Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF superconductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automated Hydroforming of Seamless Superconducting RF Cavity

We are studying the possibility of automated hydroforming process for seamless superconducting RF cavities. Preliminary hydroforming tests of three-cell cavities from seamless tubes made of C1020 copper have been performed. The key point of an automated forming is to monitor and strictly control some parameters such as operation time, internal pressure and material displacements. Especially, it is necessary for our studies to be able to control axial and radial deformation independently. We plan to perform the forming in two stages to increase the reliability of successful forming. In the first stage hydroforming by using intermediate constraint dies, three-cell cavities were successfully formed in less than 1 minute. In parallel, we did elongation tests on cavity-quality niobium and confirmed that it is possible to achieve an elongation of >64% in 2 stages that is required for our forming of 1.3 GHz cavities.

36 MATERIALS SCIENCE↗

Superconducting RF materials other than bulk niobium: a review

For the last five decades, bulk niobium (Nb) has been the material of choice for Superconducting RF (SRF) cavity applications. Thin film alternatives such as Nb and other higher-Tc materials, mainly Nb compounds and A15 compounds, have been investigated with moderate effort in the past. In recent years, RF cavity performance has approached the theoretical limit for bulk Nb. For further improvement of RF cavity performance for future accelerator projects, research interest is renewed towards alternatives to bulk Nb. Institutions around the world are now investing renewed efforts in the investigation of Nb thin films and superconductors with higher transition temperature Tc for application to SRF cavities. Our paper gives an overview of the results obtained so far and challenges encountered for Nb films as well as other materials, such as Nb compounds, A15 compounds, MgB2, and oxypnictides, for SRF cavity applications. An interesting alternative using a Superconductor-Insulator- Superconductor multilayer approach has been recently proposed to delay the vortex penetration in Nb surfaces. This could potentially lead to further improvement in RF cavities performance using the benefit of the higher critical field Hc of higher-Tc superconductors without being limited with their lower Hc1.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of an Injection Locked Magnetron to Drive a Superconducting RF Cavity

The use of an injection locked CW magnetron to drive a 2.45 GHz superconducting RF cavity has been successfully demonstrated. With a locking power less than -27 dB with respect to the output and with a phase control system acting on the locking signal, cavity phase was accurately controlled for hours at a time without loss of lock whilst suppressing microphonics. The phase control accuracy achieved was 0.8 deg. r.m.s. The main contributing disturbance limiting ultimate phase control was power supply ripple from the low specification switch mode power supply used for the experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Microscopic Materials Limitations of Superconducting RF Cavities

The high-field performance of SRF cavities is often limited by breakdown events below the intrinsic limiting surface fields of Nb, and there is abundant evidence that these breakdown events are localized in space inside the cavity. Also, there is a lack of detailed understanding of the causal links between surface treatments and ultimate RF performance at low temperatures. An understanding of these links would provide a clear roadmap for improvement of SRF cavity performance, and establish a cause-and-effect ‘RF materials science’ of Nb. We propose two specific microscopic approaches to addressing these issues. First is a spatially-resolved local microwave-microscope probe that operates at SRF frequencies and temperatures to discover the microscopic origins of breakdown, and produce quantitative measurements of RF critical fields of coatings and films. Second, RF Laser Scanning Microscopy (LSM) has allowed visualization of RF current flow and sources of nonlinear RF response in superconducting devices with micro-meter spatial resolution. The LSM will be used in conjunction with surface preparation and characterization techniques to create definitive links between physical and chemical processing steps and ultimate cryogenic microwave performance. We propose to develop RF laser scanning microscopy of small-sample Nb pieces to establish surface-processing / RF performance relations through measurement of RF current distributions on micron-length scales and low temperatures.

36 MATERIALS SCIENCE↗

Commissioning of an Improved Superconducting RF Photo Injector at ELBE

In order to produce high-brightness electron beams in a superconducting RF photo injector, the most important point is to reach a high acceleration field in the cavity. For this reason two new 3.5-cell niobium cavities were fabricated, chemically treated and cleaned in collaboration with Jlab. The first of these two cavities was shipped to HZDR and assembled in a new cryomodule. This new gun (SRF Gun II) was installed in the ELBE accelerator hall in May 2014 and replaces the previous SRF Gun I. Beside the new cavity the ELBE SRF gun II differs from the previous gun by the integration of a superconducting solenoid. The paper presents the results of the first test run with a Cu photocathode.

Teichert, J.↗

Development of fundamental power coupler for high-current superconducting RF cavity

Brookhaven National Laboratory took a project of developing a 704 MHz five-cell superconducting RF cavity for high-current linacs, including Energy Recovery Linac (ERL) for planned electron-hadron collider eRHIC. The cavity will be fed by a high-power RF amplifier using a coaxial Fundamental Power Coupler (FPC), which delivers 20 kW of CW RF power to the cavity. The design of FPC is one of the important aspects as one has to take into account the heat losses dissipated on the surface of the conductor by RF fields along with that of the static heat load. Using a simple simulation model we show the temperature profile and the heat load dissipated along the coupler length. To minimize the heat load on FPC near the cavity end, a thermal intercept is required at an appropriate location on FPC. A 10 K intercept was chosen and its location optimized with our simulation code. The requirement on the helium gas flow rate for the effective heat removal from the thermal intercept is also discussed.

43 PARTICLE ACCELERATORS↗

Observations of Long-Range and Short-Range Wakefield Effects on Electron-Beam Dynamics in TESLA-Type Superconducting RF

The assessments of long-range and short-range wakefield effects in TESLA-type superconducting rf cavities at the Fermilab Accelerator Science and Technology (FAST) Facility are described. A dipolar higher-order mode (HOM) of one cavity is shown to be in near resonance with the 3-MHz micropulse repetition frequency harmonic resulting in a clear sub-macropulse centroid oscillation of 100 kHz. In the short-range wakefield measurements, a head-tail transverse kick of ~100 µm is seen in the streak camera images with 500 pC/b and offsets of ~2 mm. A numerical model for the TESLA-type cavity is consistent with these latter results.

43 PARTICLE ACCELERATORS↗

Cerenkov Radiator Driven by a Superconducting RF Electron Gun

The Naval Postgraduate School (NPS), Niowave, Inc., and Boeing have recently demonstrated operation of the first superconducting RF electron gun based on a quarter wave resonator structure. In preliminary tests, this gun has produced 10 ps long bunches with charge in excess of 78 pC, and with beam energy up to 396 keV. Initial testing occurred at Niowave's Lansing, MI facility, but the gun and diagnostic beam line are planned for installation in California in the near future. The design of the diagnostic beam line is conducive to the addition of a Cerenkov radiator without interfering with other beam line operations. Design and simulations of a Cerenkov radiator, consisting of a dielectric lined waveguide will be presented. The dispersion relation for the structure is determined and the beam interaction is studied using numerical simulations. The characteristics of the microwave radiation produced in both the short and long bunch regimes will be presented.

43 PARTICLE ACCELERATORS↗

Novel Magnetron Operation and Control Methods for Superconducting RF Accelerators

High power magnetrons designed and optimized for industrial heating, being injection-locked, have been suggested to power superconducting RF cavities for accelerators due to lower cost and higher efficiency. However, standard operation methods do not provide high efficiency with wideband control suppressing microphonics. We have developed and experimentally verified novel methods of operating and controlling the magnetron that provide stable RF generation with higher efficiency and lower noise than other RF sources. By our method the magnetrons operate with the anode voltage notably lower than the self-excitation threshold improving its performance. This is also a promising way to increase tube reliability and longevity. A magnetron operating with the anode voltage lower than the self-excitation threshold, in so-called stimulated coherent generation mode has special advantage for pulse operation with a gated injection-locking signal. This eliminates the need for expensive pulsed HV modulators and additionally increases the magnetron RF source efficiency due to absence of losses in HV modulators.

43 PARTICLE ACCELERATORS↗

Mirror smooth superconducting RF cavities by mechanical polishing with minimal acid use

A new mechanical technique for polishing the inside surface of niobium superconducting RF (SRF) cavities has been developed. Mirror-like finishes, the smoothest observed in cavities so far, were produced after fine polishing, with < 15 nm RMS roughness over 1 mm{sup 2} scan area. This is an order of magnitude less than the typical roughness produced by electropolishing. The processing equipment has advantages of modest installed and operating costs, simple associated technology, and no large quantities of acutely toxic chemicals or special handling procedures. Cavity quality factors above 10{sup 10} were maintained well above the 35 MV m{sup -1} benchmark for electropolished cavities, and this was achieved with an intermediate finish not as smooth as the final polish. Repair of a weld defect, which is intrinsic to this process, was also demonstrated. These transformational aspects could enable a new SRF cavity processing paradigm for future large scale particle accelerators such as the International Linear Collider.

43 PARTICLE ACCELERATORS↗

Mirror smooth superconducting RF cavities by mechanical polishing with minimal acid use

A new mechanical technique for polishing the inside surface of niobium superconducting RF (SRF) cavities has been developed. Mirror-like finishes, the smoothest observed in cavities so far, were produced after fine polishing, with < 15 nm RMS roughness over 1 mm2 scan area. This is an order of magnitude less than the typical roughness produced by electropolishing. The processing equipment has advantages of modest installed and operating costs, simple associated technology, and no large quantities of acutely toxic chemicals or special handling procedures. Cavity quality factors above 10 10 were maintained well above the 35 MV m-1 benchmark for electropolished cavities, and this was achieved with an intermediate finish not as smooth as the final polish. Repair of a weld defect, which is intrinsic to this process, was also demonstrated. These transformational aspects could enable a new SRF cavity processing paradigm for future large scale particle accelerators such as the International Linear Collider.

43 PARTICLE ACCELERATORS↗

Shielding Studies for Superconducting RF Cavities at Fermilab

A semi-empirical method that allows us to predict intensity of generated field emission in superconducting RF cavities is described. Spatial, angular and energy distributions of the generated radiation are calculated with the FISHPACT code. The Monte Carlo code MARS15 is used for modeling the radiation transport in matter. A comparison with dose rate measurements performed in the Fermilab Vertical Test Facility for ILC-type cavities with accelerating gradients up to 35 MV/m is presented as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Superconducting RF Photoinjector at ELBE--First Operational Experience

An RF photoinjector with a superconducting cavity (SRF gun) for installation at the Radiation Source ELBE was developed within a collaboration of BESSY, DESY, FZD, and MBI. This new and promising injector type allows CW operation and has the potential for the production of high-brightness electron beams. The gun cryostat, the electron diagnostic beamline, and the driver laser with optical beamline were installed. In November 2007 the first beam was produced. Results of the beam parameter measurements with Cs{sub 2}Te photo cathodes are presented.

43 PARTICLE ACCELERATORS↗

Insight into bulk niobium superconducting RF cavities performances by tunneling spectroscopy

Point contact tunneling (PCT) spectroscopy measurements are reported over wide areas of cm-sized cut outs from niobium superconducting RF cavities. A comparison is made between a high-quality, conventionally processed (CP) cavity with a high field Q drop for acceleration field E $>$ 20 MV/m and a nitrogen doped (N-doped) cavity that exhibits an increasing Q up to fields approaching 15 MV/m. The CP cavity displays hot spot regions at high RF fields where Q-drop occurs as well as unaffected regions (cold spots). PCT data on cold spots reveals a near ideal BCS density of states (DOS) with gap parameters, $\Delta$ as high as 1.62 meV, that are among the highest values ever reported for Nb. Hot spot regions exhibit a wide distribution of gap values down to $\Delta \sim$ 1.0 meV and DOS broadening characterized by a relatively large value of pair-breaking rate, $\Gamma$, indicating surface regions of significantly reduced superconductivity. In addition, hot spots commonly exhibit Kondo tunneling peaks indicative of surface magnetic moments attributed to a defective oxide. N-doped cavities reveal a more homoegeneous gap distribution centered at $\Delta \sim$ 1.5 meV and relatively small values of $\Gamma/\Delta$. The absence of regions of significantly reduced superconductivity indicates that the N interstitials are playing an important role in preventing the formation of hydride phases and other macroscopic defects which might otherwise severely affect the local, surface superconductivity that lead to hot spot formation. The N-doped cavities also display a significantly improved surface oxide, i.e., increased thickness and tunnel barrier height, compared to CP cavities. These results help explain the improved performance of N-doped cavities and give insights into the origin of the initial increasing Q with RF amplitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision vector control of a superconducting RF cavity driven by an injection locked magnetron

The technique presented in this paper enables the regulation of both radio frequency amplitude and phase in narrow band devices such as a Superconducting RF (SRF) cavity driven by constant power output devices i.e. magnetrons [1]. The ability to use low cost high efficiency magnetrons for accelerator RF power systems, with tight vector regulation, presents a substantial cost savings in both construction and operating costs - compared to current RF power system technology. An operating CW system at 2.45 GHz has been experimentally developed. Vector control of an injection locked magnetron has been extensively tested and characterized with a SRF cavity as the load. Amplitude dynamic range of 30 dB, amplitude stability of 0.3% r.m.s, and phase stability of 0.26 degrees r.m.s. has been demonstrated.

43 PARTICLE ACCELERATORS↗

Direct Observations of Sub-micropulse Electron-beam Effects from Short-range Wakefields in TESLA-type Superconducting RF Cavities

The preservation of the low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (FEL) and the under construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range and short-range wakefields (SRW)*. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique two-cavity configuration after the photocathode rf gun. We used optical transition radiation (OTR) imaging with a UV-visible synchroscan streak camera to display sub-micropulse y-t effects in the 41-MeV beam. The head-tail transverse kicks within the 11-ps-long micropulses were observed at the 100-micron level for steering off-axis in one cavity and several 100 microns for two cavities. Since the SRW kick angles go inversely with energy, these results may inform the commissioning plans of the LCLS-II injector where beam will be injected at ~1 MeV into a cryomodule.

43 PARTICLE ACCELERATORS↗