Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Power Performance Test Report for the SWIFT Wind Turbine

This report summarizes the results of a power performance test that NREL conducted on the SWIFT wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 12: Power Performance Measurements of Electricity Producing Wind Turbines, IEC 61400-12-1 Ed.1.0, 2005-12. However, because the SWIFT is a small turbine as defined by IEC, NREL also followed Annex H that applies to small wind turbines. In these summary results, wind speed is normalized to sea-level air density.

17 WIND ENERGY↗

Power Performance Test Report for the Viryd CS8 Wind Turbine

This report contains the results of the power performance test that was performed on a Viryd CS8 wind turbine as part of the DOE Independent Testing project. The test is an accredited test to the IEC 61400-12-1 power performance standard.

17 WIND ENERGY↗

Wireless power transfer test system

A testing system for wireless power transfer systems, including a stationary plate, a rotating plate, and a driver to rotate the rotating plate with respect to the stationary plate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wave Energy Prize - 1/20th Testing - Oscilla Power Triton Point Absorber

Data from the 1/20th scale testing data completed on the Wave Energy Prize for the Oscilla Power team, including the 1/20th Test Plan, raw test data, video, photos, and data analysis results. The top level objective of the 1/20th scale device testing is to obtain the necessary measurements required for determining Average Climate Capture Width per Characteristic Capital Expenditure (ACE) and the Hydrodynamic Performance Quality (HPQ), key metrics for determining the WEPrize winners.

1/20th scale↗

Feasibility of Power Ramp Testing in the Advanced Test Reactor

For decades, the Halden Boiling Water Reactor (HBWR) in Norway was an international resource for assessing nuclear fuels and materials behavior and its unexpected shutdown in 2018 represented a significant loss in experimental capability for prototypical irradiation testing. In the aftermath of the closure, a study was performed to assess capability gaps related to the Accident Tolerant Fuels (ATF) program. It was concluded that the primary capability gaps left by the closure of the HBWR were the loss of prototypic in-pile Light Water Reactor (LWR) loops that provide operational transient testing and in-pile Loss-of-Coolant Accident (LOCA) testing capabilities. The study also concluded that the Advanced Test Reactor (ATR) and Transient Reactor Test Facility (TREAT) likely have the necessary key capabilities to absorb the breadth of the HBWR mission gaps related to the ATF program, but additional investments in experimental infrastructure were needed. One such investment is the design and installation of additional pressurized water loops in the medium-I positions of the ATR, hereafter referred to as I-Loops, to support power ramp testing and testing in Boiling Water Reactor (BWR) conditions. This paper gives an overview of the planned ATR I-Loops and assesses the feasibility of performing power ramp testing inside such a loop.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating the X2 initial core zero power physics tests with Serpent-Ants

The validation of the Ants nodal neutronics code for VVER applications is started by modelling the zero power physics tests for the initial core of the Khmelnitsky 2 nuclear power plant as described in the X2 benchmark using the Serpent-Ants two step neutronics calculation chain. The Ants prediction compare favorably against an earlier continuous energy Monte-Carlo reference solution as well as the measured data, except for discrepancies in the SCRAM worth between predicted and measured values. Similar discrepancies have been previously reported for VVER-1000 reactors, and the Ants predicted SCRAM worths match well with the Serpent results. Additionally, the assembly power distribution and axial power distribution predicted by Ants for the critical HZP state of the reactor are also compared to a reference Serpent solution with very good results. Lastly, an investigation into the effects of the few-group structure used in the nodal calculations and the use or lack of leakage correction for group constants on the results shows that the best accuracy is reached with seven or eight energy groups without leakage correction, although a reasonable accuracy can also be obtained with two or three energy groups using fundamental mode leakage correction. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wave Energy Prize - 1/50th Testing - Oscilla Power Triton Point Absorber

This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the Oscilla Power team, and includes: - 1/50th test data (raw & processed) - 1/50th test data video and pictures - 1/50th Test plans and testing documents - SSTF_Submission (summarized results)

1/50th scale↗

Wave Energy Prize - 1/50th Testing - Principle Power Oscillating Water Column

This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the Principle Power team, and includes: - 1/50th test data (raw & processed) - 1/50th test data video and pictures - 1/50th Test plans and testing documents - SSTF_Submission (summarized results)

1/50th scale↗

Divertor Component Testing

Power exhaust is an immense challenge in tokamaks. Commonwealth Fusion Systems (CFS), in collaboration with MIT and others, is working on the design of a compact (R 0 = 1.85 m), high-field (B 0 = 12 T) tokamak for the demonstration of net fusion energy, called SPARC. Empirical scaling laws indicate that the unmitigated heat flux in the boundary plasma will exceed 10 GW/m 2 . Such high heat fluxes will be a formidable challenge. The scope of this work is to utilize the HHF testing expertise maintained by ORNL, used in support of NSTX-U and to demonstrate the thermal performance of tungsten-coated graphitic foam targets, to help CFS and its collaborators to assess the performance of (1) base materials (tungsten and its alloys) and (2) divertor mockups under SPARC-like divertor heat flux conditions. These activities will be performed by ORNL personnel using electron beam exposure facilities at the Pennsylvania State University’s Applied Research Laboratory (ARL). ARL is a Department of Defense University Affiliated Research Center where ORNL has successfully executed NSTX-U and graphitic foam high heat flux testing using electron beam (e-beam) facilities, which is a nonstandard service. For the assessment of base materials, CFS will do an initial thermal analysis, in consultation with ORNL, to understand under what scenarios the materials are most likely to fail. CFS will supply to ORNL various tungsten-based material samples to test with testing taking 3 weeks. ORNL will thermally stress the samples under SPARC divertor-like conditions to either failure or to a prescribed number of pulses. ORNL will record experimental data, including IR surface temperature and embedded thermocouple readings, and report results to CFS

36 MATERIALS SCIENCE↗

Status of the OECD/NEA Watts Bar unit 1 benchmark and calculations of local reactor core power data of the Zero Power physics tests

The paper aims to provide an update on the status of the Organization for Economic Cooperation and Development (OECD) / the Nuclear Energy Agency (NEA) Tennessee Valley Authority (TVA) Watts Bar 1 (WB1) Multi-Physics Multi-Cycle depletion benchmark and the results associated with Exercise 1. The benchmark relies on the set of benchmark progression problems developed by the Department of Energy (DOE) Consortium for the Advanced Simulation of Light Water Reactors (CASL) for the Virtual Environment for Reactor (VERA), which are based on real plant design and operational data. The OECD/NEA TVA WB1 benchmark is designed for validation of both traditional and novel high-fidelity multi-physics codes to analyze Pressurized Water Reactors (PWR) depletion cycles. The activities are conducted under the Expert Group on Reactor Systems Multi-Physics (EGMUP) at NEA/OECD. In this work, we analyze Exercise 1 of the benchmark: stand-alone Three-Dimensional (3D) neutronics at Start-up Zero Power Physics Test (ZPPT) at Hot Zero Power Conditions (HZP) and the resulting power maps. The code used to model the exercise is the continuous energy Monte Carlo code Serpent 2.1.31 along with the nuclear data library ENDF/B-VII.1. Serpent results are compared with the high-fidelity deterministic code MPACT, which is part of VERA. The paper presents three selected results from power calculations required output. The results compared are the normalized axially integrated radial core power maps, the normalized axial averaged core power shapes, and the normalized core hottest and coldest assemblies radial power maps. The Root Mean Square Deviation (RMSD) between Serpent and MPACT is 0.51 % for the axially integrated radial core power map, 1.41 % for the axial averaged core power shape, 2.42 % for the hottest assembly axial power shape, 0.88 % for the coldest assembly axial integrated hottest assembly radial pin power map, and 0.17 % for the axially integrated coldest assembly radial pin power map. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power Plant Testing of Ultrasonic Measurements of Temperature Distributions and Heat Fluxes to Heat Exchange Surfaces

Extreme environmental conditions are common in energy conversion applications, in which the most hardened insertion sensors often do not perform reliably for long. On the other hand, ultrasonic measurements can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. This paper outlines the testing results of this approach applied to the temperature distribution measurements to a waterwall of a 500 MW power-plant utility boiler. The validation results obtained over the prolonged power plant test show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Walton, Kenneth↗

Deployment of Advanced Electroanalytical Sensors in the Kairos Power Engineering Test Unit (ETU) (Final CRADA Report)

This document serves as a summary report for the work conducted under CRADA 2022-22119 between Argonne National Laboratory and Kairos Power LLC. As part of this project, Argonne and Kairos worked to develop an advanced electrochemical system and testing protocol for the Kairos Power Enineering Test Unit (ETU), an industrial scale 14 ton molten FLiBe salt system. The main goals were (1) measurements of fundamental properties for key salt species, (2) the deployment and operations of sensors in the ETU, and (3) the development of automated approaches to analyze the measurements.

42 ENGINEERING↗

Real-Time Digital Simulation of Inertial Response with Hardware-in-the-Loop Implementation on the CART3 Wind Turbine at the National Wind Technology Center

With increasing penetrations of wind power on electric grids, the stability and reliability of interconnected power systems may be impacted. In some countries that have developed renewable energy sources and systems, grid codes have been revised to require wind power plants (WPPs) to provide ancillary services to support the power system frequency in case of severe grid events. To do this, wind turbine generators (WTGs) should be deloaded to reserve a certain amount of active power for primary frequency response; however, deloading curtails annual energy production, and the market for this type of service needs to be further developed. In this report, we focus on the temporary frequency support provided by WTGs through inertial response. WTGs have potential to provide inertial response, but appropriate control methods should be implemented. With the implemented inertial control methods, wind turbines are capable of increasing their active power output by releasing some of their stored kinetic energy when a frequency excursion occurs. Active power can be temporarily boosted above the maximum power points, after which the rotor speed decelerates, and subsequently an active power output reduction restores the kinetic energy. In this report, we develop two types of models for wind power systems: the first is common, based on the wind power aerodynamic equation, and the power coefficient can be regressed using nonlinear functions; the second is much more complicated, wherein the wind turbine system is modeled using the Fatigue, Aerodynamics, Structures, and Turbulence Modeling (FAST) tool with several degrees of freedoms. A nine-bus test power system is built in Simulink and the Real-Time Digital Simulator, respectively, which are used to evaluate the frequency support performance of the WPPs. We implement two distinct types of inertial control methods in the modeled wind turbines: frequency-based inertial control (FBIC) and stepwise inertial control (SIC). We compare the performances of the two methods in terms of their frequency nadirs, rates of change of frequency, and recovery times. We conclude the results under various wind speeds and penetration cases, which provide insight into designing the inertial response of WTGs. Further, we discuss the impact of the parameters on the performance of the inertial control methods. We evaluate both the scaling factors for the FBIC method and the slope values for the TLIC methods. The simulation work shows the characteristics of different inertial responses compared to conventional synchronous generators. Based on the simulation results, we modify, improve, and test the inertial control methods under a more realistic wind turbine model based on FAST. We then validate the inertial responses under highly turbulent wind conditions generated by TurbSim, and we examine their influences on the turbine mechanical components. The extensive simulation proves the effectiveness of the proposed inertial control methods as well as the nine-bus test power system. We then reconsider the parameters. We rebuild the same test power system using Real time Simulator Computer Aided Design (RSCAD), and we implement the inertial control methods in the real Controls Advanced Research Turbine (CART3), which is prepared for the hardware-in-the-loop field-test simulation. After the setups for the hardware and software hybrid simulation platform are complete, the inertial response is further tested on a real wind turbine for the first time, in which CART3 release the controlled inertial response against the emulated frequency excursion, provided by the real-time simulated power system test bed in RTDS.

17 WIND ENERGY↗

Interoffice Memorandum RE-04-21 "Advanced Test Reactor Power History Through Cycle 169A-1"

Table 1 lists the Advanced Test Reactor (ATR) N-16 constrained power history data since the Beryllium VI Core Internals Changeout (CIC) Cycle 134A-1 through Cycle 169A-1. The powers tabulated for Cycles 159A-1, 163A-1, and 167A-1 are higher than powers observed during operation, because powers are computed from cycle exposure, which for these cycles includes operation during the low-power “soak” portion of each cycle; whereas cycle length in Effective Full Power Days (EFPD) includes only the high-power “casualty” portion occurring after NF is established. Table 2 lists the accumulated N-16 lobe and total core exposure, as obtained from the ATR Data Acquisition System (RDAS) for Cycles 134A-1 through 169A-1. Table 3 lists the startup and shutdown dates and times, as obtained from logbooks or RDAS, depending on availability. The ATR power history prior to Cycle 134A 1 is presented in references (a) through (d).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of 2017 Through 2018 Testing of Powered Air-Purifying Respirator (PAPR) Cartridge Performance on Multiple Hanford Tank Headspaces and Exhausters

Between 2017 and 2018, 10 powered air-purifying respirator (PAPR) cartridge tests were performed on headspace vapors from three Hanford tanks (BY-108, SX-101, and SX-104) and two Hanford Tank Farm exhausters (AP in 2018 and AX in 2017). All tests were conducted under static conditions absent waste-disturbing activities in the subject tanks or tank farms. Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota), were tested on each of the five tanks or exhausters. Out of 61 1 Chemicals of Potential Concern (COPCs), only ammonia and 2,5-dimethylfuran exhibited breakthroughs with outlet concentrations that were greater than 10% of their Occupational Exposure Limits (OEL). For 2,5-dimethylfuran, elevated concentrations found in blank tube samples made the elevated outlet measurements for this COPC questionable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Grid Simulator for Multi-Megawatt Power Converter Testing and Certification

Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristics is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.

17 WIND ENERGY↗

A Scalable PDC Placement Technique for Fast and Resilient Monitoring of Large Power Grids

The wide-area measurement system (WAMS) is a key enabler of real-time monitoring of power grids. The essential goals of WAMS design are fast and resilient data transfer from phasor measurement units (PMU) to phasor data concentrators (PDC). We propose a scalable two-stage PDC placement technique for minimizing the end-to-end delay while maintaining resiliency. In the prescreening stage, the plausible candidates of PDC configurations are identified based on a graph theory-based multi-median function (MMF). Here, in this article, a computationally efficient meta-heuristic algorithm is used to address scalability. In the candidate selection stage, two different algorithms, namely, Suurballe's and Dijkstra's, are employed to identify the best of those plausible PDC configurations as the final design. This technique not only minimizes the hop paths between PMUs and PDCs, but also ensures network resiliency against single PMU, PDC, or communication link failure by incorporating the roles of PMUs in power grid observability into routing policy. Simulation results on the IEEE 57-bus test power system and the 2000-bus test power system demonstrate the effectiveness and scalability of the proposed technique.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LCSL-II Cryomodule Testing at Fermilab

Cold powered testing of all LCLS-II production cryomodules at Fermilab is complete as of February 2021. A total of twenty-five tests on both 1.3 GHz and 3.9 GHz cryomodules were conducted over a nearly five year time span beginning in the summer of 2016. During the course of this campaign cutting-edge results for cavity Q₀ and gradient in continuous wave operation were achieved. A summary of all test results will be presented, with a comparison to established acceptance criteria, as well as overall test stand statistics and lessons learned.

43 PARTICLE ACCELERATORS↗