Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power System Dynamic State Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Master State Distributed Estimator (masde)

The MSE technology provides a distributed state estimation scheme for power utilities by making it a real time dynamic system, versus the static snapshot method used today. This will allow utilities to verify power grid readings and identify false data on the communication network. The prevailing method of estimation takes all the data from the system into a single load flow equation at the utilities command center. This becomes a large algorithm that is very time consuming to solve, providing the engineers only snap shots of the system. The MFD distributes an algorithm to devises that are already installed at various locations on the power grid. This allows for much faster computer times because the algorithms contain magnitudes less data. When each distributed estimator completes its calculation, it sends the results back to the master device to check against all other distributed estimators.

Reen, DylanW.↗

Phasor Measurement Unit and Its Application in Modern Power Systems

The introduction of phasor measuring units (PMUs) in power systems significantly improves the possibilities for monitoring and analyzing power system dynamics. Synchronized measurements make it possible to directly measure phase angles between corresponding phasors in different locations within the power system. Improved monitoring and remedial action capabilities allow network operators to utilize the existing power system in a more efficient way. Improved information allows fast and reliable emergency actions, which reduces the need for relatively high transmission margins required by potential power system disturbances. In this chapter, the applications of PMU in modern power systems are presented. Specifically, the topics touched in this chapter include state estimation, voltage and transient stability, oscillation monitoring, event and fault detection, situation awareness, and model validation. A case study using Characteristic Ellipsoid method based on PMU to monitor power system dynamic is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PMU Placement for Dynamic State Tracking of Power Systems

Accurately tracking the state variables (rotor angle and speed) is a necessity for monitoring system stability conditions and assessing the risks of large-scale system collapse. This paper explores how the number and locations of PMUs installed in the system are determined to ensure satisfactory state tracking performance. A search algorithm is presented for determining PMU placement (location and quantity). The algorithm determines a placement that gives small tracking error in polynomial time. A modified, scalable algorithm is also presented. Observability in the presence of faults is considered. Simulation results for a 16-machine and a 50-machine system are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capturing Dynamics in the Power Grid: Formulation of Dynamic State Estimation through Data Assimilation

With the increasing complexity resulting from uncertainties and stochastic variations introduced by intermittent renewable energy sources, responsive loads, mobile consumption of plug-in vehicles, and new market designs, more and more dynamic behaviors are observed in everyday power system operation. To operate a power system efficiently and reliably, it is critical to adopt a dynamic paradigm so that effective control actions can be taken in time. The dynamic paradigm needs to include three fundamental components: dynamic state estimation; look-ahead dynamic simulation; and dynamic contingency analysis (Figure 1). These three components answer three basic questions: where the system is; where the system is going; and how secure the system is against accidents. The dynamic state estimation provides a solid cornerstone to support the other 2 components and is the focus of this study.

97 MATHEMATICS AND COMPUTING↗

Pre-Commercial Demonstration of Direct Non-Iterative State Estimator (DNSE+)

The objective of this DOE co-funded project is to demonstrate functionality and performance of a production-grade Direct Non-iterative State Estimator (DNSE) through its integration with NYPA’s Energy Management System (EMS) and an enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). A production-grade DNSE aims to overcome a major obstacle to the operational use of synchrophasor data in Synchro-Phasor Management Systems (SPMS) by providing SPMS applications with a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, the DNSE uses synchrophasor measurements and Supervisory Control and Data Acquisition (SCADA) measurements, together with the complete power system model, to simultaneously obtain the complete state of the entire utility’s operating model at rates that are close to the synchrophasor data rates. The full system coverage property is what distinguishes the DNSE from the linear synchrophasor SEs (which cover only parts of the operating model that are visible through synchrophasor measurements), and DNSE differs from traditional EMS SE in that the solution is obtained without iterations, without initial values (hence the “direct” in the name), and at a much higher execution rate. This presentation provides an overview of the project objectives, a brief description of the main tasks including the development work to productize and optimize DNSE from its current MATLAB code base, RTDMS enhancement for interfacing with the DNSE, factory acceptance testing, field installation, testing and demonstration, as well as the current status of the project execution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Framework Combining Model-Based and Data-Driven Methods for Hierarchical Decentralized Robust Dynamic State Estimation: Preprint

This paper combines model-based and data-driven methods to develop a hierarchical decentralized robust dynamic state estimator (DSE). A two-level hierarchy is proposed, where the lower level is comprised of robust model-based decentralized DSEs. The state estimates sent from the lower level are received at the upper level, where they are filtered by a robust data- driven DSE, after a principled sparse selection. This selection allows us to shrink the dimension of the problem at the upper level, and hence to speed up the computational time significantly. The proposed hybrid framework does not depend upon the centralized infrastructure of the control centers, thus it can be completely embedded into the wide-area measurement systems. This feature will ultimately facilitate the placement of hierarchical decentralized control schemes at the phasor data concentrator (PDC) locations. Also, the network model is not necessary, thus a topology processor is not required. Finally, there is no assumption on the dynamics of the electric loads. The proposed framework is tested on a 2000-bus network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Framework Combining Model-Based and Data-Driven Methods for Hierarchical Decentralized Robust Dynamic State Estimation

This paper combines model-based and data-driven methods to develop a hierarchical, decentralized, robust dynamic state estimator (DSE). A two-level hierarchy is proposed, where the lower level consists of robust, model-based, decentralized DSEs. The state estimates sent from the lower level are received at the upper level, where they are filtered by a robust data-driven DSE after a principled sparse selection. This selection allows us to shrink the dimension of the problem at the upper level and hence significantly speed up the computational time. The proposed hybrid framework does not depend on the centralized infrastructure of the control centers; thus it can be completely embedded into the wide-area measurement systems. This feature will ultimately facilitate the placement of hierarchical decentralized control schemes at the phasor data concentrator locations. Also, the network model is not necessary; thus, a topology processor is not required. Finally, there is no assumption on the dynamics of the electric loads. The proposed framework is tested on the 2,000-bus synthetic Texas system, and shown to be capable of reconstructing the dynamic states of the generators with high accuracy, and of forecasting in the advent of missing data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Full State Feedback Control for Virtual Power Plants

This report presents an object-oriented implementation of full state feedback control for virtual power plants (VPP). The components of the VPP full state feedback control are (1) objectoriented high-fidelity modeling for all devices in the VPP; (2) Distribution System Distributed Quasi-Dynamic State Estimation (DS-DQSE) that enables full observability of the VPP by augmenting actual measurements with virtual, derived and pseudo measurements and performing the Quasi-Dynamic State Estimation (QSE) in a distributed manner, and (3) automated formulation of the Optimal Power Flow (OPF) in real time using the output of the DS-DQSE, and solving the distributed OPF to provide the optimal control commands to the DERs of the VPP.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimate the Electromechanical States Using Particle Filtering and Smoothing

Accurate knowledge of electromechanical states is critical for efficient and reliable control of a power system. This paper proposes a particle filtering approach to estimate the electromechanical states of power systems from Phasor Measurement Unit (PMU) data. Without having to go through laborious linearization procedure, the proposed particle filtering techniques can estimate states of a complex power system, which is often non-linear and has non-Gaussian noise. The proposed method is evaluated using a multi-machine system with both large and small disturbances. Sensitivity studies of the dynamic state estimation performance are also presented to show the robustness of the proposed method. The inherent decoupling properties of particle filtering make it highly scalable and the potential to reduce computational time through parallel implementation is very promising.

Auxiliary Particle Filter↗

A General Decentralized Dynamic State Estimation With Synchronous Generator Magnetic Saturation

We report the saturation of the nonlinear magnetic circuit of synchronous generators is often neglected when performing Kalman filter-based dynamic state estimation (DSE), yielding significant estimation bias. This letter addresses this problem and proposes a generalized DSE framework to handle magnetic saturation. Moreover, this letter derives a state initialization procedure that improves the Kalman filter tracking speed. The framework is flexible in dealing with different saturation functions and generator models. Numerical results on the Texas 2000-bus system verify the effectiveness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis with Different Computing Environments

Contingency analysis is a key function in the Energy Management System (EMS) to assess the impact of various combinations of power system component failures based on state estimation. Contingency analysis is also extensively used in power market operation for feasibility test of market solutions. High performance computing holds the promise of faster analysis of more contingency cases for the purpose of safe and reliable operation of today’s power grids with less operating margin and more intermittent renewable energy sources. This paper evaluates the performance of counter-based dynamic load balancing schemes for massive contingency analysis under different computing environments. Insights from the performance evaluation can be used as guidance for users to select suitable schemes in the application of massive contingency analysis. Case studies, as well as MATLAB simulations, of massive contingency cases using the Western Electricity Coordinating Council power grid model are presented to illustrate the application of high performance computing with counter-based dynamic load balancing schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of plasma properties using an extended Kalman filter with plasma global models

A physically-constrained extended Kalman filter (EKF) is applied to various zero-dimensional global models for the estimation of plasma properties using time-dependent experimental data such as the plasma density or ion flux. The capability of the EKF is demonstrated to estimate unknown system states simultaneously, such as reaction rate coefficients and the absorbed electron input power, which can be difficult, if not impossible, to measure experimentally. Global models accounting for pure argon reactions and argon-oxygen reactions are used in this work to demonstrate the ability of the filter to estimate dynamic and complex systems. Furthermore, the results obtained from the EKF plasma global model illustrate that model-data fusion techniques can be used to estimate plasma properties and processes for time-varying systems, such as pulsed discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid approach for estimating dynamic states of synchronous generators

Accurate and robust estimation of dynamic states is essential for monitoring and controlling a power grid. To achieve higher accuracy and robustness, this paper proposes a hybrid estimation approach to estimate the dynamic states of synchronous generators using multiple models, classified into a set of local models and a wide-area model. The proposed estimation approach, first, estimates dynamic states using the extended Kalman filter (EKF) based on a local model and a wide-area model. Then, at each time step, probability indexes, which quantify the likelihood of both local and wide-area models, are determined using hypothesis testing based on measurements innovations. Finally, using the weighted fix approach, the states estimated from the local and wide-area models are combined based on their probability indexes. Simulation studies using the two-area four-machine system shows that the proposed approach can improve estimation accuracy and increase robustness against model errors.

Akhlaghi, Shahrokh↗

Dynamic Parameter Estimation with Physics-based Neural Ordinary Differential Equations

Accurate estimation of dynamic parameters of gen-erators is crucial to building a reliable model for dynamical studies and reliable operation of the power system. This paper develops a physics-based neural ordinary differential equations (ODE) approach to learn the parameters of generator dynamic model using phasor measurement units (PMU) data. We design a physics-based neural network to represent the swing equations of the power system dynamics. A loss function is defined as the difference between dynamic simulation results from the physics-based neural networks and pseudo PMU measurements. The parameters of generator dynamic model are iteratively updated using the neural ODEs and the adjoint method. By exploiting the mini-batch scheme in neural ODE training, the parameter estimation performance is significantly improved. Numerical study results on a 3-machine 9-bus system show that the proposed algorithm outperforms state-of-the-art baseline method in both computation time and dynamic parameter estimation accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Prediction of Power System Frequency in FNET: A State Space Approach

This paper proposes a novel approach to predict power frequency by applying a state-space model to describe the time-varying nature of power systems. It introduces the Expectation maximization (EM) and prediction error minimization (PEM) algorithms to dynamically estimate the parameters of the model. This paper discusses how the proposed models can be used to ensure the efficiency and reliability of power systems in Frequency Monitoring Network (FNET), if serious frequency fluctuation or measurement failure occur at some nodes; this is achieved without requiring the exact model of complex power systems. Our approach leads to an easy online implementation with high precision and short response time that are key to effective frequency control. We randomly pick a set of frequency data for one power station in FNET and use it to estimate and predict the power frequency based on past measurements. Several computer simulations are provided to evaluate the method. Simulation results showed that the proposed technique could achieve good performance regarding the frequency monitoring with very limited measurement input information.

Djouadi, Seddik M↗

High-Performance Computing for Real-Time Grid Analysis and Operation

Power grids worldwide are undergoing an unprecedented transition as a result of grid evolution meeting information revolution. The grid evolution is largely driven by the desire for green energy. Emerging grid technologies such as renewable generation, smart loads, plug-in hybrid vehicles, and distributed generation provide opportunities to generate energy from green sources and to manage energy use for better system efficiency. With utility companies actively deploying these technologies, a high level of penetration of these new technologies is expected in the next 5-10 years, bringing in a level of intermittency, uncertainties, and complexity that the grid did not see nor design for. On the other hand, the information infrastructure in the power grid is being revolutionized with large-scale deployment of sensors and meters in both the transmission and distribution networks. The future grid will have two-way flows of both electrons and information. The challenge is how to take advantage of the information revolution: pull the large amount of data in, process it in real time, and put information out to manage grid evolution. Without addressing this challenge, the opportunities in grid evolution will remain unfulfilled. This transition poses grand challenges in grid modeling, simulation, and information presentation. The computational complexity of underlying power grid modeling and simulation will significantly increase in the next decade due to an increased model size and a decreased time window allowed to compute model solutions. High-performance computing is essential to enable this transition. The essential technical barrier is to vastly increase the computational speed so operation response time can be reduced from minutes to seconds and sub-seconds. The speed at which key functions such as state estimation and contingency analysis are conducted (typically every 3-5 minutes) needs to be dramatically increased so that the analysis of contingencies is both comprehensive and real time. An even bigger challenge is how to incorporate dynamic information into real-time grid operation. Today’s online grid operation is based on a static grid model and can only provide a static snapshot of current system operation status, while dynamic analysis is conducted offline because of low computational efficiency. The offline analysis uses a worst-case scenario to determine transmission limits, resulting in under-utilization of grid assets. This conservative approach does not necessarily lead to reliability. Many times, actual power grid scenarios are not studied, and they will push the grid over the edge and resulting in outages and blackouts. This chapter addresses the HPC needs in power grid analysis and operations. Example applications such as state estimation and contingency analysis are given to demonstrate the value of HPC in power grid applications. Future research directions are suggested for high performance computing applications in power grids to improve the transparency, efficiency, and reliability of power grids.

Contingency Analysis↗