X-ray fluorescence was then used to investigate the degree of penetration and/or mixing between the incoming slurry and the original sample. We show that the slurry does not interact or mix with the previously dry cold-cap crust, but that water-soluble components concentrate at the bottom of the boiling pools, where most of the water evaporates. Further, using the rate of water evaporation, the heat conductivity of the cold-cap was calculated from the measured temperature profile. The resulting conductivity is significantly higher than the values obtained in previous studies. We discuss the implications of the results for the cold-cap formation in the melter and for the development of the cold-cap mathematical model.