Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Lateral distribution of pulse height in a parallel-plate avalanche counter

The nuclear γ-ray spectroscopy enters a new era when the first engineering run of GRETINA [1], a new generation of γ-ray tracking arrays, was successfully carried out at LBNL in early April, 2011. A parallel effort has been setup to develop the auxiliary charged-particle detector arrays with a matching position resolution to fully exploit the potential of GRETINA. Improving the position resolution of the existing charged-particle detector array, CHICO [2], is a part of this coordinated effort. The proposal to upgrade CHICO was approved by DOE/SC at the end of FY10. The goal is to redesign the cathode board and amplifier to improve the resolution for both and coordinates to better than one degree to match that of GRETINA. This project is scheduled to complete by the summer of 2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Signal transformation approach to fast nanopositioning

High bandwidth, high resolution positioning is a significant enabling tool for nanotechnology. Unfortunately, in a typical nanopositioner operating in closed loop, higher bandwidth results in increased sensitivity to measurement noise and hence reduced resolution. In this article we present a technique that allows high-precision tracking of repetitive, jitter-free reference signals without being constrained by the reduction in measurement noise induced positioning resolution. The technique works exceptionally well for scanners with high enough open loop bandwidth and in the absence of high frequency external disturbances. Both simulation and experimental results are presented to illustrate this concept using a triangular reference signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T-1072: Beam test for muon strips

Beam test for muon strips is an experiment to measure the efficiency, time resolution and longitudinal position resolution of scintillator strips for a muon system at future colliders. The muon system at future colliders is envisioned as several layers of position-sensitive detectors embedded in the iron flux-return yoke of the solenoidal magnet. The role of the muon system is primarily the identification of muons and track matching to the central tracker, besides serving as the tail catcher for the hadronic showers that penetrate beyond the hadron calorimetry. Previous tests performed at Fermilab with cosmic muons have shown that scintillators with wavelength-shifting (WLS) fibers and a SiPM readout offer promising performance (NIM A 823, 2016, pp.120-125). The purpose of the present beam tests is to determine the performance parameters with better accuracy. The measurement setup is schematically presented in Fig. 1. The length of the tested strips will vary between 1 m and 2 m. The scintillator strip to be tested will be placed horizontally perpendicular to the beam on a platform in the area behind the beam dump of MT6.2. Two fast scintillators S1 and S2 with vacuum PMT readout will be placed in front and after the tested strip in the beam. The distance between S1 and S2 is 1 m. One fast scintillator strip S3 will be placed in beam immediately in front of the tested strip, perpendicular to the tested strip. A rack with a CAMAC crate and two NIM crates will be used for the data acquisition. The data collection will be performed and monitored from a PC with USB connection to the CAMAC Crate controller.

43 PARTICLE ACCELERATORS↗

HOM Choice Study with Test Electronics for use as Beam Position Diagnostics in 3.9 GHz Accelerating Cavities in FLASH

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 \mu m was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.

43 PARTICLE ACCELERATORS↗

Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout

Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Furthermore, light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Control for X-Ray Mircroscopes

In this article, a systematic framework for designing the control for fine positioning (scanning) stages of X-ray microscopes is presented. This framework facilitates designs that simultaneously achieve specifications on positioning resolution and tracking bandwidth while guaranteeing robustness of the closed loop device to unmodeled uncertainties. We use robust optimal control techniques for modeling, quantifying design objectives and system-specific challenges, and designing the control laws. The control designs were implemented on a three degree of freedom piezoactuated flexure stages dedicated for fine positioning of X-ray optics. Experimental results demonstrate significant improvements in positioning performance of 134%, 150%, and 132% in tracking bandwidths along the lateral (X), vertical (Y), and beam (Z) directions, respectively, when compared to proportional-integral-derivative controller designs. This was achieved while keeping similar or better positioning resolution and robustness measures. Fast scanning for X-ray imaging was demonstrated in both the step scan and flyscan modes, where bandwidth was improved by over 450 times with flyscan compared to the step scan.

42 ENGINEERING↗

Gamma-ray tracking method for pet systems

Gamma-ray tracking methods for use with granular, position sensitive detectors identify the sequence of the interactions taking place in the detector and, hence, the position of the first interaction. The improved position resolution in finding the first interaction in the detection system determines a better definition of the direction of the gamma-ray photon, and hence, a superior source image resolution. A PET system using such a method will have increased efficiency and position resolution.

60 APPLIED LIFE SCIENCES↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leveraging staggered tessellation for enhanced spatial resolution in high-granularity calorimeters

Here we advance the concept of high-granularity calorimeters with staggered tessellations, underscoring the effectiveness of a design incorporating multifold staggering cycles based on hexagonal cells to enhance position resolution. Moreover, we introduce HEXPLIT, a sub-cell re-weighting algorithm tailored to harness staggered designs, resulting in additional performance improvements. By combining our proposed staggered design with HEXPLIT, we achieve an approximately twofold enhancement in position resolution for neutrons across a wide energy range, as compared to unstaggered designs. These findings hold the potential to elevate particle-flow performance across various forthcoming facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking performance of a single-crystal and a polycrystalline diamond pixel-detector

We present a comparative characterization of the performance of a single-crystal and a polycrystalline diamond pixel-detector employing the standard CMS pixel readout chips. Measurements were carried out at the Fermilab Test Beam Facility, FTBF, using protons of momentum 120 GeV/c tracked by a high-resolution pixel telescope. Particular attention was directed to the study of the charge-collection, the charge-sharing among adjacent pixels and the achievable position resolution. The performance of the single-crystal detector was excellent and comparable to the best available silicon pixel-detectors. The measured average detection-efficiency was near unity, ε = 0.99860±0.00006, and the position-resolution for shared hits was about 6 μm. On the other hand, the performance of the polycrystalline detector was hampered by its lower charge collection distance and the readout chip threshold. A new readout chip, capable of operating at much lower threshold (around 1 ke $-$ ), would be required to fully exploit the potential performance of the polycrystalline diamond pixel-detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space Mirror Alignment System

An optical alignment mirror mechanism (AMM) has been developed with angular positioning accuracy of +/-0.2 arcsec. This requires the mirror s linear positioning actuators to have positioning resolutions of +/-112 nm to enable the mirror to meet the angular tip/tilt accuracy requirement. Demonstrated capabilities are 0.1 arc-sec angular mirror positioning accuracy, which translates into linear positioning resolutions at the actuator of 50 nm. The mechanism consists of a structure with sets of cross-directional flexures that enable the mirror s tip and tilt motion, a mirror with its kinematic mount, and two linear actuators. An actuator comprises a brushless DC motor, a linear ball screw, and a piezoelectric brake that holds the mirror s position while the unit is unpowered. An interferometric linear position sensor senses the actuator s position. The AMMs were developed for an Astrometric Beam Combiner (ABC) optical bench, which is part of an interferometer development. Custom electronics were also developed to accommodate the presence of multiple AMMs within the ABC and provide a compact, all-in-one solution to power and control the AMMs.

Jau, Bruno M.↗

A drift multiwire proportional counter for cosmic soft X-ray imaging

Multiwire proportional counters with 1 micrometer polypropylene windows, of dimensions 75 mm x 75 mm and 100 mm x 100 mm, have been built to map soft cosmic X-rays. The counters are constructed with a large drift region which makes it possible to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micrometer diameter, gold-plated tungsten wire spaced 1mm apart, a position resolution of better than 280 micrometers (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV was achieved.

Reid, P. B.↗

The application of a drift multiwire proportional counter to the imaging of low energy X-rays

A 75 mm x 75 mm multiwire proportional counter (MWPC) with a 1 micron polypropylene window has been built to map low energy X-rays. The MWPC is constructed with a large drift region which allows us to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micron diameter Au-plated tungsten wire spaced 1 mm apart, a position resolution of better than 240 microns (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV has been achieved.

Ku, W. H.-M.↗

Resolution Performance of HERA-B Lead-Glass Calorimeters

In preparation of upcoming 12GeV experiments at Thomas Jefferson National Accelerator Facility it is necessary to upgrade existing systems or install new detectors. As part of this effort, an array of lead-glass sampling calorimeters is need for use in the GEP-5 experiment. A sampling calorimeter can be used to determine the energy and spatial position of a high energy particle that enters it while simultaneously stopping the particle. To determine the appropriate construction to meet the needs of upcoming experiments, it was necessary to take an existing model and confirm its energy and position resolution. This model could then be confirmed as an option for the final construction, or used as a starting point to design a better detector. For our test we obtained ten lead-glass calorimeters used in HERA-B and tested them in End Station A at SLAC. I will report on our findings for the HERA-B lead-glass sampling calorimeters. I will cover the results of both the energy and position resolutions as well as the methods used to determine these quantities.

Losada, Anthony↗

Position-Sensitive Fast-Neutron Detector Development in Support of Fuel-Cycle R&D MPACT Campaign

In the present work, fast-neutron imaging detectors with centimeter position resolution are developed whose active volume is liquid scintillator EJ-309, allowing neutron-gamma discrimination via pulse shape. Furthermore, a production version sealed detector is constructed that allows arrangement in a close-packed array for imaging applications. The combination of position resolution, neutron-gamma discrimination, and ready assembly into an imaging array will enable sensitive diagnostic fast-neutron imaging of neutron sources of interest to fuel cycle applications.

Blackston, Matthew A.↗

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions 10 B (n,α0γ) 7 Li (6%) and 10 B(n,α1γ) 7 Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts α, 7 Li and γ (electron recoils). A signal-to-noise improvement on the order of 10 4 over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m 2 . The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $\alpha$, $^7$Li and $\gamma$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗