Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision Time Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multiplexed Knockouts in the Model Diatom Phaeodactylum by Episomal Delivery of a Selectable Cas9

Marine diatoms are eukaryotic microalgae that play significant ecological and biogeochemical roles in oceans. They also have significant potential as organismal platforms for exploitation to address biotechnological and industrial goals. In order to address both modes of research, sophisticated molecular and genetic tools are required. We presented here new and improved methodologies for introducing CRISPRCas9 to the model diatom Phaeodactylum tricornutum cells and a streamlined protocol for genotyping mutant cell lines with previously unknown phenotypes. First, bacterialconjugation was optimized for the delivery of Cas9 by transcriptionally fusing Cas9 to a selectable marker by the 2A peptide. An episome cloning strategy using both negative and positive selection was developed to streamline CRISPR-episome assembly. Next, cell line picking and genotyping strategies, that utilize manual sequencing curation, TIDE sequencing analysis, and a T7 endonuclease assay, were developed to shorten the time required to generate mutants. Following this new experimental pipeline, both singlegene and two-gene knockout cell lines were generated at mutagenesis efficiencies of 48% and 25%, respectively. Lastly, a protocol for precise gene insertions via CRISPRCas9 targeting was developed using particle-bombardment transformation methods. Overall, the novel Cas9 episome design and improved genotyping methods presented here allow for quick and easy genotyping and isolation of Phaeodactylum mutant cell lines (less than 3 weeks) without relying on a known phenotype to screen for mutants.

59 BASIC BIOLOGICAL SCIENCES↗

Batch crystallization of rhodopsin for structural dynamics using an X-ray free-electron laser

A new batch preparation method is presented for high-density micrometre-sized crystals of the G protein-coupled receptor rhodopsin for use in time-resolved serial femtosecond crystallography at an X-ray free-electron laser using a liquid jet. Rhodopsin is a membrane protein from the G protein-coupled receptor family. Together with its ligand retinal, it forms the visual pigment responsible for night vision. In order to perform ultrafast dynamics studies, a time-resolved serial femtosecond crystallography method is required owing to the nonreversible activation of rhodopsin. In such an approach, microcrystals in suspension are delivered into the X-ray pulses of an X-ray free-electron laser (XFEL) after a precise photoactivation delay. Here, a millilitre batch production of high-density microcrystals was developed by four methodical conversion steps starting from known vapour-diffusion crystallization protocols: (i) screening the low-salt crystallization conditions preferred for serial crystallography by vapour diffusion, (ii) optimization of batch crystallization, (iii) testing the crystal size and quality using second-harmonic generation (SHG) imaging and X-ray powder diffraction and (iv) production of millilitres of rhodopsin crystal suspension in batches for serial crystallography tests; these crystals diffracted at an XFEL at the Linac Coherent Light Source using a liquid-jet setup.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Are Lateral Electronic Portal Images Adequate for Accurate On-Line Daily Targeting of the Prostate? Results of a Prospective Study

The purpose of this report was to evaluate the magnitude of the error that would be introduced if only a lateral (LAT) portal image, as opposed to a pair of orthogonal images, was used to verify and correct daily setup errors and organ motion in external beam radiation therapy (EBRT) of prostate cancer. The 3-dimensional (3D) coordinates of gold markers from 12 consecutive prostate patients were reconstructed using a pair of orthogonal images. The data were re-analyzed using only the LAT images. Couch moves from the 2-dimensional (2D)-only data were compared with the complete 3D data set. The 2D-only data provided couch moves that differed on average from the 3D data by 2.3 {+-} 3.0, 0.0 {+-} 0.0, and 0.8 {+-} 1.0 mm in the Lat, AP, and SI directions, respectively. Along AP and SI axes, the LAT image provided positional information similar to the orthogonal pair. The error along the LAT axis may be acceptable provided lateral margins are large enough. A LAT-only setup protocol reduces patient treatment times and increases patient throughput. In most circumstances, with exceptions such as morbidly obese patients, acquisition of only a LAT image for daily targeting of the prostate will provide adequate positional precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving noisy free-energy measurements by adding more noise

Estimating free-energy differences using nonequilibrium work relations, such as the Jarzynski equality, is hindered by poor convergence when work fluctuations are large. For systems governed by overdamped Langevin dynamics, we propose the counterintuitive approach of adding noise in order to increase the precision of such calculations. Here, by introducing additional stochastic fluctuations to the system and rescaling its potential energy accordingly, we leave the thermodynamics of the system unchanged while increasing its relaxation rate. For a given time-dependent protocol this modification reduces the dissipated reduced work, leading to more accurate free-energy estimates. The method is designed to be used in experiment, and we illustrate its operation using computer simulations applied to two model systems. However, the regime of applicability of this strategy is likely limited, because it requires control of the system's potential energy in a way that is feasible in only a few experimental settings.

Whitelam, Stephen [Lawrence Berkeley National Labo↗

Time-Resolved Hanbury Brown–Twiss Interferometry of On-Chip Biphoton Frequency Combs Using Vernier Phase Modulation

Biphoton frequency combs (BFCs) are promising quantum sources for large-scale and high-dimensional quantum information and networking systems. In this context, the spectral purity of individual frequency bins will be critical for realizing quantum networking protocols like teleportation and entanglement swapping. Measurement of the temporal autocorrelation function of the unheralded signal or idler photons comprising the BFC is a key tool for characterizing their spectral purity and in turn verifying the utility of the biphoton state for networking protocols. Yet the experimentally obtainable precision for measuring BFC correlation functions is often severely limited by detector jitter. The fine temporal features in the correlation function—not only of practical value in quantum information, but also of fundamental interest in the study of quantum optics—are lost as a result. We propose a scheme to circumvent this challenge through electro-optic phase modulation, experimentally demonstrating time-resolved Hanbury Brown–Twiss characterization of BFCs generated from an integrated 40.5-GHz Si 3 N 4 microring, up to a 3×3-dimensional two-qutrit Hilbert space. Through slight detuning of the electro-optic drive frequency from the comb’s free spectral range, our approach leverages Vernier principles to magnify temporal features, which would otherwise be averaged out by detector jitter. We demonstrate our approach under both continuous-wave and pulsed-pumping regimes, finding excellent agreement with theory. In conclusion, our method reveals not only the collective statistics of the contributing frequency bins but also their temporal shapes—features lost in standard fully integrated autocorrelation measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematic and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

Perspectives for laboratory implementation of the Duan-Lukin-Cirac-Zoller protocol for quantum repeaters

We analyze the efficiency and scalability of the Duan-Lukin-Cirac-Zoller (DLCZ) protocol for quantum repeaters focusing on the behavior of the experimentally accessible measures of entanglement for the system, taking into account crucial imperfections of the stored entangled states. We calculate then the degradation of the final state of the quantum-repeater linear chain for increasing sizes of the chain, and characterize it by a lower bound on its concurrence and the ability to violate the Clausner-Horne-Shimony-Holt inequality. The states are calculated up to an arbitrary number of stored excitations, as this number is not fundamentally bound for experiments involving large atomic ensembles. The measurement by avalanche photodetectors is modeled by ''ON/OFF'' positive operator-valued measure operators. As a result, we are able to consistently test the approximation of the real fields by fields with a finite number of excitations, determining the minimum number of excitations required to achieve a desired precision in the prediction of the various measured quantities. This analysis finally determines the minimum purity of the initial state that is required to succeed in the protocol as the size of the chain increases. We also provide a more accurate estimate for the average time required to succeed in each step of the protocol. The minimum purity analysis and the new time estimates are then combined to trace the perspectives for implementation of the DLCZ protocol in present-day laboratory setups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Fricke-gel layers for absolute dose measurements in radiotherapy

Fricke-gel layer dosimeters (FGLDs) have shown promising features for attaining absolute measurements of the spatial distribution of the absorbed dose in radiotherapy. Good precision of results (within 3%) is achieved by means of calibration of each single dosimeter before measurement. The calibration is performed irradiating the dosimeter at a uniform and precisely known dose, in order to get a calibration matrix that must be used, with pixel-to-pixel manipulation, to obtain the dose image. A study of the trend in time of dosimeter response after one or more exposures was carried out and calibration protocols were suitably established and verified. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Entanglement swapping systems toward a quantum internet

We demonstrate conditional entanglement swapping, i.e. teleportation of entanglement, between time-bin qubits at the telecommunication wavelength of 1536.4 nm with high fidelity of 87%. Our system is deployable, utilizing modular, off-the-shelf, fiber-coupled, and electrically controlled components such as electro-optic modulators. It leverages the precise timing resolution of superconducting nanowire detectors, which are controlled and read out via a custom developed graphical user interface. The swapping process is described, interpreted, and guided using characteristic function-based analytical modeling that accounts for realistic imperfections. Our system supports quantum networking protocols, including source-independent quantum key distribution, with an estimated secret key rate of approximately 0.5 bits per sifted bit.

Davis, Samantha I. [Caltech] (ORCID:00000001999481↗

Critical Contribution of Imbalanced Charge Loss to Performance Deterioration of Si-Based Lithium-Ion Cells during Calendar Aging

Increasing the energy density of lithium-ion batteries, and thereby reducing costs, is a major target for industry and academic research. One of the best opportunities is to replace the traditional graphite anode with a high-capacity anode material, such as silicon. However, Si-based lithium-ion batteries have been widely reported to suffer from a limited calendar life for automobile applications. Heretofore, there lacks a fundamental understanding of calendar aging for rationally developing mitigation strategies. Both open-circuit voltage and voltage-hold aging protocols were utilized to characterize the aging behavior of Si-based cells. Particularly, a high-precision leakage current measurement was applied to quantitatively measure the rate of parasitic reactions at the electrode/electrolyte interface. The rate of parasitic reactions at the Si anode was found 5 times and 15 times faster than those of LiNi 0.8 Mn 0.1 Co 0.1 O 2 and LiFePO 4 cathodes, respectively. Here, the imbalanced charge loss from parasitic reactions plays a critical role in exacerbating performance deterioration. In addition, a linear relationship between capacity loss and charge consumption from parasitic reactions provides fundamental support to assess calendar life through voltage-hold tests. These new findings imply that longer calendar life can be achieved by suppressing parasitic reactions at the Si anode to balance charge consumption during calendar aging.

25 ENERGY STORAGE↗

Controlled Synthesis of SnO 2 Nanocrystals with Tunable Band Gaps

Tin(IV) oxide nanocrystals (SnO 2 NCs) have significant potential in various applications, with their performance closely related to their band gap. The band gap is influenced by the size and shape of the NCs, which can be precisely controlled by adjusting reaction conditions. In this study, we present deliberately designed synthesis protocols to produce high-quality SnO 2 NCs with tunable band gaps using different methods. Key factors affecting the synthesis include control of the oxidizing agent, reaction temperature, solvent selection, and reaction time optimization. The resulting NCs were characterized by using TEM, XRD, XPS, and optical spectroscopy. Notably, SnO 2 NCs synthesized by controlling the oxidizing agent (air injection) in a hot organic solution were smaller in size and exhibited abundant oxygen vacancies. In contrast, extending the reaction time or using ethanol as a solvent in hydrothermal systems facilitated larger spherical or rod-like SnO 2 NCs with fewer oxygen vacancies. Further analysis of the band gap and valence band maximum energy revealed that the abundant vacancies in SnO 2 NCs synthesized with the air-controlled hot organic solution method resulted in a narrower band gap and an upshifted valence band. These synthetic strategies illustrate the potential for deliberately designing SnO 2 NCs with optimized electronic structures for various applications.

band gap↗

PBX 9404 detonation copper cylinder tests: a comparison of new and aged material

We present detonation copper cylinder test results on aged PBX 9404 (94 wt% HMX, 3 wt% CEF, 2.9 wt% NC, 0.1 wt% DPA) explosive. The charges were newly pressed from 37.5 year-old molding powder. We compare these results to equivalent data performed on the same lot when it was 3.5 years old. Comparison of the detonation energy inferred from detonation speed to that inferred from wall motion suggests that the HMX energy is unchanged but the NC energy has decreased to {approx}25% of its original value. The degradation of explosives and their binders is a subject of continual interest. Secondary explosives such as HMX are sufficiently stable near room temperature that they do not measurably degrade over a period of at least several decades. For formulated systems the bigger concern is binder degradation, for which the three main issues are strength, initiation safety, and (if the binder is energetic) energy content. In this paper we examine the detonation energy of new and aged PBX 9404 (94 wt% HMX, 3 wt% tris-{beta} chloroethylphosphate (CEF), 2.9 wt% nitrocellulose (NC), 0.1 wt% diphenylamine (DPA) [1, 2]), measured via the detonation copper cylinder test. In 1959, two independent PBX 9404 accidents [3] raised serious concerns about the safety of the formulation. Over about a decade's time, Los Alamos pursued a safer, energetically equivalent replacement, which ultimately became PBX 9501. In order to accurately compare the performance of the PBX 9404 and PBX 9501 formulations, W. Campbell and R. Engelke (C & E) developed a stringent cylinder test protocol that they called the Los Alamos Precision Cylinder Test [4]. The present aging study is possible because excellent PBX 9404 data from those qualification tests endures.

66↗

Rheological diagnostic tools for state transitions

Thermodynamic or kinetic state transitions of six polymeric systems were probed using rheology in isothermal and nonisothermal isochronal experiments. The polymeric systems were representative of three different types of transitions: Gelation, macrophase separation, and order-disorder transitions. A phenomenological dimensionless parameter termed the relative elasticity, R, was found to be particularly sensitive to these transitions and was finitely bound by the viscous limit and the elastic limit with values of zero and one, respectively. In addition, the (time or temperature) derivative of R and tan δ (with δ being the phase angle) proved to be more sensitive to transitions as compared to the respective pure values. When compared to other methods found in literature, these new phenomenological protocols are found to be robust while providing a convenient and precise means of detecting transitions. Hence, they may complement existing methods, whereas they are beneficial to industrial or other systems exhibiting multiple transitions due to their high sensitivity.

42 ENGINEERING↗

SU-F-303-10: Impact of Visual Biofeedback On Respiratory Reproducibility in 4DMRI

Purpose: Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4DCT. 4DMRI offers improved contrast. However, long scan times and irregular breathing patterns can be limiting. To address this, we introduced visual biofeedback (VBF) into 4DMRI. Methods: Eight healthy volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted coronal 4DMRIs were acquired on an open 1.0T MR- SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within pre-determined tolerances. 4DMRIs were acquired with and without VBF for 2–8 phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, end-inhale (EI) amplitude, and breathing variability (coefficient of variation, EI-COV). B-spline-based deformable image registration propagated contours from end-exhale (EE) to EI phases. Respiration-induced liver motion was calculated via centroid analysis and compared. Results: Incorporating VBF reduced 2-phase acquisition time (4.7±0.6 and 5.6±1.4 minutes with and without VBF, respectively) while reducing the amplitude EI-COV by 53.0±8.1%. On average, incorporating VBF reduced 8-phase 4DMRI acquisition times by 1.7±1.2 minutes and EI-COVs by 46.0±15.8%. Using VBF yielded higher duty cycles than free breathing (34.7% versus 28.3%, respectively). 4DMRI acquisition time was reduced for the cohort with VBF despite breathing rate remaining similar (10.5±4.0 with vs. 10.6±3.3 BPM without). Respiratory waveforms showed higher EI amplitude with VBF (0.84±0.05 a.u.) as compared to 0.72±0.06 a.u. without. This translated to differences in liver excursions, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.3±3.6, 4.8±2.1, and 1.6±1.0 mm, respectively, with VBF compared to 13.0±6.2, 3.8±2.4, and 1.2±1.4 mm without. Conclusion: Incorporating VBF system into 4DMRI substantially reduced acquisition time and breathing variability. While VBF reduced liver motion variability, differences in excursion were observed, suggesting that implementation will be required throughout the RT workflow. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an equipment evaluation agreement with MedSpira.

60 APPLIED LIFE SCIENCES↗

TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

60 APPLIED LIFE SCIENCES↗

TU-B-210-01: MRg HIFU - Bone and Soft Tissue Tumor Ablation

MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

60 APPLIED LIFE SCIENCES↗

TU-B-210-02: MRg HIFU - Advanced Approaches for Ablation and Hyperthermia

MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

60 APPLIED LIFE SCIENCES↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗