Search NASA⌕ Search

SEARCH · Search NASA

Results for “QUADRUPOLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Test Results of the First Two Full-Length Quadrupole Magnets for the LHC Hi Lumi Upgrade

The future high luminosity (Hi-Lumi) upgrade of the Large Hadron Collider (LHC) at CERN will include eight (plus two spares) 8.4 m-long cryostatted cold masses which will be components of the triplets for two LHC insertion regions. Each cold mass will consist of two 4.2 m long Nb 3 Sn high gradient quadrupole magnets, designated MQXFA, with aperture 150 mm and operating gradient 132.6 T/m, for a total of twenty magnets. Before assembling and testing the final cold masses at Fermilab, the twenty component quadrupoles will be tested first at the ver-tical superconducting magnet test facility of the Superconducting Magnet Division at Brookhaven National Laboratory (BNL), in superfluid He at 1.9 K and to 18.0 kA, to meet LHC operational requirements. The first two full-length prototype quadrupole magnets, MQXFAP1 and MQXFAP2, have been tested at BNL. This paper reports on the quench test and training results of these magnets, and also the retest of the first prototype, rebuilt and designated as MQXFAP1b. We note the test results of these magnets will be important for validating the MQXFA design.

43 PARTICLE ACCELERATORS↗

Test Results of the First Pre-Series Quadrupole Magnets for the LHC Hi-Lumi Upgrade

The future high luminosity (Hi-Lumi) upgrade of the Large Hadron Collider (LHC) at CERN will include eight (plus two spares) 10.2 m-long Cryo-assemblies which will be components of the triplets for two LHC insertion regions. Each cold mass in the Cryo-assemblies will consist of two 4.2 m-long Nb 3 Sn high gradient quadrupole magnets, designated MQXFA, with aperture 150 mm and operating gradient 132.2 T/m, for a total of twenty magnets. Before assembling and testing the final cold masses at Fermilab, the component quadrupoles are being tested first at the vertical superconducting magnet test facility of the Superconducting Magnet Division (SMD) at Brookhaven National Laboratory (BNL), in superfluid He at 1.9 K and up to 18.0 kA, in accordance with operational requirements of the LHC. The tests of the first two full-length prototype quadrupole magnets MQXFAP1 and MQXFAP2 at BNL have been reported previously. The first two pre-series magnets, the first two that will be used in the LHC, have also now been tested. This paper reports on the quench test and training results of these two magnets. The test results of these magnets will be important for validating the final MQXFA design for operational magnets.

43 PARTICLE ACCELERATORS↗

Effect of CLIQ on Training of HL-LHC Quadrupole Magnets

The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb 3 Sn magnets to be used in any large particle accelerator. At development stages, many Nb 3 Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based de-vices can affect Nb 3 Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. Here, the present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, M. A. [Fermilab]↗

Tunable Permanent Magnet Quadrupole Operating at Cryogenic Temperatures for Accelerators

The project objective is to develop a compact and tunable quadrupole using Electron Energy Corporation (EEC)’s PM materials for cryogenic accelerator applications. To achieve this objective, EEC and SLAC National Accelerator Laboratory (SLAC) will collaborate to develop a cost-effective quadrupole and optimize the conventional manufacturing process. Based on previous experience, EEC designed an innovative field adjustment capability using tuning magnets which is able to achieve all the requirements for SLAC’s cold copper collider (C3 ) application. These novel ideas enable us to develop a compact and tunable quadrupole magnet superior to the current designs. Our approach is to leverage EEC's over 50 years of experience in magnet manufacturing and SLAC’s beamline test capabilities.

42 ENGINEERING↗

Systematic Errors Induced by Dipole Component Change in Quadrupole Beam-Based Alignment Measurements for Circular Accelerators

Beam-based alignment (BBA) for quadrupole magnets is now a well-established process for circular accelerators to steer beam orbit through the magnetic centers such that beam orbit is not disturbed when the gradients of quadrupoles are changed. At some facilities, the centers estimated from BBA techniques are also used as a proxy for steering beam through the centers of nearby nonlinear magnets to minimize degradation of nonlinear dynamics caused by off-centered orbit. The random errors associated with BBA are well known, but very little attention has been paid to the systematic error generated by a dipole component change, or equivalently a shift in the magnetic center, when the quadrupole strength is varied. The analytical formulas for this error and its amplification factor (potentially a few orders of magnitude) with respect to the magnetic center motion have been derived and confirmed with simulations. We address the significance of this error as well as the part that cannot be estimated from the beam-based measurement alone. Finally, the BBA measurements obtained at NSLS-II and their systematic errors on the order of hundreds of microns are discussed.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, Michael A. [Fermilab] (ORCID:0009000557↗

Estimation of dipole-quadrupole dispersion energies.

The calculation of the dipole-quadrupole dispersion coefficient is discussed through a perturbation and a variation method. Accurate combination rules are obtained from both methods, one new and one already known. Further approximations permit computations in terms of accessible parameters. Values are calculated for the interactions of atomic pairs formed from hydrogen, alkali, and rare-gas atoms. A new relation giving the dipole-quadrupole coefficient in terms of the dipole-dipole coefficient and the dipole and quadrupole polarizabilities seems accurate, but needs further testing.

Alvarez-Rizzatti, M.↗

Quadrupole moment of CO, N2, and NO/+/

Evaluation of quadrupole moments obtained for CO, N2, and NO(+) with multiconfiguration self-consistent-field wave functions chosen by the optimized valence configuration (OVC) approach of Wahl and Das (1972). The quadrupole moments thus obtained are compared with both experimental and Hartree-Fock values. The Hartree-Fock results are found to be not very accurate for N2, especially if vibrational averages over vibrational levels greater than 1 or 2 are to be taken. The agreement between the OVC quadrupole moment and the experimental values is found to be best for CO.

Billingsley, F. P., II↗

Dipole and quadrupole anisotropy of the 2.7 K radiation

Results of measurements of the dipole and quadrupole anisotropy of the microwave background radiation are reported. Balloon-borne measurements of the temperature difference between two horn antennas pointed 90 deg apart and 45 deg from the zenith were carried out at frequencies of 24.8, 31.4 and 46.0 GHz to determine three dipole and four quadrupole parameters. When combined with data from two previous balloon flights, a dipole anisotropy of 3.78 + or - 0.30 mK in the direction 11.6 + or - 0.2 h RA, -12 + or - 5 deg dec is obtained. The measurements reveal a spectral index of 0.04 + or - 0.28 between 19.0 and 46.0 GHz, indicating that the dipole effect arises from an intrinsic anisotropy in the temperature of the background and/or a first-order Doppler shift due to solar motions. A statistically significant quadrupole effect is also detected which is attributed to the intrinsic anisotropy of the 2.7 K background.

Boughn, S. P.↗

Laboratory Automation of a Quadrupole Mass Spectrometer

Efforts directed toward interfacing an LSI II bus of a PDP 11/23 desktop computer with a quadrupole mass spectrometer for the purpose of providing a convenient system whereby mass spectral data, of the products of thermal decomposition, may be rapidly acquired and processed under programmed conditions are described. The versatility and operations of the quadrupole mass spectrometer are discussed as well as the procedure for configurating the LSI II bus of the PDP 11/23 desktop computer for interfacing with the quadrupole mass spectrometer system. Data from the mass filter and other units of the spectrometer are digitally transferred to the computer whereupon mass spectral data and related data are generated.

Thompson, J. M.↗

Theoretical electric quadrupole transition probabilities for Ca, Sr and Ba

The 1D-1S quadrupole transition probabilities for Ca, Sr and Ba have been computed using extended GTO and STO valence basis sets and configuration-interaction wavefunctions that include the important core-valence correlation effects. For Ba and Sr, the relativistic contraction of the core orbitals was accounted for in the GTO calculations by a relativistic effective-core potential. The computed Einstein coefficient for Ca of 39.6/s is in excellent agreement with the recent experimental value of 40 + or - 8/s. The best Einstein coefficients for Sr (44.7/s) and Ba (2.98/s) imply increasing quadrupole line strengths down the column. Relativistic effects substantially increase the quadrupole Einstein coefficient for Ba.

Bauschlicher, C. W., Jr.↗

The exact calculation of quadrupole sources for some incompressible flows

This paper is concerned with the application of the acoustic analogy of Lighthill to the acoustic and aerodynamic problems associated with moving bodies. The Ffowcs Williams-Hawkings equation, which is an interpretation of the acoustic analogy for sound generation by moving bodies, manipulates the source terms into surface and volume sources. Quite often in practice the volume sources, or quadrupoles, are neglected for various reasons. Recently, Farassat, Long and others have attempted to use the FW-H equation with the quadrupole source and neglected to solve for the surface pressure on the body. The purpose of this paper is to examine the contribution of the quadrupole source to the acoustic pressure and body surface pressure for some problems for which the exact solution is known. The inviscid, incompressible, 2-D flow, calculated using the velocity potential, is used to calculate the individual contributions of the various surface and volume source terms in the FW-H equation. The relative importance of each of the sources is then assessed.

Brentner, Kenneth S.↗

Enabling the Next Generation of Spaceborne Quadrupole Mass Spectrometers

The quadrupole mass spectrometer (QMS) has over 30 years of spaceflight heritage in making important neutral gas and low energy ion observations. Given their geometrical constraints, these instruments are currently operated at the extreme limit of their capabilities. However, a technique called higher order auxiliary excitation provides a set of novel, robust, electronics-based solutions for improving the performance of these sensors. By driving the quadrupole rods with an additional frequency nearly twice that of the normal RF operating frequency, substantially increased abundance sensitivity, maximum attainable mass resolution, and peak stability can be achieved through operation of voltage scan lines through the center of formed upper stability islands. Such improvements are modeled using numerical simulations of ion trajectories in a quadrupole field with and without applied higher order auxiliary excitation. When compared to a traditional QMS with a mass range up to 500Da, sensors can be designed with the same precision electronics to have expected mass ranges beyond 1500Da with a power increase of less than twice that of its heritage implementations.

Gershman, D. J.↗

Simulation of Thermographic Responses of Delaminations in Composites with Quadrupole Method

The application of the quadrupole method for simulating thermal responses of delaminations in carbon fiber reinforced epoxy composites materials is presented. The method solves for the flux at the interface containing the delamination. From the interface flux, the temperature at the surface is calculated. While the results presented are for single sided measurements, with ash heating, expansion of the technique to arbitrary temporal flux heating or through transmission measurements is simple. The quadrupole method is shown to have two distinct advantages relative to finite element or finite difference techniques. First, it is straight forward to incorporate arbitrary shaped delaminations into the simulation. Second, the quadrupole method enables calculation of the thermal response at only the times of interest. This, combined with a significant reduction in the number of degrees of freedom for the same simulation quality, results in a reduction of the computation time by at least an order of magnitude. Therefore, it is a more viable technique for model based inversion of thermographic data. Results for simulations of delaminations in composites are presented and compared to measurements and finite element method results.

Winfree, William P.↗

Performance of a MQXF Nb 3 Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb 3 Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of phosphorus and sulfur in uranium ore concentrates by triple quadrupole inductively coupled plasma mass spectrometry

The analysis of impurities in a uranium ore concentrate (UOC) could provide information regarding the source, production history, and potential intended use of the UOC. This study involves the analysis of UOC samples for phosphorus and sulfur. Here, concentrations were determined by triple quadrupole inductively coupled plasma – mass spectrometry and compared with results from a pyrohydrolysis method as well as previously reported results. The sulfur and phosphorus concentrations, determined by the mass spectrometer, were used to explore possible trends in a series of UOC material, and the uncertainties were calculated using GUM workbench software. The triple quadrupole inductively coupled plasma – mass spectrometer method allows for the removal of interferences in the analysis of species.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Quadrupole Resonance for Substance Detection

This review paper provides a comprehensive overview of recent advances in nuclear quadrupole resonance (NQR) spectroscopy for substance detection, highlighting its principles, methodologies, and applications. The paper elucidates the fundamental physics underlying NQR spectroscopy, emphasizing the interaction between nuclear quadrupole moments and electric field gradients. It explores the various experimental techniques and instrumentation developments that have enabled the sensitive detection and precise characterization of substances containing quadrupolar nuclei. A significant portion of the survey is dedicated to discussing the diverse applications of NQR spectroscopy, including the detection of explosives, drug pharmaceuticals, and material authentication. Furthermore, the survey examines the challenges and limitations associated with NQR spectroscopy, including issues related to signal-to-noise ratio (SNR), temperature dependency, and substance restrictions. Strategies to overcome these challenges are discussed, offering insights into the future directions of NQR spectroscopy research that includes artificial intelligence (AI), internet of things (IoT) integration, incorporating a cloud database for NQR parameter storage, and multi-modal analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗