Search NASA⌕ Search

SEARCH · Search NASA

Results for “R2)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ST5 Observations of the Imbalance of Region 1 and 2 Field-Aligned Currents and its Implication to Ionospheric Closure Currents

A major unsolved question in the physics of ionosphere-magnetosphere coupling is how field-aligned currents (FACs) close. In order to maintain the divergence free condition, overall downward FACs (carried mainly by upward electrons) must eventually balance the overall upward FACs associated with the precipitating electrons through ionospheric Pedersen currents. Although much of the current closure may take place via local Pedersen currents flowing between Region 1 (R1) and Region 2 (R2) FACs, there is a generally an imbalance, i.e., more currents in R1 than in R2, in total currents between them. The net currents may be closed within R1 via cross-polar cap Pedersen currents. In this study, we use the magnetic field observations from Space Technology 5 mission to quantify the imbalance of R1 and R2 currents. We will determine the net R1-R2 currents under various solar wind conditions and discuss the implication of such imbalance to the ionospheric closure currents.

Le, G.↗

Regional Distribution of Forest Height and Biomass from Multisensor Data Fusion

Elevation data acquired from radar interferometry at C-band from SRTM are used in data fusion techniques to estimate regional scale forest height and aboveground live biomass (AGLB) over the state of Maine. Two fusion techniques have been developed to perform post-processing and parameter estimations from four data sets: 1 arc sec National Elevation Data (NED), SRTM derived elevation (30 m), Landsat Enhanced Thematic Mapper (ETM) bands (30 m), derived vegetation index (VI) and NLCD2001 land cover map. The first fusion algorithm corrects for missing or erroneous NED data using an iterative interpolation approach and produces distribution of scattering phase centers from SRTM-NED in three dominant forest types of evergreen conifers, deciduous, and mixed stands. The second fusion technique integrates the USDA Forest Service, Forest Inventory and Analysis (FIA) ground-based plot data to develop an algorithm to transform the scattering phase centers into mean forest height and aboveground biomass. Height estimates over evergreen (R2 = 0.86, P < 0.001; RMSE = 1.1 m) and mixed forests (R2 = 0.93, P < 0.001, RMSE = 0.8 m) produced the best results. Estimates over deciduous forests were less accurate because of the winter acquisition of SRTM data and loss of scattering phase center from tree ]surface interaction. We used two methods to estimate AGLB; algorithms based on direct estimation from the scattering phase center produced higher precision (R2 = 0.79, RMSE = 25 Mg/ha) than those estimated from forest height (R2 = 0.25, RMSE = 66 Mg/ha). We discuss sources of uncertainty and implications of the results in the context of mapping regional and continental scale forest biomass distribution.

Yu, Yifan↗

Robonaut 2 - Initial Activities On-Board the ISS

Robonaut 2, or R2, arrived on the International Space Station in February 2011 and is currently undergoing testing in preparation for it to become, initially, an Intra-Vehicular Activity (IVA) tool and then evolve into a system that can perform Extra-Vehicular Activities (EVA). After the completion of a series of system level checks to ensure that the robot traveled well on-board the Space Shuttle Atlantis, ground control personnel will remotely control the robot to perform free space tasks that will help characterize the differences between earth and zero-g control. For approximately one year, the fixed base R2 will perform a variety of experiments using a reconfigurable task board that was launched with the robot. While working side-by-side with human astronauts, Robonaut 2 will actuate switches, use standard tools, and manipulate Space Station interfaces, soft goods and cables. The results of these experiments will demonstrate the wide range of tasks a dexterous humanoid can perform in space and they will help refine the methodologies used to control dexterous robots both in space and here on earth. After the trial period that will evaluate R2 while on a fixed stanchion in the US Laboratory module, NASA plans to launch climbing legs that when attached to the current on-orbit R2 upper body will give the robot the ability to traverse through the Space Station and start assisting crew with general IVA maintenance activities. Multiple control modes will be evaluated in this extra-ordinary ISS test environment to prepare the robot for use during EVAs. Ground Controllers will remotely supervise the robot as it executes semi-autonomous scripts for climbing through the Space Station and interacting with IVA interfaces. IVA crew will locally supervise the robot using the same scripts and also teleoperate the robot to simulate scenarios with the robot working alone or as an assistant during space walks.

Diftler, M. A.↗

Robonaut 2 and You: Specifying and Executing Complex Operations

Crew time is a precious resource due to the expense of trained human operators in space. Efficient caretaker robots could lessen the manual labor load required by frequent vehicular and life support maintenance tasks, freeing astronaut time for scientific mission objectives. Humanoid robots can fluidly exist alongside human counterparts due to their form, but they are complex and high-dimensional platforms. This paper describes a system that human operators can use to maneuver Robonaut 2 (R2), a dexterous humanoid robot developed by NASA to research co-robotic applications. The system includes a specification of constraints used to describe operations, and the supporting planning framework that solves constrained problems on R2 at interactive speeds. The paper is developed in reference to an illustrative, typical example of an operation R2 performs to highlight the challenges inherent to the problems R2 must face. Finally, the interface and planner is validated through a case-study using the guiding example on the physical robot in a simulated microgravity environment. This work reveals the complexity of employing humanoid caretaker robots and suggest solutions that are broadly applicable.

Baker, William↗

Unsteady Flow Field in a Multistage Axial Flow Compressor

The flow field in a multistage compressor is three-dimensional, unsteady, and turbulent with substantial viscous effects. Some of the specific phenomena that has eluded designers include the effects of rotor-stator and rotor-rotor interactions and the physics of mixing of velocity, pressure, temperature and velocity fields. An attempt was made, to resolve experimentally, the unsteady pressure and temperature fields downstream of the second stator of a multistage axial flow compressor which will provide information on rotor-stator interaction effects and the nature of the unsteadiness in an embedded stator of a three stage axial flow compressor. Detailed area traverse measurements using pneumatic five hole probe, thermocouple probe, semi-conductor total pressure probe (Kulite) and an aspirating probe downstream of the second stator were conducted at the peak efficiency operating condition. The unsteady data was then reduced through an ensemble averaging technique which splits the signal into deterministic and unresolved components. Auto and cross correlation techniques were used to correlate the deterministic total temperature and velocity components (acquired using a slanted hot-film probe at the same measurement locations) and the gradients, distributions and relative weights of each of the terms of the average passage equation were then determined. Based on these measurements it was observed that the stator wakes, hub leakage flow region, casing endwall suction surface corner region, and the casing endwall region away from the blade surfaces were the regions of highest losses in total pressure, lowest efficiency and highest levels of unresolved unsteadiness. The deterministic unsteadiness was found to be high in the hub and casing endwall regions as well as on the pressure side of the stator wake. The spectral distribution of hot-wire and kulite voltages shows that at least eight harmonics of all three rotor blade passing frequencies are present at this measurement location. In addition to the basic three rotor blade passing frequencies (R1, R2 and R3) and their harmonics, various difference frequencies such as (2R1 -R2) and (2R3-R2) and their harmonics are also observed. These difference frequencies are due to viscous and potential interactions between rotors 1, 2 and 3 which are sensed by both the total pressure and aspirating probes at this location. Significant changes occur to the stator exit flow features with passage of the rotor upstream of the stator. Because of higher convection speeds of the rotor wake on the suction surface of the downstream stator than on the pressure side, the chopped rotor wake was found to be arriving at different times on either side of the stator wake. As the rotor passes across the stator.

Suryavamshi, N.↗

Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.

Non-NASA Center↗

Time-on-task decrements in "steer clear" performance of patients with sleep apnea and narcolepsy

Loss of attention with time-on-task reflects the increasing instability of the waking state during performance in experimentally induced sleepiness. To determine whether patients with disorders of excessive sleepiness also displayed time-on-task decrements indicative of wake state instability, visual sustained attention performance on "Steer Clear," a computerized simple RT driving simulation task, was compared among 31 patients with untreated sleep apnea, 16 patients with narcolepsy, and 14 healthy control subjects. Vigilance decrement functions were generated by analyzing the number of collisions in each of six four-minute periods of Steer Clear task performance in a mixed-model analysis of variance and linear regression equations. As expected, patients had more Steer Clear collisions than control subjects (p=0.006). However, the inter-subject variability in errors among the narcoleptic patients was four-fold that of the apnea patients, and 100-fold that of the controls volunteers; the variance in errors among untreated apnea patients was 27-times that of controls. The results of transformed collision data revealed main effects for group (p=0.006), time-on-task (p=0.001), and a significant interaction (p=0.022). Control subjects showed no clear evidence of increasing collision errors with time-on-task (adjusted R2=0.22), while apnea patients showed a trend toward vigilance decrement (adjusted R2=0.42, p=0.097), and narcolepsy patients evidenced a robust linear vigilance decrement (adjusted R2=0.87, p=0.004). The association of disorders of excessive somnolence with escalating time-on-task decrements makes it imperative that when assessment of neurobehavioral performance is conducted in patients, it involves task durations and analyses that will evaluate the underlying vulnerability of potentially sleepy patients to decrements over time in tasks that require sustained attention and timely responses, both of which are key components in safe driving performance.

NASA Discipline Space Human Factors↗

An ecologic study of dietary links to prostate cancer

BACKGROUND: The etiology of prostate cancer has not been fully resolved in the scientific and medical literature, although the non-fat portion of milk and calcium are emerging as leading dietary risk factors, with lycopene (found in tomatoes) and vitamin D apparently being risk reduction factors. METHODS: The ecologic (multi-country statistical) approach is used to study dietary links to prostate cancer. Mortality data from 1986 for various age groups in 41 countries are compared with national consumer macronutrient supply values for 1983 and tomato supply values for 1985. RESULTS: For 28 countries with more than five Kcal/day of tomatoes in the consumer supply, a linear combination of non-fat milk (risk factor) and tomatoes (risk reduction factor) was found to have the highest statistical association with prostate cancer mortality rates for men over the age of 35, with the Pearson regression coefficient (R2) for those aged 65-74 years = 0.67 and p < 0.001. For the 13 countries with fewer than six Kcal/day of tomatoes, non-fat milk had the highest association (R2 = 0.92, p < 0.001 for men aged 65-74 years). For 41 countries combined, the non-fat portion of milk had the highest association with prostate cancer mortality rates (R2 = 0.73, p < 0.001 for men aged 65-74 years). CONCLUSIONS: These results support the results of several cohort studies which found the non-fat portion of milk to have the highest association with prostate cancer, likely due to the calcium, and tomatoes to reduce the risk of prostate cancer, most likely due to lycopene.

Diet/adverse effects↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

NASA Discipline Number 26-10↗

In vivo assessment of forearm bone mass and ulnar bending stiffness in healthy men

The cross-sectional bending stiffness EI of the ulna was measured in vivo by mechanical resistance tissue analysis (MRTA) in 90 men aged 19-89 years. MRTA measures the impedance response of low-frequency vibrations to determine EI, which is a reflection of elastic modulus E and moment of inertia I for the whole ulna. EI was compared to conventional estimates of bone mineral content (BMC), bone width (BW), and BMC/BW, which were all measured by single-photon absorptiometry. Results obtained from the nondominant ulna indicate that BW increases (r = 0.27, p = 0.01) and ulnar BMC/BW decreases (r = -0.31, p < or = 0.005) with age. Neither BMC nor EI declined with age. The single best predictor of EI was BW (r2 = 0.47, p = 0.0001), and further small but significant contributions were made by BMC (r2 = 0.53, p = 0.0001) and grip strength (r2 = 0.55, p = 0.0001). These results suggest that the resistance of older men to forearm fracture is related to age-associated changes in the moment of inertia achieved by redistributing bone mineral farther from the bending axis. We conclude that the in vivo assessment of bone geometry offers important insights to the comprehensive evaluation of bone strength.

NASA Center ARC↗

ST5 Observations of the Imbalance of Region 1 and 2 Field-Aligned Currents and its Implication to the Cross-Polar Cap Pedersen Currents

In this study, we use the in-situ magnetic field observations from Space Technology 5 mission to quantify the imbalance of Region 1 (R1) and Region 2 (R2) currents. During the three-month duration of the ST5 mission, geomagnetic conditions range from quiet to moderately active. We find that the R1 current intensity is consistently stronger than the R2 current intensity both for the dawnside and the duskside large-scale field-aligned current system. The net currents flowing into (out of) the ionosphere in the dawnside (duskside) are in the order of 5% of the total R1 currents. We also find that the net currents flowing into or out of the ionosphere are controlled by the solar windmagnetosphere interaction in the same way as the field-aligned currents themselves are. Since the net currents due to the imbalance of the R1 and R2 currents require that their closure currents flow across the polar cap from dawn to dusk as Pedersen currents, our results indicate that the total amount of the cross-polar cap Pedersen currents is in the order of approximately 0.1 MA. This study, although with a very limited dataset, is one of the first attempts to quantify the cross-polar cap Pedersen currents. Given the importance of the Joule heating due to Pedersen currents to the high-latitude ionospheric electrodynamics, quantifying the cross-polar cap Pedersen currents and associated Joule heating is needed for developing models of the magnetosphere-ionosphere coupling.

Le, Guan↗

Robonaut 2 - The First Humanoid Robot in Space

NASA and General Motors have developed the second generation Robonaut, Robonaut 2 or R2, and it is scheduled to arrive on the International Space Station in late 2010 and undergo initial testing in early 2011. This state of the art, dexterous, anthropomorphic robotic torso has significant technical improvements over its predecessor making it a far more valuable tool for astronauts. Upgrades include: increased force sensing, greater range of motion, higher bandwidth and improved dexterity. R2 s integrated mechatronics design results in a more compact and robust distributed control system with a faction of the wiring of the original Robonaut. Modularity is prevalent throughout the hardware and software along with innovative and layered approaches for sensing and control. The most important aspects of the Robonaut philosophy are clearly present in this latest model s ability to allow comfortable human interaction and in its design to perform significant work using the same hardware and interfaces used by people. The following describes the mechanisms, integrated electronics, control strategies and user interface that make R2 a promising addition to the Space Station and other environments where humanoid robots can assist people.

Diftler, M. A.↗

Space Technology 5 (ST-5) Observations of the Imbalance of Region 1 and 2 Field-Aligned Currents

Space Technology 5 (ST-5) is a three micro-satellite constellation deployed into a 300 x 4500 km, dawn-dusk, sun-synchronous polar orbit from March 22 to June 21, 2006, for technology validations. In this study, we use the in-situ magnetic field observations from Space Technology 5 mission to quantify the imbalance of Region 1 (R1) and Region 2 (R2) currents. During the three-month duration of the ST5 mission, geomagnetic conditions range from quiet to moderately active. We find that the R1 current intensity is consistently stronger than the R2 current intensity both for the dawnside and the duskside large-scale field-aligned current system. The net currents flowing into (out of) the ionosphere in the dawnside (duskside) are in the order of 5% of the total RI currents. We also find that the net currents flowing into or out of the ionosphere are controlled by the solar wind-magnetosphere interaction in the same way as the field-aligned currents themselves are. Since the net currents due to the imbalance of the R1 and R2 currents require that their closure currents flow across the polar cap from dawn to dusk as Pedersen currents, our results indicate that the total amount of the cross-polar cap Pedersen currents is in the order of approx. 0.1 MA. This study, although with a very limited dataset, is one of the first attempts to quantify the cross-polar cap Pedersen currents. Given the importance of the Joule heating due to Pedersen currents to the high-latitude ionospheric electrodynamics, quantifying the cross-polar cap Pedersen currents and associated Joule heating is needed for developing models of the magnetosphere-ionosphere coupling.

Le, Guan↗

ST5 Observations of the Imbalance of Region 1 and 2 Field-Aligned Currents and Its Implication to the Cross-Polar Cap Pedersen Currents

In this study, we use the in-situ magnetic field observations from Space Technology 5 mission to quantify the imbalance of Region 1 (R1) and Region 2 (R2) currents. During the three-month duration of the ST5 mission, geomagnetic conditions range from quiet to moderately active. We find that the R1 current intensity is consistently stronger than the R2 current intensity both for the dawnside and the duskside large-scale field-aligned current system. The net currents flowing into (out of) the ionosphere in the dawnside (duskside) are in the order of 5% of the total R1 currents. We also find that the net currents flowing into or out of the ionosphere are controlled by the solar wind-magnetosphere interaction in the same way as the field-aligned currents themselves are. Since the net currents due to the imbalance of the R1 and R2 currents require that their closure currents flow across the polar cap from dawn to dusk as Pedersen currents, our results indicate that the total amount of the cross-polar cap Pedersen currents is in the order of ~ 0.1 MA. This study, although with a very limited dataset, is one of the first attempts to quantify the cross-polar cap Pedersen currents. Given the importance of the Joule heating due to Pedersen currents to the high-latitude ionospheric electrodynamics, quantifying the cross-polar cap Pedersen currents and associated Joule heating is needed for developing models of the magnetosphere-ionosphere coupling.

Le, Guan↗

Evaluation of the Event Driven Phenology Model Coupled with the VegET Evapotranspiration Model Through Comparisons with Reference Datasets in a Spatially Explicit Manner

A new model coupling scheme with remote sensing data assimilation was developed for estimation of daily actual evapotranspiration (ET). The scheme represents a mix of the VegET, a physically based model to estimate ET from a water balance, and an event driven phenology model (EDPM), where the EDPM is an empirically derived crop specific model capable of producing seasonal trajectories of canopy attributes. In this experiment, the scheme was deployed in a spatially explicit manner within the croplands of the Northern Great Plains. The evaluation was carried out using 2007-2009 land surface forcing data from the North American Land Data Assimilation System (NLDAS) and crop maps derived from remotely sensed data of NASA's Moderate Resolution Imaging Spectroradiometer (MODIS). We compared the canopy parameters produced by the phenology model with normalized difference vegetation index (NDVI) data derived from the MODIS nadir bi-directional reflectance distribution function (BRDF) adjusted reflectance (NBAR) product. The expectations of the EDPM performance in prognostic mode were met, producing determination coefficient (r2) of 0.8 +/-.0.15. Model estimates of NDVI yielded root mean square error (RMSE) of 0.1 +/-.0.035 for the entire study area. Retrospective correction of canopy dynamics with MODIS NDVI brought the errors down to just below 10% of observed data range. The ET estimates produced by the coupled scheme were compared with ones from the MODIS land product suite. The expected r2=0.7 +/-.15 and RMSE = 11.2 +/-.4 mm per 8 days were met and even exceeded by the coupling scheme0 functioning in both prognostic and retrospective modes. Minor setbacks of the EDPM and VegET performance (r2 about 0.5 and additional 30 % of RMSR) were found on the peripheries of the study area and attributed to the insufficient EDPM training and to spatially varying accuracy of crop maps. Overall the experiment provided sufficient evidence of soundness and robustness of the EDPM and VegET coupling scheme, assuring its potential for spatially explicit applications.

Kovalskyy, V.↗

Crater Flux Transfer Events: Highroad to the X Line?

We examine Cluster observations of a so-called magnetosphere crater FTE, employing data from five instruments (FGM, CIS, EDI, EFW, and WHISPER), some at the highest resolution. The aim of doing this is to deepen our understanding of the reconnection nature of these events by applying recent advances in the theory of collisionless reconnection and in detailed observational work. Our data support the hypothesis of a stratified structure with regions which we show to be spatial structures. We support the bulge-like topology of the core region (R3) made up of plasma jetting transverse to reconnected field lines. We document encounters with a magnetic separatrix as a thin layer embedded in the region (R2) just outside the bulge, where the speed of the protons flowing approximately parallel to the field maximizes: (1) short (fraction of a sec) bursts of enhanced electric field strengths (up to approximately 30 mV/m) and (2) electrons flowing against the field toward the X line at approximately the same time as the bursts of intense electric fields. R2 also contains a density decrease concomitant with an enhanced magnetic field strength. At its interface with the core region, R3, electric field activity ceases abruptly. The accelerated plasma flow profile has a catenary shape consisting of beams parallel to the field in R2 close to the R2/R3 boundary and slower jets moving across the magnetic field within the bulge region. We detail commonalities our observations of crater FTEs have with reconnection structures in other scenarios. We suggest that in view of these properties and their frequency of occurrence, crater FTEs are ideal places to study processes at the separatrices, key regions in magnetic reconnection. This is a good preparation for the MMS mission.

Farrugia, C. J.↗

Measuring Total Column Water Vapor by Pointing an Infrared Thermometer at the Sky

A 2-year study affirms that the temperature (Tz) indicated by an inexpensive ($20 to $60) IR thermometer pointed at the cloud-free zenith sky provides an approximate indication of the total column water vapor (precipitable water or PW). PW was measured by a MICROTOPS II sun photometer. The coefficient of correlation (r2) of the PW and Tz was 0.90, and the rms difference was 3.2 mm. A comparison of the Tz data with the PW provided by a GPS site 31 km NNE yielded an r2 of 0.79, and an rms difference of 5.8 mm. An expanded study compared Tz from eight IR thermometers with PW at various times during the day and night from 17 May to 18 October 2010, mainly at the Texas site and 10 days at Hawaii's Mauna Loa Observatory (MLO). The best results of this comparison were provided by two IR thermometers models that yielded an r2 of 0.96 and an rms difference with the PW of 2.7 mm. The results of both the ongoing 2-year study and the 5-month instrument comparison show that IR thermometers can measure PW with an accuracy (rms difference/mean PW) approaching 10%, the accuracy typically ascribed to sun photometers.

Mims, Forrest M., III↗

Role of Temperature, Humidity and Rainfall on Influenza Transmission in Guatemala, El Salvador and Panama

Worldwide, seasonal influenza causes about 500,000 deaths and 5 million severe illnesses per year. The environmental drivers of influenza transmission are poorly understood especially in the tropics. We aimed to identify meteorological factors for influenza transmission in tropical Central America. We gathered laboratory-confirmed influenza case-counts by week from Guatemala City, San Salvador Department (El Salvador) and Panama Province from 2006 to 2010. The average total cases per year were: 390 (Guatemala), 99 (San Salvador) and 129 (Panama). Meteorological factors including daily air temperature, rainfall, relative and absolute humidity (RH, AH) were obtained from ground stations, NASA satellites and land models. For these factors, we computed weekly averages and their deviation from the 5-yr means. We assessed the relationship between the number of influenza case-counts and the meteorological factors, including effects lagged by 1 to 4 weeks, using Poisson regression for each site. Our results showed influenza in San Salvador would increase by 1 case within a week of every 1 day with RH>75% (Relative Risk (RR)= 1.32, p=.001) and every 1C increase in minimum temperature (RR=1.29, p=.007) but it would decrease by 1 case for every 1mm-above mean weekly rainfall (RR=0.93,p<.001) (model pseudo-R2=0.55). Within 2 weeks, influenza in Panama was increased by 1 case for every 1% increase in RH (RR=1.04, p=.003), and it was increased by 2 cases for every 1C increase of minimum temperature (RR=2.01, p<.001) (model pseudo-R2=0.4). Influenza counts in Guatemala had 1 case increase for every 1C increase in minimum temperature in the previous week (RR=1.21, p<.001), and for every 1mm/day-above normal increase of rainfall rate (RR=1.03, p=.03) (model pseudo-R2=0.54). Our findings that cases increase with temperature and humidity differ from some temperate-zone studies. But they indicate that climate parameters such as humidity and temperature could be predictive of influenza activity and should be incorporated into country-specific influenza transmission models

Soebiyanto, Radina P.↗