Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dependence of the Performance of the Long Pulse RF Driven Negative Ion Source on the Magnetic Filter Field

In the long pulse RF source the plasma drift caused by the magnetic filter field leads to different plasma parameters close to the top and bottom halves of the plasma. In order to investigate the effect of the plasma density on the extracted currents, the bottom grid halve was covered and the direction of the drift was converted by changing the polarity of the magnets. The asymmetry of the plasma density was measured by H{sub {beta}} spectroscopy. By biasing the plasma grid the asymmetry could be enlarged, but the current of co-extracted electrons could be minimized in a similar way for both polarities. The extracted currents of H{sup -} ions as well as of the electrons, however, depend only weakly on the direction of the drift i. e. on the plasma densities. The results indicate that the source performance is determined to a greater degree by the plasma sheath close to the plasma grid which is not yet accessible by diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

One-dimensional ion-beam figuring for grazing-incidence reflective optics

One-dimensional ion-beam figuring (1D-IBF) can improve grazing-incidence reflective optics, such as Kirkpatrick–Baez mirrors. 1D-IBF requires only one motion degree of freedom, which reduces equipment complexity, resulting in compact and low-cost IBF instrumentation. Furthermore, 1D-IBF is easy to integrate into a single vacuum system with other fabrication processes, such as a thin-film deposition. The NSLS-II Optical Metrology and Fabrication Group has recently integrated the 1D-IBF function into an existing thin-film deposition system by adding an RF ion source to the system. Using a rectangular grid, a 1D removal function needed to perform 1D-IBF has been produced. In this paper, demonstration experiments of the 1D-IBF process are presented on one spherical and two plane samples. The final residual errors on both plane samples are less than 1 nm r.m.s. In conclusion, the surface error on the spherical sample has been successfully reduced by a factor of 12. The results show that the 1D-IBF method is an effective method to process high-precision 1D synchrotron optics.

ion beam figuring↗

Final Technical Report for the ProNova Solutions contribution to: Compact, low-cost, light-weight, superconducting, ironless cyclotrons for hadron radiotherapy

ProNova Solutions, LLC is a collaborator with the primary PI for this project, Dr. Joseph V. Minervini, Head of the Magnets and Cryogenics group at the Massachusetts Institute of Technology, Plasma Science and Fusion Center. The purpose of the grant was to develop the conceptual design for a superconducting ironless synchrocyclotron suitable for hadron therapy. Such a design could ultimately be extended to light ions such as Helium and Carbon which are being studied at centers around the world. The ProNova efforts have been led by Co-PI Laddie Derenchuk and by Joe Matteo, company president. ProNova efforts will be described in this Final Technical Report, other goals and efforts by the MIT group can be referenced in the MIT Final Technical Report. ProNova’s primary goals as defined in the Project Narrative were to “defin[e] specifications necessary to meet the current and future demands of particle therapy based on ProNova’s clinical experience.” In addition, ProNova was to “focus on ion source, RF, vacuum, and mechanical subsystem conceptual designs”. This report will describe ProNova’s contributions to this project.

43 PARTICLE ACCELERATORS↗

A plasma generator utilizing the high intensity ASTROMAG magnets

The magnet configuration for the proposed particle astrophysics magnet facility (ASTROMAG) on the space station includes a cusp magnetic field with an intensity of a few tesla. With these large magnets (or others) located in the outer ionosphere, many quite interesting and unique plasma physics experiments become possible. First there are studies utilizing the magnet alone to examine the supersonic, sub-Alfvenic interaction with the ambient medium; the scale length for the magnet perturbation is approx. 20 m. The magnetic field geometry when combined with the Earth's and their relative motion will give rise to a host of plasma phenomena: ring nulls, x-points, ion-acoustic and lower-hybrid shocks, electron heating (possible shuttle glow without a surface) launching of Alfvenwaves, etc. Second, active experiments are possible for a controlled study of fundamental plasma phenomena. A controlled variable species plasma can be made by using an RF ion source; use of two soft iron rings placed about the line cusp would give an adequate resonance zone (ECH or ICH) and a confining volume suitable for gas efficiency. The emanating plasma can be used to study free expansion of plasma along and across field lines (polar wind), plasma flows around the space platform, turbulent mixing in the wake region, long wavelength spectrum of convecting modes, plasma-dust interactions, etc.

Sullivan, James D.↗

Sputtering of Metals by Mass-Analyzed N2(+) and N(+)

Low-energy sputtering studies were conducted with the help of a specially designed ion accelerator. A high-intensity rf ion source was developed for use in conjunction with electrostatic acceleration and magnetic mass separation of ion beams in the 0 to 8 kev energy range. Beams of N(+) or N2(+) ions have been produced with intensities of 200 to 500 micro-a (approx. 1 sq cm in cross section) and energy half-widths of about 20 ev. The sputtering yields of five metals (Cu, Ni, Fe, Mo, and W) were obtained as a function of energy (0-8 kev), bombarding ion (N(+) and N2(+)), and angle of incidence (normal and 450). Results are presented and some of their theoretical implications are discussed.

Bader, Michel↗

Electronic Power System Application of Diamond-Like Carbon Films

A prototype manufacturing technology for producing high volume efficiency and high energy density diamond-like carbon (DLC) capacitors has been developed. Unique dual ion-beam deposition and web-handling systems have been designed and constructed to deposit high quality DLC films simultaneously on both sides of capacitor grade aluminum foil and aluminum-coated polymer films. An optimized process, using inductively coupled RF ion sources, has been used to synthesize electrically robust DLC films. DLC films are amorphous and highly flexible, making them suitable for the production of wound capacitors. DLC capacitors are reliable and stable over a wide range of AC frequencies from 20 Hz to 1 MHz, and over a temperature range from .500 C to 3000 C. The compact DLC capacitors offer at least a 50% decrease in weight and volume and a greater than 50% increase in temperature handling capability over equal value capacitors built with existing technologies. The DLC capacitors will be suitable for high temperature, high voltage, pulsed power and filter applications.

Wu, Richard L. C.↗

Integrating a Traveling Wave Tube into an AECR-U ion source

An RF system of 500W - 10.75 to 12.75 GHz was designed and integrated into the Advanced Electron Cyclotron Resonance - Upgrade (AECR-U) ion source of the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The AECR-U produces ion beams for the Cyclotron giving large flexibility of ion species and charge states. The broadband frequency of a Traveling Wave Tube (TWT) allows modifying the volume that couples and heats the plasma. The TWT system design and integration with the AECR-U ion source and results from commissioning are presented.

43 PARTICLE ACCELERATORS↗

Operation of RF driven negative ion source in a pure-hydrogen mode

The production of negative hydrogen ions in the radio-frequency driven long-pulsed source with external antenna is studied. RF drivers with various geometry of external antenna, Faraday shield and magnets at the rear flange were examined. H- beam extraction through the single emission aperture was performed in the source pure-hydrogen mode with no external seed of alkali additives. H- beam with ion emission current density up to 5 mA/cm{sup 2} and energy up to 75 keV was regularly obtained in the 1 s pulses of the pure-hydrogen mode. The regular temporal increase of H- ion production due to deposition of impurities on the plasma grid surface was recorded. The H- emission current density increased up to 9 mA/cm{sup 2} in this case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pre-conditioning procedure suitable for internal-RF-antenna of J-PARC RF-driven H{sup −} ion source

The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about 1 yr. By the world brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. Although no internal-RF-antenna failure, except for the once caused by an excess cesium due to a misoperation, occurred in the operation, many antennas failed in pre-conditionings for the first hundred days. The antenna failure rate was drastically decreased by using an antenna with coating thicker than a standard value and the pre-conditioning procedure repeating 15 min 25 kW RF-power operation and impurity-gas evacuation a few times, before the full power (50 kW) operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A revisit to self-excited push pull vacuum tube radio frequency oscillator for ion sources and power measurements

Self-excited push-pull vacuum tube oscillator is one of the most commonly used oscillators in radio frequency (RF)-ion plasma sources for generation of ions using radio frequency. However, in spite of its fundamental role in the process of plasma formation, the working and operational characteristics are the most frequently skip part in the descriptions of RF ion sources in literatures. A more detailed treatment is given in the present work on the RF oscillator alone using twin beam power tetrodes 829B and GI30. The circuit operates at 102 MHz, and the oscillation conditions, stability in frequency, and RF output power are studied and analyzed. A modified form of photometric method and RF peak voltage detection method are employed to study the variation of the oscillator output power with plate voltage. The power curves obtained from these measurements are quadratic in nature and increase with increase in plate voltage. However, the RF output power as measured by photometric methods is always less than the value calculated from peak voltage measurements. This difference is due to the fact that the filament coil of the ordinary light bulb used as load/detector in photometric method is not a perfect inductor. The effect of inductive reactance on power transfer to load was further investigated and a technique is developed to estimate the amount of power correction needed in the photometric measurement result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the ELISE test facility

The test facility ELISE, equipped with a large radio frequency (RF) driven ion source (1×0.9 m2) of half the size of the ion source for the ITER neutral beam injection (NBI) system, is operational since beginning of 2013. The first experimental campaign was dedicated to a thorough qualification of the test facility and its diagnostic tools at low RF power (80 kW in total, i.e. 20 kW per driver) in volume operation, i.e. operation without cesium, where the negative hydrogen ion production is done in the plasma volume only. This paper reports on the main results of the second and third experimental campaigns, where Cs was inserted in the ion source for an enhancement of the negative ion production by the surface process. The second experimental campaign was done still with low RF power, both for hydrogen and deuterium, with pulse lengths of up to 500 s. The results of this campaign are rather encouraging, especially in hydrogen, where large current densities with respect to the low RF power could be achieved at a ratio of co-extracted electrons to extracted ions of 0.5-0.6 at the relevant source pressure of 0.3 Pa. Similar large extracted ion currents could be achieved also in deuterium, but with larger amounts of co-extracted electrons. The required ratio of co-extracted electrons to extracted ions of one could be achieved only in short pulses. The third experimental campaign aimed then for approaching the required ITER NBI parameters with respect to the ion and electron extracted currents, both for hydrogen and deuterium, by increasing the RF power with short pulses, i.e. beam-on times of up to 10 s and RF-on time up to 20 s. Current densities near the ITER NBI requirements could be achieved in hydrogen at a ratio of co-extracted electrons to extracted ions of 0.5-0.6 at the relevant source pressure of 0.3 Pa. As it was the case for the low RF operation, the required filter field was significantly lower than expected from the experience with the small prototype RF source. Similar large extracted ion currents could be achieved also in deuterium, but with larger amounts of co-extracted electrons; the main problem in deuterium operation are the non-stable currents of the co-extracted electrons, most probably caused by the high dynamic of the Cs redistribution in the system. The reasons for this larger instability are still under investigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fine-tuning to minimize emittances of J-PARC RF-driven H{sup −} ion source

The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about one year. By the world’s brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. In order to minimize the transverse emittances, the rod-filter-field (RFF) was optimized by changing the triple-gap-lengths of each of pairing five piece rod-filter-magnets. The larger emittance degradation seems to be caused by impurity-gases than the RFF. The smaller beam-hole-diameter of the extraction electrode caused the more than expected improvements on not only the emittances but also the peak beam intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ways to improve the efficiency and reliability of radio frequency driven negative ion sources for fusion

Large RF driven negative hydrogen ion sources are being developed at IPP Garching for the future neutral beam injection system of ITER. The overall power efficiency of these sources is low, because for the RF power supply self-excited generators are utilized and the plasma is generated in small cylindrical sources (“drivers”) and expands into the source main volume. At IPP experiments to reduce the primary power and the RF power required for the plasma production are performed in two ways: The oscillator generator of the prototype source has been replaced by a transistorized RF transmitter and two alternative driver concepts, a spiral coil, in which the field is concentrated by ferrites, which omits the losses by plasma expansion and a helicon source are being tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rod-filter-field optimization of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second-stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). Although rod-filter-field (RFF) is indispensable and one of the most beam performance dominative parameters for the RF-driven H{sup −} ion source with the internal-antenna, the procedure to optimize it is not established. In order to optimize the RFF and establish the procedure, the beam performances of the J-PARC source with various types of rod-filter-magnets (RFMs) were measured. By changing RFM’s gap length and gap number inside of the region projecting the antenna inner-diameter along the beam axis, the dependence of the H{sup −} ion beam intensity on the net 2MHz-RF power was optimized. Furthermore, the fine-tuning of RFM’s cross-section (magnetmotive force) was indispensable for easy operation with the temperature (T{sub PE}) of the plasma electrode (PE) lower than 70°C, which minimizes the transverse emittances. The 5% reduction of RFM’s cross-section decreased the time-constant to recover the cesium effects after an slightly excessive cesiation on the PE from several 10 minutes to several minutes for T{sub PE} around 60°C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the RF-driven H{sup −} ion source for J-PARC linac

For the upgrade of the Japan Proton Accelerator Research Complex linac beam current, a cesiated RF-driven negative hydrogen ion source was installed during the 2014 summer shutdown period, with subsequent operations commencing on September 29, 2014. The ion source has been successfully operating with a beam current and duty factor of 33 mA and 1.25% (500 μs and 25 Hz), respectively. The result of recent beam operation has demonstrated that the ion source is capable of continuous operation for approximately 1100 h. The spark rate at the beam extractor was observed to be at a frequency of less than once a day, which is an acceptable level for user operation. Although an antenna failure occurred during operation on October 26, 2014, no subsequent serious issues have occurred since then.

43 PARTICLE ACCELERATORS↗