Search NASA⌕ Search

SEARCH · Search NASA

Results for “Porous Screen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3

Design, fabrication and testing of porous tungsten vaporizers for mercury ion thrusters

The dispersions in the characteristics, performance and reliability of vaporizers for early model 30-cm thrusters were investigated. The purpose of the paper is to explore the findings and to discuss the approaches that were taken to reduce the observed dispersion and present the results of a program which validated those approaches. The information that is presented includes porous tungsten materials specifications, a discussion of assembly procedures, and a description of a test program which screens both material and fabrication processes. There are five appendices providing additional detail in the areas of vaporizer contamination, nitrogen flow testing, bubble testing, porosimeter testing, and mercury purity. Four neutralizers, seven cathodes and five main vaporizers were successfully fabricated, tested, and operated on thrusters. Performance data from those devices is presented and indicates extremely repeatable results from using the design and fabrication procedures.

Zavesky, R.↗

An Overview of Long Duration Sodium Heat Pipe Tests

High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.

Rosenfeld, John H.↗

A Contaminant Ice Visualization Experiment in a Glass Pulse Tube

Results are presented from pulse tube experiments designed to investigate the effect of 400 parts per million water vapor contamination of the helium working gas. The experiments were conducted in a glass pulse tube to enable visualization of ice formation on internal surfaces. Photographs of this ice formation were taken along with simultaneous coldtip temperature and compressor power measurements. Four types of regenerator elements were tested in various combinations: 200- and 400-mesh stainless steel screens, 1.6 mm diameter glass beads, and 1.6 mm thick perforated plastic plates. Internal spacers were also used to provide clear fields of view into the regenerator stack. Substantial water-ice formation was observed at the cold end of the regenerator and on the inside wall of pulse tube; it appeared to be highly porous, like snow, and was seen to accumulate only in a very localized region at the coldest end, despite changing the cold tip temperature across a range of 150 to 235 K. Ice formation degraded pulse tube thermal performance only in cases where screen regenerators were used at the regenerator cold end. It was concluded that flow blockage was the mechanism by which contaminants affected performance; coarse regenerator elements were largely immune over the tested time scale of a few days. Substantially reduced ice formation and minimal performance loss were also observed in repeated tests where the contaminated gas was reused after warming up and melting of the accumulated internal ice. Significant adsorption of the liquid water onto the regenerator was inferred, a process that depleted the gas phase concentration of water.

Hall, J. L.↗

Battery Separator Characterization and Evaluation Procedures for NASA's Advanced Lithium-Ion Batteries

To address the future performance and safety requirements for the electrical energy storage technologies that will enhance and enable future NASA manned aerospace missions, advanced rechargeable, lithium-ion battery technology development is being pursued within the scope of the NASA Exploration Technology Development Program s (ETDP's) Energy Storage Project. A critical cell-level component of a lithium-ion battery which significantly impacts both overall electrochemical performance and safety is the porous separator that is sandwiched between the two active cell electrodes. To support the selection of the optimal cell separator material(s) for the advanced battery technology and chemistries under development, laboratory characterization and screening procedures were established to assess and compare separator material-level attributes and associated separator performance characteristics.

Baldwin, Richard S.↗

Method for Impeding Degradation of Porous Silicon Structures

This invention relates to surface modification of porosified silicon (pSi) structures with poly(alkylene) glycols for the purpose of controlled degradation of the silicon matrix and tailored release of encapsulated substances for biomedical applications. The pSi structures are currently used in diverse biomedical applications including bio-molecular screening, optical bio-sensoring, and drug delivery by means of injectable/orally administered carriers and implantable devices. The size of the pores and the surface chemistry of the pSi structure can be controlled during the microfabrication process and thereafter. A fine regulation of the degradation kinetics of mesoporous silicon structures is of fundamental importance. Polyethylene glycols (PEGs) represent the major category of surface modifying agents used in classical drug delivery systems and in pharmaceutical dosage forms. PEGylation enables avoidance of RES uptake, thus prolonging circulation time of intravenously injectable nanovectors. PEG molecules demonstrate little toxicity and immunogenicity, and are cleared from the body through the urine (molecular weight, MW less than 30 kDa) or in the feces (MW greater than 30kDa). The invention focuses on the possibility of finely tuning the degradation kinetics of the pSi nanovectors and other structures through surface conjugation of PEGs with various backbone lengths/MWs. To prove the concept, pSi nanovectors were covalently conjugated to seven PEGs with MW from 245 to 5,000 Da and their degradation kinetics in physiologically relevant media (phosphate buffer saline, PBS pH7.4, and fetal bovine serum) was assessed by the elemental analysis of the Si using inductive coupled plasma atomic emission spectroscopy (ICP-AES). The conjugation of the PEG with lowest MW to the nanovectors surface did not induce any change in the degradation kinetics in serum, but inhibited degradation and consequently the release of orthosilicic acid into buffer. When PEGs with the longer chains were evaluated, Si mass loss from the nanovectors was slowed down, and the PEGylated structures were almost fully degraded within 18 24 hours in serum and within 48 hours in PBS. The most dramatic effect was observed for high MW PEGs 3,400 and 5,000 Da, which prominently inhibited the degradation of the systems, with complete degradation achieved only after four days. For these PEGs, during the early stages of the degradation, there was a lag period of little or no Si mass loss from the nanovector. The obtained profiles were in agreement with the erosion of the nanovector surface as observed by scanning electron microscopy.

Vilentchouk, Biana Godin↗

Improved High-Voltage Gas Isolator for Ion Thruster

A report describes an improved high-voltage isolator for preventing electrical discharge along the flow path of a propellant gas being fed from a supply at a spacecraft chassis electrical potential to an ion thruster at a potential as high as multiple kilovolts. The isolator must survive launch vibration and must remain electrically nonconductive for thousands of hours under conditions that, in the absence of proper design, would cause formation of electrically conductive sputtered metal, carbon, and/or decomposed hydrocarbons on its surfaces. The isolator includes an alumina cylinder containing a spiral channel filled with a porous medium made from alumina microbeads fired together with an alumina slurry. Connections to gas-transport tubes are made at both ends of the alumina cylinder by means of metal caps containing fine-mesh screens to prevent passage of loose alumina particles. The outer surface of the alumina cylinder is convoluted to lengthen the electrical path between the metal caps and to afford shadow shielding to minimize the probability of formation of a continuous deposit that would electrically connect the ends. A flanged cylindrical metal cap that surrounds the alumina cylinder without touching one of the ends provides additional shadow shielding.

Banks, Bruce↗

Compact Infrasonic Windscreen

A compact windscreen has been conceived for a microphone of a type used outdoors to detect atmospheric infrasound from a variety of natural and manmade sources. Wind at the microphone site contaminates received infrasonic signals (defined here as sounds having frequencies <20 Hz), because a microphone cannot distinguish between infrasonic pressures (which propagate at the speed of sound) and convective pressure fluctuations generated by wind turbulence. Hence, success in measurement of outdoor infrasound depends on effective screening of the microphone from the wind. The present compact windscreen is based on a principle: that infrasound at sufficiently large wavelength can penetrate any barrier of practical thickness. Thus, a windscreen having solid, non-porous walls can block convected pressure fluctuations from the wind while transmitting infrasonic acoustic waves. The transmission coefficient depends strongly upon the ratio between the acoustic impedance of the windscreen and that of air. Several materials have been found to have impedance ratios that render them suitable for use in constructing walls that have practical thicknesses and are capable of high transmission of infrasound. These materials (with their impedance ratios in parentheses) are polyurethane foam (222), space shuttle tile material (332), balsa (323), cedar (3,151), and pine (4,713).

Zuckerwar, Allan J.↗

Oscillating-Flow Regenerator Test Rig: Hardware and Theory With Derived Correlations for Screens and Felts

A number of wire mesh and metal felt test samples, with a range of porosities, yield generic correlations for friction factor, Nusselt number, enhanced axial conduction ratio, and overall heat flux ratio. This information is directed primarily toward stirling cycle regenerator modelers, but will be of use to anyone seeking to better model fluid flow through these porous materials. Behind these results lies an oscillating-flow test rig, which measures pumping dissipation and thermal energy transport in sample matrices, and several stages of data-reduction software, which correlate instantaneous values for the above dimensionless groups. Within the software, theoretical model reduces instantaneous quantifies from cycle-averaged measurables using standard parameter estimation techniques.

Gedeon, D.↗

The state of the art of conventional flow visualization techniques for wind tunnel testing

Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.

Settles, G. S.↗

Turbulent boundary layer over porous surfaces with different surface geometries

The turbulent boundary layer over three porous walls with different surface geometries was studied in order to investigate the individual influences of porosity and small roughness, as well as their combined effects, on turbulent boundary layer behavior. The tests were conducted in a 2 m x 2 m tunnel on a large axisymmetric model at speeds corresponding to Re(L) = 5,000,000-6,000,000. The development of the turbulent boundary layer was compared for that of sintered metal, bonded screening, and perforated sheet and then to that for the flow over a solid smooth wall and a solid, sand-roughened wall. The comparisons reveal that the effect of porosity is to shift the logarithmic region of the wall law down by a certain amount from the solid wall results and to increase the skin friction values by about 30-40%. The downward shift of the logarithmic region of the wall law and the increase of the skin friction value by the combined effects of small roughness and porosity are found to be roughly the sum of their individual effects.

Kong, F. Y.↗

Highly Porous Polyimide Gel for Use as Battery Separator with Room Temperature Ionic Liquid Electrolytes

Advanced aerospace vehicular concepts require advances in many existing technologies, including space power and energy storage systems. Batteries represent one of the major areas in need of improvement, both in terms of energy density and safety, with growing concerns over the fire safety of commercial lithium-ion batteries. This has prompted efforts to develop nonflammable battery components, namely the electrolyte and separator. Existing commercial lithium-ion batteries utilize polyolefin microporous membranes as separators with an electrolyte consisting of a lithium salt dissolved in a mixture of cyclic carbonate solvents. This separator/electrolyte combination has ionic conductivities in the range of 10 −2 to 10 −3 S/cm. However, the cyclic carbonate solvents are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative. They offer good ionic conductivities and are inherently nonvolatile and nonflammable, giving them a safety advantage. However, many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Alternative separator materials, such as polyimides, are non-flammable and are capable of accepting RTILs into their structure. Polyimide gels, with a composition of 4,4′-oxydianiline, 3,3′,4,4′-tetracarboxylic dianhydride and cross-linked with Desmodur N3300A, possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85% porosity) for lithium-ion transport and conduction, as well as good mechanical properties. Furthermore, these polyimide gels are compatible with selected imidazolium-based RTILs. Nonflammable separator/electrolyte systems with room-temperature conductivities in the range of 10 −3 S/cm have been evaluated. It has been demonstrated that 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was the most promising among six RTILs screened, in terms of both ionic conductivity and constant current cycling.

Polyimide↗

Pressure drop of He II flow through a porous media

The paper reports on measurements of He II pressure drop across two porous SiO2 ceramic filter materials. These materials vary only in porosity, having values of 0.94 and 0.96. The average fiber diameter in both cases is approximately 5 microns. The experiment consists of a glass tube containing a piece of this sponge in one end. The tube is rapidly displaced downward in a bath of helium and the liquid levels are allowed to equilibrate over time producing variable velocities up to 10 cm/sec. The results are compared with those previously obtained using fine mesh screens. Good qualitative agreement is observed for turbulent flow; however, the behavior in the laminar flow regime is not fully understood.

Maddocks, J. R.↗

Thermocapillary flow with evaporation and condensation and its effect on liquid retention in low-G fluid acquisition devices

The steady motion, thermal and free surface behavior of a volatile, wetting liquid in microgravity are studied using scaling and numerical techniques. The objective is to determine whether the thermocapillary and two-phase convection arising from thermodynamic nonequilibrium along the porous surfaces of spacecraft liquid acquisition devices could cause the retention failures observed with liquid hydrogen and heated vapor pressurant. Why these devices seem immune to retention loss when pressurized with heated helium or heated directly through the porous structure was also examined. Results show that highly wetting fluids exhibit large negative and positive dynamic pressure gradients towards the meniscus interline when superheated and subcooled, respectively. With superheating, the pressure variation and recoil force arising from liquid/vapor phase change exert the same influence on surface morphology and promote retention. With subcooling, however, the pressure distribution produces a suction that degrades mechanical equilibrium of the surface. This result indicates that thermocapillary-induced deformation arising from subcooling and condensation is the likely cause for retention loss. In addition, increasing the level of nonequilibrium by reducing accommodation coefficient suppresses deformation and explains why this failure mode does not occur in instances of direct screen heating or pressurization with a heated inert gas.

Schmidt, George R.↗

Influence of Two-Phase Thermocapillary Flow on Cryogenic Liquid Retention in Microscopic Pores

Previous experiments indicate that the bubble point pressure of spacecraft liquid hydrogen acquisition devices is reduced substantially when the ullage is pressurized with heated hydrogen vapor. The objective is to determine whether the two-phase thermocapillary convection arising from thermodynamic non-equilibrium along the porous surfaces of such devices could lead to this observed degradation in retention performance. We also examine why retention capability appears to be unaffected by pressurization with heated helium or direct heating through the porous structure. Computational assessments based on coupled solution of the flowfield and liquid free surface indicate that for highly wetting fluids in small pores, dynamic pressure and vapor recoil dictate surface morphology and drive meniscus deformation. With superheating, the two terms exert the same influence on curvature and promote mechanical equilibrium, but with subcooling, the pressure distribution produces a suction about the pore center-line that degrades retention. This result points to thermocapillary-induced deformation arising from condensation as the cause for retention loss. It also indicates that increasing the level of non-equilibrium by reducing accommodation coefficient restricts deformation and explains why retention failure does not occur with direct screen heating or helium pressurization.

Schmidt, G. R.↗

3D Material Response of the MSL Heatshield Using NuSil-Coated PICA

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performance for protecting probes during planetary entry. Data from the Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. A space-grade silicone-based coating commercially known as NuSil CV-1144-0 [3] was applied to the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of dust from PICA. Modeling the thermal response of PICA-NuSil (PICA-N) system is still an open challenge. Ground testing of PICA-N models exhibited surface temperature jumps of the order of 150 K due to oxide scale formation and sub-sequent NuSil burn-off. It is therefore critical to include a validated model for the material response of the coating in engineering codes. A test campaign has been conducted at the NASA’s Langley HyMETS [4] facility to screen the response of PICA-N and gather detailed data on its behavior [5]. A first model of PICA-N thermal response has been developed using the Hy-METS experiments [6]. The objective of this work is to analyze the material response of the latest PICA-N model compared to the engineering model used to simulate the entry of MSL. The environment and material response around the MSL aeroshell during Mars atmospheric entry is simulated using a collection of tools. The Direct Simulation Monte Carlo SPARTA code [7] is used in the rarefied regime, the Data Parallel Line Relaxation (DPLR) code [8] is used in the continuum regime and radiative heating conditions are provided by the Nonequilibrium air radiation (NEQAIR) code [9] to estimate the environmental conditions. The thermal response inside the material is computed using the Porous material Analysis Toolbox based on Open-FOAM (PATO) [10,11,12]. Thermodynamic and chemistry properties are estimated using the Mutation++ library [13]. The approach implemented in PATO as a first cut PICA-N thermal response model is outlined in Figure 1. While the recession is less than the coating thickness, the Surface mass and energy balance Boundary Condition (SBC) uses the NuSil B’ tables. Once the recession removes the coating, the usual PICA B’ tables are used for the SBC. The B’ tables are computed using an equilibrium solver implemented in Mutation++, given the temperature, pressure, blowing rate, composition of the pyrolysis and environment gases, and the condensed species at the surface. Preliminary results of the 3D material response of the MSL heat-shield at the peak heating (80 sec after Entry Interface) are shown in Figure 2. Current NASA’s mission to Mars, Mars 2020, used the spare heatshield of MSL for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the PATO high-fidelity material response capability was benchmarked against flight data from MEDLI. This effort represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes. This bench-marking is awaiting the final release of the MEDLI-2 data.

Aerospace↗

Bio-inspired Surface Structures to Mitigate Interfacial Particle Adhesion and Erosion - A Review

Lunar dust known as regolith is a huge challenge for lunar exploration missions. Formed over millennia by a complex process involving impacts of meteoroids and micrometeoroids on the lunar surface, lunar dust is porous, highly abrasive with sharp jagged edges, chemically reactive, electrostatically charged and sometimes magnetic. The chemical composition and thickness of the dust layer also varies in different regions of the lunar surface. From samples obtained by previous lunar missions, the average particle size is below 100 microns. This dust has the tendency to strongly adhere to any exposed surfaces, and often degrades the material functionality to eventually cause failure. Any material on the lunar surface is also subject to harsh temperature cycles ranging from -178 ̊C to + 123 ̊C and extreme ultraviolet radiation. While on the lunar surface, different classes of materials would be required for different applications. Advanced materials have been and will be used throughout the lunar lander, habitat, and mission equipment. Examples include: polymeric materials for astronaut protective clothing; metals and ceramics for the lunar lander legs and habitats, and excavating equipment; and semiconductors for solar panels and on-board electronics. In all these applications, the surfaces of the materials are expected or understood to be exposed to the extreme lunar environment condition that includes the regolith dust. During the Apollo missions, the dust clung to and abraded the astronaut’s suits, degraded seals, optics, clogged sensors and reduced performance of thermal radiators. The lunar dust adheres to the surface by various mechanisms, which include electrostatic and Coulombic interactions, Van-der-Waals forces, magnetic forces, mechanical interlocking, chemical bonding and donor-acceptor interactions. There are three primary strategies for developing technologies to minimize the lunar dust adhesion: active, passive and a combination of active and passive. In the active approach, an external energy is needed to prevent or remove particles from collecting on the surface. Mechanically powered brushes and electrodynamic dust screens are two examples. In the passive approach, no external power is needed, and the material surface properties are able to mitigate dust adhesion. A well-known example of this strategy is the low work function coatings for non-stick surfaces. In most cases a combination of active and passive methods might be needed to optimally manage the lunar regolith. The passive method is significantly more attractive as it does not require any external power or an additional control subsystem. These approaches optimize the mission payload and reduce risk. Surface modification to minimize the dust adhesion is thus very important to lunar missions. Here, naturally evolved surface structures might provide guidance for solutions. There are several factors that have to be considered for minimizing particle adhesion to a surface. These include the substrate material properties, surface topography, chemistry, and the characteristics of the adhering particles. When engineering a surface, the substrate material chosen would be dependent on the needs of the application. Tailoring the surface microstructure or chemistry opens up more possibilities for its optimal utilization

Lunar Dust↗