Search NASA⌕ Search

SEARCH · Search NASA

Results for “Printed sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High Temperature Pt/Alumina Co-Fired System for 500 C Electronic Packaging Applications

Gold thick-film metallization and 96 alumina substrate based prototype packaging system developed for 500C SiC electronics and sensors is briefly reviewed, the needs of improvement are discussed. A high temperature co-fired alumina material system based packaging system composed of 32-pin chip-level package and printed circuit board is discussed for packaging 500C SiC electronics and sensors.

High temperature↗

Packaging Technologies for High Temperature Electronics and Sensors

This paper reviews ceramic substrates and thick-film metallization based packaging technologies in development for 500 C silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chip-level packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550 C. A 96% alumina based edge connector for a PCB level subsystem interconnection has also been demonstrated recently. The 96% alumina packaging system composed of chip-level packages and PCBs has been tested with high temperature SiC devices at 500 C for over 10,000 hours. In addition to tests in a laboratory environment, a SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE-7 suite to the International Space Station via a Shuttle mission. This packaged SiC transistor was successfully tested in orbit for eighteen months. A spark-plug type sensor package designed for high temperature SiC capacitive pressure sensors was developed. This sensor package combines the high temperature interconnection system with a commercial high temperature high pressure stainless steel seal gland (electrical feed-through). Test results of a packaged high temperature capacitive pressure sensor at 500 C are also discussed. In addition to the pressure sensor package, efforts for packaging high temperature SiC diode-based gas chemical sensors are in process.

Chen, Liang-Yu↗

Packaging Technologies for High Temperature Electronics and Sensors

This paper reviews ceramic substrates and thick-film metallization based packaging technologies in development for 500degC silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chiplevel packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550degC. A 96% alumina based edge connector for a PCB level subsystem interconnection has also been demonstrated recently. The 96% alumina packaging system composed of chip-level packages and PCBs has been tested with high temperature SiC devices at 500degC for over 10,000 hours. In addition to tests in a laboratory environment, a SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE-7 suite to the International Space Station via a Shuttle mission. This packaged SiC transistor was successfully tested in orbit for eighteen months. A spark-plug type sensor package designed for high temperature SiC capacitive pressure sensors was developed. This sensor package combines the high temperature interconnection system with a commercial high temperature high pressure stainless steel seal gland (electrical feed-through). Test results of a packaged high temperature capacitive pressure sensor at 500degC are also discussed. In addition to the pressure sensor package, efforts for packaging high temperature SiC diode-based gas chemical sensors are in process.

Electronic packaging↗

Life support subsystem monitoring instrumentation

The recognition of the need for instrumentation in manned spacecraft life-support subsystems has increased significantly over the past several years. Of the required control and monitoring instrumentation, this paper will focus on the monitoring instrumentation as applied to life-support subsystems. The initial approach used independent sensors, independent sensor signal conditioning circuitry, and independent logic circuitry to provide shutdown protection only. This monitoring system was replaced with a coordinated series of printed circuit cards, each of which contains all the electronics to service one sensor and provide performance trend information, fault detection and isolation information, and shutdown protection. Finally, a review of sensor and instrumentation problems is presented, and the requirement for sensors with built-in signal conditioning and provisions for in situ calibration is discussed.

Powell, J. D.↗

Development and Testing of a Post-Installable Deepwater Monitoring System Using Fiber-Optic Sensors

This paper addresses the design and development of a fiber-optic monitoring system that can be deployed on existing deepwater risers and flowlines; and provides a summary of test article fabrication and the subsequent laboratory testing performed at the National Aeronautics and Space Administration-Johnson Space Center (NASA-JSC). A major challenge of a post-installed instrumentation system is to ensure adequate coupling between the instruments and the riser or flowline of interest. This work investigates the sensor coupling for pipelines that are suspended in a water column (from topside platform to seabed) using a fiber-optic sensor clamp and subsea bonding adhesive. The study involved the design, fabrication, and test of several prototype clamps that contained fiber-optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the casting of polyurethane clamp test articles to accommodate 4-inch and 8-inch diameter pipes. The prototype clamps were installed with a subsea adhesive in a "wet" environment and then tested in the NASA Structures Test Laboratory (STL). The tension, compression, and bending test data showed that the prototype sensor clamps achieved good structural coupling, and could provide high quality strain measurement for active monitoring.

Seaman, Calvin H.↗

Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

Simons, Rainee N.↗

Plant Habitat Telemetry / Command Interface and E-MIST

Plant Habitat (PH) is an experiment to be taken to the International Space Station (ISS) in 2016. It is critical that ground support computers have the ability to uplink commands to control PH, and that ISS computers have the ability to downlink PH telemetry data to ground support. This necessitates communication software that can send, receive, and process, PH specific commands and telemetry. The objective of the Plant Habitat Telemetry/ Command Interface is to provide this communication software, and to couple it with an intuitive Graphical User Interface (GUI). Initial investigation of the project objective led to the decision that code be written in C++ because of its compatibility with existing source code infrastructures and robustness. Further investigation led to a determination that multiple Ethernet packet structures would need to be created to effectively transmit data. Setting a standard for packet structures would allow us to distinguish these packets that would range from command type packets to sub categories of telemetry packets. In order to handle this range of packet types, the conclusion was made to take an object-oriented programming approach which complemented our decision to use the C++ programming language. In addition, extensive utilization of port programming concepts was required to implement the core functionality of the communication software. Also, a concrete understanding of a packet processing software was required in order to put aU the components of ISS-to-Ground Support Equipment (GSE) communication together and complete the objective. A second project discussed in this paper is Exposing Microbes to the Stratosphere (EMIST). This project exposes microbes into the stratosphere to observe how they are impacted by atmospheric effects. This paper focuses on the electrical and software expectations of the project, specifically drafting the printed circuit board, and programming the on-board sensors. The Eagle Computer-Aided Drafting (CAD) software was used to draft the E-MIST circuit. This required several component libraries to be created. Coding the sensors and obtaining sensor data involved using the Arduino Uno developmental board and coding language, and properly wiring peripheral sensors to the microcontroller (the central control unit of the experiment).

Walker, Uriae M.↗

Pushing the Limits of Cubesat Attitude Control: A Ground Demonstration

A cubesat attitude control system (ACS) was designed at the NASA Marshall Space Flight Center (MSFC) to provide sub-degree pointing capabilities using low cost, COTS attitude sensors, COTS miniature reaction wheels, and a developmental micro-propulsion system. The ACS sensors and actuators were integrated onto a 3D-printed plastic 3U cubesat breadboard (10 cm x 10 cm x 30 cm) with a custom designed instrument board and typical cubesat COTS hardware for the electrical, power, and data handling and processing systems. In addition to the cubesat development, a low-cost air bearing was designed and 3D printed in order to float the cubesat in the test environment. Systems integration and verification were performed at the MSFC Small Projects Rapid Integration & Test Environment laboratory. Using a combination of both the miniature reaction wheels and the micro-propulsion system, the open and closed loop control capabilities of the ACS were tested in the Flight Robotics Laboratory. The testing demonstrated the desired sub-degree pointing capability of the ACS and also revealed the challenges of creating a relevant environment for development testin

Sanders, Devon S.↗

Correlated Electromagnetic Levitation Actuator: A Reaction Sphere Based Attitude Control System

To address problems experienced by current reaction wheels and control moment gyroscopebased attitude control systems (ACS), researchers at NASA’s Marshall Space Flight Center have begun developing a reaction sphere actuator based on correlated electromagnetic levitation that will be immune to destructive bearing friction, momentum saturation, and gimbal lock. The Correlated Electromagnetic Levitation Actuator (CELA) advances the state of the art of reaction sphere ACSs by employing the concept of correlated magnetics. It is a frictionless, direct-drive reaction sphere that harnesses a unique technology with an array of applications across multiple disciplines. Correlated electromagnets function in a manner that is analogous to a matched filter; the convolution of two signals is peaked at the index representing the greatest match. For CELA, the signals are the patterns of magnetic flux density as a function of position. The magnitude of the convolution equates to an attractive or repulsive force, and these forces can be azimuthal or radial. The development of CELA is based in four distinct disciplines: Advanced Manufacturing, Prototype Development, Electromagnetic Modeling, and Controls. We are developing novel manufacturing techniques required to build arrays of permanent and electromagnet dipoles on curved surfaces. To print the permanent magnetic array, we have developed a probe with pyramidal magnets that will reside on a robotic arm to induce localized magnetic fields on a surface. The probe also includes the ability to erase dipole patterns from a permanent magnet by heating the surface to its Curie temperature. A number of test articles and prototypes have been developed using additive manufacturing methods. These prototypes have included hemispherical motors to test the drive algorithm, and a levitation test bed that demonstrates a magnetic bearing method based on attractive magnetic forces and ratiometric Hall effect sensors. We developed an array of electromagnetic dipoles on a printed circuit board (PCB) with individual H-bridges controlling each coil. This device created various flux density patterns and we measured their magnetic fields using a custom Hall effect 3-D probe and a LabVIEW virtual instrument. These data will serve as a benchmark for characterizing the accuracy of future models. Current work is focused on modeling the magnetic fields of our prototype arrays using COMSOL Finite Element Analysis and verifying the model against our test data. Accurate modeling will allow us to quickly test new patterns of electromagnets and their macro behavior. Eventually, the magnetic field models will be implemented in our controls simulations to facilitate precise control of the reaction sphere. Initial model results agree with field measurements to within 1 G (5% of measured flux density). Currently, we are testing different material properties of the electromagnets and their magnetic fields and thermal effects. These results will be used to refine the design of the electromagnetic dipoles. Our control efforts have centered on developing commutation, levitation, and field pattern shaping hardware in the form of breadboards and PCBs with software running on a local microcontroller. In addition, our partners developed MATLAB Simulink models to demonstrate a PID controller thatmitigates disturbance forces resulting from the interaction of drive and levitation magnetics. Finally, we have designed a three-axis test stand that will be used in future work to demonstrate CELA’s orientation control capability.

controls↗

Correlated Electromagnetic Levitation Actuator: A Reaction Sphere-Based Attitude Control System

To address problems experienced by current reaction wheels and control moment gyroscopebased attitude control systems (ACS), researchers at National Aeronautics and Space Administration’s (NASA’s) Marshall Space Flight Center (MSFC) have begun developing a reaction sphere actuator based on correlated electromagnetic levitation that will be immune to destructive bearing friction, momentum saturation, and gimbal lock. The Correlated Electromagnetic Levitation Actuator (CELA) advances the state of the art of reaction sphere ACSs by employing the concept of correlated magnetics. It is a frictionless, direct-drive reaction sphere that harnesses a unique technology with an array of applications across multiple disciplines. Correlated electromagnets function in a manner that is analogous to a matched filter; the convolution of two signals is peaked at the index representing the greatest match. For CELA, the signals are the patterns of magnetic flux density as a function of position. The magnitude of the convolution equates to an attractive or repulsive force, and these forces can be azimuthal or radial. The development of CELA is based in four distinct disciplines: Advanced Manufacturing, Prototype Development, Electromagnetic Modeling, and Controls. We are developing novel manufacturing techniques required to build arrays of permanent and electromagnet dipoles on curved surfaces. To print the permanent magnetic array, we have developed a probe with pyramidal magnets that will reside on a robotic arm to induce localized magnetic fields on a surface. We have also used high temperature ovens to erase dipole patterns from a permanent magnet by heating the surface to its Curie temperature. A number of test articles and prototypes have been developed using additive manufacturing methods. These prototypes have included hemispherical motors to test the drive algorithm, and a levitation test bed that demonstrates a magnetic bearing method based on attractive magnetic forces and ratiometric Hall effect sensors. We developed an array of electromagnetic dipoles on a printed circuit board (PCB) with individual H-bridges controlling each coil. This device created various flux density patterns and we measured their magnetic fields using a custom Hall effect 3-D probe and a LabVIEW virtual instrument. These data will serve as a benchmark for characterizing the accuracy of future models. Current work is focused on modeling the magnetic fields of our prototype arrays using COMSOL finite element analysis (FEA) and verifying the model against our test data. Accurate modeling will allow us to quickly test new patterns of electromagnets and their macro behavior. Eventually, the magnetic field models will be implemented in our controls simulations to facilitate precise control of the reaction sphere. Initial model results agree with field measurements to within 1 G (5% of measured flux density). Currently, we are testing different material properties of the electromagnets and their magnetic fields and thermal effects. These results will be used to refine the design of the electromagnetic dipoles. Our control efforts have centered on developing commutation, levitation, and field pattern shaping hardware in the form of breadboards and PCBs with software running on a local microcontroller. In addition, our partners developed MATLAB Simulink models to demonstrate a PID controller that mitigates disturbance forces resulting from the interaction of drive and levitation magnetics. Finally, we have designed a three-axis test stand that will be used in future work to demonstrate CELA’s orientation control capability.

reaction sphere↗

Modeling of the Near Field Coupling Between an External Loop and an Implantable Spiral Chip Antennas in Biosensor Systems

In this paper, the near field coupling between an external hand-held loop antenna and an implantable miniature (1x1 mm) printed square spiral chip antenna used in bio-MEMS sensors for contact-less powering and RF telemetry is investigated. The loop and the spiral are inductively coupled and effectively form a transformer. The numerical results include the quasi-stationary magnetic field pattern of the implanted antenna, near zone wave impedance as a function of the radial distance and the values of the lumped elements in the equivalent circuit model for the transformer.

Simons, Rainee N.↗

Carbon Nanomaterials for Biosensing Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Printed Multi-Turn Loop Antenna for RF Bio-Telemetry

In this paper, a novel printed multi-turn loop antenna for contact-less powering and RF telemetry from implantable bio- MEMS sensors at a design frequency of 300 MHz is demonstrated. In addition, computed values of input reactance, radiation resistance, skin effect resistance, and radiation efficiency for the printed multi-turn loop antenna are presented. The computed input reactance is compared with the measured values and shown to be in fair agreement. The computed radiation efficiency at the design frequency is about 24 percent.

Simons, Rainee N.↗

Design, development, and field demonstration of a remotely deployable water quality monitoring system

A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

Wallace, J. W.↗

AIAA Ascend 2021 Conference On Demand Manufacturing of Electronics Panel Abstract

1. Session Proposal o Session Title NASA’s In Space Manufacturing and the On Demand Manufacturing of Electronics o Session Topic Primary -- Space Logistics, Autonomy, and Robotics; Secondary – Transformative Research and Technologies o Session Format: Panel Discussion. o Requested Session Duration: 60 minutes o Short Session Description: The goal of NASA’s On Demand Manufacturing of Electronics project is to develop and demonstrate the feasibility of a low-gravity, on-demand manufacturing system for flexible hybrid electronic devices on the International Space Station. This panel will feature several key collaborators and team members from the commercial sector, academia, and internal to NASA, each of which are contributing an unique and vital role to the design and implementation of this new technology system. o Extended Session Description (Please describe in detail the activity proposed, including how you intend to use the requested session duration. This session description will be provided to the reviewers for consideration and will not be displayed in the online agenda.): The session will be moderated by Curtis Hill, the Project Lead for the On Demand Manufacturing of Electronics (ODME), and he will start by giving a brief introduction to the ODME project which is working to produce a demo system for the manufacturing of electronic devices on the International Space Station. Panelists consisting of collaborators and team members to the ODME project will then give a brief (~5 min) introduction highlighting their contributions to the project, followed by time for Q&A from the audience. The panel will consist of: 1. Kenneth Church, nScrypt. nScrypt is a leader in multi-material printing with a modular system that incorporates a direct write thick film print head, a polymer fused filament fabrication print head, a laser sintering attachment, a drill head attachment for milling, and a pick and place. The system can print a layer and scan for accuracy of prints. The combination of multiple print heads and scanning allows for the on-demand production of intricate electronic components. 2. Andy Kurk, TechShot, Inc. Techshot, Inc. has collaborated extensively with NASA on the in space manufacturing of both printed electronics and fused metal materials. They are currently working to develop and integrate a test system for printed electronics, and a flight demonstration on the International Space Station is anticipated in 2024. 3. Ed Hendricks, NextFlex. NextFlex has the goal of advancing the manufacture of flexible hybrid electronics in the U.S. They are working with ODME on the development of AstroSense, an additively manufactured, wireless, flexible, and wearable health sensor. 4. Dr. Pradeep Lall, Auburn University. Professor Lall is the MacFarlane Endowed Distinguished Professor in the Department of Mechanical Engineering with a Courtesy Joint Appointment in the Department of Electrical and Computer Engineering and a Courtesy Joint Appointment in the Department of Finance. He is collaborating with NASA’s ODME project to develop multilayer printable devices and to develop techniques to test the quality of a printed electronic device. 5. Dr. Wei Gao, California Institute of Technology. Professor Gao is an Assistant Professor of Medical Engineering. His group is developing fully printed, flexible, and wearable biosensors for crew health monitoring in collaboration with NASA’s ODME project. In addition, they are working on using sweat to power biofuel cells for wearable, self-powered electronic devices. 6. Beth Paquette, NASA Goddard. The ODME branch at NASA Goddard is spearheading a sounding rocket flight demo to prove the capability of a printed electronic device with multiple sensors. In addition, they focus on thin film and flexible energy storage evaluations. o Session Goal(s)/Outcome(s): Please list the learning objectives and/or tangible outcomes (technical paper or other publication). The goal of this session is to highlight the internal and collaborative efforts of NASA’s On Demand Manufacturing of Electronics project to develop a system for printing electronics that will be tested on the International Space Station in 2024. In addition, the session with facilitate discussion with the community on the state of the art of printable electronics, current challenges, and new avenues for collaboration.

Jennifer McInnis Jones↗

Development of Flexible Energy Storage Device for Wearable Electronics using All-organic Composites

As the demands and applications of wearable electronics increase, the need of power supply for wearable electronics becomes the critical issue. Both batteries and capacitors can be used as power supplier. In terms of energy storage device, capacitors have many advantages over the batteries, but have a lower energy storage density. To improve the energy density, composites, in which inorganic particles are embedded in a polymer matrix, have been identified as a promising approach to create the dielectrics with a higher energy storage density. The physics behind the composite approach is that the inorganics have a higher dielectric constant and polymers can stand with a higher electric field so that the composites can exhibit a relative dielectric constant and stand with a relative electric field. Therefore, the composites can exhibit a higher energy storage density. However, the embedment of inorganic particles into polymer severely reduces the flexibility of the polymer. To develop flexible energy storage ultracapacitors as an energy storage device for wearable electronics, an all-organic composite approach, in which a dielectric polymer is mixed with polar organic molecules, is introduced. It is experimentally found that by adding a small amount of polar organic molecules into dielectric polymers, the polymers exhibits a high dielectric constant and can stand with a higher electric field. More importantly, the flexibility of the all-organic composites is better than the polymer matrix. Therefore, the all-organic composites can be a strong and promising candidate for the development of flexible energy storage devices for the wearable electronics. In this study, three different dielectric polymers and three different polar molecules were studied. All the all-organic composite systems exhibit a significant improvement on the energy storage density. These new flexible energy storage devices are being developed to be fabricated with on-demandadditive electronics manufacturing processes, so that they can be fabricated when needed in space on the International Space Station and planned lunar habitat and other future missions. These flexible energy storage devices will provide the storage in concert with other printed power generation devices to allow crew health and structural health monitoring sensor devices and systems to be self-powered, not requiring any external power or batteries.

energy storage↗

Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies

The figure depicts a unit that contains a rotary-position or a rotary-speed sensor, plus electronic circuitry necessary for its operation, all enclosed in a single housing with a shaft for coupling to an external rotary machine. This rotation sensor unit is complete: when its shaft is mechanically connected to that of the rotary machine and it is supplied with electric power, it generates an output signal directly indicative of the rotary position or speed, without need for additional processing by other circuitry. The incorporation of all of the necessary excitatory and readout circuitry into the housing (in contradistinction to using externally located excitatory and/or readout circuitry) in a compact arrangement is the major difference between this unit and prior rotation-sensor units. The sensor assembly inside the housing includes excitatory and readout integrated circuits mounted on a circular printed-circuit board. In a typical case in which the angle or speed transducer(s) utilize electromagnetic induction, the assembly also includes another circular printed-circuit board on which the transducer windings are mounted. A sheet of high-magnetic permeability metal ("mu metal") is placed between the winding board and the electronic-circuit board to prevent spurious coupling of excitatory signals from the transducer windings to the readout circuits. The housing and most of the other mechanical hardware can be common to a variety of different sensor designs. Hence, the unit can be configured to generate any of variety of outputs by changing the interior sensor assembly. For example, the sensor assembly could contain an analog tachometer circuit that generates an output proportional (in both magnitude and sign or in magnitude only) to the speed of rotation.

Alhorn, Dean C.↗

Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗