Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quench Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗

Acoustic diagnostic system and method for superconducting devices operating in gas or liquid

A novel system and method for detecting a quench of a superconducting conductor and detecting abnormal behavior of a superconducting conductor using acoustic sensor technology in the coolant of a superconducting cable and/or magnet is disclosed. This system and method is not only limited to use for superconductors, but also may be used for any device disposed in liquid and gas. Acoustic sensors are installed along a coolant space of a superconducting conductor and monitor coolant conditions. By monitoring acoustic changes, temperature changes or coolant flow disruption can be detected very quickly by an acoustic sensor array. By disposition of the acoustic sensor array in a coolant flow channel, the acoustic sensor system can quickly detect a local condition, such as the thermal status (temperature) of a superconducting cable and magnet with precise spatial resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploration of signal processing methods for superconducting magnet and quench data

Quenching is the phenomenon of a superconducting magnetic material carrying current transitioning into a regular conducting material. This may cause severe and irreparable damage to the superconductor due to Joule heating. The Magnet Department at Fermi National Accelerator Laboratory (FNAL) has acquired experimental data through quench antenna arrays that are recorded when the quench is detected. These data are in terms of voltage signals that are sampled at 100kHz for several minutes. There are multiple channels and each channel provides a data set of more than 20 million observations, while there is one channel, called the trigger channel which shows the time when quench is detected. Despite some advancements that were made including machine learning, data complexity still shadows the progress. In this work, we studied a multi-resolution analysis of the quench antenna data through the Haar wavelet transform. In particular, we applied the maximally overlapped discrete w avelet transform (MODWT) of a suitable level L to the given data and then projected it onto the wavelet basis. This decomposes a given signal (Original data) $x ϵ \mathbb{R}^N$ into $L + 1$ subspaces of $\mathbb{R}^N$. One of the subspaces called the approximation, captures the trend of the signal, and the others, called the details, capture the fluctuations at different frequency bands. This decomposition provides a clear trend of the data at a suitable level and also various activities (spikes) are seen in the details of the decomposition at every level. These spikes might reveal some information about the quench under investigation but in any case, give information about magnet behavior. Also, this decomposition is seen to be very useful in removing noise present in the data due to the source or mechanism of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Full-length Quench Antenna for MQXFA Production Series Quadrupole Magnet Testing

The MQXFA production series quadrupoles being built for the Hi-Lumi (HL) LHC upgrade by the US Accelerator Upgrade Project (US-HL-LHC AUP) will have very limited instrumentation for characterizing quench events that occur during magnet training and performance validation testing. In order to understand the origin of the quenches, and whether they have some implication for ongoing magnet fabrication, it was decided to build a full-length Quench Antenna (QA) with axial resolution of 50mm to be employed during cold testing in the anticryostat used for magnetic measurements. The goal is to have fineresolution, full-length coverage detection of quench events axially, as well as to have azimuthal resolution on the order of the cable width (about 1 degree for the cross-section), in a device that can be used both for vertical and horizontal testing. To achieve this, a 5m long QA with 128 channels of high-speed data acquisition has been designed and fabricated. The cylindrical antenna features an array of 12 full-length, dipole- and quadrupole-bucked coils positioned radially in the QA interior for azimuthal localization, and over 100 individual channels of short, high-sensitivity, antennas etched as flexible PCB circuits (which also buck dipole and quadrupole fields) wrapped circumferentially on the cylinder exterior in steps of 50mm along the magnet length for axial detection. This report discusses the design, construction and analysis of the MQXFA QA, and first results from using the antenna during quench testing in the production magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond two-photon-resonant parametric four-wave mixing detection of atomic hydrogen

Here, we demonstrate an ultrafast parametric four-wave mixing method for the collisional-quenching-free detection of atomic hydrogen. Two photons of 243 nm light resonantly excite the n = 1 to n = 2 transition of atomic hydrogen, and a third probe photon scatters from the electronic coherence to generate the parametric emission of a degenerate signal photon. Laser-induced photofragmentation fluorescence from water, also excited with the same 243 nm pulses, is used as a convenient method to visualize beam overlap in space and time. The femtosecond time resolution enables the suppression of unwanted nonresonant contributions to the signal and separation from resonant mixing in water molecules because of the significantly different coherence lifetimes. A folded BOXCARS phase-matching configuration yields a spatially isolated, laser-like, signal beam, amenable to measurements in highly luminous backgrounds. Measurements in an H 2 /CH 4 /air flame demonstrate quantitative agreement with simulated H-atom concentration profiles. A coherence decay time constant of 42 ps is recorded in the atmospheric pressure flame.

Kliewer, Christopher Jesse [Sandia National Labora↗

In-field strain and temperature measurements in a (RE)Ba 2 Cu 3 O 7–x coil via Rayleigh-backscattering interrogated optical fibers

(RE)Ba 2 Cu 3 O 7-x (REBCO) conductors have overcome technical challenges related to manufacturing quality, length homogeneity, scale-up of piece-length, and joints. There is one remaining technical challenge, however, which is common to all high temperature superconductors and lies in effective detection of failure to prevent material degradation. An innovative technique based on optical fibers interrogated by Rayleigh backscattering has been shown to have advantages over voltage taps at detecting incipient faults. Prior work has experimentally demonstrated the technique in several implementation scenarios, including direct integration of optical fibers into superconducting conductors and cables to create a class of ‘SMART’ conductors and cables that are able to monitor their own health. In this paper, the magnet monitoring technique based on Rayleigh backscattering interrogated optical fibers has been experimentally studied in a model coil subject to external magnetic field, where different fiber integration methods are used to increase selectivity of the fiber sensor to temperature. Results show that the spectral shift displays different features during strain and thermal transients. The implications of the results in terms of potential and limitations of each sensor as well as strain-temperature decoupling are discussed.

36 MATERIALS SCIENCE↗

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears “quenched” compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below 50 keV ), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV , with kinetic energies in between 2 keV and 13 keV in 100 mbar of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as a reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by IQF (E K )=E$^α_K$ / (β+E$^α_K$) with α=0.70±0.08 and β=1.32±0.17 . In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching 33% at 2 keV .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of young (≤20 Myr) stellar populations in apparently quenched low-mass galaxies using red spectral line indices

ABSTRACT We report on the detection of a small contribution (around and below 1 per cent in mass) from young stellar components with ages ≤20 Myr in low-mass galaxies purposely selected from the MaNGA survey to be already-quenched systems. Among the sample of 28 galaxies, 8 of them show signatures of having suffered a very recent burst of star formation. The detection has been done through the analysis of line-strength indices in the red spectral range [5700,8800] Å. The increasing contribution of red supergiants to this red regime is responsible for a deviation of the index measurements with respect to their position within the model grids in the standard spectral range [3600,5700] Å. We demonstrate that a combination of red indices, as well as a qualitative assessment of the mean luminosity-weighted underlying stellar population, is required in order to distinguish between a true superyoung population and other possible causes of this deviation, such as abundance ratio variations. Our result implies that many presumably quenched low-mass galaxies actually contain gas that is triggering some level of star formation. They have, therefore, either accreted external gas, internally recycled enough gas from stellar evolution to trigger new star formation, or they kept a gas reservoir after the harassment or stripping process that quenched them in the first place. Internal processes are favoured since we find no particular trends between our non-quenched galaxies and their environment, although more work is needed to fully discard an external influence.

de Lorenzo-Cáceres, A.↗

Pulsed Power Supply for Magnet Quench Training

Superconducting magnets typically go through aseries of spontaneous “training” quenches as their current isincreased towards its design value. To decrease the number ofthese quenches, a device has been designed to boost the magnetcurrent at the moment a quench has been detected and beforemagnet protection has been initiated. The aim of the boost is todrive the magnet coil further along towards its maximum currentwith each training quench, and hence reduce the number ofquenches required.

43 PARTICLE ACCELERATORS↗

Detecting Spin-Bath Polarization with Quantum Quench Phase Shifts of Single Spins in Diamond

Single-qubit sensing protocols can be used to measure qubit-bath coupling parameters. However, for sufficiently large coupling, the sensing protocol itself perturbs the bath, which is predicted to result in a characteristic response in the sensing measurements. Here, we observe this bath perturbation, also known as a quantum quench, by preparing the nuclear spin bath of a nitrogen-vacancy (NV) center in polarized initial states and performing phase-resolved spin-echo measurements on the NV electron spin. These measurements reveal a time-dependent phase determined by the initial state of the bath. We derive the relationship between the sensor phase and the Gaussian spin-bath polarization and apply it to reconstruct both the axial and transverse polarization components. Using this insight, we optimize the transfer efficiency of our dynamic nuclear polarization sequence. This technique for directly measuring bath polarization may assist in preparing high-fidelity quantum memory states, improving nanoscale NMR methods, and investigating non-Gaussian quantum baths.

36 MATERIALS SCIENCE↗

Visible-Light-Driven, Iridium-Catalyzed Hydrogen Atom Transfer: Mechanistic Studies, Identification of Intermediates, and Catalyst Improvements

The harvesting of visible light is a powerful strategy for the synthesis of weak chemical bonds involving hydrogen that are below the thermodynamic threshold for spontaneous H 2 evolution. Piano-stool iridium hydride complexes are effective for the bluelight- driven hydrogenation of organic substrates and contrathermodynamic dearomative isomerization. In this work, a combination of spectroscopic measurements, isotopic labeling, structure–reactivity relationships, and computational studies has been used to explore the mechanism of these stoichiometric and catalytic reactions. Photophysical measurements on the iridium hydride catalysts demonstrated the generation of long-lived excited states with principally metal-to-ligand charge transfer (MLCT) character. Transient absorption spectroscopic studies with a representative substrate, anthracene revealed a diffusion-controlled dynamic quenching of the MLCT state. The triplet state of anthracene was detected immediately after the quenching events, suggesting that triplet–triplet energy transfer initiated the photocatalytic process. The key role of triplet anthracene on the post-energy transfer step was further demonstrated by employing photocatalytic hydrogenation with a triplet photosensitizer and a HAT agent, hydroquinone. DFT calculations support a concerted hydrogen atom transfer mechanism in lieu of stepwise electron/proton or proton/electron transfer pathways. Kinetic monitoring of the deactivation channel established an inverse kinetic isotope effect, supporting reversible C(sp 2 )–H reductive coupling followed by rate-limiting ligand dissociation. Mechanistic insights enabled design of a piano-stool iridium hydride catalyst with a rationally modified supporting ligand that exhibited improved photostability under blue light irradiation. The complex also provided improved catalytic performance toward photoinduced hydrogenation with H 2 and contra-thermodynamic isomerization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron response of the TLYC scintillator

The response of the recently developed Tl 2 LiYCl 6 (Ce) scintillator to neutrons was measured and the 35 Cl(n,p) channel observed in the material for the first time. The scintillator was exposed to a 252 Cf source mounted within a parallel-plate avalanche counter for fission-fragment coincident measurements. Proton- and -like events are selected with the pulse-shape discrimination technique. Additionally, comparison of energy-deposition and time-of-flight allows the quenching of the different channels to be assessed. The 6 Li(n,t) channel is found to have its energy quenched to 37(1)% relative to -ray detection, while the proton energy deposition spectrum is quenched to 60(1)%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DECAF Cross-device characterization of tokamak disruptions indicated by abnormalities in plasma vertical position and current

Abnormal (deviating from target) variations in the plasma vertical position Z and current I p (such as vertical displacements, transient I p 'spikes' and quenches) constitute common elements of a disruption, a phenomenon that is to be mitigated, or ultimately avoided in future reactor-relevant tokamaks. While those abnormalities are generally recognized cross-shot and cross-device, details in terms of appearance (or not) and order of those abnormalities in disruption event chains is bound with the plasma state at the time of the chain initiation. Detection of those abnormalities is thus indicative not only of the onset of the plasma collapse itself, but also of the disruption driving cause that is promoted at the particular plasma state. Here, occurrence of disruptions, explored via detection of a Ip quench, and analysis of disruption event chains constituted by Ip and Z abnormalities, is reported for in total 7 full years of operation of 3 devices (KSTAR, MAST-U and NSTX-U) using the DECAFTM code expanded tools and capabilities. It is shown that the disruption occurrence depends not only on details of the plasma state, but also on (device-dependent) technical elements of the shot exit scenario. A year-to-year change in main disruption causes and a reduction of the disruptivity rate, bound with device and operation upgrades, are reported. Particular trigger instances of disruption event chains (and the full chains, when applicable) are shown to occupy different parts of the operation space diagrams, in accordance with prior expectation. Plasma elongation is identified as an important factor influencing details of the chains and its role will be further explored.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of a fluorescent short-lifetime oxygen nanosensor by coupling of an exciplex forming dye pair

Typical oxygen-sensitive dyes have lifetimes in the μs-ms regime for sensitive oxygen detection based on molecular quenching. Due to the long triplet-state lifetimes and poor quenching efficiency of these probes, it has been difficult to develop short lifetime probes. We have developed oxygen sensors using a short-lifetime dye (∼30–60 ns) that forms an anthracene-aniline exciplex, which is quenched by molecular oxygen through an excited-state charge transfer mechanism. To achieve measurements in aqueous systems, we have tethered the dyes together via a C3 alkyl linker to facilitate greater exciplex formation at low dye concentration (20 μg mL −1 ) and encapsulated the resulting compound into polymeric nanoparticles to form an aqueous-dispersible short-lifetime oxygen nanosensor. The sensors emit at 420 nm (unfolded dye) and 500 nm (exciplex), and the ratiometric Stern-Volmer Constant is 1.52 ± 0.02 L mol −1 , showing good sensitivity from 0 % to 40 % dissolved oxygen without the tradeoff of a long lifetime needed for direct molecular quenching. In this paper, we characterize this sensor for both lifetime-based measurements using time-correlated single-photon counting and ratiometric intensity-based measurements using the unfolded dye emission as an internal reference peak.

Biological and medical sciences↗

Re-assembly and test of COMB dipole magnet with STAR® wires

Fermilab is developing the Conductor on Molded Barrel (COMB) magnet technology that works well with round REBCO conductors. COMB-STAR-1 magnet based on STAR wire by AMPeers was fabricated and tested in liquid nitrogen in 2023. The magnet demonstrated >90 Ic retention in the coils (before/after winding). Even though the magnet was not originally designed for operation at lower than 77 K temperatures, it was decided to test it in liquid helium to: - check the instrumentation and the DAQ system; - check the ability to detect resistive transitions or quenches and to protect the magnet; - gather the information on possible magnet design chances and upgrades of the test facility for future testing of HTS magnets. The magnet was re-assembled with a larger iron yoke and the axial supports and tested in liquid helium in 2024 at Fermilab s Vertical Magnet Test Facility (VMTF). It was the first HTS magnet test at that facility ever.

Kashikhin, Vadim↗