Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL SECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground-source Heat Pumps Applied to Commercial Buildings

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

15 GEOTHERMAL ENERGY↗

Identifying Cost-Effective Residential Energy Efficiency Opportunities for the Kauai Island Utility Cooperative

This analysis is an update to the 2005 Energy Efficiency Potential Study completed by KEMA for the Kauai Island Utility Cooperative (KIUC) and identifies potential energy efficiency opportunities in the residential sector on Kauai (KEMA 2005). The Total Resource Cost (TRC) test is used to determine which of the energy efficiency measures analyzed in the KEMA report are cost effective for KIUC toinclude in a residential energy efficiency program. This report finds that there remains potential energy efficiency savings that could be cost-effectively incentivized through a utility residential demand-side management program on Kauai if implemented in such a way that the program costs per measure are consistent with the current residential program costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Highlight: NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact Sheet)

Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods that can be used by technicians, researchers, or interested homeowners to verify the correct operation and energy efficiency of a home's air conditioning equipment. An efficiency validation method for mini-split heat pumps (MSHPs) - highly efficient refrigerant-based air conditioning and heating systems that permit room-by-room conditioning and control - will enable building researchers to easily explore the installed performance of this class of equipment. MSHPs are very popular overseas and are gaining market share in energy efficient home upgrades throughout the United States. Yet, because MSHPs have multiple variable-speed components that work in tandem, their performance is challenging to measure in a real home. NREL researchers developed a field evaluation method including test equipment, methods, and data analysis to determine the installed performance of this equipment in occupied homes. A field test was conducted to validate the method. When testing a home's operation, it is often important to simulate occupancy within an unoccupied home. That way, the researcher will know the actual usage profiles for heat and moisture generation; this removes the uncertainty associated with real occupants. The second test method details a standardized protocol for generating heat and moisture loads, to mimic occupants and their activities by using heaters and humidifiers. Realistic heat and moisture loads can be used to drive air conditioning systems, evaluate air distribution systems, and examine building enclosure technologies. These loads are drawn from the Building America House Simulation Protocols. Proper application of the method will result in better comparison between performance of the test home and its simulated analogue. This method is also validated by field testing. These test methods are now available in two technical reports. The methods can be used widely by the building research community to confirm proper operation of space conditioning equipment in homes, thereby improving thermal comfort, building health, and durability. National objectives for cost-effective energy savings in the residential sector can be met more quickly and with greater consistency.

14 SOLAR ENERGY↗

PACE Status Update

The Federal Housing Finance Agency (FHFA) regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On July 6, 2010, FHFA and the Office of the Comptroller of the Currency (OCC) concluded that Property Assessed Clean Energy (PACE) programs 'present significant safety and soundness concerns' to the housing finance industry. This statement came after a year of discussions with state and federal agencies in which PACE, a novel mechanism for financing energy efficiency and renewable energy improvements, has gone from receiving support from the White House, canonization as one of Scientific American's 'World Changing Ideas' and legislative adoption in 24 states to questionable relevance, at least in the residential sector. Whether PACE resumes its expansion as an innovative tool for financing energy efficiency and clean generation depends on outcomes in each of the three branches of government - discussions on a PACE pilot phase among federal agencies, litigation in federal court, and legislation in Congress - all highly uncertain. This policy brief addresses the practical impacts of these possible outcomes on existing and emerging PACE programs across the United States and potential paths forward.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China

This study seeks to provide policymakers and other stakeholders with actionable information towards a road map for reducing energy consumption cost-effectively. We focus on individual end use equipment types (hereafter referred to as appliance groups) that might be the subject of policies - such as labels, energy performance standards, and incentives - to affect market transformation in the short term, and on high-efficiency technology options that are available today. As the study title suggests, the high efficiency or Business Case scenario is constructed around a model of cost-effective efficiency improvement. Our analysis demonstrates that a significant reduction in energy consumption and emissions is achievable at net negative cost, that is, as a profitable investment for consumers. Net savings are calculated assuming no additional costs to energy consumption such as carbon taxes. Savings relative to the base case as calculated in this way is often referred to as 'economic savings potential'. Chinese energy demand has grown dramatically over the last few decades. While heavy industry still plays a dominant role in greenhouse gas emissions, demand from residential and commercial buildings has also seen rapid growth in percentage terms. In the residential sector this growth is driven by internal migration from the countryside to cities. Meanwhile, income in both urban and rural subsectors allows ownership of major appliances. While residences are still relatively small by U.S. or European standards, nearly all households own a refrigerator, a television and an air conditioner. In the future, ownership rates are not expected to grow as much as in other developing countries, because they are already close to saturation. However, the gradual turnover of equipment in the world's largest consumer market provides a huge opportunity for greenhouse gas mitigation. In addition to residences, commercial floor space has expanded rapidly in recent years, and construction continues at a rapid pace. Growth in this sector means that commercial lighting and HVAC will play an increasingly important role in energy demand in China. The outlook for efficiency improvement in China is encouraging, since the Chinese national and local governments have implemented significant policies to contain energy intensity and announced their intention to continue and accelerate these. In particular, the Chinese appliance standards program, first established in 1989, was significantly strengthened and modernized after the passage of the Energy Conservation Law of 1997. Since then, the program has expanded to encompass over 30 equipment types (including motor vehicles). The current study suggests that, in spite of these efforts, there is significant savings to be captured through wide adoption of technologies already available on the Chinese market. The approach of the study is to assess the impact of short-term actions on long-term impacts. 'Short-term' market transformation is assumed to occur by 2015, while 'long-term' energy demand reduction impacts are assessed in 2030. In the intervening years, most but not all of the equipment studied will turn over completely. Early in 2011, the Chinese government announced a plan to reduce carbon dioxide emissions intensity (per unit GDP) by 16% by 2015 as part of the 12th five year plan. These targets are consistent with longer term goals to reduce emissions intensity 40-45% relative to 2005 levels by 2020. The efforts of the 12th FYP focus on short-term gains to meet the four-year targets, and concentrate mainly in industry. Implementation of cost-effective technologies for all new equipment in the buildings sector thus is largely complementary to the 12th FYP goals, and would provide a mechanism to sustain intensity reductions in the medium and long term. The 15-year time frame is significant for many products, in the sense that delay of implementation postpones economic benefits and mitigation of emissions of carbon dioxide. Such delays would result in putting in place energy-wasting technologies, postponing improvement until the end of their service life, or potentially resulting in expensive investment either in additional energy supplies or in early replacement to achieve future energy or emissions reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Studies of Duct Retrofits and Guidelines for Attic and Crawl Space Duct Sealing

The U.S. Department of Energy (DOE) is fully committed to research for developing the information and capabilities necessary to provide cost-effective residential retrofits yielding 50% energy savings within the next several years. Heating, ventilation, and air conditioning (HVAC) is the biggest energy end use in the residential sector, and a significant amount of energy can be wasted through leaky ductwork in unconditioned spaces such as attics and crawl spaces. A detailed duct sealing case study is presented for one house along with nine brief descriptions of other duct retrofits completed in the mixed-humid climate. Costs and estimated energy savings are reported for most of the ten houses. Costs for the retrofits ranged from $\$$0.92/ft 2 to $\$$1.80/ft 2 of living space and estimated yearly energy cost savings due to the duct retrofits range from 1.8% to 18.5%. Lessons learned and duct sealing guidelines based on these ten houses, as well as close work with the HVAC industry in the mixed-humid climate of East Tennessee, northern Georgia, and south-central Kentucky are presented. It is hoped that the lessons learned and guidelines will influence local HVAC contractors, energy auditors, and homeowners when diagnosing or repairing HVAC duct leakage and will be useful for steering DOE s future research in this area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector's energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level. The Incremental Ventilation Energy (IVE) model developed in this study combines the output of simple air exchange models with a limited set of housing characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modellers to use existing databases of housing characteristics to determine the impact of ventilation policy change on a population scale. The IVE model estimates of energy change when applied to US homes with limited parameterisation are shown to be comparable to the estimates of a well-validated, complex residential energy model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector’s energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2016 End of the year South Carolina PV soft cost and workforce development

A solar industry survey was given to professional installers who serve the South Carolina market in order to determine trends in costing, work force needs, and business demographics at the end of 2016. It was found that 70% of the respondents serve the residential sector, while only 7% of the total exclusively serves the residential market. The average size of residential installations remain near 9 kW-DC, while the average size of commercial and utility scale installations continue to grow to 378 kW-DC and 14.8 MW-DC, respectively. The total cost of these residential systems has hovered around $3.50/W-DC since the end of 2015, while commercial installations have dropped to $2.45/W-DC and utility scale installations have dropped to $1.49/W-DC. It is expected that the cost of utility scale installations will continue to drop as there are publically reported utility scale installations with contracted PPAs for less than 4¢/kWh. 52-60% of the cost is associated with hardware only depending upon sector.

14 SOLAR ENERGY↗

Update of Residential Load Profile for WECC Load Composition Model Using Cross-Correlation Method

The Western Electricity Coordinating Council (WECC) initiated the development of a composite load model for transmission-level power system simulators. To more precisely utilize the model to represent the power consumption pattern for various locations of the WECC network, an up-to-date load composition dataset is required. The study in this paper aims to reconstruct the residential sector of the load composition model (LCM) dataset using latest survey or measurement data. The LCM residential dataset contains load profiles for twelve climate zones and five season types. The northwest energy efficiency alliance (NEEA) launched a study to generate the load profiles for four climate zones in the Pacific Northwest. Based on the NEEA database, a component-wise cross-correlation-based approach has been developed in this paper to update the obsolete residential load profiles of the four pacific northwest climate zones and populate the new load shape data into the other eight climate zones.

Liu, Yuan↗

Impact of Rate Design Alternatives on Residential Solar Customer Bills. Increased Fixed Charges, Minimum Bills and Demand-based Rates

With rapid growth in energy efficiency and distributed generation, electric utilities are anticipating stagnant or decreasing electricity sales, particularly in the residential sector. Utilities are increasingly considering alternative rates structures that are designed to recover fixed costs from residential solar photovoltaic (PV) customers with low net electricity consumption. Proposed structures have included fixed charge increases, minimum bills, and increasingly, demand rates - for net metered customers and all customers. This study examines the electricity bill implications of various residential rate alternatives for multiple locations within the United States. For the locations analyzed, the results suggest that residential PV customers offset, on average, between 60% and 99% of their annual load. However, roughly 65% of a typical customer's electricity demand is non-coincidental with PV generation, so the typical PV customer is generally highly reliant on the grid for pooling services.

14 SOLAR ENERGY↗

Data-Enabled Building Energy Savings (D-E BES)

Building sector energy consumption represents a significant fraction of the overall energy consumption in urban communities. While there has been increasing focus on the development of smart environments to support energy savings in urban commercial buildings, the development of smart environments for the residential sector has been less common. Instead, urban residential energy-saving efforts have focused on improving a building's physical infrastructure, introducing energy-saving appliances, and motivating residents to adopt energy conservation practices. Herein this paper illustrates that creating an affinity between a building resident's thermal preferences and a building apartment's unregulated thermal environment represents an alternative means of generating an energy-efficient environment for multi-family, residential buildings. Two years of 15-min interval summer data, obtained from smart cyber-physical systems installed in 310 apartments across two New York City buildings, is used to develop data-enabled (D-E) models of resident thermal preference and unregulated apartment temperatures. Both of these models use a linear mixed-effects approach. The alignment of optimal resident-apartment pairs is then formulated as an integer-programming problem to explore the building energy saving (BES) potential associated with minimizing the difference between unregulated apartment temperature and the residents' thermal preference based on summer cooling loads. The work shows that the energy saving potential vary with a building's physical characteristics as well as the variation in residents' thermal preferences. The work further demonstrates that both the unregulated temperature and the resident's preferred temperature in a given apartment are not only affected by outside temperature and external relative humidity, but also strongly affected by the apartment's geographic orientation. For the specific buildings considered, up to 28% cooling energy saving is possible with full alignment. The paper provides all building monitoring data as an open source data set.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

American Homeowner Perceptions and Choices for Energy Efficiency: Summary of Technology Adoption – Census Division Level

In 2020 a nationwide survey of homeowners was conducted to determine what energy efficiency upgrades homeowners had made to their homes and which ones they would make in the near future. The survey also included results on respondent financials about energy efficiency home upgrades/retrofits and perceptions of the value of energy efficiency/who should support improving the energy efficiency of the residential sector. The Department of Energy’s goal for this survey is to inform ongoing work in the residential energy efficiency research portfolio on the human dimensions of residential energy systems transformation. In addition, DOE envisions this work supports efforts by industry, non-profits, and other government partners in informing programming, customer discovery, and policy writ large. This report provides a general summary of the nationwide results as they pertain to the following three issues: (1) how much did respondents indicate spending on energy efficiency-related home upgrades, (2) what upgrades/improvements had they made to their homes, and (3) which upgrades/improvements do they believe have the most significant impact on energy efficiency. The results provided are segmented by census division as specific regions demonstrated unique preferences for energy efficiency and willingness to expend family resources to achieve those goals. As such, the goal of this report is not to analyze the data nor draw cross-cutting conclusions but to serve as a resource for any groups interested in reviewing national trends about residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Powered Aerogel-Based Adsorptive Air Conditioning

The DOE estimates the total primary energy consumption for commercial buildings was 10.72 quadrillion BTU (quads) in 1983, compared with 14.74 quads for the residential sector. According to the DOE Building Technologies Program, 40–60% of the energy used in U.S. commercial (and residential) buildings is for HVAC, creating massive potential for energy savings with a system that could cut cooling energy use by at least 30–60%. Initial vertical segments in the commercial building market include government and commercial office buildings; government facilities such as prisons, military bases, and schools; hotels and resorts; farming, wineries and other rural facilities; and general light industrial offices (e.g., printers and clothing makers). We propose a solar powered aerogel-based adsorption cooling system, including the completion and testing of a working prototype at an existing HVAC testing facility and technology-maturation testing at an existing beta-testing site. In the cooling system, solar radiation is focused by solar collectors onto on bed, which contains ultra high surface area aerogel. Heating causes thermal desorption of a refrigerant previously adsorbed into the aerogel’s pores. Refrigerant desorption increases the gas-phase pressure in the pores, thereby forcing the gaseous refrigerant to flow out of the first irradiated bed (Bed A) and through a two-stage condenser. In the condenser, heat is first removed from the hot gaseous refrigerant by a stream of water that eventually flows into a hot water heater and storage system. The refrigerant is then further cooled by chilled refrigerant leaving the evaporator after vaporization. After passing through the two-stage condenser, the gaseous refrigerant undergoes expansion through an expansion valve. A portion of the refrigerant condenses in the evaporator, while some of the refrigerant is flashed and exits the evaporator. The evaporator absorbs heat from the area being cooled, which results in further vaporization of the refrigerant. The cool, vaporized refrigerant leaves the evaporator, passing through tubes in the shell-and-tube heat exchanger comprising the second stage of the two-stage condenser. After leaving the tube side of this heat exchanger, it flows to the second bed of aerogel (Bed B), which is maintained at a relatively low temperature by water entering the building and destined for the hot water tank. During the first cycle, most of the refrigerant adsorbs on Bed B. When the refrigeration cycle is reversed, the refrigerant is thermally desorbed from Bed B, and adsorbed on the cooler Bed A. As the cycling rate increases, the quantity of adsorption media, the system size, and the associated cost becomes smaller. It appears that an optimized system can meet targeted performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2015 South Carolina PV Soft Cost and Workforce Development Part 2: Six Month Confirmation of Anticipated Job Growth

In 2015, a program was initiated to carefully track and monitor the growth of the solar industry in SC. Prior to then, little information was available on the costs associated with distributed photovoltaic (PV) installations in the Southeastern US. For this report, data were collected from businesses on the number of hires they had at the end of 2014 and compared with data for 2015 and June 2016. It was found that the percentage of installers within the state who serve the residential sector increased to 82% from 67%. During the same time period, the average size of initiated installations for residential, commercial, and utility scale installations all trended upwards. Where residential installations were typically 5 kW-DC in 2014, they were typically 10 kW-DC by late 2015 and in mid-2016. For commercial installations, the average size grew from 84 kW-DC in 2014 to between 136-236 kW-DC in 2015 and then 188-248 kWDC in mid-2016. An exception was seen in utility scale installations where a 2.3 MW-DC system was common in 2014, the size grew to be 5-15 MW-DC in late 2015. The average size dropped 3.1-4.4 MWDC in mid-June 2016, though individual averages up to 20 MW-DC were reported.

99 GENERAL AND MISCELLANEOUS↗

Beyond-the-Meter: Unaccounted Sources of Methane Emissions in the Natural Gas Distribution Sector

The United States Environmental Protection Agency maintains an inventory of greenhouse gas emissions in accordance with the Intergovernmental Panel on Climate Change. Methane (CH 4 ), a potent gas with a global warming potential 86–125× that of carbon dioxide (CO 2 ) over a twenty-year period, is the main component of natural gas (NG). As NG becomes an increasingly larger percentage of the energy resources used in the United States, it is ever more important to evaluate the CH 4 emissions inventory. However, the inventory also does not account for all possible sources of CH 4 leaks, contributing to uncertainty in the national CH 4 inventory. Discrepancies between top-down and bottom-up inventories of CH 4 emissions imply that there are significant unaccounted-for sources of CH 4 leaks, especially over cities. Diffuse CH 4 plumes above cities that are not attributable to distribution pipelines or other NG infrastructure suggest many small beyond-the-meter leaks together contribute to large emissions. Here, we evaluate the distribution sector of the CH 4 emissions inventory and make suggestions to improve the inventory by analyzing end-user emissions. Preliminary research into beyond-the-meter emissions suggests that while individually small, the appliances and buildings that make up the residential sector could contribute significantly to national scale emissions. Furnaces are the most leak-prone of appliances, contributing to 0.14% of total CH 4 emissions from the NG sector in the United States. Combining measurements from whole house emissions and steady-state operation of appliances, we estimate that residential homes and appliances could release 9.1 Gg CH 4 yearly in the United States, totaling over 2% of the CH 4 released from the NG sector. Here, while factors such as appliance age and usage, climate, and residential setting could influence the emissions profile of individual appliances, these preliminary estimates justify further exploration of beyond-the-meter emissions.

03 NATURAL GAS↗