Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Gun”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

Electron-beam-based Compton scattering x-ray source for probing high-energy-density physics

The physics basis for an electron-beam-based Compton scattering x-ray source is investigated for single-shot experiments at the major high-energy-density facilities, such as the Omega Laser Facility, National Ignition Facility, and Z pulsed power facility. A source of monoenergetic ( δ ε / ε < 5 % ) 10- to 50-keV x rays can be produced by scattering of a short-pulse optical laser by a 23- to 53-MeV electron beam and collimating the scattered photons. The number and spectrum of scattered photons are calculated as a function of electron packet charge, electron and laser pulse duration, laser intensity, and collision geometry. A source delivering greater than 10 10 photons in a 1-mm-radius spot and 100-ps time resolution is plausible with the available electron gun and laser technology. Applications of this source for x-ray diffraction, x-ray imaging, x-ray absorption fine structure, and x-ray absorption spectroscopy in high-energy-density physics experiments are described, demonstrating significant advancements compared to the present state of the art. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗

Low-Energy Cooling for Electron Ion Collider

Luminosity parameters at the highest hadron energy in the Electron Ion Collider (EIC) require a proton beam with a small vertical emittance. Such a small emittance can be obtained using the technique of electron cooling, by pre-cooling of the proton bunches at an injection energy of 23:8 GeV. After pre-cooling, the proton bunches are accelerated to the maximum energy for collisions. Once at the top energy, such proton bunches can be refilled frequently to maintain a high average luminosity, or, alternatively, cooling at the top energy could be provided with relaxed requirements of just counteracting the emittance growth due to Intra-Beam Scattering (IBS) and thus maintaining the luminosity close to its initial peak value. Presently, several schemes of cooling at the top energy of 275 GeV are being considered with the goal to maintain the initial proton beam parameters, thus relying on pre-cooling at the low energy to obtain such initial parameters of proton bunches. For the lowest proton collision energy of 41 GeV in the EIC, there is a need for an electron cooler which counteracts the beam emittance growth due to IBS. This can be achieved by the same electron cooler which is used for cooling of protons at 23.8 GeV. In this case, we assume the electron cooler rst pre-cools protons at an injection energy of 23.8 GeV and then, after acceleration, cools the 41 GeV protons, counteracting IBS and maintaining the beam emittances. In this report, we summarize a feasibility study of an electron cooler that would be needed to cool protons at 23.8 GeV to obtain a small vertical emittance, as well as to counteract beam growth due to IBS for collisions at 41 GeV. The traditional electron cooling system employed at a typical low-energy cooler is based on an electron beam generated with an electrostatic electron gun in DC operating mode, immersed in a longitudinal magnetic field. To cool protons at 23.8 and 41 GeV, electron beam energies of 13.0 and 22.3MeV, respectively, are required. Due to the technical limitations of static high-voltage acceleration, these beam energies require RF acceleration of a pulsed electron beam. Electron cooling using RF-accelerated electron bunches was recently successfully commissioned in RHIC, allowing us to consider such an approach for EIC low-energy electron cooling.

43 PARTICLE ACCELERATORS↗

Stability and Viability of Off-Axis Photoemission Geometries in 4D Ultrafast Electron Microscopy

Femtosecond (fs) laser-based 4D ultrafast electron microscopy (UEM) commonly makes use of photoelectron emission from a source material in the electron gun region of an otherwise conventional TEM. For TEMs equipped with thermionic guns, the source material is often LaB 6 , the same as used for thermionic operation. Here, such thermionic-based UEMs have proven useful for applications requiring large electron fluxes (i.e., high beam currents) often at the expense of beam coherence and brightness, which is especially important for single-shot nanosecond applications. Importantly, for fs-based UEMs, beam currents can be controlled over a broad range of parameter space through the properties of the fs laser and the photon pulses produced therefrom.

Willis, Simon A. [University of Minnesota, Minneap↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pressure Response Optimization of an Eddy Current-Driven Flyer Plate Valve for the ITER Shattered Pellet Injection System

One technique for mitigating disruptions in a tokamak is shattered pellet injection (SPI). SPI is a process in which a large solid pellet consisting of deuterium, neon, or argon is desublimated in a pipe gun barsrel and launched downstream. Pellets are shattered just before entering the plasma by an impact with an angled tube. Injection of these materials into the plasma radiates stored thermal energy, limits current decay rates, suppresses the generation of runaway electrons, and dissipates runaway electrons if necessary. A critical element of the SPI system is a fast-acting valve that releases high-pressure gas to dislodge and accelerate pellets directly, or indirectly via a mechanical punch. A prototype valve sized for the ITER SPI system has been designed and fabricated. A pulsed high-voltage power supply energizes the valve’s internal magnetic coil, which induces eddy currents in the adjacent flyer plate resulting in a repulsive force between the flyer plate and the coil. The flyer plate action lifts a valve seat, allowing high-pressure gas to flow from the valve plenum to the downstream (breech) location of the pellet or mechanical punch. All of the valve’s internal components are designed to operate in ITER-level static background magnetic fields. Here, a study was conducted to optimize the downstream pressure response for a range of valve sizes and operating pressures. In particular, the study analyzes the breech pressure response associated with varying plenum pressures as well as varying breech volumes. A computational fluid dynamics simulation was built in STAR-CCM+ and validated against data from laboratory experiments. The resulting simulation outputs, in the form of downstream responses for a variety of initial plenum pressures and breech volumes, will be used as a complement to experimental data to ensure the pressure pulse is suitable for pellet survivability. These data, combined with studies on pellet shear strength and shock response, will be applied to optimization of overall operating parameters of the ITER SPI system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing IHE Response to Multiple Shock Loading

The response of high explosives to shock loading is traditionally measured with a steady loading pressure. In many accident scenarios involving fragment impact, however, a loading duration that is shorter than the build up to detonation may occur. Fragments passing through multiple materials before reaching a high explosive charge may produce loading that is comprised of more than one shock wave. Additionally, the build up to detonation in high explosive corner turning loads the explosive a short duration pressure pulse, since rarefactions can often rapidly overtake the reactive wave. For these reasons, we have studied the response of the insensitive high explosive (IHE) materials PBX 9502 and LX-17 to complex loadings of varied intensity and duration. We refer to a single loading of limited duration as a “thin pulse”, whereas more complex scenarios were studied with an impactor that produces a double shock in the explosive. The following report presents experimental data and analyses of thin pulse shock initiation and double shock experiments designed to guide development of models of Insensitive High Explosives (IHEs) under controlled one-dimensional conditions relevant to accident scenarios and corner turning. Thin pulse shock initiation data on PBX 9502 and LX-17 were obtained under varied pulse duration, pressed density, and temperature conditions in order to probe various parameters essential for the development of a physics-based Cheetah reactive flow hotspot model. In situ pressure gauges provide insight into the degree of reaction in the explosive that are not obtainable with optical PDV measurements or distance measurements such as run to detonation. Double shock data was obtained to inform a Composition Aware Cheetah model which can be applied to any TATB-based IHEs. This model supports efforts to find a new IHE formulation and potentially incorporate new binders into IHE formulations. Simulations of each experiment are included to demonstrate the utility of these focused experiments to developing models of HE behavior. One-dimensional gas gun experiments are essential for characterizing shocked HE behavior and informing HE models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

H- ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced by spallation of liquid Hg due to bombardment of short (~1µs), intense (~35 A) pulses of protons delivered at 60 Hz from a storage ring which is fed by a high-intensity, 1 GeV H- LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50-60 mA of H- ions with a duty-factor of 6% for maintenance-free runs of ~120 days with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting these achievements: this report provides some historical highlights of this effort, describes our current ion source testing facilities, discusses the goals of the program and finally provides a snapshot of some of our ongoing R&D activities. In particular, we have recently simplified and improved the reliability of the plasma ignition gun for the external antenna ion source which is discussed in detail.

Welton, Robert F.↗

Demonstration of >6.0-kV Breakdown Voltage in Large Area Vertical GaN p-n Diodes With Step-Etched Junction Termination Extensions

Vertical gallium nitride (GaN) p-n diodes have garnered significant interest for use in power electronics where high-voltage blocking and high-power efficiency are of concern. In this article, we detail the growth and fabrication methods used to develop a large area (1 mm 2 ) vertical GaN p-n diode capable of a 6.0-kV breakdown. We also demonstrate a large area diode with a forward pulsed current of 3.5 A, an 8.3-mΩ$\cdot$cm 2 differential specific ON-resistance, and a 5.3-kV reverse breakdown. In addition, we report on a smaller area diode (0.063 mm 2 ) that is capable of 6.4-kV breakdown with a differential specific ON-resistance of 10.2 mΩ$\cdot$cm 2 , when accounting for current spreading through the drift region at a 45° angle. Finally, the demonstration of avalanche breakdown is shown for a 0.063-mm 2 diode with a room temperature breakdown of 5.6 kV. In this work, these results were achieved via epitaxial growth of a 50-μm drift region with a very low carrier concentration of <1×10 15 cm –3 and a carefully designed four-zone junction termination extension.

42 ENGINEERING↗

Impact damage of narrow silicon carbide (SiC) ceramics with and without environmental barrier coatings (EBCs) by various foreign object debris (FOD) simulants

The leading and trailing edges of turbine airfoils are highly susceptible to impact by foreign object debris (FOD) entrained in the gas stream of turbine engines. In this study, a narrow specimen geometry is implemented to study the FOD impact behavior of low curvature airfoil edges. Silicon carbide (SiC) ceramic specimens with and without an environmental barrier coating (EBC) are used as target materials. The EBC consists of an air plasma sprayed mullite topcoat (~ 166 µm) and silicon bond coat (~ 58 µm). Spherical (∅ 1.5 mm) FOD simulants of silicon nitride (Si3N4), partially stabilized zirconia (PSZ), and steel are used as impactors. Additionally, a modified gas gun is used to generate impact damage at normal incidence and velocities ranging between 300 to 400 m/s. In situ phase contrast X-ray radiographs, which render 2D representations of the internal transient damage, are captured during the impact experiments. Impactor hardness and toughness are found to primarily influence damage in the coating. Relative to wide specimens, the narrow specimens experience a greater level of cracking and this is postulated to result from reduced self-confinement. Irrespective of specimen geometry and impactor material type, limited cracking (i.e. enhanced shielding) is observed for the coated condition.

36 MATERIALS SCIENCE↗

Pulse Shape Discrimination in JSNS 2

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\overline{ν}$ μ → $\overline{ν}$ e appearance oscillations using neutrinos from muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS2 detector is located above ground, on the third floor of the building. We have achieved 94.95% ± 0.15% rejection of neutron events while keeping 92.82% ± 1.77% of signal, electron-like events using a data-driven likelihood method. This article will report the PSD technique using the full fiducial volume of the JSNS2 detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗