Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position-sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Double focusing ion mass spectrometer of cylindrical symmetry

A mass spectrometer consisting of an electric sector followed by a magnetic sector is described. The geometry is a cylindrically symmetric generalization of the Mattauch-Herzog spectrometer (1934). With its large annular entrance aperture and a position-sensitive detector, the instrument provides a large geometric factor and 100-percent duty factor, making it appropriate for spacecraft experiments.

Coplan, M. A.↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

Hexagonal uniformly redundant arrays for coded-aperture imaging

Uniformly redundant arrays are used in coded-aperture imaging, a technique for forming images without mirrors or lenses. The URAs constructed on hexagonal lattices, are outlined. Details are presented for the construction of a special class of URAs, the skew-Hadamard URAs, which have the following properties: (1) nearly half open and half closed (2) antisymmetric upon rotation by 180 deg except for the central cell and its repetitions. Some of the skew-Hadamard URAs constructed on a hexagonal lattice have additional symmetries. These special URAs that have a hexagonal unit pattern, and are antisymmetric upon rotation by 60 deg, called hexagonal uniformly redundant arrays (HURAs). The HURAs are particularly suited to gamma-ray imaging in high background situations. In a high background situation the best sensitivity is obtained with a half open and half closed mask. The hexagonal symmetry of an HURA is more appropriate for a round position-sensitive detector or a closed-packed array of detectors than a rectangular symmetry.

Finger, M. H.↗

A facility for investigation of multiple hadrons at cosmic-ray energies

An experimental arrangement for studying multiple hadrons produced in high-energy hadron-nucleus interactions is under construction at the university of Turku. The method of investigation is based on the detection of hadrons arriving simultaneously at sea level over an area of a few square meters. The apparatus consists of a hadron spectrometer with position-sensitive detectors in connection with a small air shower array. The position resolution using streamer tube detectors will be about 10 mm. Energy spectra of hadrons or groups of simultaneous hadrons produced at primary energies below 10 to the 16th power eV can be measured in the energy range 1 to 2000 GeV.

Valtonen, E.↗

Electronic readout systems for microchannel plates

The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

Timothy, J. G.↗

Optical Monitoring of Weld Penetration

Robotic welding controlled by reliable, relatively-noise-free optoelectronic unit. Bounding off meniscus of pool of molten metal, laser beam impinges on position-sensitive photodetector. Beam diameter adjusted for width of weld. Optical filters screen out light from arc. Made from small, low-cost components and utilizing optical fibers to conduct signals, system immune to electromagnetic interference common in industrial environments. Aimed for automatic welders, robot welders in particular and also adaptable to other types of welding, including tungsten/inert-gas, laser, and electron-beam techniques.

Maram, J.↗

Laboratory studies of atomic collision processes of importance in planetary atmospheres

A series of differential cross sections for angular scattering and charge transfer was measured. These studies employ position-sensitive detectors (PSD's) to collect collision products scattered over a wide range of angles; and the research program includes investigation of differential cross sections for total angular scattering, charge transfer, stripping, and other collisions. All of these processes can be studied with the same basic apparatus, but minor modifications in the equipment details and in the data acquisition programs and techniques are required for each individual experiment.

Stebbings, R. F.↗

Differential scattering cross sections for collisions of 0.5-, 1.5-, and 5.0-keV helium atoms with He, H2, N2, and O2

This paper reports the first results of an experimental program established to provide cross section data for use in modeling various atmospheric processes. Absolute cross sections, differential in the scattering angle, have been measured for collisions of 0.5-, 1.5-, and 5.0-keV helium atoms with He, H2, N2, and O2 at laboratory scattering angles between 0.1 deg and 5 deg. The results are the sums of cross sections for elastic and inelastic scattering of helium atoms; charged collision products are not detected. Integration of the differential cross section data yields integral cross sections consistent with measurements by other workers. The apparatus employs a position-sensitive detector for both primary and scattered particles and uses a short target cell with a large exit aperture to ensure a simple and well-defined apparatus geometry.

Newman, J. H.↗

An imaging proportional counter for a 0.1 to 10 keV X-ray telescope

A xenon multiwire position-sensitive proportional counter (PSPC) with a high degree of long-term stability has been constructed and tested in detail. It is suitable for a 0.1 to 10 keV X-ray telescope such as AXAF, which it would share with detectors having better spatial and spectral resolution. Compared to other detectors, the larger format, higher quantum efficiency, and lower background of the PSPC makes it generally the most useful instrument for observations of diffuse cosmic X-ray sources and associations of sources more extended than a few tenths of a degree in diameter. Given the good spatial linearity, the systematic uncertainty for source locations is finer than an arcsecond. The spatial resolution varies as 0.3 mm/exp 0.5 (keV) over the range 0.2-4 keV, in accordance with theoretical limits determined by the size and the number of electrons in the primary charge cloud.

Gorenstein, P.↗

The energetic X-ray imaging telescope experiment (EXITE)

A new position-sensitive scintillation detector (NaI(Tl)), coded mask, and precision pointing system (resolution less than 1 arcmin) are being developed for balloon-borne imaging and spectral studies of cosmic X-ray sources in the 20-300 keV band. The scientific objectives of EXITE, as well as the general design of the detector, telescope and balloon gondola systems are presented.

Grindlay, J. E.↗

A fluorescent gated proportional counter for X-ray astronomy

The development of a position-sensitive proportional counter having a large drift volume is reported. It incorporates a fluorescent gating technique which results in a large improvement in background rejection over conventional proportional counters, and in addition offers the benefit of enhanced energy resolution (predicted to be about 3 percent at 40 keV) above the K shell of Xe.

Ramsey, B. D.↗

Soft X-ray photoemission with the SSX-100 spectrometer

Photoemission and SEXAFS experiments were conducted using a double crystal monochromator at the Stanford Synchrotron Radiation Laboratory. Photoelectrons were detected using a Surface Science Laboratories SSX-100 electron analyzer, which employs a magnetic/electrostatic lens, hemispherical geometry, and a two-dimensional position-sensitive detector. In the kinetic energy range of interest (1000-2000 eV), a significant improvement in count rate was observed over a single channel cylindrical mirror analyzer system. Ten second scans of the KLL silicon Auger peak manifold were recorded at a large number of photon energies for subsequent determination of SEXAFS spectra.

Hecht, M. H.↗

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.↗

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.↗

Position-And-Direction Sensor For Light Beams

Optoelectronic sensor measures both position and direction of incidence of laser beam or other narrow beam of light. New sensor part of robotic welding system in which laser beam reflected from pool of molten metal and monitored by lateral-position sensor. To provide unambiguous measurement of both lateral position and direction of incident beam, sensor includes two position-sensitive photodetectors or linear arrays of photodetectors.

Smith, Matthew A.↗

Development of the RAIDS extreme ultraviolet wedge and strip detector

In the next few years the Remote Atmospheric and Ionospheric Detector System (RAIDS) package will be flown on a Tiros spacecraft. The EUV spectrometer experiment contains a position-sensitive detector based on wedge and strip anode technology. A detector design has been implemented in brazed alumina and kovar to provide a rugged bakeable housing and anode. A stack of three 80:1 microchannel plates is operated at 3500-4100 V. to achieve a gain of about 10 to the 7th. The top MCP is to be coated with MgF for increased quantum efficiency in the range of 50-115 nm. A summary of fabrication techniques and detector performance characteristics is presented.

Kayser, D. C.↗

Calibration and performance of the energetic X-ray imaging telescope experiment

The final integration and testing of the Energetic X-ray Imaging Telescope Experiment (EXITE) are described. The detector and telescope as finally assembled are described, and problems as well as solutions are detailed. The preflight calibration of the position-sensitive NaI detector revealed unanticipated effects in the energy spectra. In particular, an effect due to surface roughness (lack of firm optical polishing) on the crystal was found and calibrated. The radial variation of gain and resolution in the detector was also measured, and so-called flat fielding methods have been derived to analyze the data. The integration of the EXITE detector and gondola systems is described. Several novel features were developed for the EXITE gondola, most notably a shock absorber system. The performance of the detector and gondola systems was evaluated on a first balloon flight from Australia (May 1988) and a second flight from Ft. Sumner, New Mexico (October 1988).

Braga, Joao↗

Soft X-ray spectrographs for solar observations

Recent advances in soft X-ray spectrometery are reviewed, with emphasis on techniques for studying the windowless region from roughly 1-100 A. Recent technological developments considered include multilayer mirrors, large-format CCD detectors which are sensitive to X-rays, position-sensitive photon counting detectors, new kinds of X-ray films, and optical systems based on gratings with nonuniform ruling spacings. Improvements in the extent and accuracy of the atomic physics data sets on which the analysis of spectroscopic observatons depend are also discussed.

Bruner, M. E.↗