At least 55 records · Page 3

Analysis of RF losses and material characterization of samples removed from a Nb 3 Sn-coated superconducting RF cavity

Nb 3 Sn (T c ≈18 K and H sh ≈400 mT) is a prospective material to replace Nb (T c ≈9 K and H sh ≈200 mT) in SRF accelerator cavities for significant cost reduction and performance enhancement. Because of its material properties, Nb3Sn is best employed as a thin film (coating) inside an already built RF cavity structure. A particular test cavity noted as C3C4 was a 1.5 GHz single-cell Nb cavity, coated with Nb3Sn using Sn vapor diffusion process at Jefferson Lab. Cold measurements of the coated cavity indicated the superconducting transition temperature of about 18 K. Subsequent RF measurements indicated field-dependent surface resistance both at 4.3 K and 2.0 K. After initial cold measurements, the cavity RF loss distribution was studied with a thermometry mapping system. Loss regions were identified with thermometry and were cut out for material analysis. The presence of significantly thin patchy regions and other carbon-rich defects is associated with strong local field-dependent surface resistance. This paper summarizes RF and thermometry results correlated with material science findings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon

Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF

This work details the construction and first in operando transient grating spectroscopy measurements conducted on PISCES-RF during plasma operation. A preliminary study on a tungsten sample with varied plasma species (Ar and D 2 ), ion flux (4 × 10 21 to 6 × 10 22 ion/m 2 /s), ion energy (5 to 80 eV), and surface temperature (20 to 200 °C) is presented. Prior to plasma exposure, the thermal diffusivity and surface acoustic wave (SAW) speed, (6.9 ± 0.2) × 10 −5 m 2 /s and (2.66 ± 0.02) km/s, were measured in situ with a thermal grating period of 12.5 μm. During Ar plasma exposure, these two quantities vary according to the sample surface temperature. At low flux and varied ion energy, D 2 plasma exposure also results in thermal diffusivity and SAW speed varying with surface temperature alone. At high flux, D 2 plasma exposure results in no convincing change to the thermal diffusivity, but the SAW speed is reduced. After returning to 20 °C, post plasma exposures, the thermal diffusivity and SAW speed almost recover to the initial value prior to exposure.

Surface acoustic wave SAW↗

Pressurized Gas Beam Monitor for Extremely High Intensities – Phase II

A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. Standard RF techniques to measure the change in quality factor (Q) and frequency (f) as a function of time are then used to determine the change in permittivity and corresponding beam intensity in each cavity in the profile monitor. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire multi-RF-cavity system has been designed and a demonstration test has been prepared.

43 PARTICLE ACCELERATORS↗

Tunable competing magnetic anisotropies and spin reconfigurations in ferrimagnetic Fe 100– x Gd x alloy films

Here, we report a comprehensive study of the temperature evolution of in-plane (IP) and out-of-plane (OOP) effective magnetic anisotropies in compensated ferrimagnetic Fe 100– x Gd x alloy films by employing direct current magnetometry and radiofrequency (RF) transverse susceptibility (TS) measurements. We suggest that our Fe 100– x Gd x system is chemically inhomogeneous and phase segregates into Fe- and Gd-enriched regions. Our IP and OOP magnetometry results indicate that the system undergoes a temperature-driven transformation from an IP-spin-configuration-dominated state to an OOP-spin-configuration-dominated state below a certain temperature (spin reorientation temperature). A two-step reversal behavior emerges in the OOP $\textit{M(H)}$ loop near compensation, which we attribute to the sequential magnetization reversals of Fe- and Gd-enriched domains. Field-induced spin-flop transitions were also observed near the compensation. Our RF TS measurements indicate that the effective magnetic anisotropy for the OOP configuration dominates over that for the IP configuration below a certain spin reorientation temperature. Both IP and OOP anisotropy fields determined from our TS measurement exhibit a minimum around the compensation temperature, which has been explained in the framework of the Stoner-Wohlfarth model.

36 MATERIALS SCIENCE↗

RF surface resistance tuning of superconducting niobium via thermal diffusion of native oxide

Recently, Nb superconducting radio frequency cavities vacuum heat treated between 300 and 400°C for a few hours have exhibited very high quality factors (~5 × 10 10 at 2.0 K). Secondary ion mass spectrometry measurements of O, N, and C show that this enhancement in RF surface conductivity is primarily associated with interstitial O alloying via dissolution and diffusion of the native oxide. We use a theory of oxide decomposition and O diffusion to quantify previously unknown parameters crucial in modeling this process. RF measurements of a vacuum heat-treated Nb superconducting radio frequency cavity confirm the minimized surface resistance (higher Q 0 ) previously expected only from 800 °C diffusive alloying with N.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

Measurement of the properties of the dust acoustic wave in a magnetic field

We present the first experimental observations of the dust acoustic wave where the wave was observed to propagate in the directions of gravity and magnetic field when these directions were not aligned. The experiments were conducted in the Magnetized Dusty Plasma eXperiment facility using a novel electrode system that allows for the angle between gravity and the magnetic field to be varied in a controlled way. This letter reports on measurements in an rf glow discharge argon plasma environment where the angle between direction of gravity and the magnetic field is 45 $^{\circ }$ . When there was no applied magnetic field, the wave was observed to propagate in the direction of gravity. However, as the magnetic field increased and the ions transitioned from flowing in the direction of gravity to the direction of the magnetic field, a second wave emerged and two distinct waves were observed to simultaneously propagate, one in the direction of gravity and one in the direction of the magnetic field. As the magnetic field was further increased, the wave that propagated in the direction of gravity was suppressed and the wave was only observed to propagate in the direction of the applied magnetic field. We also observe that the speed and the kinetic temperature of the dust for the mode that propagated in the direction of gravity decreased with increasing magnetic field while the speed and the kinetic temperature of the dust for the mode that propagated in the direction of the magnetic field increased with increasing magnetic field. These measurements suggest that an ion-dust streaming instability is at least partially responsible for the high temperatures that have previously been observed in dusty plasmas when the dust acoustic wave is present.

Williams, J. D. (ORCID:000000025199707X)↗

Properties of Nb3Sn films fabricated by magnetron sputtering from a single target

Superconducting Nb3Sn films were fabricated on sapphire and fine grain Nb substrates by magnetron sputtering from a single stoichiometric Nb3Sn target. The structural, morphological and superconducting properties of the films annealed for 24 h at temperatures of 800-1000 {\deg}C were investigated. The effect of the annealing time at 1000 {\deg}C was examined for 1, 12, and 24 h. The film properties were characterized by X-ray diffraction, scanning electron microscopy, atomic force microscopy, energy dispersive X-ray spectroscopy, and Raman spectroscopy. The DC superconducting properties of the films were characterized by a four-point probe measurement down to cryogenic temperatures. The RF surface resistance of films was measured over a temperature range of 6-23 K using a 7.4 GHz sapphire-loaded Nb cavity. As-deposited Nb3Sn films on sapphire had a superconducting critical temperature of 17.21 K, which improved to 17.83 K when the film was annealed at 800 {\deg}C for 24 h. For the films annealed at 1000 {\deg}C, the surface Sn content was reduced to ~11.3 % for an annealing time of 12 h and to ~4.1 % for an annealing time of 24 h. The Raman spectra of the films confirmed the microstructural evolution after annealing. The RF superconducting critical temperature of the as-deposited Nb3Sn films on Nb was 16.02 K, which increased to 17.44 K when the film was annealed at 800 {\deg}C for 24 h.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Dataset for 'Ombadi, M. & Varadharajan, C. (2022). Urbanization and aridity mediate distinct salinity response to floods in rivers and streams across the Contiguous United States, Water Research'

This package contains data sets and code used to obtain the results in Ombadi, M., & Varadharajan, C. (2022). Urbanization and aridity mediate distinct salinity response to floods in rivers and streams across the Contiguous United States. Water Research, 118664. The folder "data" contains 259 .csv files, each of which has daily time series of concurrent streamflow (Q) and specific conductance (SC) for each of the sites used in this study originally downloaded from the USGS National Water Information System (NWIS; USGS, 2016). The number of data points in each of the files is at least 3650 (i.e. 10 years of daily measurements). The folder "RF_single_data" contains 259 .csv files, each of which include data used to train and test the Random Forest models at individual sites for predicting SC during days of floods. The folder "RF_regional_data" contains 3 .csv files, each of which include scaled data compiled from all sites within each climate zone (arid, temperate and wet). "metadata.csv" contains the physical properties of the 259 catchments corresponding to the sites used in this study; this data was extracted from GAGES-II dataset (Falcone et al., 2010). "RF_implementation.ipynb" is a Jupyter notebook with the code needed to implement the analysis using Random Forest models either for individual sites or for the regional models (for each climate zone). The code utilizes the data in the two folders: "RF_single_data" and "RF_regional_data" and the metadata.csv file.

54 ENVIRONMENTAL SCIENCES↗

Microwave microscope studies of trapped vortex dynamics in superconductors

Trapped vortices in superconductors introduce residual resistance in superconducting radio-frequency (SRF) cavities and disrupt the operation of superconducting quantum and digital electronic circuits. Understanding the detailed dynamics of trapped vortices under oscillating magnetic fields is essential for advancing these technologies. We have developed a near-field magnetic microwave microscope to study the dynamics of a limited number of trapped vortices under the probe when stimulated by a localized rf magnetic field. By measuring the local second-harmonic response (𝑃 2⁢f ) at subfemto-Watt levels, we isolate signals exclusively arising from trapped vortices, excluding contributions from surface defects and Meissner screening currents. Toy models of niobium superconductor hosting vortex pinning sites are introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe/sample interaction to better understand the measured second-harmonic response. The simulation results demonstrate that the second-harmonic response of trapped vortex motion under a localized rf magnetic field shares key features with the experimental data. Here, this measurement technique provides access to vortex dynamics at the micrometer scale, such as depinning events and spatially resolved pinning properties, as demonstrated in measurements on a niobium film with an antidot flux pinning array.

43 PARTICLE ACCELERATORS↗

Toward Emittance Measurements at 11.7 GHz Short-Pulse High-Gradient RF Gun

A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.

43 PARTICLE ACCELERATORS↗

Methods of controllable interstitial oxygen doping in niobium

A method for vacuum heat treating Nb, such as is used in superconducting radio frequency cavities, to engineer the interstitial oxygen profile with depth into the surface to conveniently optimize the low-temperature rf surface resistance of the material. An example application is heating of 1.3 GHz accelerating structures between 250-400° C. to achieve a very high quality factor of 5×1010 at 2.0 K. With data supplied by secondary ion mass spectrometry measurements, application of oxide decomposition and oxygen diffusion theory was applied to quantify previously unknown parameters crucial in achieving the oxygen alloy concentration profiles required to optimize the rf surface resistance. RF measurements of vacuum heat treated Nb superconducting radio frequency cavities confirmed the minimized surface resistance (higher Q0) previously expected only from 800° C. diffusive alloying with nitrogen.

Palczewski, Ari D.↗

Nonlocal subpicosecond delay metrology using spectral quantum interference

Precise knowledge of position and timing information is critical to support elementary protocols such as entanglement swapping on quantum networks. While approaches have been devised to use quantum light for such metrology, they largely rely on time-of-flight (ToF) measurements with single-photon detectors and, therefore, are limited to picosecond-scale resolution owing to detector jitter. In this work, we demonstrate an approach to distributed sensing that leverages phase modulation to map changes in the spectral phase to coincidence probability, thereby overcoming the limits imposed by single-photon detection. By extracting information about the joint biphoton phase, we measure a generalized delay—the difference in signal–idler arrival, relative to local radio frequency (RF) phase modulation. For nonlocal ranging measurements, we achieve (2$σ$) precision of ±0.04 ps and for measurements of the relative RF phase, (2$σ$) precision of ±0.7°. We complement this fine timing information with ToF data from single-photon time-tagging to demonstrate absolute measurement of time delay. By relying on off-the-shelf telecommunications equipment and standard quantum resources, this approach has the potential to reduce overhead in practical quantum networks.

42 ENGINEERING↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

NDSE Static Series V & VI Test Results

The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.