Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Coupling Factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Scanning beam antenna conceptual design for 20/30 GHz satellite systems

The configuration described is one of four antenna system configurations developed using a variety of monolithic microwave integrated circuit module arrangements and optical systems. A parametric analysis is expected to produce a data base for the selection of design points for a variety of applications. Soon to be accomplished is the design concept of the active (lens) array, which will take into consideration such factors as, coupling effects, the space-fed power divider network design, input bias and control layout, investigation of thermal distribution, and analysis of module failure (graceful degradation).

Smetana, J.↗

Operating features of an ion-cyclotron-wave plasma apparatus running in the RF-sustained mode

An experimental study has been made of an ion-cyclotron-wave apparatus operated in the RF-sustained mode. This is a mode in which the Stix RF coil both propagates the waves and maintains the plasma. Problems associated with this method of operation are presented. Some factors that are important to the coupling of RF power are noted. In general, the wave-propagation and wave-damping data agree with theory. Some irregularities in wave fields are observed. Maximum ion temperature is 870 eV at a density of 5 times 10 to the 12th power per cubic centimeter and RF power of 90 kW. Coupling efficiency is 70 percent.

Swett, C. C.↗

Performance of an ion-cyclotron-wave plasma apparatus operated in the radiofrequency sustained mode

An experimental study has been made of an ion-cyclotron-wave apparatus operated in the RF-sustained mode, that is, a mode in which the Stix RF coil both propagates the waves and maintains the plasma. Problems associated with this method of operation are presented. Some factors that are important to the coupling of RF power are noted. In general, the wave propagation and wave damping data agree with theory. Some irregularities in wave fields are observed. Maximum ion temperature is 870 eV at a density of five times 10 to the 12th power cu cm and RF power of 90 kW. Coupling efficiency is 70 percent.

Swett, C. C.↗

Optimization of Higher Order Mode Dampers in the 56MHz SRF Cavity for RHIC

A 56 MHz superconducting RF cavity was designed for a luminosity upgrade of the Relativistic Heavy Ion Collider (RHIC), including requirements for Higher Order Mode (HOM) damping. In this paper, we describe our optimization of the damper's performance, and modifications made to its original design. We also show the effects of the damper geometry on the cavity's HOM impedance. To reduce the likelihood of magnetic breakdown, we lowered the magnetic field enhancement at the ports to a value less than the highest field in the cavity. We simulated all monopole and dipole HOMs up to 1GHz with their frequencies, mode configurations, R/Qs, and shunt impedances, verifying that all modes are well-damped with the optimized design and configuration. The 56 MHz superconducting RF cavity is a quarterwave resonator designed to have a gap voltage of 2.5 MV. Our plans are to place this beam-driven resonator at a common section of RHIC to provide a storage RF potential for both rings. The large bucket of the cavity will reduce spill due to Intra-Beam Scattering (IBS), and thus increase the luminosity for the detectors. It is very important to damp all the cavity's Higher Order Modes (HOMs) to avoid beam instabilities. The design chosen for the HOM damper is a magnetically coupled loop located at the rear end of the cavity. The loop and its port geometry must be optimized to assure sufficient damping, avoid a large enhancement of the local magnetic field. A high-pass filter is included in the circuit to reduce the power extraction from the fundamental mode. The number of HOM dampers used and their configuration also are important factors for the damping and cooling system. A small loop area will couple out less power from the cavity's fundamental mode, thus reducing the voltage and power dissipation in the damper's filter circuit; however, it might not be sufficient for HOM damping. This problem is resolved by increasing the number of the HOM dampers and carefully choosing their location. Details of the high-pass filter will be discussed in another paper.

43 PARTICLE ACCELERATORS↗

Chaotic inflation limits for non-minimal models with a Starobinsky attractor

We investigate inflationary attractor points by analysing non-minimally coupled single field inflation models in two opposite limits; the 'flat' limit in which the first derivative of the conformal factor is small and the 'steep' limit, in which the first derivative of the conformal factor is large. We consider a subset of models that yield Starobinsky inflation in the steep conformal factor, strong coupling, limit and demonstrate that they result in φ{sup 2n}-chaotic inflation in the opposite flat, weak coupling, limit. The suppression of higher order powers of the inflaton field in the potential is shown to be related to the flatness condition on the conformal factor. We stress that the chaotic attractor behaviour in the weak coupling limit is of a different, less universal, character than the Starobinsky attractor. Agreement with the COBE normalisation cannot be obtained in both attractor limits at the same time and in the chaotic attractor limit the scale of inflation depends on the details of the conformal factor, contrary to the strong coupling Starobinsky attractor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vehicular Integration of Wireless Power Transfer Systems and Hardware Interoperability Case Studies

Several wireless charging methods are under development or available as an aftermarket option in the light-duty automotive market. However, there are not a sufficient number of studies detailing the vehicle integration methods, particularly a complete vehicle integration with higher power levels. This paper presents the design, development, implementation, and vehicle integration of wireless power transfer (WPT)-based electric vehicle (EV) charging systems for various test vehicles. Before having the standards effective, it is expected that WPT technology first will be integrated as an aftermarket retrofitting approach. Inclusion of this technology on production vehicles is contingent upon the release of the international standards. The power stages of the system are introduced with the design specifications and control systems including the active front-end rectifier with power factor correction, high frequency power inverter, high frequency isolation transformer, coupling coils, vehicle side full-bridge rectifier and filter, and the vehicle battery. The operating principles of the control, and communications, systems are presented. Aftermarket conversion approaches including the WPT on-board charger (OBC) integration, WPT CHAdeMO integration, and WPT direct battery connection scenarios are described. Furthermore, the experiments are carried out using the integrated vehicles and the results obtained to demonstrate the system performance including the stage-by-stage efficiencies.

42 ENGINEERING↗

Comparison of Comet Enflow and VA One Acoustic-to-Structure Power Flow Predictions

Comet Enflow is a commercially available, high frequency vibroacoustic analysis software based on the Energy Finite Element Analysis (EFEA). In this method the same finite element mesh used for structural and acoustic analysis can be employed for the high frequency solutions. Comet Enflow is being validated for a floor-equipped composite cylinder by comparing the EFEA vibroacoustic response predictions with Statistical Energy Analysis (SEA) results from the commercial software program VA One from ESI Group. Early in this program a number of discrepancies became apparent in the Enflow predicted response for the power flow from an acoustic space to a structural subsystem. The power flow anomalies were studied for a simple cubic, a rectangular and a cylindrical structural model connected to an acoustic cavity. The current investigation focuses on three specific discrepancies between the Comet Enflow and the VA One predictions: the Enflow power transmission coefficient relative to the VA One coupling loss factor; the importance of the accuracy of the acoustic modal density formulation used within Enflow; and the recommended use of fast solvers in Comet Enflow. The frequency region of interest for this study covers the one-third octave bands with center frequencies from 16 Hz to 4000 Hz.

Grosveld, Ferdinand W.↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Modeling to Support the TREAT Hodoscope System for Fuel Motion Monitoring

Fuel motion is monitored in real time at the Transient Reactor Test Facility (TREAT) using a direct-viewing hodoscope that monitors fast neutrons emitted from test fuel undergoing fission during transients. The hodoscope system is now being refurbished, after over twenty years, to once again support research and development activities examining the survival and failure modes of advanced nuclear reactor fuel systems under accident conditions. An im-portant part of this activity is the development of high-fidelity modeling tools to predict the hodoscope's response to different fuel systems, in different test vehicles, throughout different transient cycles. Initial work has involved the collection of archival data related to how the hodoscope currently at TREAT was manufactured and installed, and the use of this data to create a preliminary radiation transport model using MCNP6. This model is now undergoing refinement to improve its fidelity and to permit its integration with other tools under development to model TREAT transients. The model will be used to study how fast-neutrons measured in the hodoscope's detectors relate to the fission of nuclear material in a test vehicle as a function of location within the vehicle and reactor power. The goal is to develop a time-dependent coupling factor that will relate the measured data to the fuel mass present within each pixel of the hodoscope's field of view. This paper will present the current status of the TREAT hodoscope refurbishment program and modeling activities related to interpreting hodoscope data and inferring fuel motion during transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Power Wireless Charging System Development and Integration for a Toyota RAV4 Electric Vehicle

Several wireless charging methods are underdevelopment or available as an aftermarket option in the light-duty automotive market. However, there are not many studies detailing the vehicle integrations, particularly a complete vehicle integration with higher power levels. This paper presents the development, implementation, and vehicle integration of a high-power (>10 kW) wireless power transfer (WPT)-based electric vehicle (EV) charging system for a Toyota RAV4 vehicle. The power stages of the system are introduced with the design specifications and control systems including the active front-end rectifier with power factor correction (PFC), high frequency power inverter, high frequency isolation transformer, coupling coils, vehicle side full-bridge rectifier and filter, and the vehicle battery. The operating principles of the control, communications, and protection systems are also presented in addition to the alignment and the driver interface system. The physical limitations of the system are also defined that would prevent the system operating at higher levels. The experiments are carried out using the integrated vehicle and the results obtained to demonstrate the system performance including the stage-by-stage efficiencies with matched and interoperable primary and secondary coils.

plug-in electric vehicle charger↗

Microwave to plasma coupling in electron cyclotron resonance and microwave ion sources (invited)

Coupling improvements between microwaves and plasmas are a key factor to design more powerful electron cyclotron resonance and microwave ion sources. On this purpose different activities have been undertaken by the INFN-LNS ion source team and a new approach was developed. Recent experiments confirmed the simulations, demonstrating that even in presence of a dense plasma, resonant modes are excited inside the cavity and the plasma dynamics depends on their structure. An overview of the coupling issues on microwave ion sources is also given along with a discussion on alternative coupling techniques.

43 PARTICLE ACCELERATORS↗

Cavity perturbation techniques for measurement of the microwave conductivity and dielectric constant of a bulk semiconductor material.

Cavity perturbation techniques offer a very sensitive and highly versatile means for studying the complex microwave conductivity of a bulk material. A knowledge of the cavity coupling factor in the absence of perturbation, together with the change in the reflected power and the cavity resonance frequency shift, are adequate for the determination of the material properties. This eliminates the need to determine the Q-factor change with perturbation which may lead to appreciable error, especially in the presence of mismatch loss. The measurement accuracy can also be improved by a proper choice of the cavity coupling factor prior to the perturbation.

Eldumiati, I. I.↗

Design and analysis of a radio frequency extractor in an S-band relativistic klystron amplifier

A radio frequency (RF) extractor converts the energy of a strongly modulated intense relativistic electron beam (IREB) into the energy of high power microwave in relativistic klystron amplifier (RKA). In the aim of efficiently extracting the energy of the modulated IREB, a RF extractor with all round coupling structure is proposed. Due to the all round structure, the operating transverse magnetic mode can be established easily and its resonant property can be investigated with an approach of group delay time. Furthermore, the external quality factor can be low enough. The design and analysis of the extractor applied in an S-band RKA are carried out, and the performance of the extractor is validated with three-dimensional (3D) particle-in-cell simulations. The extraction efficiency reaches 27% in the simulation with a totally 3D model of the whole RKA. The primary experiments are also carried out and the results show that the RF extractor with the external quality factor of 7.9 extracted 22% of the beam power and transformed it into the high power microwave. Better results are expected after the parasitic mode between the input and middle cavities is suppressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical re-injection in cavity-enhanced absorption spectroscopy

Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10{sup −10} cm{sup −1}/√(Hz;) an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling coefficient of gain-guided lasers

An analytical model is presented for the coupling coefficient for two gain-guided coupled waveguides, e.g., semiconductor laser arrays. A common parabolic gain distribution is assumed for the lasers, and the effective dielectric constant distribution is approximated in terms of the bulk refraction index, wavelength, power filling factor, and the antiguiding factor. The fundamental mode is then formulated and used in an integral for the coupling coefficient. The dependence of the coefficient of various waveguide parameters is described.

Katz, J.↗

Analysis of geometric phase effects in the quantum-classical Liouville formalism

We analyze two approaches to the quantum-classical Liouville (QCL) formalism that differ in the order of two operations: Wigner transformation and projection onto adiabatic electronic states. The analysis is carried out on a two-dimensional linear vibronic model where geometric phase (GP) effects arising from a conical intersection profoundly affect nuclear dynamics. We find that the Wigner-then-Adiabatic (WA) QCL approach captures GP effects, whereas the Adiabatic-then-Wigner (AW) QCL approach does not. Moreover, the Wigner transform in AW-QCL leads to an ill-defined Fourier transform of double-valued functions. The double-valued character of these functions stems from the nontrivial GP of adiabatic electronic states in the presence of a conical intersection. In contrast, WA-QCL avoids this issue by starting with the Wigner transform of single-valued quantities of the full problem. As a consequence, GP effects in WA-QCL can be associated with a dynamical term in the corresponding equation of motion. Since the WA-QCL approach uses solely the adiabatic potentials and non-adiabatic derivative couplings as an input, our results indicate that WA-QCL can capture GP effects in two-state crossing problems using first-principles electronic structure calculations without prior diabatization or introduction of explicit phase factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A nodal transport method for coupled fast-thermal reactor analysis

We report that for efficient core analyses of coupled fast-thermal reactors, a new deterministic method has been developed based on the variational nodal transport method of VARIANT. A new multigroup cross section generation procedure was devised by combining Monte Carlo lattice calculations for thermal assemblies and the two-step procedure of the MC 2 -3 code for fast assemblies. To reduce assembly homogenization errors in nodal transport calculations, a new nodal equivalence method was developed based on the partial current discontinuity factor (PCDF) and incorporated in VARIANT. A practical procedure to calculate PCDFs with fixed source supercell calculations was also devised. The performance of the proposed method was investigated using a test problem derived from the versatile coupled test reactor (VCTR) design. The new procedure produced multigroup cross sections accurately for all assemblies. VARIANT transport calculations with PCDFs produced accurate multiplication factor and power distribution compared to reference Serpent-2 Monte Carlo solutions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The fundamental power coupler and pick-up of the 56 MHz SRF cavity for RHIC

A fundamental power coupler (FPC) is designed to provide fast tuning the 56MHz SRF cavity in RHIC. The FPC will be inserted from one of the chemical cleaning ports at the rear end of the cavity with magnetic coupling to the RF field. The size and the location of the FPC are decided based on the required operational external Q of the cavity. The cavity is beam driven, and the FPC is designed with variable coupling that would cover a range of power levels. It is thermally isolated from the base temperature of the cavity, which is 4.2K. A 1kW power amplifier will be used to close an amplitude control feedback loop. In this paper, we discuss the coupling factor of the FPC with the chosen design.

43 PARTICLE ACCELERATORS↗