Hydrogen Carriers for Renewable Microgrid System Applications

Utility-scale energy storage can help improve grid reliability, reduce costs, and promote faster adoption of intermittent sources such as solar and wind. This paper analyzes the technical aspects and economics of standalone microgrids operating on intermittent power combined with hydrogen energy storage. It explores the feasibility of using dibenzyltoluene (DBT) as a liquid organic hydrogen carrier to absorb excess energy during periods of high supply and polymer electrolyte fuel cells to generate electrical energy during periods of low supply. A comparative analysis is conducted on three power demand scenarios (industrial, residential, and office), in conjunction with three alternative energy sources: solar, wind and wind–solar mix. A mixed system of solar and wind energy can maintain an annual average efficiency above 70%, except for residential power demand, which lowered the efficiency to 67%. A balanced combination of wind and solar power was the most cost-effective option. The current levelized cost of electricity (LCOE) for industrial power demand was estimated to 15 ¢/kWh, and it is projected to decrease to 9 ¢/kWh in the future. For residential power demand, the LCOE was 45% higher due to the demand profile. In comparison, battery storage is significantly more expensive than hydrogen storage, even with future cost projections, increasing the LCOE between 60 and 120 ¢/kWh.

PEM electrolysis↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Investigation of startup, performance and cycling of a residential furnace integrated with micro-tubular flame-assisted fuel cells for micro-combined heat and power

Solid Oxide Fuel Cells (SOFCs) offer advantages for micro-Combined Heat and Power (μCHP), but currently suffer from slow startup (>1 h) and limited thermal cycling which reduces the applications, energy savings and economics. In this work, a micro-Tubular SOFC stack is integrated into a residential furnace to create a micro-Tubular Flame-assisted Fuel Cell (mT-FFC) μCHP system. A high power density of 202 mW cm -2 is reported operating in synthesis gas generated from fuel-rich combustion of natural gas/air. Unlike previous reports, instabilities in the polarization are attributed to low temperature of the oxygen reduction reaction at the cathode. The mT-FFC stack achieved peak power density in 6 min after ignition. 200 thermal cycles at an average heating rate of 215 °C.min -1 and average cooling rate of 176 °C.min -1 were conducted and a low degradation rate of 0.0325 V per 100 cycles per fuel cell was achieved. Low NO x emissions (10 ppm) and high combined efficiency is reported.

25 ENERGY STORAGE↗

Power output of turbines mounted on tension-leg platforms subjected to fully developed ocean gravity waves

A concern in the deployment of large wind turbines on ocean floating platforms is the effect of floating-platform motions on their electrical power generation. Further, it is not clear how floating motions influence waking, which might affect the combined power generation of collections of turbines. We examine the average power output of a single and a collection of NREL 5 MW wind turbines mounted on a tension-leg platform (TLP) under the action of fully developed ocean wave motions, coupling floating motions with the large-eddy simulation (LES) of atmospheric and rotor dynamics. The ocean dynamics enter as fully developed waves derived from the Pierson–Moskowitz spectrum. To assess the influence of ocean motions, we performed simulations over the full range of wind speeds in the operational range of the turbine, reporting comparisons of average power output when the platforms are allowed to move to when they are held rigidly in place. In all simulations, we find that the effects of the TLP floating-platform's induced motions have a minor effect on single and multiple turbine power production and wake deficits. Even when using coherent and large amplitude harmonic-floating-induced perturbations, any significant wake modifications from floating motions are confined to the near-wake region, where downstream turbines are unlikely to be located. The relatively small amplitude of TLP motions relative to pre-existing turbulent fluctuations are the primary reason for low wake and power modifications downstream.

Restrepo, Juan [ORNL] (ORCID:0000000326092882)↗

Power Profile Monitoring and Tracking Evolution of System-Wide HPC Workloads

The power & energy demands of HPC machines have grown significantly. Modern exascale HPC systems require tens of megawatts of combined power for computing resources and cooling facilities at full capacity. The current energy trend is not sustainable for future HPC systems, and there is a need to work toward the energy efficiency aspect of HPC performance. Energy awareness of the HPC applications at the job level is essential for running an efficient HPC system. This work aims to develop a pipeline to provide a production-level system-wide overview of the HPC workloads' power profile while handling evolving workloads exhibiting new power trends. We developed an open-set classification model for HPC jobs based on the properties of power profiles to continuously provide a system-wide holistic view of recently completed jobs. The pipeline helps continuously monitor the job-level power usage pattern of HPC and enables us to capture the new trends in applications' power behavior. We employed a comprehensive set of techniques to generate job-level data, custom-designed feature extraction methods to extract critical features from jobs' power profiles, clustering techniques powered by generative modeling, and open-set classification for identifying job profiles into known classes or an unknown set. With extensive evaluations, we demonstrate the effectiveness of each component in our pipeline. We provide an analysis of the resulting clusters that characterize the power profile landscape of the Summit supercomputer from more than 60K jobs executed in a year. The open-set classification classifies the known data sets into known classes with high accuracy and identifies unknown data noints with over 85% accuracy.

Karimi, Ahmad Maroof↗

Measurements of elastoresistance under pressure by combining in-situ tunable quasi-uniaxial stress with hydrostatic pressure

Uniaxial stress, as well as hydrostatic pressure are often used to tune material properties in condensed matter physics. Here, we present a setup which allows for the study of the combined effects of quasi-uniaxial stress and hydrostatic pressure. Following earlier designs for measurements under finite stress at ambient pressure (e.g., Chu et al., Science 337, 710 (2012)), the present setup utilizes a piezoelectric actuator to change stress in situ inside the piston-cylinder pressure cell. We show that the actuator can be operated over the full temperature (from 30 K up to 260 K) and pressure range (up to ≈ 2 GPa), resulting in a clear and measurable quasi-uniaxial strain. To demonstrate functionality, measurements of the elastoresistance (i.e., the change of resistance of a sample as a response to quasi-uniaxial strain) under finite hydrostatic pressure on the iron-based compound BaFe 2 As 2 are presented as a proof-of-principle example, and discussed in the framework of electronic nematicity. Overall, this work introduces the combination of in situ tunable quasi-uniaxial stress and large (up to ≈ 2 GPa) hydrostatic pressure as a powerful combination in the study of novel electronic phases. In addition, it also points towards further technical advancements which can be made in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AMO Fall 2020 Combined Heat and Power (CHP) Virtual Workshop

The U.S. Department of Energy’s (DOE’s) Advanced Manufacturing Office held the Fall 2020 Combined Heat and Power (CHP) Virtual Workshop in September 2020. The workshop brought together more than 90 individuals representing manufacturers, end users, utilities, academia, government, and other stakeholders to discuss the potential role that energy-efficient combined heat and power (CHP) technologies can play in enhancing the energy flexibility and resilience of manufacturing facilities, as well as the advancements needed to bolster technology adoption. This workshop report summarizes the presentations, panel discussions, and breakout group discussions that took place at this event.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a micro-combined heat and power powered by an opposed-piston engine in building applications

Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Review and Qualitative Analysis of Micro-Combined Heat and Power Modeling Approaches

Concurrent production of electrical and thermal energy from a Combined Heat and Power (CHP) device is an attractive tool to address the growing energy needs of the planet. Micro CHP (µCHP) systems can reduce a building’s primary energy consumption, reduce carbon footprint, and enhance resiliency. Modeling of the µCHP helps understand the system from multiple perspectives and helps discover errors earlier, improves impact analysis and simulation of system solutions for ease of integration with the building. Consequently, there is a need for analysis of the impact of µCHP modeling approach on its reliability and flexibility. The primary objective of this paper is to review the state-of-the art models in the µCHP space with a focus towards internal combustion engine as the primary mover (PM) and limit the study to system modeling, calibration, and validation methodologies. Based on the analysis, recommendations for further model considerations and refinements are presented.

42 ENGINEERING↗

Advanced Research on Integrated Energy Systems Cyber Range

As digital technologies expand to meet the needs of a more autonomous, interconnected, and advanced power system, new cybersecurity complexities and vulnerabilities arise. The ARIES Cyber Range enables the energy sector to evaluate these evolutions and validate cybersecurity solutions without impacting live systems. Combining power grid-scale hardware with emulation and simulation approaches, the ARIES Cyber Range can faithfully replicate modern energy systems - from grid physics to communication networks, and everything in between - with real-world fidelity. At NLR, researchers and partners are answering complex power system cybersecurity questions, examining emerging threats to the electric sector, and de risking new security technologies, all at a mission-relevant speed that keeps pace with rapidly evolving systems and hazards.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Combined Heat and Power Technology Fact Sheet Series: District Energy

This fact sheet provides an overview of district energy systems, which are characterized by one or more central plants producing hot water, steam, and/or chilled water, which then flows through a network of insulated pipes to provide hot water, space heating, and/or air conditioning for nearby buildings. District energy systems serve a variety of end-use markets, including downtowns (central business districts), college and university campuses, hospitals and healthcare facilities, airports, military bases, and industrial complexes. By combining loads for multiple buildings, district energy systems create economies of scale that help reduce energy costs and enable the use of high-efficiency technologies such as combined heat and power (CHP).

Combined Heat and Power, CHP, District Energy, Tec↗

Cross-Layered Cyber-Physical Power System State Estimation towards a Secure Grid Operation

In the Smart Grid paradigm, this critical infrastructure operation is increasingly exposed to cyber-threats due to the increased dependency on communication networks. An adversary can launch an attack on a power grid operation through False Data Injection into system measurements and/or through attacks on the communication network, such as flooding the communication channels with unnecessary data or intercepting messages. A cross-layered strategy that combines power grid data, communication grid monitoring and Machine Learning based processing is a promising solution for detecting cyberthreats. In this paper, an implementation of an integrated solution of a cross-layer framework is presented. The advantage of such a framework is the augmentation of valuable data that enhances the detection of anomalies in the operation of power grid. IEEE 118-bus system is built in Simulink to provide a power grid testing environment and communication network data is emulated using SimComponents. The performance of the framework is investigated under various FDI and communication attacks.

cyber security, network security, cyber-physical s↗

Northwest Combined Heat and Power Technical Assistance Partnership: Final Scientific/Technical Report

During the years of 2018 through 2023, The Washington State University Energy Program (WSU EP) operated the Northwest Combined Heat and Power Technical Assistance Partnership under contract to the US Department of Energy’s Advanced Manufacturing Office (AMO), a part of DOE’s larger Office of Energy Efficiency and Renewable Energy. This contract provided direction and funding for providing technical outreach, information and technical/economic analysis services in support of expanding development of Combined Heat and Power (CHP) over a four state region in the Pacific Northwest. The states served included Alaska, Idaho, Oregon and Washington. During the duration of this contract, the WSU EP delivered performed specific assigned tasks and provided services of various generally prescribed types, with the overall goal of increasing adoption of CHP as an efficient heat and power supply in the region. Indications – though not formally evaluated to our knowledge – are that this goal was achieved. Over many years, the WSU team has provided support for CHP developments in these states under similar previous Department of Energy contracts, and many such projects have been built. While the early-phase outreach, education and techno-economic assessments that the NW CHP TAP provides rarely immediately result in project construction, there is no doubt that the WSU EP team has had substantial influence in the construction of a number of important CHP projects in the region. Examples of projects implemented directly under the current team’s guidance and services during this contract cycle include an 875 kilowatt biomass fueled CHP system installed at the University of Idaho, and 5 megawatt natural gas fueled CHP system at the University of Montana ( UM Breaks Ground on New Power Facility, Slashes Emissions 30% (umt.edu) ). Many other CHP systems recently installed are also either directly or at least partially the result of information and technical services provided by the team. Finally, though much more difficult to quantify and less glamorous, the team has helped countless organizations to understand CHP and determine whether and how CHP may be a fit for them, before they consider paying for engineering services. Whether the ultimate outcome has been to include CHP or not, the expert skills provided by the NW CHP TAP team have provided real value to these organizations considering this relatively complex technology. Over the duration of the contract our team provided 71 Initial Technical Assessments and 17 Advanced Technical Assessments; 53 End-User Engagements and 33 Stakeholder Engagements of various types; 42 Technical Profiles (Project Profiles, Program Profiles and Policy Profiles), and produced 14 technical articles for the Department of Energy. Unfortunately, these quantities provide no measure of the value that the team has provided. Only our clients can judge that, and we are confident that they are pleased with the benefits we have offered them.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Plasma production and ion heating systems for the Material Plasma Exposure eXperiment

Plasma production and ion heating in the Material Plasma Exposure eXperiment (MPEX), whose design is nearing completion, is accomplished using continuous wave RF power with average power density up to 1.6 MW/m2 at the plasma interface. Plasma is produced using helicon waves coupled through a single helical antenna at 13.56 MHz with power supplied by three 100 kW fixed-frequency RF generators feeding a power combiner network followed by the matching network and launcher. The helicon source can utilize various gasses including hydrogen, deuterium, and helium, with a magnetic field strength in the source region up to 0.2 T, and maximum device |B| of 2.5 T. Power is coupled to ions via ion cyclotron heating at the fundamental resonance using a pair of phased helical antennas operating in the frequency range 4-9 MHz, that launch waves towards the resonance from the antenna region where ω > ωci. ICH power is supplied by a single 500 kW tunable RF transmitter through a 90° power splitter and matching/decoupling network. In the case of both the helicon and ICH systems the antennas are located external to the vacuum, with power transferred through novel water-cooled coaxial vacuum windows consisting of fused quartz outer cylinders and silicon nitride inner cylinders with forced convection water cooling between them. The antenna enclosures are pressurized with dry air to 3 bar absolute for voltage standoff.Several 3-D COMSOL models have been created to simulate the two systems. A model of the helicon region utilizing a cold plasma dielectric tensor with accurate magnetic field and realistic plasma density profiles has been used to calculate the plasma loading/complex antenna input impedance at the launcher feed for various ne and |B| values, for the purpose of estimating power handling. It also incorporates the geometry of all launcher structures relevant to this determination. A still more detailed model of the launcher together with a lossy dielectric plasma surrogate has been used to determine RF electric field values and power losses in the device components.Similar models have been produced to predict the performance and power handling of the ICH launcher. For this device the impedance matrix of the two-element antenna array is calculated using a warm plasma model, necessary to properly determine the wave propagation and absorption.

Goulding, Richard↗

System and component development for long-duration energy storage using particle thermal energy storage

Energy storage, at various scales, will be required to maintain reliable power supply from variable renewable resources, and improve grid resilience. Long-duration energy storage (10-100 h) can substitute baseload coal power generation and increase levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus it has the potential to meet the needs of long-duration energy storage. Here, a novel TES system was developed by using solid particles as storage media and charging/discharging electricity from renewable power connected via the electric grid. The particle TES uses low-cost silica sand at 30-40$/Ton that is stable at high temperatures of >1,000 degrees C. Thus, the particle TES system has an overall low storage cost and high thermal-power efficiency. Key components of the system were conceptually designed and modeled for their performance. Conversion of electricity to thermal energy using electric heating can achieve a >98% charging efficiency, and the conversion of thermal energy back to electricity uses an air-Brayton combined power cycle with >52% thermal-to-electricity efficiency at >1,170 degrees C to achieve a >50% roundtrip efficiency after subtracting estimated plant parasitic losses. Laboratory-scale prototypes were fabricated and tested to verify their design approaches and operations relevant to product-scale components.

25 ENERGY STORAGE↗

Study on divertor detachment and pedestal characteristics in the DIII-D upper closed divertor

Abstract Experiments performed in DIII-D demonstrate that higher plasma current and heating power combined with impurity seeding facilitate the achievement of divertor detachment with a higher pedestal pressure and higher plasma performance in H-mode plasmas with a baffled closed divertor compared with an open divertor. Dedicated experiments were carried out to study the impact of power, plasma current and impurity seeding on divertor detachment with ion B × ∇ B directed into the divertor favorable for the L–H transition. With a factor of three variation in heating power and with only D 2 puffing, no significant difference in the separatrix density at detachment onset was found. The higher heating power leads to higher impurity concentration and wider scrape-off layer (SOL) width, and reduces the detachment onset density to one similar to that in lower-power plasmas. Higher current requires higher pedestal and line-averaged densities to achieve divertor detachment; however, the increase in separatrix density at increasing plasma current is found to be less pronounced. Initial calculations found that both power scan and plasma current scan datasets are qualitatively consistent with theory after considering the change in impurity concentration and heat flux width. This also motivates the future extensive study of transport and divertor impurity behavior in order to have a quantitative comparison between experiment and theory. Compared with an open divertor, a closed divertor facilitates detachment onset at ∼40% lower line-averaged plasma density. Additional N 2 seeding facilitates the achievement of detachment at a lower separatrix density and thus a higher pedestal temperature, which is beneficial for advanced tokamak scenarios. Higher heating power requires a higher N 2 puffing rate to achieve the same degree of detachment, while a higher N 2 puffing rate leads to lower detachment onset line-averaged density, both of which agree with theory. In contrast to the narrower pedestal in an open divertor approaching detachment, the pedestal density width in a closed divertor increases with density. The density gradient increases with line-averaged density at higher plasma current, but remains nearly unchanged at lower plasma current. In particular, compared with discharges with low power, at high heating power the pedestal density gradient is much weaker, while the SOL density is significantly higher and wider. At the same plasma current, both pedestal pressure gradient and temperature gradient decrease linearly with the line-averaged density but remain similar across different heating powers. Even with different plasma current and heating power, the normalized pressure gradient remains identical. As a result, achievement of divertor detachment with a higher pedestal pressure and higher plasma performance is shown in a closed divertor, which is important for improving core–edge integration as one of the critical issues for future tokamak fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.

combined heat and power (CHP)↗

U.S. DOE Southeast Combined Heat and Power Technical Assistance Partnership

During the five-year period from September 2018 to December 2023, the Industrial Efficiency and Decarbonization office (IEDO) of the U.S. Department of Energy (DOE) funded the Southeast Combined Heat and Power Technical Assistance Partnership (Southeast CHP TAP), managed the NC Clean Energy Technology Center located at NC State University (NCSU). The Southeast CHP TAP was one of ten regional CHP TAPs established to promote and assist in transforming the market for combined heat and power (CHP) and related technologies, including district energy (DE) and waste heat to power (WHP) throughout the United States. CHP, also known as cogeneration, is an efficient and clean approach to generating on-site electric power and useful thermal energy from a single fuel source.