Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Characterization of Spent Purolite A530E Resin with Implications for Long-Term Radioactive Contaminant Removal

Direct removal of pertechnetate anion (TcO4-) from the subsurface contaminated plumes at legacy nuclear weapons production sites, is effective remediation strategy to prevent their spread to adjacent aquifers but is also challenging because TcO4- is a trace component of the contaminated groundwater typically containing large access of other anionic constituents, such nitrate, sulfate, chloride and others. It can be achieved through ion exchange treatment using Purolite A530E resin which to date however has only been evaluated under laboratory conditions and many questions regarding its long-term operational performance remain. To address this need, here we report comprehensive characterization of the spent Purolite A530E resin which processed over 5.38x109 L of contaminated groundwater and successfully removed about 3.78 Ci of Tc-99 during four years of operation at the 200 West Pump & Treat facility at the US DOE Hanford site. This Tc-99 loading constitutes however only about 0.034% of the theoretical capacity of the resin which retained significant amounts of sulfate. Among other radioactive contaminants, small quantities of U-238, Co-60, and I-129 were retained by the resin. The total loading of iodine (combined 1-127 and I-129) on the spent resin exceeded that of Tc-99. To elucidate the mechanism of iodine retention, ion exchange behavior of iodide and iodate was investigated. Purolite A530E resin exhibited highly efficient uptake of iodide and only moderate affinity for iodate in accord with their Gibbs energy of hydration. Sorption isotherms for both anions obeyed Freundlich model.

Levitskaia, Tatiana G.↗

Ultra-low radioactivity Kapton and copper-Kapton laminates

Polyimide-based materials, like Kapton, are widely used in flexible cables and circuitry due to their unique electrical and mechanical characteristics. This study is aimed at investigating the radiopurity of Kapton for use in ultralow background, rare-event physics applications by measuring the 238U, 232Th, and natK levels using inductively coupled plasma mass spectrometry. Commercial-off-the-shelf Kapton varieties, mea- sured at approximately 950 and 120 pg/g 238U and 232Th (1.2×104 and 490 µBq/kg), respectively, can be a significant background source for many current and next-generation ultralow background detectors. This study has found that the dominant contamination is due to the use of dicalcium phosphate (DCP), a nonessential slip additive added during manufacturing. Alternative Kapton materials were obtained that did not contain DCP and were determined to be significantly more radiopure than the commercially- available options with 12 and 19 pg/g 238U and 232Th (150 and 77 µBq/kg), respectively. The lowest radioactivity version produced (Kapton ELJ, which contains an adhesive) was found to contain single digit pg/g levels of 238U and 232Th, two-to-three orders of magnitude cleaner than commercial-off-the- shelf options. Moreover, copper-clad polyimide laminates employing Kapton ELJ as the insulator were obtained and measured and showed to be very radiopure at 8.6 and 22 pg/g 238U and 232Th (110 and 89 µBq/kg), respectively.

Arnquist, Isaac J.↗

Charge Breeding of Radioactive Isotopes at the CARIBU Facility

An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne National Laboratory as part of the californium rare ion breeder upgrade. For the past year, the EBIS-CB has been undergoing commissioning as part of the ATLAS accelerator complex. It has delivered both stable and radioactive beams with A/Q < 6, breeding times < 30 ms, low background contamination, and charge breeding efficiencies > 18% into a single charge state. The operation of this device, challenges during the commissioning phase, and future improvements will be discussed. Published by AIP Publishing.

Vondrasek, Richard↗

Results From the First Use of Low Radioactivity Argon in a Dark Matter Search

Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar39 at a level reduced by a factor (1.4±0.2)×103 relative to atmospheric argon. We report a background-free null result from (2616±43) kg d of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0×10-44 cm2 (8.6×10-44 cm2, 8.0×10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2, 10 TeV/c2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predictive modeling of crystal accumulation in high-level waste glass melters processing radioactive waste

The effectiveness of HLW vitrification is limited by precipitation/accumulation of spinel crystals [(Fe, Ni, Mn, Zn)(Fe, Cr)2O4] in the glass discharge riser of Joule-heated ceramic melters during idling. These crystals do not affect glass durability; however, if accumulated in thick layer, they can clog the melter and prevent discharge of molten glass into canisters. To address this problem, an empirical model was developed that can predict thicknesses of accumulated layers as a function of glass composition. This model predicts well the accumulation of single crystals and/or small-scale agglomerates, but, excessive agglomeration observed in high-Ni-Fe glass resulted in an under-prediction of accumulated layers, which gradually worsen over time as an increased number of agglomerates formed. Accumulation rate of ~53.8 ± 3.7 µm/h determined for this glass will result in ~26 mm thick layer in 20 days of melter idling.

Crystal accumulation↗

Nuclear properties for astrophysical and radioactive-ion-beam applications (II)

We tabulate the ground-state odd-proton and odd-neutron spins and parities, proton and neutron pairing gaps, one- and two-neutron separation energies, quantities related to β-delayed one- and two-neutron emission probabilities, average energy and average number of emitted neutrons, β-decay energy release and half-life with respect to Gamow–Teller decay with a phenomenological treatment of first-forbidden decays, one- and two-proton separation energies, and α-decay energy release and half-life for 9318 nuclei ranging from {sup 16}O to {sup 339}136 and extending from the proton drip line to the neutron drip line. This paper is a new and improved version of Atomic Data And Nuclear Data Tables [66 131 (1997)]. The starting point of our present work is the new study (FRDM(2012)) of nuclear ground-state masses and deformations based on the finite-range droplet model and folded-Yukawa single-particle potential published in a previous issue of Atomic Data And Nuclear Data Tables [109–110, 1 (2016)]. The β-delayed neutron-emission probabilities and Gamow–Teller β-decay rates are obtained from a quasi-particle random-phase approximation with single-particle levels and wave functions at the calculated nuclear ground-state shapes as input quantities. A development since 1997 is we now use a Hauser–Feshbach approach to account for (n, γ) competition and treat first-forbidden decay in a phenomenological approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of radioactivity-induced backgrounds in EXO-200

The search for neutrinoless double-beta decay ( 0 ν β β ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0 ν β β signal. We report on studies of various β and γ backgrounds in the liquid-xenon-based EXO- 200 0 ν β β experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗