Search NASASearch

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

MAMBA: A Prototype Modern Modular Bubble Chamber for Precision Measurement of Neutrino Nucleus Cross Sections

High precision measurements of neutrino interactions are essential for the success of future neutrino oscillation experiments. Understanding the interaction rate and precise energy spectrum requires understanding of neutrino interactions and nuclear effects. Measuring interactions in a light nuclear target , such as Hydrogen or deuterium, would provide highly valuable input to reduce reduce the uncertainties associated with neutrino-nucleus cross sections, relevant for upcoming experiments like the Deep Underground Neutrino Experiment (DUNE) and Hyper-Kamiokande (Hyper-K). A bubble chamber presents an opportunity to study a light nuclear target using hydrogen in the liquid phase as a working fluid. However historical hydrogen bubble chamber designs if placed in modern neutrino beams would miss a significant fraction of the total number of available interactions. We present a bubble chamber prototype, MAMBA, which will be used to investigate strategies for inexpensively enabling continuous cycling through improved cooling at scale and expanding the active time of historic bubble chambers. MAMBA aims to demonstrate the feasibility of precision neutrino–nucleon measurements at conditions comparable to modern beams.

Martínez Casales, María [Fermilab] (ORCID:00000003

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar

Atomically Precise Nanoclusters as Co‐Catalysts for Light‐Activated Microswimmer Motility

Microswimmers are self-propelled particles that navigate fluid environments, offering significant potential for applications in environmental pollutant decomposition, biosensing, and targeted drug delivery. Their performance relies on engineered catalytic surfaces. Gold nanoclusters (AuNCs), with atomically precise structures, tunable optical properties, and high surface area-to-volume ratio, provide a new optimal catalyst for enhancing microswimmer propulsion. Unlike bulk gold or nanoparticles, AuNCs may deliver tunable photocatalytic activity and increased catalytic specificity, making them ideal co-catalysts for hybrid microswimmers. For the first time, this study combines AuNCs with TiO 2 /Cr 2 O 3 Janus microswimmers, combining the unique properties of both materials. This hybrid system capitalizes on the tuned optical properties of AuNCs and their role as co-catalysts with TiO 2 , driving enhanced photocatalytic performance under ultraviolet (UV) excitation. Using motion analysis, it is shown that the AuNC-microswimmers exhibit significantly greater propulsion and mean squared displacement (MSD) as compared to controls. These findings suggest that the integration of nanoclusters with semiconductor materials enables state of the art, light-switchable microswimmers. These AuNC-microswimmer systems may thus offer new opportunities for environmental catalysis and other applications, providing precise control over catalytic and motile behaviors at the microscale.

36 MATERIALS SCIENCE

Multi-physics melt pool modeling and process optimization for laser direct energy deposition of Nb-based refractory C103: Defect formation, geometric precision, and process mapping

Recent developments in additive manufacturing (AM) technology have reignited interest in the fabrication of the Nb-based refractory C103 alloy offering solutions to the challenges posed by traditional manufacturing methods. However, the limited numerical and experimental studies on laser direct energy deposition (DED) of C103 have hindered the understanding of the relationships between process parameters and build quality. This has made it challenging to consistently produce parts with the desired quality and microstructure suitable for critical applications. In this study, we focus on optimizing the laser DED process for C103 by employing a hybrid approach that combines experimental techniques and computational fluid dynamics (CFD). This approach facilitates the development of process maps for defect detection and geometric precision. To achieve this, multi-layer C103 samples were fabricated using laser DED under various process parameters, enabling the creation of a process map for defect detection. Additionally, a multi-physics, multiphase simulation framework was developed within a high-performance computing (HPC) environment to establish process maps for geometric precision. Using these process maps, printability windows were identified for achieving both the desired geometric accuracy and defect-free prints. It was observed that prints with a power-to-velocity (P/V) ratio close to unity resulted in defect-free outcomes. This study provides a foundation for reducing design lead time and rejected parts, ultimately optimizing the laser DED process for C103.

Defect formation and geometric precision

Assessing the Impact of Measurement Precision on Metabolite Identification Probability in Multidimensional Mass Spectrometry-Based, Reference-Free Metabolomics

Identification of compounds with minimal ambiguity remains a central challenge in mass spectrometry-based metabolomics. Conventional compound identification relies on comparing analytical signatures (e.g., mass-to-charge ratio, collision cross section, tandem mass spectra) against reference data obtained from measurements of authentic chemical standards. The breadth of annotatable compounds using this approach is necessarily limited by availability of authentic standards, analytical throughput, and resolving power of the separations that underly the measurements. The maturation of computational methods, both theory-driven and artificial intelligence/machine learning-based, for prediction of various molecular properties relevant to multidimensional mass spectrometry measurements has opened the door to a new “reference-free” paradigm of compound annotation. Through augmenting existing reference data for molecular properties with computational predictions, the universe of identifiable chemical species can be expanded significantly beyond its current limits. An unexplored aspect of this novel approach is understanding how to gauge confidence in resulting annotations, especially as the compound search space is expanded. Intuitively, the confidence of a compound annotation is related to the inherent discriminatory power of the molecular properties used for identification, as well as the precision with which the properties are measured or predicted. In this work, we characterize this relationship between measurement precision and identification probability in a systematic and quantitative fashion for a defined region of chemical space that includes organic small molecule metabolites. Importantly, this work establishes a framework for conducting metabolite identification probability analysis that enables others to quantify this relationship for their own compounds and properties of interest.

Metabolite Identification

Improving statistical precision in Monte Carlo samples with negative weights via reweighting and uncertainty quantification

High statistical precision is critical for Monte Carlo (MC) samples in high energy physics and is degraded by negatively weighted events. This paper investigates a procedure to learn the relationship between the negative and positive weight distributions of any sample, allowing the reduction of statistical uncertainty by reweighting kinematically equivalent events with the same sign. A robust uncertainty quantification method is required for the practical application of such method. Two methods for the estimation of the reweighting uncertainty are developed: one at the event and another one at the final observable level. The latter method is strongly favored. The gains in statistical precision are then quantified. The method is demonstrated on Sherpa vector boson plus jets samples when using all generated events and when restricted to the signal region of a mock analysis. It is demonstrated to significantly reduce stochastic behavior in sparse MC samples while decreasing the overall uncertainty with a sufficiently well-known reweighting function.

Monte Carlo methods

Precision measurements of Higgs hadronic decay modes at the FCC-ee

The expected precision at the FCC-ee on the product $σ$ x $\mathcal{B} \large{(}H → b\bar{b}, c\bar{c}, s\bar{s}, gg\large{)}$ of Higgs boson production cross sections times branching ratios of hadronic decays is presented. This study provides the first comprehensive determination of all major hadronic Higgs decay modes in a combined fit at future $e^+e^−$ colliders, using both Higgs-strahlung $(ZH)$ and Vector boson fusion $(v\bar{v}H)$ production processes, with a full treatment of interference effects in the $v\bar{v}jj$ final state. It assumes four identical IDEA detectors collecting $e^+e^−$ collisions at $\sqrt{s}$ = 240 and 365 GeV. The combination of all channels across both energies, with full covariance between production and decay modes, yields a production cross-section times branching-ratio precision at the percent to per-mil level for the dominant hadronic final states $(b\bar{b}, c\bar{c}, gg)$. These results provide a comprehensive input to the determination of Higgs coupling projections at the FCC-ee, and they establish for the first time sensitivity to the rare decay $H → s\bar{s}$, demonstrating that FCC-ee has the potential to provide evidence of the strange-quark Yukawa coupling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Atomically precise synthesis of oxides with hybrid molecular beam epitaxy

Advancements in synthesis science are revolutionizing the way we create atomically precise materials. Techniques like molecular beam epitaxy (MBE) have set the benchmark for addressing long-standing questions in materials science by leveraging improved control over the composition and structure of existing materials and enabling materials discovery. In this review, we discuss recent innovations in MBE that are redefining its capabilities, enabling the fabrication of ultra-pure, defect-engineered films and the stabilization of metastable phases that were previously unattainable. These advancements are unlocking new opportunities in electronic, magnetic, and quantum technologies, where the precise tuning of material properties is essential for advancing device functionality and performance.

complex oxides

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Enabling event-by-event precision in γ-ray cascades for neutron-induced reactions

Neutron-induced γ-ray spectra provide key inputs for modern active interrogation applications. A precise modeling of the nuclear reaction and subsequent emission of γ rays is challenging and often impossible due to limitations on evaluated data file formats and nuclear transport simulation codes. We present a framework that addresses these challenges by combining experimental data and reaction-model calculation outputs into an extended candidate version of the Generalized Nuclear Data Structure (GNDS) file, the successor format for the legacy Evaluated Nuclear Data File (ENDF-6). This proposed GNDS hierarchical format contains all the necessary ingredients for inline γ-ray cascade reproduction with event-by-event precision, including continuum–continuum and continuum–discrete transitions following neutron-capture and inelastic neutron scattering reactions. Cascade-event generation based on our approach demonstrates improved energy conservation on an event-by-event basis and permits the use of γ-γ coincidences in applications. This work offers, for the first time, a method to generate neutron-capture and inelastic neutron-scattering γ-ray cascades where energy conservation, correlations, and experimental primaries are fully accounted for.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Precise measurement of nuclear interaction cross sections towards neutron-skin determination with R 3 B

The R 3 B (Reactions with Relativistic Radioactive Beams) experiment as a major instrument of the NUSTAR collaboration for the research facility FAIR in Darmstadt is designed for kinematically complete studies of reactions with high-energy radioactive beams. Part of the broad physics program of R 3 B is to constrain the asymmetry term in the nuclear equation-of-state and hence improve the description of highly asymmetric nuclear matter (e.g., in neutron stars). For a precise determination of the neutron-skin thickness – an observable which is directly correlated with the symmetry energy in theoretical calculations – by measuring absolute fragmentation cross sections, it is essential to quantify the uncertainty and challenge the reaction model under stable conditions. During the successful FAIR Phase-0 campaign of R 3 B, we precisely measured the energy dependence of total interaction cross sections in 12 C + 12 C collisions, for a direct comparison with calculations based on the eikonal reaction theory.

Ponnath, L. (ORCID:0000000286742624)

Precise mass measurements of A = 133 isobars with the Canadian Penning Trap: Resolving the Q β − anomaly at 133Te

We report precision mass measurements of 133 Sb 133g,m Te, and 133g,m I, produced at CARIBU at Argonne National Laboratory's ATLAS facility and measured using the Canadian Penning Trap mass spectrometer. These masses clarify an anomaly in the 133 Te β-decay. The masses reported in the 2020 Atomic Mass Evaluation (M. Wang et al., 2021) produce Q B - ( 133 Te)=2920(6) keV; however, the highest-lying 133 I level populated in this decay is observed at E i = 2935.83(15) keV, resulting in an anomalous Q$^i_B-$ = -16(6)keV. Our new measurements give Q B - ( 133 Te)=2934.8(11) keV, a factor of five more precise, yielding Q$^i_B$ = -1.0(12) keV, a 3σ shift from the previous results. This resolves this anomaly, but indicates further anomalies in our understanding of the structure of this isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk

Precise Linker Length and Dynamic Bond Exchange Control Penetrant Diffusion in Dense Vitrimers

Polymer networks with dynamic covalent bonds have been investigated for their self-healing ability, recyclability, and potential as more sustainable materials. Recent results have indicated that in some cases, bond exchange can enhance the transport of penetrants in dense networks, pointing to their potential for separations of membranes. Here, imine dynamic bonds in ethylene oxide (EO) networks with precise linker lengths were synthesized to investigate the transport of N,N′-bis(2,5-di-tert-butylphenyl)-3,4,9,10-perylenedicarboximide (BTBP), a large, anisotropic dye molecule. Networks with mesh sizes smaller than, comparable to, and greater than the size of the penetrant axes were investigated to probe the effects of bond exchange and network confinement on transport. Mesh sizes, which ranged from 0.5 to 1.62 nm, were determined from shear rheology, glass transitions by calorimetry, and probe diffusion coefficients by fluorescence recovery after photobleaching. Permanent networks with identical EO chain lengths were prepared as control samples, and up to a 3 orders of magnitude increase in diffusion coefficient is observed in the dynamic systems for short linkers containing 13 backbone atoms. The longest linkers with 71 backbone atoms show no difference between the permanent and dynamic networks. Linkers shorter than 11 backbone atoms, corresponding to a mesh size smaller than the penetrant small axis, diffusion is no longer observable on the experimental time scale, indicating a sharp cutoff attributed to the precise linkers and narrow mesh size distribution. The dynamic imine exchange time scales were compared to the diffusive hopping times of penetrants and indicate that exchange can occur during a diffusive displacement. Furthermore, these findings provide insights into the factors affecting penetrant transport in dense polymers and inspire the development of next-generation selective polymer membranes.

Diffusion

Toward Continuous, Oriented Covalent Organic Framework Membranes for Precise Molecular Separations

The goal of achieving energy-efficient, precise molecular separations has motivated interest in developing and employing porous crystalline frameworks as membrane materials. Covalent organic frameworks (COFs) are ordered crystalline matrices composed of covalently bonded organic monomers and are synthesized via reversible reticular chemistry. COFs possess high porosity, structural tunability, and chemical and thermal stability, making them ideally suited for emerging, high-value membrane separation processes, such as ion separations, organic solvent nanofiltration, and gas separations. Although a range of COF membranes have been fabricated and tested in the past decade, these membranes are primarily polycrystalline, weakly crystalline, and/or discontinuous, resulting in suboptimal performance. In this review, we identify the properties that make COFs well-suited as membrane materials, while critically outlining the shortcomings of existing disordered COF membranes. We then highlight the recent emergence of highly crystalline, continuous, oriented two-dimensional COF membranes as a promising path forward for highly selective molecular separations. These continuous, oriented COF membranes exhibit tunable one-dimensional nanochannels, allowing for ultrafast molecular transport and precise species selectivity, thereby expanding the set of separations that can be practically achieved with membrane systems. We discuss synthesis and modification techniques that result in continuous, oriented COF membranes and evaluate the performance of such membranes for a variety of molecular separations. We conclude by identifying ongoing challenges in the development of COF membranes and outlining the future of their applications in molecular separations, which will necessarily rely on advancements in the synthesis of continuous, oriented membranes.

COF modification

Functionalized Graphene via a One-Pot Reaction Enabling Exact Pore Sizes, Modifiable Pore Functionalization, and Precision Doping

Functionalizing graphene with exact pore size, specific functional groups, and precision doping poses many significant challenges. Current methods lack precision and produce random pore sizes, sites of attachment, and amounts of dopant, leading to compromised structural integrity and affecting graphene’s applications. In this work, we report a strategy for the synthesis of functionalized graphitic materials with modifiable nanometer-sized pores via a Pictet–Spengler polymerization reaction. This one-pot, four-step synthesis uses concepts based on covalent organic frameworks (COFs) synthesis to produce crystalline two-dimensional materials that were confirmed by PXRD, TEM measurements, and DFT studies. These new materials are structurally analogous to doped graphene and graphene oxide (GO) but, unlike GO, maintain their semiconductive properties when fully functionalized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Precision Labeling of Native Antibodies with Lock Coupling

The formation of stable protein complexes enables much of biotechnology, but even high-affinity complexes can dissociate, limiting potential applications in biomaterials, bioimaging, nanomedicine, and other protein-based technologies. Here, in this study, we describe lock coupling, a simple and selective one-step reaction between interfacial lysine and glutamate or aspartate side chains to form stable isopeptide bonds and be used for the precise labeling of native antibodies. We identify conditions in which short-lived activated esters formed by the aqueous carbodiimide EDC promote isopeptide bond formation specifically at preassociated amine-acid pairs. Indiscriminate cross-linking is minimized by formation of protein complexes before addition of catalyst, use of acidic pH to suppress exposed Lys reactivity, and limiting the aqueous stability of activated esters. For native antibody (Ab) labeling, we show that the small IgG-binding protein GB1 can be covalently attached to the Ab Fc domain and that introduction of Cys into GB1 loops allows for facile conjugation of fluorophores, micelles, or inorganic nanocrystals for imaging in live cells and animals. By varying Cys substituents and protein stoichiometry, a defined number of probes can be uniformly attached without the need for extensive purification. In live-cell confocal microscopy, labeled GB1 serves as a stable replacement for secondary Abs, enabling simple multicolor immunostaining and imaging. Lock coupling requires just a single reagent in aqueous buffer and leverages both the innate ability of proteins to form high-affinity complexes and the widespread presence of Lys-Glu/Asp pairs at their interfaces, with the potential for precision synthesis of protein-based probes for imaging, biomaterials, biophysics, and medicine.

antibody