Search NASA⌕ Search

SEARCH · Search NASA

Results for “Portable application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of ESM Readiness Level for Exascale HPC

Advancement of Earth System Models (ESMs) is becoming increasingly challenging due to a confluence of factors including increasing model complexity – to more fully represent the earth system, increasing spatial resolution - to achieve higher accuracy by resolving fine-scale dynamical to physical, biological, and chemical processes and their interaction, increasing ensemble size - to more accurately represent predictive uncertainty, and increased computing requirements – to enable more accurate and timely weather predictions and climate projections for societal benefit. The belief by many that computing will take care of itself is no longer valid given the disruptive changes in HPC that are driving up the cost of computing, increasing the difficulty of using emerging HPC effectively, and exposing limits in parallelism, portability and scalability of the ESM applications themselves.

54 ENVIRONMENTAL SCIENCES↗

The Benefits and Weaknesses of Containerizing Software for HPC

Containerization technology has emerged as a transformative tool for software engineers, offering consistent development and deployment environments, simplifying dependency management, and enhancing scalability and portability across diverse systems. However, its application in High-Performance Computing (HPC) presents unique challenges, including the management of virtualization overhead, the need for efficient resource allocation, and the maintenance of optimal performance for compute-intensiv

Ho, Eric Victor [Sandia National Laboratories (SNL↗

HP-MDR: High-performance and Portable Data Refactoring and Progressive Retrieval with Advanced GPUs

Scientific applications produce vast amounts of data, posing grand challenges in the underlying data management and analytic tasks. Progressive compression is a promising way to address this problem, as it allows for on-demand data retrieval with significantly reduced data movement cost. However, most existing progressive methods are designed for CPUs, leaving a gap for them to unleash the power of today’s heterogeneous computing systems with GPUs.In this work, we propose HP-MDR, a high-performance and portable data refactoring and progressive retrieval framework for GPUs. Our contributions are four-fold: (1) We carefully optimize the bitplane encoding and lossless encoding, two key stages in progressive methods, to achieve high performance on GPUs; (2) We propose pipeline optimization and incorporate it with data refactoring and progressive retrieval workflows to further enhance the performance for large data process; (3) We leverage our framework to enable high-performance data retrieval with guaranteed error control for common Quantities of Interest; (4) We evaluate HP-MDR and compare it with state of the arts using five real-world datasets. Experimental results demonstrate that HP-MDR delivers an average 13.68 × and 6.31 × throughput in data refactoring and progressive retrieval tasks, respectively. It also leads to 11.22 × throughput for recomposing required data representations under Quantity-of-Interest error control and 6.04 × performance for the corresponding end-to-end data retrieval, when compared with state-of-the-art solutions.

Li, Yanliang [University of Oregon]↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

VerifyIO: Verifying Adherence to Parallel I/O Consistency Semantics

VerifyIO is a tool designed for verifying I/O consistency semantics in High-Performance Computing (HPC) applications. It addresses the challenges of ensuring correctness and portability across different I/O consistency models, such as POSIX, Commit, Session, and MPI-IO. By analyzing execution traces, detecting conflicts, and verifying synchronization adherence, VerifyIO provides actionable insights for both application developers and I/O library designers.

Wang, Chen [Lawrence Livermore National Laboratory↗

Lightweight, Flexible Electromagnetic Shielding Composite Films Reinforced with Recycled Carbon Fibers and Carbon Nanofillers

Lightweight, flexible polymer composites are widely adopted in modern electronic devices and systems for high-efficiency electromagnetic interference (EMI) shielding. Reinforcing polymer composites with conductive fillers offers a promising alternative to conventional metal-based shielding material thanks to their low density, tunable properties, and flexibility. Herein, lightweight, flexible ultra-high molecular weight polyethylene composite films reinforced with recycled carbon fibers (rCFs) and carbon-based nanofillers, including graphene nanoplatelets (GNPs) and carbon nanotubes, are reported for EMI shielding applications. The incorporation of these nanofillers significantly reduces the required content of rCFs and improves processability while maintaining comparable shielding effectiveness. The addition of these nanofillers with rCFs enhances the EMI shielding effectiveness by up to 15 dB. Incorporating 1 wt% GNPs can replace 5 wt% rCFs and achieve comparable EMI shielding performance, while 5 wt% of either nanofillers can substitute for 10 wt% rCFs. Numerical modeling of electromagnetic wave transmission reveals that increasing nanofiller concentrations enhances both reflection and absorption losses, with absorption consistently dominating across all levels. Furthermore, this study not only provides insight into the synergistic contributions of rCFs and carbon nanofillers to shielding effectiveness but also paves the way for the design of sustainable, lightweight EMI shielding composite films for applications in electric vehicles, medical equipment, and portable electronics.

carbon nanofiller↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Portable fiber optic sensor for rare earth elements and other critical metals using photoluminescence methods

Rare earth elements and other metals are vital to a range of technologies that are used in the energy and defense sectors. However, monopolistic market conditions have caused significant concern over the stability of the critical metal supply chain, and this has spurred extensive efforts in many nations to produce these metals domestically, both from conventional sources such as mining and well as from unconventional sources such as coal and its utilization byproducts. Slow and expensive characterization methods pose a significant barrier for both metals prospecting and process monitoring. A promising solution to this challenge is the development of highly sensitive luminescent sensors for metals, which can offer low costs, portability, and sensitivity. Anionic zinc adeninate metal-organic frameworks (BioMOFs) are known to distinguishing and detect part-per-billion levels of terbium, europium, samarium, and dysprosium in water by sensitizing the narrow, element-specific emission bands from these lanthanides. Here, a BioMOF material is immobilized onto a large diameter, solarization-resistant fiber optic tip integrated with a portable, low-cost spectrometer for rare earth element sensing. Immobilizing the sensing material on fiber instead of dispersing the sensing material in solution offers several advantages: it facilitates solvent removal, which enhances luminescent signal from the sensitized lanthanides, and it also allows the BioMOF to be recycled for multiple uses. The sensing system was deployed on a simulated process stream and exhibited qualitative agreement with inductively-coupled plasma mass spectrometry for terbium and europium detection, highlighting the potential for the sensing system to be deployed for real-world applications. By using different sensing materials, the same portable sensor may be deployed to detect other energy relevant metals such as cobalt, providing a cost-effective and sensitive platform for critical metal characterization.

Crawford, Scott↗

Toward Automated Detection of Portability Bugs in Kokkos Parallel Programs

Performance-portable programming frameworks provide abstractions for parallel execution to allow easily porting an application to multiple backend programming models, such as CUDA, HIP, and OpenMP. However, programs may still have portability bugs that manifest only on specific backends. Traditional testing is ineffective in discovering these bugs, as it would require concrete execution on all supported hardware configurations for a potentially infinite set of inputs. To mitigate this issue, we focused on a specific programming framework, Kokkos, and identified several categories of common portability bugs. We then developed Klokkos, a static analysis approach based on symbolic execution that can run on commodity hardware, before execution on supercomputers. As a proof-of-concept, we ran Klokkos on examples encoding the identified bugs. Our results show that Klokkos is effective, efficient, and precise: it detected all the considered bugs, quickly, and without any false positives. Although preliminary, our results motivate further research and development in this direction.

Kale, Vivek↗

Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2

The exceptionally low-energy 229 Th nuclear isomeric state is expected to provide several new and powerful applications, including the construction of a robust and portable solid-state nuclear clock, perhaps contributing to a redefinition of the second, exploration of nuclear superradiance and tests of fundamental physics. Further, analogous to the capabilities of traditional Mössbauer spectroscopy, the sensitivity of the nucleus to its environment can be used to realize laser Mössbauer spectroscopy and, with it, new types of strain and temperature sensors and a new probe of the solid-state environment, all with excellent sensitivity. However, current models for examining the nuclear transition in a solid require the use of a high-bandgap, vacuum ultraviolet (VUV) transmissive host, severely limiting the applicability of these techniques. Here we report the first, to the authors’ knowledge, demonstration of laser-induced conversion electron Mössbauer spectroscopy (CEMS) of the 229 Th isomer in a thin ThO 2 sample whose bandgap (approximately 6 eV) is considerably smaller than the nuclear isomeric state energy (8.4 eV). Unlike fluorescence spectroscopy of the 229 Th isomeric transition, this technique is compatible with materials whose bandgap is less than the nuclear transition energy, opening a wider class of systems to study and the potential of a conversion-electron-based nuclear clock.

36 MATERIALS SCIENCE↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Rare Earth Elements (REE) and Critical Minerals (CM) in Middle Pennsylvanian-Age Coals and Associated Sediments in the Central Appalachian Basin, Eastern U.S.A.

The Central Appalachian Basin (CAB) of Kentucky, Tennessee, West Virginia and Virginia has a long history of coal mining and oil and gas extraction that has empowered the regional and national economies, the development of infrastructure, and a highly trained energy resources work force. As our societal demands for advanced technologies have rapidly increased in recent years, coal-related materials are viewed as an important new unconventional domestic source of critical minerals (CM) that are required for telecommunications, aerospace and transportation industries, electronics, the transition to low-carbon emissions energy production, and many consumer products. Coal-related materials encompass coal, associated sediments, coal mining waste materials, produced waters, and ash residues from coal-fired power plants. An important objective of the Evolve Central Appalachia Project (Evolve CAPP), sponsored by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) is to assess the quantity and distribution of CM resources in the CAB region. The rare earth elements (REE) are considered highest priority, although other important CM such as niobium, gallium, and zirconium are known to occur in the Middle Pennsylvanian-age coals and sediments. Working with coal industry partners who provided access to drill cores, coal-related sediments and waste materials, over 600 samples have been collected for laboratory analysis, and over 730 materials have been scanned using portable x-ray fluorescence (pXRF) equipment. The application of pXRF provides the means for real-time semiquantitative analysis of CM content at very close spacings (typically 2-3 inch intervals) along drill core and in-situ channel samples that span the roof, coal seam, and floor rock. The comparison of pXRF geochemical data with laboratory results, geologic data, and downhole spectral gamma logs can provide high resolution input to lithologic and depositional models for future CM resource evaluations. The preliminary findings show that pXRF is capable of accurately measuring low concentrations of many of the CM with a high level of confidence (Ba, Cr, Ga, K, Nb, Rb, Sr, Th, Y), whereas for others (La, Ce, Co, Mn, Nd, Ni, Sc, Ti, V) the detection limits are very high or spectral interferences increase the uncertainty. Notably, the mean abundances of Y (34 ppm), La (86 ppm), Ga (40 ppm), and V (146 ppm) in coal underclays in the CAB region are up to 7X enriched compared with the overlying coal. These values also exceed the reported concentrations in published reference materials for upper continental crustal rocks (Rudnick and Gao, 2003), North American Shale Composite (Gromet et al., 1984), and North American coal (Finkelman, 1993). The pXRF data are in part verified by laboratory results that indicate the mean Y abundance (36 ppm) is highly correlated (R2 = 0.807) with total REE (ΣREE). The correlation is even higher (R2 = 0.957) with heavy REE (ΣHREE). Applying these correlations to the pXRF data for the coal underclays, the mean estimated values for ΣREE+Y and ΣHREE+Y are 270 ppm and 58 ppm, respectively. Although these average values are not considered high, the range of Y measured by pXRF in the coal underclays extended as high as 114 ppm, which would suggest ΣREE+Y equal to 847 ppm. The mean abundances of Zr (192 ppm) and Th (21 ppm) in coal underclays are also enriched compared with the overlying coal and these results likely reflect the presence of resistant detrital heavy minerals such as monazite, xenotime, and zircon in the underclay matrix. Several of the profiled coal seams and associated wall rocks contained thin volcanic ash layers up to 4-5 inches in thickness. The extent to which these ash fall layers provided a source for CM under the paleoenvironmental conditions that resulted in coal deposits in the CAB remains to be fully studied. Continuing investigations in the Evolve CAPP study area will include laboratory determinations of mineralogic and clay compositions, and evaluations of CM geochemical mobility in the coal and coal underclays.

Lassetter, Billy↗

Remote Instrumentation and Data Acquisition

This poster outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and future work, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Illinois U., Urbana]↗

Remote Instrumentation and Data Acquisition: An Internship Research Report

This report outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope’s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and lessons learned, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Fermilab]↗

The Persistent Challenge of Data Locality in the Post-Exascale Era

The era of exascale computing, exemplified by systems like Frontier achieving exaflop-level performance, marks a milestone. However, the quest for sheer compute power leads to strong imbalance in system design. Hence, scaling advancements in memory, network bandwidth, and storage are also necessary and pose challenges, with a crucial need to address data locality issues. This article underscores the fundamental importance of data locality as a key abstraction for optimizing application performance. Despite notable software solutions, the growing complexity of parallelism and memory hierarchy demands performance-portable data locality solutions across diverse computing platforms. Additionally, the article revisits data locality aspects, covering hardware considerations, application perspectives, software stack abstractions, and tool support. It concludes with insights into data locality challenges and opportunities, emphasizing the ongoing significance of collaborative research for progress in this critical issue.

Unat, Didem [Koc University, Istanbul (Turkey)] (O↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗