Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Management and Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Brief Survey on High Performance Computing Systems Power Management

This paper provides a survey of software-based power management techniques in High Performance Computing (HPC) systems. Seven existing power management and monitoring tools and frameworks are discussed. These are: Variorum, dynamic energy-performance optimizer (DEPO), Powersched, Bull Dynamic Power Optimizer (BDPO), Energy Aware Runtime (EAR), Global Extensible Open Power Manager (GEOPM), and PoLiMEr. Each of these tools is evaluated based on hardware abstraction, optimization methods, usability, and experimental validation. This survey highlights the diversity of approaches in managing energy efficiency, from vendor-neutral APIs to algorithm-driven power capping, and dynamic frequency adjustments. Given that energy requirements for large computational systems is increasing quickly, the importance of integrating these tools into existing HPC environments and the need for further research in this rapidly evolving field is also discussed.

97 - MATHEMATICS AND COMPUTING↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

A Modular Conjugate Heat Transfer Optimization Framework for Thermal Management of Electric Aircraft

Conjugate heat transfer (CHT) analysis and optimization is a powerful method for improving thermal management, as it simultaneously resolves the temperature distribution in both fluid and solid domains. This paper presents a modular, discrete adjoint-based CHT optimization capability integrated within the OpenMDAO/MPhys framework. A unique feature of the proposed framework is its flexibility to extend to multidisciplinary optimization, including aero-structural-thermal applications. The fluid domain is modeled using a finite-volume Computational Fluid Dynamics (CFD) solver, and the solid domain with a conduction heat transfer solver. A mixed Neumann-Dirichlet boundary condition is developed to enable full submersion of the solid geometry within the fluid domain, while ensuring consistent temperature and heat flux coupling at the CHT interface. Gradient-based optimization is performed; the gradients are efficiently computed using the discrete adjoint solvers implemented in DAFoam. To demonstrate the method, this paper considers two cases related to electric aircraft thermal management: a U-bend heat exchanger and an actively cooled battery pack. The U-bend case aims to minimize pressure loss while maximizing heat flux by changing the pipe geometry. The optimized design reduces pressure loss by 52.7% and increases total heat flux by 2.3%. In the battery pack case, a 3-by-3 cell configuration is cooled by ambient airflow, with constant heat generation prescribed in the cells. The battery casing shape serves as the design variable, and the objective function is a weighted sum of pressure loss and pack weight, subject to a maximum temperature constraint. The optimized design achieves a 44.6% reduction in pressure loss and a 1.5% reduction in weight, while satisfying the thermal constraint. To ensure the reliability of the optimized designs, this study validates coarse-mesh, steady-state predictions against fine-mesh unsteady simulations, demonstrating consistency within acceptable errors. This work demonstrates the potential of the developed framework to enable rapid, high-fidelity design of thermal management systems for electric aircraft.

heat transfer↗

Optimal Water-Power Flow Problem: Formulation and Distributed Optimal Solution

This paper formalizes an optimal water-power flow (OWPF) problem to optimize the use of controllable assets across power and water systems while accounting for the couplings between the two infrastructures. Tanks and pumps are optimally managed to satisfy water demand while improving power grid operations; {for the power network, an AC optimal power flow formulation is augmented to accommodate the controllability of water pumps.} Unfortunately, the physics governing the operation of the two infrastructures and coupling constraints lead to a nonconvex (and, in fact, NP-hard) problem; however, after reformulating OWPF as a nonconvex, quadratically-constrained quadratic problem, a feasible point pursuit-successive convex approximation approach is used to identify feasible and optimal solutions. In addition, a distributed solver based on the alternating direction method of multipliers enables water and power operators to pursue individual objectives while respecting the couplings between the two networks. The merits of the proposed approach are demonstrated for the case of a distribution feeder coupled with a municipal water distribution network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Safety Injection Flow Map Associated with Target RCS Depressurization to Maintain Core Coolability of OPR1000

In Korea, Severe Accident Management Guidance (SAMG) for Optimized Power Reactor (OPR1000) has been developed through the research results related to the WOG SAMG, in which the operation phase shifts from the Emergency Operation Procedure (EOP) to the SAMG when the Core Exit Temperature (CET) reaches 923 K. Among 7 mitigation strategies envisioned, the third management strategy, injecting coolant into Reactor Coolant System (RCS) by depressurizing the RCS is one of the key strategies to fortify the in-vessel retention capability. As an aid to such mitigation strategy, a safety injection (SI) flow map has been developed by Lee et al. for predicting required flow rate associated with target RCS depressurization to recover in-vessel coolability. The mechanistic SI flow map used the CET increase rate and core water level decrease rate obtained from MELCOR code simulation. It should be noted that during the severe accident, the total heat generated is sum of the decay heat and the oxidation heat. Thus, it is necessary to consider additional heat sources by oxidation reaction between cladding, structure, control rod, and hot steam prior to the injection of coolant. It was believed that the SI model estimated required flow rate rather conservatively by considering the expected amount decay heat and the accumulated heat in the core based on the RCS pressure. However, it was confirmed that the SI model developed by Lee et al. could not represent the total heat removal especially since start of oxidation. Under transient conditions, the heat sources accumulated in the heat structures (fuel, cladding, supporting structures) should be embarked in the model for accurate contribution of the total heat source to the required flow rate. Therefore, the objective of this study is to improve the previous SI flow map predicting the injection flow rate associated with target RCS depressurization to satisfy the in-vessel coolability during severe accidents. Additional terms were developed to reflect accurate heat accumulating and included in the existing model. Resulting SI flow map includes the target RCS depressurization, which enables discharge of the required flow rate by utilizing the flow rate-pressure curve with operation of two high pressure safety injections (HPSIs). Also recent MELCOR simulation result of a postulated steam generator tube rupture (SGTR) accident verified the accuracy of the improved map.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the Moon to Stay: Challenges Presented to Power Electronics Technology by Sustained Operations on the Lunar Surface

NASA’s Artemis Program seeks not only to return humans to the Moon for the first time since the 1970’s but also to provide the technological basis for infrastructure that will enable permanent and expanding scientific and industrial exploitation of the Lunar surface. The primary purpose of this infrastructure is to generate and distribute power to a diverse and growing range of scientific and industrial assets, and the keys to success for this function are power management and control circuits that are highly reliable and maintainable for a decade of operation in the extreme thermal, radiation, and dust environment of the Lunar surface. While various combinations of wide band gap semiconductors, electronic devices, circuit topologies, and shielding schemes have been successfully developed for mission environments ranging from low Earth orbit to the Jovian system, power management technology has not been optimized to meet the full combination of mission requirements for the Lunar surface. To accomplish this, NASA requests the dedicated focus of the power electronics industry.

semiconductors↗

Operational and Strategic Implementation of Dynamic Line Rating for Optimized Wind Energy Generation Integration

One primary goal of rendering today’s transmission grid “smarter” is to optimize and better manage its power transfer capacity in real time. Power transfer capacity is affected by three main elements: stability, voltage limits, and thermal ratings. All three are critical, but thermal ratings represent the greatest opportunity to quickly, reliably and economically utilize the grid’s true capacity. With the “Smarter Grid”, new solutions have been sought to give operators a better grasp on real time conditions, allowing them to manage and extend the usefulness of existing transmission infrastructure in a safe and reliable manner. The objective of the INL Wind Program is to provide industry a Dynamic Line Rating (DLR) solution that is state of the art as measured by cost, accuracy and dependability, to enable human operators to make informed decisions and take appropriate actions without human or system overloading and impacting the reliability of the grid. In addition to mitigating transmission line congestion to better integrate wind, DLR also offers the opportunity to improve the grid with optimized utilization of transmission lines to relieve congestion in general. As wind-generated energy has become a bigger part of the nation’s energy portfolio, researchers have learned that wind not only turns turbine blades to generate electricity, but can cool transmission lines and increase transfer capabilities significantly, sometimes up to 60 percent. INL’s DLR development supports EERE and The Wind Energy Technology Office’s goals by informing system planners and grid operators of available transmission capacity, beyond typical Static Line Ratings (SLR). SLRs are based on a fixed set of conservative environmental conditions to establish a limit on the amount of current lines can safely carry without overheating. Using commercially available weather monitors mounted on industry informed custom brackets developed by INL in combination with Computational Fluid Dynamics (CFD) enhanced weather analysis and DLR software, INL’s project offers the potential of safely providing line ampacities up to 40 percent or more above existing SLRs, by using real time information rather than overly conservative SLR.

17 WIND ENERGY↗

Unifying Energy-Management Problems for Inverter-Based Power Networks

This paper outlines a suite of energy-management problems for inverter-based power networks from the vantage point of optimal control and (non)linear optimization. The problems are categorized based on timescales dictated by the network dynamics, and organized methodologically based on the problem complexity. A growing body of literature has addressed problems in this domain, albeit, with poorly motivated assumptions and behavioral models that obscure precise device behavior. With a combination of circuit- and control-theoretic lenses, we establish appropriate dynamic models for the networked resources, illustrate how common engineering assumptions arise, uncover how problems are linked, and postulate open challenges.

(non)linear optimization↗

Literature Survey on Operational Voltage Control and Reactive Power Management on Transmission and Sub-Transmission Networks

Voltage and reactive power system control is generally performed following usual patterns of loads, based on off-line studies for daily and seasonal operations. This practice is currently challenged by the inclusion of distributed renewable generation, such as solar. There has been focus on resolving this problem at the distribution level; however, the transmission and sub-transmission levels have received less attention. This paper provides a literature review of proposed methods and solution approaches to coordinate and optimize voltage control and reactive power management, with an emphasis on applications at transmission and sub-transmission level. The conclusion drawn from the survey is that additional research is needed in the areas of optimizing switch shunt actions and coordinating all available resources to deal with uncertain patterns from increasing distributed renewable generation in the operational time frame. These topics are not deeply explored in the literature.

capacitors↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Distributed wireless sensing for fugitive methane leak detection

Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It is demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.

04 OIL SHALES AND TAR SANDS↗

Distributed wireless sensing for methane leak detection technology

Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It is demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel cells, batteries and super-capacitors stand-alone power systems management using optimal/flatness based-control

In this work, an optimal control (under constraints) based on the Pontryagin’s maximum principle is used to optimally manage energy flows in a basic PEM (Proton Exchange Membrane) fuel cells system associated to lithium-ion batteries and supercapacitors through a common DC bus having a voltage to stabilize using the differential flatness approach. The adaptation of voltage levels between different sources and load is ensured by use of three DC-DC converters, one boost connected to the PEM fuel cells, while the two others are buck/boost and connected to the lithiumion batteries and supercapacitors. The aim of this paper is to develop an energy management strategy that is able to satisfy the following objectives: Impose the power requested by a habitat (representing the load) according to a proposed daily consumption profile, Keep fuel cells working at optimal power delivery conditions, Maintain constant voltage across the common DC bus, Stabilize the batteries voltage and stored quantity of charge at desired values given by the optimal control. Results obtained under MATLAB/Simulink environment prove that the cited objectives are satisfied, validating then, effectiveness and complementarity between the optimal and flatness concepts proposed for energy management. Note that this study is currently in experimentally validation within MSE Laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing Wildfire Risk and Promoting Equity through Optimal Configuration of Networked Microgrids

As climate change increases the risk of large-scale wildfires, wildfire ignitions from electric power lines are a growing concern. To mitigate the wildfire ignition risk, many electric utilities de-energize power lines to prevent electric faults and failures. These preemptive power shutoffs are effective in reducing ignitions, but they could result in wide-scale power outages. Advanced technology, such as networked microgrids, can help reduce the size of the resulting power outages; however, even microgrid technology might not be sufficient to supply power to everyone, thus forcing hard questions about how to prioritize the provision of power among customers. In this paper, we present an optimization problem that configures networked microgrids to manage wildfire risk while maximizing the power served to customers; however, rather than simply maximizing the amount of power served in kilowatts, our formulation also considers the ability of customers to cope with power outages, as measured by social vulnerability, and it discourages the disconnection of particularly vulnerable customer groups. To test our model, we leverage a synthetic but realistic distribution feeder, along with publicly available social vulnerability indices and satellite-based wildfire risk map data, to quantify the parameters in our optimal decision-making model. Our case study results demonstrate the benefits of networked microgrids in limiting load shed and promoting equity during scenarios with high wildfire risk.

distribution systems↗