At least 55 records · Page 3

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux Channeling Induced Nanoconfinement and Enhancement of Microwaves Imaged by Rabi Oscillation Mapping

With rapid advances in qubit technologies, techniques for localizing, modulating, and measuring RF fields and their impact on qubit performance are of the utmost importance. Here, we demonstrate that flux-channeling from a permalloy nanowire can be used to achieve localized spatial modulation of an RF field and that the modulated field can be mapped with high resolution by using the Rabi oscillations of an NV center. Rabi maps reveal ∼100 mm wavelength microwaves concentrated in sub-300 nm regions with up to ∼16× power enhancement. This modulation is robust over a 20 dBm power range and has no adverse impact on NV T 2 coherence time. Micromagnetic simulations confirm that the modulated field results from the nanowire’s stray field through its constructive/destructive interference with the incident RF field. Our findings provide a new pathway for controlling qubits, amplifying RF signals, and mapping local fields in various on-chip RF technologies.

Diamond↗

Development and characterization of Nb3Sn/Al2O3 superconducting multilayers for particle accelerators

Abstract Superconducting radio-frequency (SRF) resonator cavities provide extremely high quality factors > 10 10 at 1–2 GHz and 2 K in large linear accelerators of high-energy particles. The maximum accelerating field of SRF cavities is limited by penetration of vortices into the superconductor. Present state-of-the-art Nb cavities can withstand up to 50 MV/m accelerating gradients and magnetic fields of 200–240 mT which destroy the low-dissipative Meissner state. Achieving higher accelerating gradients requires superconductors with higher thermodynamic critical fields, of which Nb 3 Sn has emerged as a leading material for the next generation accelerators. To overcome the problem of low vortex penetration field in Nb 3 Sn, it has been proposed to coat Nb cavities with thin film Nb 3 Sn multilayers with dielectric interlayers. Here, we report the growth and multi-technique characterization of stoichiometric Nb 3 Sn/Al 2 O 3 multilayers with good superconducting and RF properties. We developed an adsorption-controlled growth process by co-sputtering Nb and Sn at high temperatures with a high overpressure of Sn. The cross-sectional scanning electron transmission microscope images show no interdiffusion between Al 2 O 3 and Nb 3 Sn. Low-field RF measurements suggest that our multilayers have quality factor comparable with cavity-grade Nb at 4.2 K. These results provide a materials platform for the development and optimization of high-performance SIS multilayers which could overcome the intrinsic limits of the Nb cavity technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-volume tunable resonator for axion searches above 7 GHz

In this research, we present results from an experimental demonstration of a tunable thin-shell axion haloscope whose geometry decouples its overall volume from its resonant frequency, thereby evading the steep sensitivity degradation at high frequencies. An aluminum 2.6-l (41⁢λ 3 ) prototype, which tunes from 7.1 to 8.0 GHz, was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable TM 010 mode is clearly identified with a room-temperature quality factor, Q, of approximately 5000. The on-resonance E-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of 0.57 across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume V $\gg$ λ 3 . We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the postinflationary axion parameter space (approximately 4 to 30 GHz) at Dine-Fischler-Srednicki-Zhitnitsky sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature, rf field, and frequency dependence performance evaluation of superconducting niobium half-wave coaxial cavity

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating gradient. The increase in quality factor is the result of a decrease in the surface resistance as a result of nonmagnetic impurities doping and change in electronic density of states. The fundamental understanding of the dependence of surface resistance on frequency and surface preparation is still an active area of research. Here, we present the result of RF measurements of the TEM modes in a coaxial half-wave niobium cavity resonating at frequencies between 0.3 ? 1.3 GHz. The temperature dependence of the surface resistance was measured between 4.2 K and 1.6 K. The field dependence of the surface resistance was measured at 2.0 K. The baseline measurements were made after standard surface preparation by buffered chemical polishing.

Dhakal, P.↗

Studies as a function of different ALD capping layers on cavity losses for QIS and accelerators

Niobium-based bulk SRF cavities have demonstrated exceptional performance. To further improve niobium cavity performance, we present studies involving a novel surface engineering process designed to prevent the formation of amorphous niobium oxides on the surface. This is achieved by encapsulating the niobium surface using thermal Atomic-Layer-Deposition (ALD). This technique has been shown to enhance the properties of niobium cavities and 2D resonators. This study not only aims to improve SRF performance at high fields but also has the potential to enhance the quality factor in low-field regimes, particularly for quantum applications. For the method to be effective, it is essential to have a clean interface between the encapsulating layer and the bulk niobium. Achieving this requires a uniform coating across the entire cavity surface and efficient removal of the underlying niobium oxides. To optimize the process, a variety of material characterization tools have been utilized to refine parameters such as thin film thickness and annealing conditions. Cavity RF measurements were performed at the vertical test facilities at FNAL to assess the Q vs. Eacc curves for accelerator applications, as well as at the SQMS dilution refrigerators to investigate the full two-level system (TLS) losses at milliKelvin and single-photon levels. Based on the results, we characterized the loss of different oxides in various regimes and applications, comparing them to natural niobium pentoxide.

Grassellino, L. [Fermilab]↗

R. F. testing of the third generation defense communication satellite

The approach taken to test a completed DSCS communications satellite on a system level is described. Areas to be described are measuring RF isolation of separate communications subsystems and a test method which insures that one RF subsystem does not interfere with another. In addition, the method of complying with MIL-STD-1541 in the area of demonstrating safety of electroexplosive devices in an RF field is discussed.

Sargent, J.↗

Array-fed reflector antenna design and applications

One phase of the spacecraft antenna research carried out at the Jet Propulsion Laboratory for deep space and near-earth communications is described. Array-fed reflector antenna designs have been elaborated for beam scanning, power amplification, and multiple beam applications. The antenna designs derive from similar optical concepts. Each antenna comprises a relatively small plane-wave array feeding a near-field dual-reflector system. The main reflector and the the subreflector are confocal paraboloids having identical focal length to diameter ratios. The array feed is positioned in such a way that the subreflector is in the near-field (collimated beam) region of the feed. The field distribution of the feed aperture is thereby recreated approximately in the main reflector aperture. The detailed design concepts of the antennas (beam-scanning, high-power, and mutliple-beam) are discussed, and the calculated and measured RF performances of the antennas are presented.

Woo, K.↗

Large antenna experiments aboard the space shuttle: Application of nonuniform sampling techniques

Future satellite communication and scientific spacecraft will utilize antennas with dimensions as large as 20 meters. In order to commercially use these large, low sidelobe and multiple beam antennas, a high level of confidence must be established as to their performance in the 0-g and space environment. Furthermore, it will be desirable to demonstrate the applicability of surface compensation techniques for slowly varying surface distortions which could result from thermal effects. An overview of recent advances in performing RF measurements on large antennas is presented with emphasis given to the application of a space based far-field range utilizing the Space Shuttle and the concept of a newly developed nonuniform sampling technique.

Rahmatsamii, Y.↗

High-efficiency helical traveling-wave tube with dynamic velocity taper and advanced multistage depressed collector

A NASA-sponsored research and development contract has been established with the Watkins-Johnson Company to fabricate high-efficiency 20-watt helical traveling wave tubes (TWTs) operating at 8.4 to 8.43 GHz. The TWTs employ dynamic velocity tapers (DVTs) and advanced multistage depressed collectors (MDCs) having electrodes with low secondary electron emission characteristics. The TWT designs include two different DVTs; one for maximum efficiency and the other for minimum distortion and phase shift. The MDC designs include electrodes of untreated and ion-textured graphite as well as copper which has been treated for secondary electron emission suppression. Objectives of the program include achieving at least 55 percent overall efficiency. Tests with the first TWTs (with undepressed collectors) indicate good agreement between predicted and measured RF efficiencies with as high as 30 percent improvement in RF efficiency over conventional helix designs.

Curren, Arthur N.↗

Modeling, design, fabrication, and testing of InP Gunn devices in the D-band (110 GHz - 170 GHz)

The development of fundamental Gunn sources for D-band frequencies requires improvements of doping profiles, processing technology, and circuit design. We have developed a technology for fabricating InP Gunn diodes using an InGaAs etch-stop layer between the InP substrate and the device layers. The epitaxial layers were grown by CBE. During device processing, the substrate is completely removed. Substrateless devices with an n(+) InGaAs cap layer are expected to have reduced contact and series resistances, and skin effect losses. This technology gives better uniformity and control of the device geometry across the processed chip. InP Gunn devices with a 1.7 micron long active region (doping : 9 x 10(exp 15) cm(exp -3)) have been mounted on copper heat sinks. Two tapered leads were then bonded to the diode and to four quartz standoffs. As a preliminary result, an output power of 13 mW at 82 GHz was obtained. Based on these RF measurements, we determine appropriate material parameters to be used in the Ensemble Monte Carlo model. Subsequently, we use this model to design and evaluate the performance of InP Gunn Devices for D-band frequencies. Using the same technology, we are currently processing Gunn devices with a 1 micron long active region for operation at higher frequencies.

Kamoua, R.↗

Planar doped barrier subharmonic mixers

The Planar Doped Barrier (PDB) diode is a device consisting of a p(+) doping spike between two intrinsic layers and n(+) ohmic contacts. This device has the advantages of controllable barrier height, diode capacitance and forward to reverse current ratio. A symmetrically designed PDB has an anti-symmetric current vs. voltage characteristic and is ideal for use as millimeter wave subharmonic mixers. We have fabricated such devices with barrier heights of 0.3, 0.5 and 0.7 volts from GaAs and InGaAs using a multijunction honeycomb structure with junction diameters between one and ten microns. Initial RF measurements are encouraging. The 0.7 volt barrier height 4 micron GaAs devices were tested as subharmonic mixers at 202 GHz with an IF frequency of 1 GHz and had 18 dB of conversion loss. The estimated mismatch loss was 7 dB and was due to higher diode capacitance. The LO frequency was 100.5 GHz and the pump power was 8 mW.

Lee, T. H.↗

Modem Characterization Through a Wideband, Hard-Limited Ka-Band Satellite Channel

NASA is using a commercial customized TDMA/FDMA bandwidth on demand modem for use with the Advanced Communications Technology Satellite (ACTS) to highlight the numerous services and experiments that can be performed using small Ka-Band terminals. Characterizing the modems proved challenging due to the characteristics of the satellite transponder. The ACTS channel is hard-limited and up to 900 MHz wide. The channel has some unusual dynamic properties due to the satellite and antenna system, which make modem testing through the satellite challenging and the test requirements stringent. The satellite Multi-Beam Antenna (MBA) has a 1 hertz oscillation induced by the momentum wheel, which causes the transmit antenna pattern to move slightly. This results in a 1 hertz oscillation in the ground station receive power, with amplitude changes up to 1 dB depending on terminal location within a spot beam and associated gain slope. In addition, ACTS experiences a solar induced "thermal event" each day. This "thermal event" occurs when the sun heats the antenna support structure causing the transmit and receive reflectors to mispoint. This results in a slowly decreasing or increasing power density at the ground station receiver as the antenna pattern moves off bore-site. This paper describes the method used to fully characterize the TDMA/FDMA modem through the ACTS wideband, hard-limited transponder. In particular, techniques are discussed for conducting RF measurements on such a channel, the affect that the thermal characteristics and 1 hertz variations have on the accuracy of the results, and suggested means to minimize the error and provide useful and valuable data.

Reinhart, Richard C.↗

Neurolab Biotelemetry System (NBS)

This system was developed by the Sensors 2000! Program (S2K!) at Ames Research Center for the E132 STS-90 Neurolab Shuttle mission experiment to monitor 12 untethered adult male rats housed in the Research Animal Habitat Facility (RAHF). The system monitored the animals for body temperature, heart rate, and activity, and stored the data on board for up to 21 days for downloading after landing. The principal investigator's monitoring requirements were accomplished integrating a combination of both commercial and in-house developed hardware and software, including an off-the-shelf implantable telemetry transmitter and receiver system. In addition, a custom-developed antenna system was incorporated into the RAHF cages to perform the unique function of near-field radio-frequency (rf) measurement in the metal cages. This system proved the ability to perform wireless physiological measurements in very non-ideal circumstances using existing habitats and cabling without interfering with other experiment or shuttle systems. S2K! is continuing development on a custom telemetry transmitter and receiver system which will expand measurement capabilities.

Schonfeld, J.↗

Growth and Properties of Vapor Diffused Nb3Sn Coating for Superconducting Radiofrequency Accelerator Cavity Applications

The desire to reduce construction and operating costs of future SRF accelerators motivates the search for higher-performing alternative materials. Nb3Sn (Tc ~ 18.3 K and Hsh ~ 425 mT) is the front runner. The tin vapor diffusion process is currently the technique of choice to produce promising Nb3Sn-coated cavities. Understanding Nb3Sn nucleation and growth in this process is essential to progress. Samples representing different stages of Nb3Sn formation have been produced and studied to elucidate the effects of nucleation, growth, process conditions, and impurities. Nb3Sn films with thickness from a few hundred nm up to ~15 µm were grown and characterized. The microscopic examination of samples suggests the mechanisms of thin film nucleation and growth. Broadly, nucleation deposits tin as a thin surface phase and, under some conditions, a few hundred nanometer sized particles as well. Conditions that impair nucleation promote the formation of defects, such as ?patches?, in subsequent coating growth. Analysis of coated samples is consistent with the model of Nb3Sn grown in which tin diffuses via grain boundaries to Nb3Sn-Nb interface, where the growth Nb3Sn into the niobium bulk takes place. Similar scaling laws are found for grain growth and layer thickness. Non-parabolic layer growth is consistent with significant grain growth, which reduces the number of Sn-transport channels. Examination of patchy region in Nb3Sn coating revealed it to be large single crystalline grains, pointing to impeded Nb3Sn layer growth due to low grain boundary density, resulting in a significantly thin coating in those areas. Examination of RF loss regions from a coated cavity, identified with a thermometry mapping system showed patchy regions and carbonus defects were associated with strong local field-dependent surface resistance. RF measurements of coated cavities were combined with material characterization of witness samples and coated-cavity cutouts to improve the coating process. Understanding obtained and applied to cavity coatings, resulted in single-cell Nb3Sn cavities with a quality factor of ~2 ×1010 up to 15 MV/m accelerating gradient at 4 K, without "Wuppertal" Q-slope. We have also produced Nb3Sn-coated CEBAF 5-cell cavities with accelerating gradients useful for accelerator cryomodules. This dissertation will discuss the genesis of the Nb3Sn coating in a typical tin vapor diffusion process, effects of different process parameters, and its consequences to the coating of single-cell and multi-cell SRF cavities.

Pudasaini, Uttar↗

Design and optimization of higher order mode couplers for the superconducting cavities of the PERLE energy recovery linac

The Powerful Energy Recovery Linac for Experiments (PERLE) is an energy recovery linac (ERL) facility based on superconducting radio-frequency (SRF) technology to be hosted at the Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab) in France. With a target beam power of 10 MW, PERLE aims to demonstrate the high-current, continuous wave, multi-pass operation to validate options for future high-energy machines, such as the 50 GeV ERL proposed for the Large Hadron electron Collider (LHeC) and the Future Circular electron-hadron Collider (FCC-eh), and host dedicated particle physics and nuclear experiments. In high-current ERLs, the regenerative Beam Breakup (BBU), emerging from the beam and cavity Higher Order Modes (HOMs) interaction, is a major concern for their stable operation. Beam-induced HOMs can increase the cavity heat load at cryogenic temperature and cause beam instabilities. HOM couplers are installed in the cavity beam pipes to absorb HOM energy and mitigate these effects. This thesis presents the design and optimization of several coaxial HOM couplers for the 5-cell 801.58 MHz elliptical Nb cavities of the 500 MeV PERLE ERL configuration. The RF transmission of the HOM couplers was optimized to enhance the damping of the most dangerous HOMs. The optimized HOM couplers were integrated into endgroups to simulate their damping performance and thermal behavior. The optimized HOM couplers were 3D-printed in epoxy and copper-coated. Low-power RF measurements were conducted on the produced HOM couplers installed in copper PERLE-type cavities to validate their damping performance and propose several endgroups for the PERLE 5-cell cavity to mitigate HOMs below the BBU instability limits.

Barbagallo, Carmelo↗

Distributed and Secure Spectrum Sharing for 5G and 6G Networks

Secure spectrum sharing or spectrum co-existence of multiple 5G networks and future 6G networks is a powerful enabler technology. The National Spectrum Strategy (NSS) published by the White House in November, 2023, and the subsequent NSS implementation plan led by the National Telecommunication and Information Administration (NTIA) is the driver of a national effort to enable co-existence of government incumbents and commercial networks in selected spectrum bands. Cellular networks such as 5G & 6G and non-cellular Wi-Fi 6E & 7 are the prominent wireless technologies considered for co-existence with incumbent wireless links. Security of the spectrum sharing solutions is a must to make this transformation of spectrum use possible, specially for mission critical communications. However, current spectrum sharing solutions rely on centralized data bases with inherent vulnerabilities. This paper focuses on secure spectrum sharing among multiple 5G networks using unlicensed and shared frequency bands. It presents an innovative AI/ML based distributed spectrum sharing approach that can be autonomously used by multiple networks. Each sharing network uses its own observation of the Radio Frequency (RF) environment, which consists of RF measurements reported from the 5G User Equipment (UE), to adjust the transmission power levels for secure co-existence. Data is presented to illustrate the superior performance of this solution compared to other spectrum sharing solutions where each network can utilize usage data of the other networks. Finally it discusses how this efficient spectrum sharing solution can evolve in the future for the 6G networks.