Search NASA⌕ Search

SEARCH · Search NASA

Results for “RCCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Semi-Annual Report for Modular Integrated Gas High Temperature Reactor Development during Performance Period April 2022 - September 2022

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multidisciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This second semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY22. As a part of the RCCS design task, a scoping calculation in estimating HVAC capability for the HC-HTGR reactor building was performed. A water panel modeling study was first performed with the test case, which confirms the capability of the RELAP5-3D modeling approach to explore various design options of the HC-HTGR RCCS under consideration. Then, a reference RELAP5-3D model for the unit geometry of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate the performances of a single-phase natural circulation and panel conduction in various operating conditions. For the primary coolant system analysis task, preliminary thermal hydraulic analysis of the HC-HTGR core design was performed with a high resolution 1D fluid-3D solid coupled model using the System Analysis Module (SAM) to assess the assembly coolant channel and bypass flow mass flow rate distribution. Some preliminary work on the development of a full core reduced order model was discussed following the assembly level model to predict the core wide coolant flow distribution and to model certain operational and accidental transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MODELING THE AMBIENT CONDITION EFFECTS OF AN AIR-COOLED NATURAL CIRCULATION SYSTEM

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). One such variant, air-cooled RCCS, uses natural convection to drive the flow of air from outside the reactor building to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a half-scale model of the primary features of one conceptual air-cooled RCCS design. The facility was constructed to carry out highly instrumented experiments to study the performance of the RCCS concept for reactor decay heat removal that relies on natural convection cooling. Parallel modeling and simulation efforts were performed to support the design, operation, and analysis of the natural convection system. Throughout the testing program, strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under the same test procedures. Thus, significant analysis efforts were devoted to gaining a better understanding of these influences and the subsequent response of the NSTF to ambient conditions. It was determined that air humidity had negligible impacts on NSTF system performance and therefore did not warrant consideration in the models. However, temperature differences between the building exterior and interior air, along with the outside wind speed, were shown to be dominant factors. Combining the stack and wind effects together, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions. Some coefficients in the model were obtained based on best fitting the experimental data. The predictive capability of the empirical model was demonstrated by applying it to the new set of experimental data. The empirical model was also implemented in the computational models of the NSTF using both RELAP5-3D and STARCCM+ codes. Accounting for the effects of ambient conditions, simulations from both codes predicted the natural circulation flow rates very well.

Hu, Rui↗

Improved natural convection heat transfer correlations for reactor cavity cooling systems of high-temperature gas-cooled reactors: From computational fluid dynamics to Pronghorn

The Reactor Cavity Cooling System (RCCS) is a common reactor safety system in High Temperature Gas Cooled Reactors (HTGR) that removes heat from the Reactor Pressure Vessel (RPV) by radiation ($\sim 80\%$) and natural convection ($\sim 20\%$). For simulation of accident scenarios of HTGRs, intermediate fidelity and system codes models must be employed for limiting the models' execution time. While accurate quantification of the radiative heat transfer is available in these models, quantification of natural convection must rely on correlations of questionable accuracy for the Nusselt number. Commonly used correlations are based in experiments performed at low Rayleigh numbers and/or using isothermal walls in simplified geometries. Here, this work improves on the accuracy of natural convection heat transfer correlations in support for HTGR designs. These correlations include both local and average Nusselt numbers as a function of the global Rayleigh number, the local Rayleigh number, and the temperature profile at the hot wall of the RCCS. In the absence of dedicated experiments and the difficulty of performing high-fidelity simulations at realistic Rayleigh numbers, the data to fit the correlations are generated with Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier-Stokes (RANS) models. First, a careful selection of the RANS turbulence model is performed by comparing the results obtained with different RANS turbulence models against high fidelity simulations of natural convection at $Ra \ 1 \times 10^{11}$ in a rectangular cavity. Next, the selected model is used to perform simulations of an HTGR cavity at different high Rayleigh numbers $\in [6.1 \times 10^{11},2.9 \times 10^{13}]$ to encompass several HTGR designs, assuming an isothermal RPV wall. The results obtained are used to fit a correlation for the average and space-varying Nusselt number as a function of the global and local Rayleigh numbers via a sparsity-promoting least-squares method. The selected RANS model is then used to perform simulations of a PBMR 400 HTGR cavity with the temperature profiles at the RPV wall obtained during a PLOFC transient. We use the results obtained to fit a temperature-dependent correction to the space-varying Nusselt number with the sparsity-promoting least-squares method. The results obtained in this work, enable system-level codes, such as Pronghorn, to perform higher-fidelity simulations of the heat exchange process in the RCCS while still maintaining a low computational cost.

42 ENGINEERING↗

HIV drug resistance during antiretroviral therapy scale-up in Uganda, 2012–19: a population-based, longitudinal study

Background With scale-up of antiretroviral therapy (ART) in sub-Saharan Africa, increasing pretreatment HIV drug resistance has been reported; however, the broader effect of ART expansion on population-level resistance patterns remains insufficiently quantified. We aimed to estimate the longitudinal prevalence of drug resistance and resistance-conferring mutations. Methods This study used data collected as part of the Rakai Community Cohort Study (RCCS), an open population-based census and cohort study conducted in southern Uganda. At each survey round, residents aged 15–49 years are invited to participate and receive a structured questionnaire that obtains sociodemographic, behavioural, and health information, including self-reported past and current ART use. Voluntary HIV testing is conducted using a rapid test algorithm and a venous blood sample. People with HIV provide samples for viral load quantification and deep sequencing. We analysed RCCS survey, HIV viral load, and deep sequencing (which was used to predict resistance) data from five survey rounds. The key outcomes were the population prevalence of viraemic people with HIV with non-nucleoside reverse transcriptase inhibitor (NNRTI), nucleoside reverse transcriptase inhibitor (NRTI), protease inhibitor, or multiclass resistance among all participants (regardless of HIV serostatus) in the 2015 and 2017 surveys. Prevalence of class-specific resistance and resistance-conferring substitutions were estimated using robust log-Poisson regression. Findings Between Aug 10, 2011, and Nov 4, 2020, there were 43 361 participants in the RCCS and 7923 (18·27%) people with HIV. Over five survey rounds, 93 622 participant visits occurred, among which 17 460 (18·65%) were from people with HIV. Over the analysis period, the median age of study participants remained similar (28 years [22–35] in 2012 and 29 years [21–38] in 2019). Sufficient data were available to reliably genotype 4072 (90·03%) of 4523 participant visits from 3407 people with HIV for at least one drug. Overall population prevalence of resistance contributed by viraemic pretreatment people with HIV decreased between 2012 and 2017 from 0·56% (95% CI 0·42–0·75) to 0·25% (0·18–0·33) for NNRTI and from 0·24% (0·15–0·37) to 0·05% (0·02–0·10) for NRTI (prevalence ratio 0·44 [0·29–0·68] for NNRTI and 0·21 [0·09–0·47] for NRTI). Between 2012 and 2017, NNRTI resistance among viraemic pretreatment people with HIV increased from 4·86% (3·69–6·42) to 9·61% (7·27–12·7; prevalence ratio 1·98 [1·34–2·91]). The prevalence of NNRTI and NRTI resistance was substantially higher among viraemic treatment-experienced people with HIV (51·49% [46·24–57·34] for NNRTI and 36·46% [30·06–44·22] for NRTI in 2017) than among pretreatment people with HIV. NNRTI and NRTI resistance was predominantly attributable to rtK103N and rtM184V. inT97A was observed at a similar prevalence among viraemic treatment-experienced (9·96% [6·41–15·48]) and viraemic pretreatment (10·56% [8·01–13·93]) people with HIV; no major dolutegravir resistance mutations were observed. Interpretation Despite rising NNRTI resistance among pretreatment people with HIV, overall population prevalence of pretreatment HIV drug-resistant viraemia decreased due to increasing ART uptake and viral suppression. This finding underscores the crucial role of achieving and maintaining high ART coverage in reducing transmission of drug-resistant HIV. The high prevalence of mutations conferring resistance to components of first-line ART regimens among viraemic people with HIV is potentially concerning. Funding National Institutes of Health, Johns Hopkins University Center for AIDS Research, Bill & Melinda Gates Foundation, and the US Centers for Disease Control and Prevention.

59 BASIC BIOLOGICAL SCIENCES↗

SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry

This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Proper cooling-water chemistry is essential to preserving the DTL and CCL structures during their design lifetime. Appropriate water chemistry will protect cooling-water passages and brazed joints of the structure from erosion, corrosion, and fouling. The RCCS/QMCS DIW chemistry is managed by sidestreams built into the cooling loops; chemicals are not used. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended. During the evaluation period, the pH, dissolved oxygen, and water resistivity of the cooling water were observed. The data were collected by instruments mounted on mobile chemistry carts, which were moved from one RCCS/QMCS DIW skid to another. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time. It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similar regime, with a pH of about 7.5 (slightly alkaline), low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH. An RCCS/QMCS chemistry guidance document published in May 2017 describes and standardizes the methods and practices for water chemical treatment for the SNS RCCS and QMCS. It is very difficult to accurately measure the pH, dissolved oxygen, and water resistivity in highly pure water. Therefore, a regularly scheduled calibration program will be established for the instruments. Recommendations are given at the end of the report on how to run the RCCS/QMCS cooling water chemistry. Chemical analysis of the material trapped by the polishing loop prefilters is conducted twice a year. The analysis and its benefits are described in Chapter 9.

42 ENGINEERING↗

Final Project Report on Computational Modeling and Analysis of Air-Based NSTF

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). The air-cooled RCCS uses natural convection to drive the flow of air from outside the power plant to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a ½ - scale model of the primary features of one conceptual air-cooled RCCS design. The NSTF program performs ex-vessel, passive heat removal experiments in support of Department of Energy Office of Nuclear Energy’s Advanced Reactor Technology (ART) program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Study of the Effect of Graphite Dispersion on the Heat Transfer Phenomena in a Reactor Cavity Cooling System

An experimental activity was performed to observe and study the effects of graphite dispersion and deposition on thermal-hydraulic phenomena in a reactor cavity cooling system (RCCS). The small-scale RCCS experimental facility (16.5 x 16.5 x 30.4 cm) used for this activity represents half of the reactor cavity with an electrically heated vessel. Water flowing through five vertical pipes removes the heat produced in the vessel and releases it into the environment by mixing with cold water in a large tank. The particle image velocimetry technique was used to study the velocity field of the air inside the cavity. A set of 52 thermocouples was installed in the facility to monitor the temperature profiles of the vessel, pipe walls, and air. Ten grams of a fine graphite powder (average particle size 2 m) was injected into the cavity through a spraying nozzle placed at the bottom of the vessel. The temperatures and air velocity field were recorded and compared with the measurements obtained before the graphite dispersion, showing a decrease of the temperature surfaces that was related to an increase in their emissivity. The results contribute to the understanding of RCCS capability in an accident scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Development of a Demonstration Passive System Reliability Assessment

In this paper, the details of the development of a demonstration problem to assess the reliability of a passive safety system are presented. An advanced small modular reactor (advSMR) design, which is a pool-type sodium fast reactor (SFR) coupled with a passive reactor cavity cooling system (RCCS) is described. The RELAP5-3D models of the advSMR and RCCS that will be used to simulate a long-term station blackout (SBO) accident scenario are presented. Proposed benchmarking techniques for both the reactor and the RCCS are discussed, which includes utilization of experimental results from the Natural convection Shutdown heat removal Test Facility (NSTF) at the Argonne National Laboratory. Details of how mechanistic methods, specifically the Reliability Method for Passive Systems (RMPS) approach, will be utilized to determine passive system reliability are presented. The results of this mechanistic analysis will ultimately be compared to results from dynamic methods in future work. This work is part of an ongoing project at Argonne to demonstrate methodologies for assessing passive system reliability.

Bucknor, Matthew↗

Comparisons of RELAP5-3D Analyses to Experimental Data from the Natural Convection Shutdown Heat Removal Test Facility

The Reactor Cavity Cooling System (RCCS) is an important passive safety system being incorporated into the overall safety strategy for high temperature advanced reactor concepts such as the High Temperature Gas- Cooled Reactors (HTGR). The Natural Convection Shutdown Heat Removal Test Facility (NSTF) at Argonne National Laboratory (Argonne) reflects a 1/2-scale model of the primary features of one conceptual air-cooled RCCS design. The project conducts ex-vessel, passive heat removal experiments in support of Department of Energy Office of Nuclear Energy’s Advanced Reactor Technology (ART) program, while also generating data for code validation purposes. While experiments are being conducted at the NSTF to evaluate the feasibility of the passive RCCS, parallel modeling and simulation efforts are ongoing to support the design, fabrication, and operation of these natural convection systems. Both system-level and high fidelity computational fluid dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. This paper provides a summary of the RELAP5-3D NSTF model development efforts and provides comparisons between simulation results and experimental data from the NSTF. Overall, the simulation results compared favorably to the experimental data, however, further analyses need to be conducted to investigate any identified differences.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OSU High Temperature Test Facility Design Technical Report, Revision 2

The HTTF is an integral test facility, which has been designed to model the behavior of interest for a MHTGR during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. A scaling report has been developed and provides further detail into the scaling analysis for the HTTF. The maximum core power for the facility is approximately 2.2MW. The core region will be of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. The HTTF consists of the following systems: A primary system consisting of the reactor pressure vessel (RPV), the circulator, cross over ducts and primary piping. The core internals sit inside the RPV and provide support for the core and core heaters. The purpose of the primary system is to maintain the pressure boundary, remove heat from the core through convection, conduction and radiation, and provide heat to the core through a series of electrical heaters. A secondary system consisting of a steam generator, feed water system and main steam system. The purpose of the secondary system is to remove heat from the primary system during heat up, cool down and normal operations. A reactor cavity simulation system consisting of a cavity tank, gas conditioning system and a series of break valves. Note that the prototypical MHTGR sits inside of a cavity. In the event of a break the helium will blowdown into this cavity. At the HTTF, the cavity is modeled as a separate tank, the reactor cavity simulation tank (RCST) and is connected to the RPV through break valves—hot-leg, cold-leg, upper break, and lower break. A reactor cavity cooling system (RCCS) consisting of a series of water cooled panels and the water supply system for these panels. The HTTF RCCS is not a scaled prototypical RCCS system for the MHTGR. It is provided in the HTTF in order to set the boundary condition for radiation heat transfer from the RPV. Various auxiliary systems including the city water supply system, the electrical power supply and distribution system, the chilled water system and the instrument air system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

THE SNS RESONANCE CONTROL COOLING SYSTEM CONTROL VALVE UPGRADE PERFORMANCE

The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

43 PARTICLE ACCELERATORS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary Report of the FY24 DOE Contributions to the GIF VHTR CMVB

The Generation-IV Forum (GIF) Very-High-Temperature Reactor-Computational Methods Validation and Benchmark (VHTR-CMVB) initiative, involving organizations from Korea Atomic Energy Research Institute (KAERI) (South Korea), Institute of Nuclear and New Energy Technology of Tsinghua University (INET) (China), U.S. Department of Energy (DOE) (U.S.), Joint Research Centre (JRC) (Europe), and Japan Atomic Energy Agency (JAEA) (Japan), is dedicated to the verification and validation of tools for High-Temperature Gas-Cooled Reactors (HTGRs) analysis, using data shared by Computational Methods Validation and Benchmark (CMVB) signatories. For FY24, the US DOE CMVB has committed to several critical activities. Under WP1, led by the US, the integration of the High Temperature Gas Cooled Reactor - Pebble-Bed Module (HTR-PM) Phenomena Identification and Ranking Table (PIRT) into the comparative PIRT is progressing, with a new draft of the comparison tables issued earlier this year and currently being utilized by INET for their contribution. Neutronic validation efforts under WP3 include the preparation of the burnup analysis benchmark, preliminary calculations, and the development of reference models and results. In WP2, a validation exercise for hot gas mixing in the lower plenum of HTR-PM is in progress, using experimental data from INET (China) to validate modeling approaches. A model of the experimental facility has been developed using StarCCM+, with initial calculations slated for presentation at the GIF CMVB meeting this fall. Another WP2 activity focuses on validating numerical models for air-cooled Reactor Cavity Cooling System (RCCS) with experimental data from the Wisconsin Madison RCCS facility. A high-fidelity model, developed using NEK-RS, is currently being validated with available data from a low power forced convection test. These efforts are aimed at enhancing and confirming the accuracy of HTGR analysis tools, ensuring their alignment with experimental data and regulatory requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Magnetic resonance imaging findings of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion in adults: a pilot study

Purpose: The purpose of the study was to retrospectively analyze MRI findings of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion (Xp11.2/TFE RCC) in adults. Methods: Sixteen patients with Xp11.2/TFE RCC were reviewed retrospectively. The clinical characteristics and imaging features were assessed and then compared between metastatic and non-metastatic subgroups. Results: The mean age at diagnosis was 47.4 (20–76) years. Seven (44 %) patients were men, and nine (56 %) patients were women. The lesions predominantly exhibited an endophytic distribution (n = 14, 88 %) with a capsule (n = 16, 100 %), accompanied by solid and cystic patterns (n = 12, 75%) and hemorrhage (n = 11, 69 %). The tumors prevalently appeared hyper- to isointense on T1WI (n = 14, 88 %), hypointense on T2WI (n = 13, 81 %), and hyperintense on DWI (n = 16, 100 %) with a lower ADC (P < 0.001) than that of the surrounding tissue. The tumors were less enhanced than the normal renal cortex in all phases with a prolonged enhancement pattern (P ≤ 0.001). In addition, six patients (38 %) developed recurrence or metastases. The RCCs with metastases showed an irregular shape (P = 0.013), an incomplete capsule (P = 0.018), heterogeneous solid-cystic patterns (P = 0.034), and hemorrhage (P = 0.037) than non-metastatic subgroups. Conclusions: MRI provides valuable information for the diagnosis of adult Xp11.2/TFE RCCs. Features including irregular shape, incomplete capsule, mixed solid-cystic pattern, and hemorrhage may indicate the occurrence of recurrence or metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of rapid kV-switching dual energy CT in renal tumor characterization

Purpose: To investigate whether iodine content can discriminate between benign or malignant renal tumors, malign tumor subtypes, low-grade and high-grade tumors on rapid kv-switching dual-energy CT (rsDECT). Methods: This prospective study enrolled 95 patients with renal tumors who underwent rsDECT for tumor characterization between 2016 and 2018. Attenuation on true and virtual unenhanced images, absolute enhancement and enhancement ratio and iodine content of each lesion on nephrographic phase iodine density images were measured. Histopathological diagnosis was obtained following either surgery or core biopsy. Results: Eighty-five tumors were renal cell carcinoma (RCC) (56 clear cell, 20 papillary, 9 chromophobe) and 10 were benign (6 angiomyolipoma,4 oncocytoma). 46 tumors were low-grade and 23 high-grade. There was significant difference between iodine content of clear cell and non-clear cell (papillary + chromophobe) RCC (p < 0.001). However, no significant iodine content differences were found between papillary and chromophobe RCC, benign and malignant tumors, low-grade and high-grade tumors. The best cut-off iodine content for differentiating clear cell from non-clear cell RCC was 3.2 mg/ml and clear cell from papillary RCC was 2.9 mg/ml with a high sensitivity and specificity. Also, significant difference was found between attenuation values of true and virtual unenhanced images (p = 0.007). Mean iodine content, absolute enhancement and enhancement ratio were highly correlated. Conclusion: rsDECT contributes to renal tumor characterization by showing higher iodine content in clear cell RCCs compared with non-clear cell RCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Antenna Microwave Ablation Under Contrast-Enhanced Ultrasound Guidance for Treatment of Small Renal Cell Carcinoma: Preliminary Experience

The purpose of this study was to determine the safety, effectiveness, and feasibility of microwave ablation (MWA) of small renal cell carcinomas (RCCs) in selected patients. Institutional review board and informed consent were obtained. From December 2007 to January 2009, 12 patients (8 male, 4 female) were enrolled in a treatment group, in which percutaneous MWA of small RCCs was performed under contrast-enhanced ultrasound guidance. The tumors were 1.7-2.9 cm in diameter (mean diameter, 2.0 cm).Therapeutic effects were assessed at follow-up with computed tomography. All patients were followed up for 3-14 months (mean, 6 months) to observe the therapeutic effects and complications (according to SIR classification). Assessment was carried out with CT imaging. No severe complications or unexpected side effects were observed after the MWA procedures. In all cases technical success was achieved. Clinical effectiveness was 100%; none of the patients showed recurrence on imaging. In conclusion, our preliminary results support the use of MWA for the treatment of small renal tumors. This technology can be applied in select patients who are not candidates for surgery, as an alternative to other ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The enhancer of zeste homolog 2 (EZH2), a potential therapeutic target, is regulated by miR-101 in renal cancer cells

Highlights: Black-Right-Pointing-Pointer EZH2 is overexpressed in the nuclei of renal cancer cells. Black-Right-Pointing-Pointer Nuclear EZH2 is associated with advanced stage and worse survival of RCC patients. Black-Right-Pointing-Pointer EZH2 is negatively regulated by miR-101 in renal cancer cells. Black-Right-Pointing-Pointer Depletion of EZH2 leads to re-expression of p27Kip1. Black-Right-Pointing-Pointer Reintroduction of miR-101 results in suppression of cell proliferation. -- Abstract: We investigated a prognostic significance and the mechanism of aberrant nuclear expression of EZH2, a histone methyltransferase, in human renal cell carcinoma (RCC). We found nuclear EZH2 in 48 of 100 RCCs and it was significantly correlated with worse survival in RCC patients. We detected a decreased expression of miR-101 in 15 of 54 RCCs. We found that re-expression of miR-101 resulted in EZH2 depletion and decreased renal cancer cell proliferation. Our results show nuclear EZH2 as a prognostic marker of worse survival in human RCC, and identify miR-101 as a negative regulator of EZH2 expression and renal cancer cell proliferation.

60 APPLIED LIFE SCIENCES↗