Search NASA⌕ Search

SEARCH · Search NASA

Results for “RAMAN SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ab initio infrared and Raman spectra

It is pointed out that with increased computer power and improved computational techniques, such as the gradients developed in recent years, it is becoming practical to compute spectra ab initio, from the fundamental constants of nature, for systems of increasing complexity. The present investigation has the objective to explore several possible ab initio approaches to spectra, giving particular attention to infrared and nonresonance Raman. Two approaches are discussed. The sequential approach, in which first the electronic part and then later the nuclear part of the Born-Oppenheimer approximation is solved, is appropriate for small systems. The simultaneous approach, in which the electronic and nuclear parts are solved at the same time, is more appropriate for many-atom systems. A review of the newer quantum gradient techniques is provided, and the infrared and Raman spectral band contours for the water molecule are computed.

Fredkin, D. R.↗

Measurement of Raman spectra of H2O and SO4(-) in seawater

A study of applying laser Raman spectroscopy to remote sensing of the sulfate ion in sea water is in progress. The SO4 Raman spectrum has been obtained from true sea water samples in the laboratory using a CW laser Raman spectrometric system. Radiometric calculations indicate the feasibility of obtaining usable SO4 Raman signals in a field experiment. One of serious difficulties expected in the field experiment would be from fluorescence of phytoplankton and organics.

Houghton, W. M.↗

Raman spectra of adsorbed layers on space shuttle and AOTV thermal protection system surface

Surfaces of interest to space vehicle heat shield design were struck by a 2 W argon ion laser line while subjected to supersonic arc jet flow conditions. Emission spectra were taken at 90 deg to the angle of laser incidence on the test object. Results showed possible weak Raman shifts which could not be directly tied to any particular parameter such as surface temperature or gas composition. The investigation must be considered exploratory in terms of findings. Many undesirable effects were found and corrected as the project progressed. For instance, initial spectra settings led to ghosts which were eliminated by closing the intermediate of filter slit of the Spex from 8 to 3 mm. Further, under certain conditions, plasma lines from the laser were observed. Several materials were also investigated at room temperature for Raman shifts. Results showed Raman shifts for RCC and TEOS coated materials. The HRSI materials showed only weak Raman shifts, however, substantial efforts were made in studying these materials. Baseline materials showed the technique to be sound. The original goal was to find a Raman shift for the High-temperature Reusable Surface Insulation (HRSI) Reaction Cured borosilicate Glass (RCG) coated material and tie the amplitude of this peak to Arc jet conditions. Weak Raman shifts may be present, however, time limitations prevented confirmation.

Willey, Ronald J.↗

Algorithmic Classification of Raman Spectra Biosignatures: Improving Life Detection Confidence

“Agnostic” biosignatures – indicators of life (or the absence of life), independent of a particular biochemistry – are increasingly considered a high standard for life detection. The Ladder of Life Detection (2018) called for investigating how combinations of independent and different potential biosignatures affect confidence. To address this gap, statistical classification of elemental abundances, isotopic fractionation, and reflectance spectroscopy (VNIR) has been implemented. Raman spectroscopy, highly desirable due to its wide availability, has the potential to improve this predictive power. This work implemented biosignature classification algorithms on Raman data alone, in preparation for combination with the other data types. Raman spectroscopy data was collected from published databases and papers as part of a manually curated dataset of “indicative” and “non-indicative of life” samples. These currently include 61 non-indicative samples (meteorites, magnetite); 3 indicative living samples (bacteria); 20 indicative non-living samples (chalk, bone); and 12 indicative mixed (with non-indicative material) samples (soil, microbial mats). Laboratory work is ongoing to characterize additional samples, particularly a greater breadth of mixed systems. Spectra were interpolated, filtered with the Savitzsky-Golay filter, and de-noised. For a preliminary examination, agnostic features were manually extracted including mean intensity, number of peaks, and mean peak width. Different peak prominences and filtering polynomials were used to refine features. Classification algorithms were implemented: k-nearest neighbors (KNN), logistic regression (LR), linear support vector machines (SVM), random forest (RF), Gaussian naïve bayes (GNB). Lastly, Monte Carlo simulations on 1,000 50%-train-test-splits were used to validate classification performance and feature significance. The preliminary feature set achieved its highest AUC of 0.52 with LR, with no strongly discriminatory features. Work to improve feature extraction, such as through deep learning with back propagation, is planned. In future work, the Raman data will be combined with the other data types, and potentially new data types such as enantiomeric excess. This project was partially supported through the NASA Ames Project EXcellence (APEX) incubator program.

Astrobiology↗

Line Coupling Effects in the Isotropic Raman Spectra of N2: A Quantum Calculation at Room Temperature

We present quantum calculations of the relaxation matrix for the Q branch of N2 at room temperature using a recently proposed N2-N2 rigid rotor potential. Close coupling calculations were complemented by coupled states studies at high energies and provide about 10200 two-body state-to state cross sections from which the needed one-body cross-sections may be obtained. For such temperatures, convergence has to be thoroughly analyzed since such conditions are close to the limit of current computational feasibility. This has been done using complementary calculations based on the energy corrected sudden formalism. Agreement of these quantum predictions with experimental data is good, but the main goal of this work is to provide a benchmark relaxation matrix for testing more approximate methods which remain of a great utility for complex molecular systems at room (and higher) temperatures.

nitrogen↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing mineralogy, carbon composition/speciation, and crystal orientation all within a petrographic context. Adequately examining the heterogeneous composition of a meteorite, while maintaining low laser powers needed to prevent damage to meteorite mineralogy and organics, often requires the collection of large Raman images with long collection times on the timescale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. This decrease in frequency precision can compromise the analysis of geological markers that can provide important information on a meteorite sample. We examine, in detail, the change in bandwidth and frequency of the Raman bands and Hg-Ar emission lines in our Raman images as a function of time and laboratory temperature. To overcome the drift in calibration, we utilize a commercial WITec Raman instrument with an internal Hg-Ar calibration lamp to individually calibrate each spectrum in the Raman image. Our instrument, known as “Ratatoskr”, uses a beam splitter in place of the customary mirror to facilitate collection of Hg-Ar calibration lines concurrent with Raman spectra. We show that using the internal calibration we can improve the frequency precision for the spectra in our Raman images from ~±0.15 cm(exp -1) to ~±0.05 cm(exp -1) for Raman spectra collected over multiple days. This is important as it improves measurements of mineral chemistry, latent strain, and other features that are dependent upon accurate peak position determination. We also examine the spectral signal-to-noise ratio needed to minimize the frequency error when fitting bands to Gaussian/Lorentzian profiles. We then use our results to suggest a general method for calibrating the frequency of Raman spectra in large Raman images.

Jakubek, Ryan S.↗

Measurement and Simulation of Spontaneous Raman Scattering Spectra in High-Pressure, Fuel-Rich H2-Air Flames

Rotational vibrational spontaneous Raman spectra (SRS) of H2, N2, and H2O have been measured in H2-air flames at pressures up to 30 atm as a first stem towards establishing a comprehensive Raman spectral database for temperatures and species in high-pressure combustion. A newly developed high-pressure burner facility provides steady, reproducible flames with a high degree of flow precision. We have obtained an initial set of measurements that indicate the spectra are of sufficient quality in terms of spectral resolution, wavelength coverage, and signal-to-noise ratio for use in future reference standards. The fully resolved Stokes and anti-Stokes shifted SRS spectra were collected in the visible wavelength range (400-700 nm) using pulse-stretched 532 nm excitation and a non-intensified CCD spectrograph with a high-speed shutter. Reasonable temperatures were determined via the intensity distribution of rotational H2 lines at stoichiometry and fuel-rich conditions. Theoretical Raman spectra of H2 were computed using a semi-classical harmonic-oscillator model with recent pressure broadening data and were compared with experimental results. The data and simulation indicated that high-J rotational lines of H2 might interfere with the N2 vibrational Q-branch lines, and this could lead to errors in N2-Raman thermometry based on the line-fitting method. From a comparison of N2 Q-branch spectra in lean H2 low-pressure (1.2 atm) and high-pressure (30 atm) flames, we found no significant line-narrowing or -broadening effects at the current spectrometer resolution of 0.04 nm.

Kojima, Jun↗

Coherent anti-Stokes Raman spectroscopy - Spectra of water vapor in flames

The results of experimental measurements of the coherent anti-Stokes Raman spectra of water vapor in flames are reported. A pulsed, frequency-doubled neodymium laser was used to supply the pump beam and to pump a dye laser to provide a broadband Stokes beam at 6600 A. Spectra were obtained in the postflame region of a premixed methane-air flame in the Raman frequency shift region of the symmetric stretch mode (3651.7 kaysers) at an approximate temperature of 1675 K. A theoretical calculation of the coherent anti-Stokes Raman spectrum of water vapor at this temperature was made, taking into account only isotropic Q-branch transitions, and using the energy level data of Floud et al. (1976). The theoretical prediction is shown essentially to reproduce all qualitative features of the experimental spectrum, and to exhibit a strong temperature dependence.

Hall, R. J.↗