Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-G-TeP4-14: Quality Control of Treatment Planning Using Knowledge-Based Planning Across a System of Radiation Oncology Practices

Purpose: There is potentially a wide variation in plan quality for a certain disease site, even for clinics located in the same system of hospitals. We have used a prostate-specific knowledge-based planning (KBP) model as a quality control tool to investigate the variation in prostate treatment planning across a network of affiliated radiation oncology departments. Methods: A previously created KBP model was applied to 10 patients each from 4 community-based clinics (Clinics A, B, C, and D). The KBP model was developed using RapidPlan (Eclipse v13.5, Varian Medical Systems) from 60 prostate/prostate bed IMRT plans that were originally planned using an in-house treatment planning system at the central institution of the community-based clinics. The dosimetric plan quality (target coverage and normal-tissue sparing) of each model-generated plan was compared to the respective clinically-used plan. Each community-based clinic utilized the same planning goals to develop the clinically-used plans that were used at the main institution. Results: Across all 4 clinics, the model-generated plans decreased the mean dose to the rectum by varying amounts (on average, 12.5, 2.6, 4.5, and 2.7 Gy for Clinics A, B, C, and D, respectively). The mean dose to the bladder also decreased with the model-generated plans (5.4, 2.3, 3.0, and 4.1 Gy, respectively). The KBP model also identified that target coverage (D95%) improvements were possible for for Clinics A, B, and D (0.12, 1.65, and 2.75%) while target coverage decreased by 0.72% for Clinic C, demonstrating potentially different trade-offs made in clinical plans at different institutions. Conclusion: Quality control of dosimetric plan quality across a system of radiation oncology practices is possible with knowledge-based planning. By using a quality KBP model, smaller community-based clinics can potentially identify the areas of their treatment plans that may be improved, whether it be in normal-tissue sparing or improved target coverage. M. Matuszak has research funding for KBP from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

FC Site 4.0 - NLR Scanning Lidar (Halo XR+ 235) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 4.2 - NLR Scanning Lidar (Halo XR+ 199) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 1.9 - NLR Scanning Lidar (Halo XR+ 200) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

In-Line Optical Transmission Imaging of Decals for Quality Control - Task 3

Quality monitoring is a critical aspect for manufacturing systems. Ideally the monitoring would be done in-line, be non-contact, non-destructive, and fast. This would enable reduced scrap and higher throughput. This poster presents an optical transmission method for evaluating and mapping coatings. With the method shown in the poster we can visualize optical variations on the macro and micro scales. This allows us to see the overall trend in loading in both the cross web and down web directions. Furthermore, we can visualize defects such dewetting spots, streaks, clumps, and pinholes where there is a lack of coating. The optical transmission signal has been found to be proportional to the IrOx loading signal using XRF measurements. Therefore, an optical transmission setup can be installed in-line and allow for a fast, non-contact method for mapping loading variations and defects.

coating uniformity↗

Automatic Waveform Quality Control for Surface Waves Using Machine Learning

Surface-wave seismograms are widely used by researchers to study Earth’s interior and earthquakes. To extract information reliably and robustly from a suite of surface waveforms, the signals require quality control screening to reduce artifacts from signal complexity and noise. This process has usually been completed by human experts labeling each waveform visually, which is time consuming and tedious for large data sets. We explore automated approaches to improve the efficiency of waveform quality control processing by investigating logistic regression, support vector machines, K-nearest neighbors, random forests (RF), and artificial neural networks (ANN) algorithms. To speed up signal quality assessment, we trained these five machine learning (ML) methods using nearly 400,000 human-labeled waveforms. The ANN and RF models outperformed other algorithms and achieved a test accuracy of 92%. We evaluated these two best-performing models using seismic events from geographic regions not used for training. The results show that the two trained models agree with labels from human analysts but required only 0.4% of the time. Although the original (human) quality assignments assessed general waveform signal-to-noise, the ANN or RF labels can help facilitate detailed waveform analysis. Our investigations demonstrate the capability of the automated processing using these two ML models to reduce outliers in surface-wave-related measurements without human quality control screening.

58 GEOSCIENCES↗

The QCECOR Value-Added Product: Quality-Controlled Eddy Correlation Flux Measurements

Eddy correlation flux (ECOR) measurement system stations are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility to provide surface turbulence flux measurements. In recent years, ARM has significantly enhanced its ECOR systems and made them available at all its primary research observatories and mobile facilities. However, the original ECOR data were not corrected through common eddy correlation corrections and still contain suspicious data due to instrument and measurement uncertainties. Such uncertainties in the ECOR surface turbulence fluxes hampered their uses by the user community. To improve the ECOR data, we develop a value-added product (VAP) —the Quality-Controlled Eddy Correlation Flux (QCECOR) — by applying the following necessary corrections and quality control (QC) procedures: Eddy correlation corrections. Determination of the quality-controlled energy fluxes from the corrected ECOR fluxes. Stringent QC checks. Flagging possible incorrect fluxes due to hydrometeor impacts using the collocated surface energy balance system (SEBS) wetness measurements. The QCECOR VAP currently contains two variables: surface latent heat flux (LH) and sensible heat flux (SH), together with their QC flags. When SEBS are collocated with ECOR, the wetness measurements from SEBS are used to flag the LH that may be incorrect due to hydrometeors such as precipitation, dew, or frost. An indeterminate flag is given to those that fail the wetness test. The QCECOR data are currently available at the Southern Great Plains (SGP) atmospheric observatory for the ARM extended facilities of E1, E3, E5, E6, E10, E14, E16, E21, E24, E31, E33, E37, E38, E39, and E41 updated to 2018. The data are also available at the following AMF sites: PYE (Point Reyes, 2005), NIM (Niamey, Niger, 2006), FKB (Black Forest, Germany, 2007), HFE (Shouxian, China, 2008), GRW (Azores, 2009 to 2010), and MAO (Manacapuru, Brazil, 2014-2015). The algorithm is now in the process of moving to production mode. After that, QCECOR will run automatically for all available ARM sites.

47 OTHER INSTRUMENTATION↗

SU-D-BRB-02: Patient-Specific Rectal Toxicity Predictor Based Plan Quality Control for Prostate Stereotactic Body Radiation Therapy (SBRT)

Purpose: To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans. Methods: For prostate SBRT cases, four segments of rectal walls including peri-prostatic anterior rectal wall, peri-prostatic lateral rectal walls, peri-prostatic posterior rectal wall and rectum superior to prostate are identified as organs at risk and the circumference of rectal wall receiving more than 39 Gy (CRW39) and 24 Gy (CRW24) are rectal toxicity predictors. In this new geometry-dosimetry model, a patient geometry descriptor, differential circumference of rectal wall (dCRW) is used as model input geometry parameters and plan dosimetric endpoints CRW39 and CRW24 are output dosimetric parameters. Linear models are built to correlate dCRW to both CRW39 and CRW24 and established with both a linear regression method and a modified bagging ensemble machine learning method. 27 SBRT prostate cases are retrospectively studied from a dose-escalated clinical trial research. 20 prescribed 50 Gy SBRT cases are recruited to train the model and the other rescaled 7 cases are used to evaluated model feasibility and accuracy. Results: Each solved linear coefficient sequence related to CRW39 or CRW24 is a one-dimensional decreasing function of the distance from the PTV boundary, indicating that the different locations of each rectal circumference have different contributions to each particular dosimetric endpoint. The fitting errors for those trained 20 prostate SBRT cases are small with mean values of 2.39%, 2.45% relative to the endpoint values for SBRT rectal toxicity predictor CRW39 and CRW24 respectively. 1 out of 7 evaluation plans is identified as poor quality plan. After re-planning, the CRW39 and CRW24 can be reduced by 3.34% and 3%, without sacrificing PTV coverage. Conclusion: The proposed patient geometry-plan toxicity predictor model for SBRT plans can be successfully applied to plan quality control for prostate SBRT cases.

60 APPLIED LIFE SCIENCES↗

The mass production and quality control of RPCs for the Daya Bay Experiment

Resistive plate chambers will be used in the Daya Bay reactor neutrino experiment to help veto backgrounds created by cosmic-ray muons. The mass production of RPCs began in 2008 and by the end of 2009, 1600 RPCs (3500 m{sup 2}) had been produced and tested. This paper describes the production and quality control procedures, and quality assurance using cosmic-ray testing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Auditor and Quality Control Inspector Competency Model

The Energy Auditor (EA) and Quality Control Inspector (QCI) Competency model was developed to identify the soft skills, foundational competencies and define the levels of Knowledge, Skills, and Abilities (KSAs) required to successfully perform the tasks defined in the EA and QCI Job Task Analysis (JTAs), the U.S. Department of Energy (DOE) used the U.S. Department of Labor's (DOL) Competency Model Clearinghouse resources to develop a QCI and EA Competency Model. To keep the QCI and EA competency model consistent with other construction and energy management competency models, DOE and the National Renewable Energy Laboratory used the existing 'Residential Construction Competency Model' and the 'Advanced Commercial Building Competency Model' where appropriate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Quality control of meteorological data for the chemical stockpile emergency preparedness program.

The Chemical Stockpile Emergency Preparedness Program Meteorological Support Project ensures the accuracy and reliability of data acquired by meteorological monitoring stations located at seven U.S. Army chemical weapons depots where storage and weapons destruction (demilitarization) activities are ongoing. The data are delivered in real time to U.S. Army plume dispersion models, which are used to plan for and respond to a potential accidental release of a chemical weapons agent. The project provides maintenance, calibration, and audit services for the instrumentation; collection, automated screening, visual inspection, and analysis of the data; and problem reporting and tracking to carefully control the data quality. The resulting high-quality meteorological data enhance emergency response modeling and public safety.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Method for implementing non-destructive quality control of substrates and printed biological microarrays

A method and apparatus are provided for implementing non-destructive quality control of substrates and printed biological microarrays. A method and apparatus are provided for implementing quality control of gel-based microarrays prepared by dispensing a gel-forming composition on a solid substrate. The method utilizes the difference between the wettability properties of a supporting substrate and a gel, where the gel is hydrophilic. Condensation of vapor of a chemically inert water-soluble liquid, such as water or glycerol, on the surface of a substrate under inspection creates a layer of tiny droplets that affect both transmission and scattering of light on the surface. A pattern of condensation, characterized by spatial distribution, average size of the droplets and spacing between the droplets, reflects variation in wetting properties of the substrate. The pattern of condensation circumscribes printed microarray features to be non-destructively imaged and analyzed.

59 BASIC BIOLOGICAL SCIENCES↗

Multifamily Quality Control Inspector Job/Task Analysis and Report: September 2013

The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Quality Control Inspector JTA identifies and catalogs all of the tasks performed by multifamily quality control inspectors, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ATLAS ITk strip sensor quality control procedures and testing site qualification

Abstract The high-luminosity upgrade of the Large Hadron Collider, scheduled to become operational in 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker. Radiation hard n + -in-p micro-strip silicon sensors were developed by the ATLAS Inner Tracker strip collaboration and are produced by Hamamatsu Photonics K.K. Production of the total amount of 22000 strip sensors has started in 2020 and will continue until 2025. The ATLAS strip sensor collaboration has the responsibility to monitor the quality of the fabricated devices by performing detailed measurements of individual sensor characteristics and by comparing the obtained results with the tests done by the manufacturer. Dedicated Quality Control procedures were developed to check whether the delivered large-format sensors adhere to the ATLAS specifications. The institutes performing the Quality Control testing of the pre-production and production ATLAS ITk strip sensors had to initially be qualified for multiple high-throughput tests by successfully completing the Site Qualification process. The Quality Control procedures and the qualification process are described in this paper.

Instruments & Instrumentation↗

Photoluminescence-based quality control for thin film absorber layers of photovoltaic devices

A time-resolved photoluminescence-based system providing quality control during manufacture of thin film absorber layers for photovoltaic devices. The system includes a laser generating excitation beams and an optical fiber with an end used both for directing each excitation beam onto a thin film absorber layer and for collecting photoluminescence from the absorber layer. The system includes a processor determining a quality control parameter such as minority carrier lifetime of the thin film absorber layer based on the collected photoluminescence. In some implementations, the laser is a low power, pulsed diode laser having photon energy at least great enough to excite electron hole pairs in the thin film absorber layer. The scattered light may be filterable from the collected photoluminescence, and the system may include a dichroic beam splitter and a filter that transmit the photoluminescence and remove scattered laser light prior to delivery to a photodetector and a digital oscilloscope.

14 SOLAR ENERGY↗

Shifting Sands: Modulating Interactions and Outputs of the CHIP‐Hsp70/HOP‐Hsp70 Protein Quality Control Complexes

The 70‐kilodalton heat shock protein (Hsp70) interacts with tetratricopeptide repeat (TPR) domains of CHIP (C‐terminus of Hsp70 Interacting Protein) and HOP (Hsp Organizing Protein) using a two‐carboxylate clamp binding mechanism. Differential affinity for the TPR domains of CHIP and HOP are achieved through interactions with the six residues preceding the carboxy‐terminal Asp 641 of Hsp70. In particular, phosphorylation of Hsp70 Thr 636 produces a dramatic swing in binding affinities that shift preferential formation of CHIP/Hsp70 complexes to preferential formation of HOP/Hsp70 complexes. Given that CHIP‐Hsp70 complexes promote ubiquitin‐mediated degradation of Hsp70‐chaperoned clients while HOP‐Hsp70 complexes promote refolding of Hsp70‐chaperoned clients, phosphorylation of Hsp70 Thr 636 acts as a switch that directs the output and function of cellular protein quality control. Herein, through biophysical assays and new structures of CHIP‐Hsp70 and Hop‐Hsp70 we identify the molecular mechanism that enables phosphorylation‐driven switching that directs interactions within the CHIP‐Hsp70/HOP‐Hsp70 protein quality control complexes. We also present a structure‐guided mutation of Hsp70 that bypasses Thr 636 phosphorylation‐driven switching by recovering affinity of CHIP for phosphorylated Hsp70, thereby redirecting Hsp70 to preferentially bind to CHIP. This structure‐guided mutation corrects a binding defect present in wild type CHIP and provides a system for studying the effect of shifting output of the CHIP‐Hsp70/HOP‐Hsp70 protein quality control complexes toward chaperoned ubiquitination via the CHIP‐Hsp70 complex. Support or Funding Information The authors acknowledge financial support from the US National Science Foundation (Award No. MCB 1552113 to RCP), the American Heart Association (Award No. 16SDG26960000 to RCP), the Burroughs Wellcome Fund (Award No. 1014031 to RCP), and institutional support from Miami University through the Robert H. and Nancy J. Blayney Professorship (to RCP). The Advanced Light Source is supported by the US Department of Energy under contract number DE‐AC03‐76SF00098 at Lawrence Berkeley National Laboratory.

Page, Richard C.↗

Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials

Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volume histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗