Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision Time Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Location-oblivious data transfer with flying entangled qudits

We present a simple and practical quantum protocol involving two mistrustful agencies in Minkowski space, which allows Alice to transfer data to Bob at a space-time location that neither can predict in advance. The location depends on both Alice's and Bob's actions. The protocol guarantees unconditionally to Alice that Bob learns the data at a randomly determined location; it guarantees to Bob that Alice will not learn the transfer location even after the protocol is complete. The task implemented, transferring data at a space-time location that remains hidden from the transferrer, has no precise analog in nonrelativistic quantum cryptography. It illustrates further the scope for novel cryptographic applications of relativistic quantum theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mars Communication Protocols

Over the next decade, international plans and commitments are underway to develop an infrastructure at Mars to support future exploration of the red planet. The purpose of this infrastructure is to provide reliable global communication and navigation coverage for on-approach, landed, roving, and in-flight assets at Mars. The claim is that this infrastructure will: 1) eliminate the need of these assets to carry Direct to Earth (DTE) communications equipment, 2) significantly increase data return and connectivity, 3) enable small mission exploration of Mars without DTE equipment, 4) provide precision navigation i.e., 10 to 100m position resolution, 5) supply timing reference accurate to 10ms. This paper in particular focuses on two CCSDS recommendations for that infrastructure: CCSDS Proximity-1 Space Link Protocol and CCSDS File Delivery Protocol (CFDP). A key aspect of Mars exploration will be the ability of future missions to interoperate. These protocols establish a framework for interoperability by providing standard communication, navigation, and timing services. In addition, these services include strategies to recover gracefully from communication interruptions and interference while ensuring backward compatibility with previous missions from previous phases of exploration.

Kazz, G. J.↗

Ground Based, Millimeter Wave Measurement of Ozone in the Middle Atmosphere

There is a need for highly reliable measurements of stratospheric ozone. Policy makers worldwide concerned with public health rely oil a clear consensus from the scientific community as a basis for ozone-related environmental policy that has a significant impact oil national economies. Tile latest Such consensus was presented in WMO, and used in a 1999 meeting of the parties considering amendments to the Montreal Protocol oil Substances that Deplete the Ozone Layer. Tile scientific community, in turn, needs highly precise and accurate measurements of ozone levels, and small time derivatives of these levels, both in continued - development of its understanding of the physical and chemical processes involved and as clear evidence that these processes are occurring as stated. Over most of the world, changes in ozone levels are small. For example, over the heavily populated northern midlatitudes, the linearized rate of ozone decline is between 0.2% per year and 0.7% per year, depending on altitude. These values are small enough to make measurement requirements technically challenging. Data quality may suffer from imperfections in individual instruments. In one instance, early results from a satellite-borne ozone sensor were later found to be invalid because of calibration drift. Even in the absence of drift, tile absolute calibration of a new sensor may differ slightly from that of its predecessor in service. Most ozone remote sensing instruments operate at ultraviolet or infrared wavelengths where scattering from dust and aerosols must be taken into account; results from these systems may be or are affected following a major volcanic eruption, such as tile one at Mt. Pinatubo in 1991. Given these difficulties, a consensus of measurements from several independent systems is required to insure a reliable understanding of stratospheric ozone levels. Because of the above-described need for highly precise and accurate ozone measurements using several independent techniques, there was interest in developing several techniques which were known but not highly developed in the 1980's into systems capable of being used in ail operational manner to make measurements with the level of quality needed to-detect small trends in ozone levels. A ground-based microwave instrument capable of remotely sensing stratospheric ozone had been designed by tile Principal Investigator of the present project. This instrument was built at tile Millitech Corporation in South Deerfield, Massachusetts before tile present work began. (Funding for design and construction of the instrument came from sources other than the present grant.) Tile instrument measured the spectrum of one of the many emission lines produced by purely rotational transitions of ozone, one at a frequency of 110.8 GHz. The altitude distribution of ozone can. in principle, be retrieved from the details of the pressure-broadened spectrum of the ozone transition. However, the level of contamination of the spectral measurement by instrumentally induced artifacts must be very low in order to retrieve a ozone profile of useful quality from it. The Millitech instrument demonstrated spectral purity at ail adequate level, and there were promising ideas for instrumental improvements and for further development of the technique. The initial objectives of the present project, then, were to develop techniques for calibrating the Millitech instrument, to minimize artifacts in tile spectra it produces, to optimally retrieve ozone profiles from tile spectra, to test tile quality of the microwave profiles by comparing them with profiles obtained using several other, independent techniques over both short and periods of time, and to perform research using the ozone data gathered with the instrument.

Parrish, Alan↗

Optimality and Noise Resilience of Critical Quantum Sensing

We compare critical quantum sensing to passive quantum strategies to perform frequency estimation, in the case of single-mode quadratic Hamiltonians. We show that, while in the unitary case both strategies achieve precision scaling quadratic with the number of photons, in the presence of dissipation this is true only for critical strategies. We also establish that working at the exceptional point or beyond threshold provides suboptimal performance. This critical enhancement is due to the emergence of a transient regime in the open critical dynamics, and is invariant to temperature changes. When considering both time and system size as resources, for both strategies the precision scales linearly with the product of the total time and the number of photons, in accordance with fundamental bounds. However, we show that critical protocols outperform optimal passive strategies if preparation and measurement times are not negligible. Our results are applicable to a broad variety of critical sensors whose phenomenology can be reduced to that of a single-mode quadratic Hamiltonian, including systems described by finite-component and fully connected models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated Construction of Artificial Lattice Structures with Designer Electronic States

Manipulating matter with a scanning tunneling microscope (STM) enables the creation of atomically defined artificial structures that host designer quantum states. However, the time-consuming nature of the manipulation process, coupled with the sensitivity of the STM tip, constrains the exploration of diverse configurations and limits the size of the designed features. In this study, we present a reinforcement learning (RL)-based framework for creating artificial structures by spatially manipulating carbon monoxide (CO) molecules on a copper substrate by using the STM tip. The automated workflow combines molecule detection and manipulation, employing deep-learning-based object detection to locate CO molecules and linear assignment algorithms to allocate these molecules to designated target sites. We initially perform molecule maneuvering based on randomized parameter sampling for sample bias, tunneling current set point, and manipulation speed. This data set is then structured into an action trajectory used to train an RL agent. The model is subsequently deployed on the STM for real-time fine-tuning of the manipulation parameters during structure construction. Our approach incorporates path-planning protocols coupled with active drift compensation to enable atomically precise fabrication of structures with significantly reduced human input while realizing larger-scale artificial lattices with the desired electronic properties. Furthermore, using our approach, we demonstrate the automated construction of an extended artificial graphene lattice and confirm the existence of a characteristic Dirac point in its electronic structure. Further challenges regarding the RL-based structural assembly scalability are discussed.

Algorithms↗

CAST Technical Bulletin #002: Time Synchronization for Next Generation Power Delivery

This technical bulletin gives a description of the updated effort on Oak Ridge National Laboratory (ORNL) Center for Alternative Synchronization and Timing (CAST) project’s work investigating a terrestrial-based high precision timing infrastructure intended for time synchronization of the next generation power delivery infrastructures. We will provide a high-level description of the CAST application context, key protocols, critical architectural issues, and how GPS/timing data traverse through the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CRADA Final Report: Materials Development For Pulp and Paper Mills, Task 9 Proof of Commercial Concept: Commodity Carbon Fibers From Weyerhaeuser Lignin Based Fibers

Tasks were assigned to Oak Ridge National Laboratory (ORNL) researchers for the development of lignin-based carbon fiber from a specific precursor that was produced by the Participant (Weyerhaeuser Corporation). These tasks included characterization of precursor polymers and fibers; and the development of conversion parameters for the fibers. ORNL researchers provided recommendations for in-house characterization of the precursor at the participant's laboratory. During the early stage of the precursor fiber production trials of various spools of fibers with varied compositions were produced. Some of those samples were sent to ORNL (by the Participant) for the development of conversion protocol. The trial tow samples were oxidized at ORNL's precursor evaluation system (PES), a bench-scale facility consisting of an oven, filament winder, tension controller, and a let off creel. The PES is a modular tool useful for the development of precursor conversion protocol. It can handle a single filament to a large single tow (50k filaments). It can also offer precise tensioning for few-filament tows. In the PES, after oxidation, fibers are typically carbonized first at low temperature, {le} 600 C, and subsequently at a higher temperature, {le} 1200 C with controlled residence time. ORNL has recently installed a new carbonization furnace with 1700 C limit and a furnace with 2500 C capacity is under installation. A protocol for the oxidation and carbonization of the trial precursor fibers was developed. Oxidized fiber with a density of 1.46 g/cc (oxidation time: 90 min) shows qualitative flame retardancy via simple flame test (fibers do not catch fire or shrink when exposed to flame). Oxidized and carbonized filaments of the Weyerhaeuser precursor fibers show moderate mechanical properties and 47-51 % carbon yield (based on oxidized fiber mass) after carbonization between 1000-1400 C. The properties of fibers from nonoptimized composition and processing parameters indicate the potential of low-cost, low-end carbon fibers based on renewable resource materials. Further work is necessary to produce high quality precursor and the corresponding carbonized filaments of superior properties.

Paulauskas, Felix L↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Onboard early detection and mitigation of lithium plating in fast-charging batteries

Fast-charging is considered as one of the most desired features needed for lithium-ion batteries to accelerate the mainstream adoption of electric vehicles. However, current battery charging protocols mainly consist of conservative rate steps to avoid potential hazardous lithium plating and its associated parasitic reactions. A highly sensitive onboard detection method could enable battery fast-charging without reaching the lithium plating regime. Here, we demonstrate a novel differential pressure sensing method to precisely detect the lithium plating event. By measuring the real-time change of cell pressure per unit of charge (dP/dQ) and comparing it with the threshold defined by the maximum of dP/dQ during lithium-ion intercalation into the negative electrode, the onset of lithium plating before its extensive growth can be detected with high precision. In addition, we show that by integrating this differential pressure sensing into the battery management system (BMS), a dynamic self-regulated charging protocol can be realized to effectively extinguish the lithium plating triggered by low temperature (0 °C) while the conventional static charging protocol leads to catastrophic lithium plating at the same condition. We propose that differential pressure sensing could serve as an early nondestructive diagnosis method to guide the development of fast-charging battery technologies.

25 ENERGY STORAGE↗

Considerable contribution of the Montreal Protocol to declining greenhouse gas emissions from the United States

Ozone depleting substances (ODSs) controlled by the Montreal Protocol are potent greenhouse gases (GHGs), as are their substitutes, the hydrofluorocarbons (HFCs). Here we provide for the first time a comprehensive estimate of U.S. emissions of ODSs and HFCs based on precise measurements in discrete air samples from across North America and in the remote atmosphere. Derived emissions show spatial and seasonal variations qualitatively consistent with known uses and largely confirm U.S. Environmental Protection Agency (EPA) national emissions inventories for most gases. The measurement-based results further indicate a substantial decline of ODS emissions from 2008 to 2014, equivalent to ~50% of the CO 2 -equivalent decline in combined emissions of CO 2 and all other long-lived GHGs inventoried by the EPA for the same period. Total estimated CO 2 -equivalent emissions of HFCs were comparable to the sum of ODS emissions in 2014, but can be expected to decline in the future in response to recent policy measures.

54 ENVIRONMENTAL SCIENCES↗

Multiplexed Knockouts in the Model Diatom Phaeodactylum by Episomal Delivery of a Selectable Cas9

Marine diatoms are eukaryotic microalgae that play significant ecological and biogeochemical roles in oceans. They also have significant potential as organismal platforms for exploitation to address biotechnological and industrial goals. In order to address both modes of research, sophisticated molecular and genetic tools are required. We presented here new and improved methodologies for introducing CRISPRCas9 to the model diatom Phaeodactylum tricornutum cells and a streamlined protocol for genotyping mutant cell lines with previously unknown phenotypes. First, bacterialconjugation was optimized for the delivery of Cas9 by transcriptionally fusing Cas9 to a selectable marker by the 2A peptide. An episome cloning strategy using both negative and positive selection was developed to streamline CRISPR-episome assembly. Next, cell line picking and genotyping strategies, that utilize manual sequencing curation, TIDE sequencing analysis, and a T7 endonuclease assay, were developed to shorten the time required to generate mutants. Following this new experimental pipeline, both singlegene and two-gene knockout cell lines were generated at mutagenesis efficiencies of 48% and 25%, respectively. Lastly, a protocol for precise gene insertions via CRISPRCas9 targeting was developed using particle-bombardment transformation methods. Overall, the novel Cas9 episome design and improved genotyping methods presented here allow for quick and easy genotyping and isolation of Phaeodactylum mutant cell lines (less than 3 weeks) without relying on a known phenotype to screen for mutants.

59 BASIC BIOLOGICAL SCIENCES↗

Batch crystallization of rhodopsin for structural dynamics using an X-ray free-electron laser

A new batch preparation method is presented for high-density micrometre-sized crystals of the G protein-coupled receptor rhodopsin for use in time-resolved serial femtosecond crystallography at an X-ray free-electron laser using a liquid jet. Rhodopsin is a membrane protein from the G protein-coupled receptor family. Together with its ligand retinal, it forms the visual pigment responsible for night vision. In order to perform ultrafast dynamics studies, a time-resolved serial femtosecond crystallography method is required owing to the nonreversible activation of rhodopsin. In such an approach, microcrystals in suspension are delivered into the X-ray pulses of an X-ray free-electron laser (XFEL) after a precise photoactivation delay. Here, a millilitre batch production of high-density microcrystals was developed by four methodical conversion steps starting from known vapour-diffusion crystallization protocols: (i) screening the low-salt crystallization conditions preferred for serial crystallography by vapour diffusion, (ii) optimization of batch crystallization, (iii) testing the crystal size and quality using second-harmonic generation (SHG) imaging and X-ray powder diffraction and (iv) production of millilitres of rhodopsin crystal suspension in batches for serial crystallography tests; these crystals diffracted at an XFEL at the Linac Coherent Light Source using a liquid-jet setup.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Are Lateral Electronic Portal Images Adequate for Accurate On-Line Daily Targeting of the Prostate? Results of a Prospective Study

The purpose of this report was to evaluate the magnitude of the error that would be introduced if only a lateral (LAT) portal image, as opposed to a pair of orthogonal images, was used to verify and correct daily setup errors and organ motion in external beam radiation therapy (EBRT) of prostate cancer. The 3-dimensional (3D) coordinates of gold markers from 12 consecutive prostate patients were reconstructed using a pair of orthogonal images. The data were re-analyzed using only the LAT images. Couch moves from the 2-dimensional (2D)-only data were compared with the complete 3D data set. The 2D-only data provided couch moves that differed on average from the 3D data by 2.3 {+-} 3.0, 0.0 {+-} 0.0, and 0.8 {+-} 1.0 mm in the Lat, AP, and SI directions, respectively. Along AP and SI axes, the LAT image provided positional information similar to the orthogonal pair. The error along the LAT axis may be acceptable provided lateral margins are large enough. A LAT-only setup protocol reduces patient treatment times and increases patient throughput. In most circumstances, with exceptions such as morbidly obese patients, acquisition of only a LAT image for daily targeting of the prostate will provide adequate positional precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving noisy free-energy measurements by adding more noise

Estimating free-energy differences using nonequilibrium work relations, such as the Jarzynski equality, is hindered by poor convergence when work fluctuations are large. For systems governed by overdamped Langevin dynamics, we propose the counterintuitive approach of adding noise in order to increase the precision of such calculations. Here, by introducing additional stochastic fluctuations to the system and rescaling its potential energy accordingly, we leave the thermodynamics of the system unchanged while increasing its relaxation rate. For a given time-dependent protocol this modification reduces the dissipated reduced work, leading to more accurate free-energy estimates. The method is designed to be used in experiment, and we illustrate its operation using computer simulations applied to two model systems. However, the regime of applicability of this strategy is likely limited, because it requires control of the system's potential energy in a way that is feasible in only a few experimental settings.

Whitelam, Stephen [Lawrence Berkeley National Labo↗

Time-Resolved Hanbury Brown–Twiss Interferometry of On-Chip Biphoton Frequency Combs Using Vernier Phase Modulation

Biphoton frequency combs (BFCs) are promising quantum sources for large-scale and high-dimensional quantum information and networking systems. In this context, the spectral purity of individual frequency bins will be critical for realizing quantum networking protocols like teleportation and entanglement swapping. Measurement of the temporal autocorrelation function of the unheralded signal or idler photons comprising the BFC is a key tool for characterizing their spectral purity and in turn verifying the utility of the biphoton state for networking protocols. Yet the experimentally obtainable precision for measuring BFC correlation functions is often severely limited by detector jitter. The fine temporal features in the correlation function—not only of practical value in quantum information, but also of fundamental interest in the study of quantum optics—are lost as a result. We propose a scheme to circumvent this challenge through electro-optic phase modulation, experimentally demonstrating time-resolved Hanbury Brown–Twiss characterization of BFCs generated from an integrated 40.5-GHz Si 3 N 4 microring, up to a 3×3-dimensional two-qutrit Hilbert space. Through slight detuning of the electro-optic drive frequency from the comb’s free spectral range, our approach leverages Vernier principles to magnify temporal features, which would otherwise be averaged out by detector jitter. We demonstrate our approach under both continuous-wave and pulsed-pumping regimes, finding excellent agreement with theory. In conclusion, our method reveals not only the collective statistics of the contributing frequency bins but also their temporal shapes—features lost in standard fully integrated autocorrelation measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematic and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

Perspectives for laboratory implementation of the Duan-Lukin-Cirac-Zoller protocol for quantum repeaters

We analyze the efficiency and scalability of the Duan-Lukin-Cirac-Zoller (DLCZ) protocol for quantum repeaters focusing on the behavior of the experimentally accessible measures of entanglement for the system, taking into account crucial imperfections of the stored entangled states. We calculate then the degradation of the final state of the quantum-repeater linear chain for increasing sizes of the chain, and characterize it by a lower bound on its concurrence and the ability to violate the Clausner-Horne-Shimony-Holt inequality. The states are calculated up to an arbitrary number of stored excitations, as this number is not fundamentally bound for experiments involving large atomic ensembles. The measurement by avalanche photodetectors is modeled by ''ON/OFF'' positive operator-valued measure operators. As a result, we are able to consistently test the approximation of the real fields by fields with a finite number of excitations, determining the minimum number of excitations required to achieve a desired precision in the prediction of the various measured quantities. This analysis finally determines the minimum purity of the initial state that is required to succeed in the protocol as the size of the chain increases. We also provide a more accurate estimate for the average time required to succeed in each step of the protocol. The minimum purity analysis and the new time estimates are then combined to trace the perspectives for implementation of the DLCZ protocol in present-day laboratory setups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Fricke-gel layers for absolute dose measurements in radiotherapy

Fricke-gel layer dosimeters (FGLDs) have shown promising features for attaining absolute measurements of the spatial distribution of the absorbed dose in radiotherapy. Good precision of results (within 3%) is achieved by means of calibration of each single dosimeter before measurement. The calibration is performed irradiating the dosimeter at a uniform and precisely known dose, in order to get a calibration matrix that must be used, with pixel-to-pixel manipulation, to obtain the dose image. A study of the trend in time of dosimeter response after one or more exposures was carried out and calibration protocols were suitably established and verified. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗