Search NASA⌕ Search

SEARCH · Search NASA

Results for “RVS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Gaussian Process Regression Reveals No Evidence for Planets Orbiting Kapteyn’s Star

Radial–velocity (RV) planet searches are often polluted by signals caused by gas motion at the star’s surface. Stellar activity can mimic or mask changes in the RVs caused by orbiting planets, resulting in false positives or missed detections. Here we use Gaussian process regression to disentangle the contradictory reports of planets versus rotation artifacts from Kapteyn’s star. To model rotation, we use joint quasiperiodic kernels for the RV and Hα signals, requiring that their periods and correlation timescales be the same. We find that the rotation period of Kapteyn’s star is 125 days, while the characteristic active-region lifetime is 694 days. Adding a planet to the RV model produces a best-fit orbital period of 100 yr, or 10 times the observing time baseline, indicating that the observed RVs are best explained by star rotation only. We also find no significant periodic signals in residual RV data sets constructed by subtracting off realizations of the best-fit rotation model and conclude that both previously reported “planets” are artifacts of the star’s rotation and activity. Our results highlight the pitfalls of using sinusoids to model quasiperiodic rotation signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On Orbit Measurement of Response vs. Scan Angle for the Infrared Bands on TRMM/VIRS

The Visible and Infrared Scanner on the Tropical Rainfall Measuring Mission (TRMM/VIRS) is a whiskbroom imaging radiometer with two reflected solar bands and three emissive infrared bands. All five detectors are on a single cooled focal plane. This configuration necessitated the use of a paddlewheel scan mirror to avoid the effects of focal plane rotation that arise when using a scan mirror that is inclined to its axis of rotation. System radiometric requirements led to the need for protected silver as the mirror surface. Unfortunately, the SiO(x) coatings currently used to protect silver from oxidation introduce a change in reflectance with angle of incidence (AOI). This AOI dependence results in a modulation of system level response with scan angle. Measurement of system response vs. scan angle (RVS) was not difficult for the VIRS reflected solar bands, but attaining the required accuracy for the IR bands in the laboratory was not possible without a large vacuum chamber and a considerable amount of custom designed testing apparatus. Therefore, the decision was made to conduct the measurement on-orbit. On three separate occasions, the TRMM spacecraft was rotated about its pitch axis and, after the nadir view passed over the Earth's limb, the VIRS performed several thousand scans while viewing deep space. The resulting data has been analyzed and the RVS curves generated for the three IR bands are being used in the VIRS radiometric calibration algorithm. This, to our knowledge, the first time this measurement has been made on-orbit. Similar measurements are planned for the EOS-AM and EOS-PM MODIS sensors and are being considered for several systems under development. The VIRS on-orbit results will be compared to VIRS and MODIS system level laboratory measurements, MODIS scan mirror witness sample measurements and modeled data.

Barnes, William L.↗

Sensor On-orbit Calibration and Characterization Using Spacecraft Maneuvers

Spacecraft flight operations often require activities that involve different kinds of maneuvers for orbital adjustments (pitch, yaw, and roll). Different maneuvers, when properly planned and scheduled, can also be applied to support and/or to perform on-board sensor calibration and characterization. This paper uses MODIS (Moderate Resolution Imaging Spectroradiometer) as an example to illustrate applications of spacecraft maneuvers for Earth-observing sensors on-orbit calibration and characterization. MODIS is one of the key instruments for NASA's Earth Observing System (EOS) currently operated on-board the EOS Terra and Aqua spacecraft launched in December 1999 and May 2002, respectively. Since their launch, both Terra and Aqua spacecraft have made a number of maneuvers, specially the yaw and roll maneuvers, to support the MODIS on-orbit calibration and characterization. For both Terra and Aqua MODIS, near-monthly spacecraft roll maneuvers are executed for lunar observations. These maneuvers are carefully scheduled so that the lunar phase angles are nearly identical for each sensor's lunar observations. The lunar observations are used to track MODIS reflective solar bands (RSB) calibration stability and to inter-compare Terra and Aqua MODIS RSB calibration consistency. To date, two sets of yaw maneuvers (each consists of two series of 8 consecutive yaws) by the Terra spacecraft and one set by the Aqua spacecraft have been performed to validate MODIS solar diffuser (SD) bi-directional reflectance factor (BRF) and to derive SD screen transmission. Terra spacecraft pitch maneuvers, first made on March 26, 2003 and the second on April 14, 2003 (with the Moon in the spacecraft nadir view), have been applied to characterize MODIS thermal emissive bands (TEB) response versus scan angle (RVS). This is particularly important since the pre-launch TEB RSV measurements made by the sensor vendor were not successful. Terra MODIS TEB RVS obtained from pitch maneuvers have been used in the current LIB calibration algorithm. Lunq observations from pitch maneuvers also provided information to cross-calibrate MODIS with other sensors (MISR and ASTER) on the same platform. We will provide a summary of MODIS maneuver activities and their applications for MODIS calibration and characterization. The results and lessons learned discussed in this paper from MODIS maneuver activities will provide useful insights into future spacecraft and sensor operation.

Xiong, X.↗

Characterization of MODIS VIS/NIR Spectral Band Detector-to-Detector Difference

MODIS has 36 spectral bands with wavelengths in the visible (VIS), near-infrared (NIR), shortwave infrared (SWTR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). It makes observations at three nadir spatial resolutions: 0,25km for bands 1-2 with 40 detectors per band, 0.5km for bands 3-7 with 20 detectors per band, and 1km for bands 8-36 with 10 detectors per band. The VIS, NIR, and S\VIR spectral bands are the reflective solar bands (RSB), which are calibrated on-orbit by a solar diffuser (SD). In addition, MODIS lunar observations are used to track the RSB calibration stability. In this study, we examine detector-to-detector calibration difference for the VIStNIR spectral bands using the SD and lunar observations. The results will be compared with an independent analysis with additional information, such as polarization correction, derived from standard ocean color data products. The current MODIS RSB calibration approach only carries a band-averaged RVS (response versus scan angle) correction. The results from this study suggest that a detector-based RVS correction should be used to improve the L1B data quality, especially for several VIS bands in Terra MODIS due to large changes of the scan mirror's optical properties in recent years.

Xiong, X.↗

Voltage Sensors Monitor Harmful Static

A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

Source record↗

Tuning Monotonic Basin Hopping: Improving the Efficiency of Stochastic Search as Applied to Low-Thrust Trajectory Optimization

Trajectory optimization methods using MBH have become well developed during the past decade. An essential component of MBH is a controlled random search through the multi-dimensional space of possible solutions. Historically, the randomness has been generated by drawing RVs from a uniform probability distribution. Here, we investigate the generating the randomness by drawing the RVs from Cauchy and Pareto distributions, chosen because of their characteristic long tails. We demonstrate that using Cauchy distributions (as first suggested by Englander significantly improves MBH performance, and that Pareto distributions provide even greater improvements. Improved performance is defined in terms of efficiency and robustness, where efficiency is finding better solutions in less time, and robustness is efficiency that is undiminished by (a) the boundary conditions and internal constraints of the optimization problem being solved, and (b) by variations in the parameters of the probability distribution. Robustness is important for achieving performance improvements that are not problem specific. In this work we show that the performance improvements are the result of how these long-tailed distributions enable MBH to search the solution space faster and more thoroughly. In developing this explanation, we use the concepts of sub-diffusive, normally-diffusive, and super-diffusive RWs originally developed in the field of statistical physics.

mission design↗

Lessons Learned from the AIRS Pre-Flight Radiometric Calibration

The Atmospheric Infrared Sounder (AIRS) instrument flies on the NASA Aqua satellite and measures the upwelling hyperspectral earth radiance in the spectral range of 3.7-15.4 micron with a nominal ground resolution at nadir of 13.5 km. The AIRS spectra are achieved using a temperature controlled grating spectrometer and HgCdTe infrared linear arrays providing 2378 channels with a nominal spectral resolution of approximately 1200. The AIRS pre-flight tests that impact the radiometric calibration include a full system radiometric response (linearity), polarization response, and response vs scan angle (RVS). We re-derive the AIRS instrument radiometric calibration coefficients from the pre-flight polarization measurements, the response vs scan (RVS) angle tests as well as the linearity tests, and a recent lunar roll test that allowed the AIRS to view the moon. The data and method for deriving the coefficients is discussed in detail and the resulting values compared amongst the different tests. Finally, we examine the residual errors in the reconstruction of the external calibrator blackbody radiances and the efficacy of a new radiometric uncertainty model. Results show the radiometric calibration of AIRS to be excellent and the radiometric uncertainty model does a reasonable job of characterizing the errors.

Sounder↗

SEEDS Direct Imaging of the RV-Detected Companion to V450 Andromedae, and Characterization of the System

We report the direct imaging detection of a low-mass companion to a young, moderately active star V450 And, that was previously identified with the radial velocity (RV) method. The companion was found in high-contrast images obtained with the Subaru Telescope equipped with the HiCIAO camera and AO188 adaptive optics system. From the public ELODIE and SOPHIE archives we extracted available high-resolution spectra and RV measurements, along with RVs from the Lick planet search program. We combined our multi-epoch astrometry with these archival, partially unpublished RVs, and found that the companion is a low-mass star, not a brown dwarf, as previously suggested. We found the best-fitting dynamical masses to be m(sub 1) = 1.141(sup + 0.037, sub - 0.091) and m(sub 2) = 0.279(sup + 0.023, sub - 0.020) solar mass. We also performed spectral analysis of the SOPHIE spectra with the iSpec code. Hipparcos time-series photometry shows a periodicity of P = 5.743 day, which is also seen in the SOPHIE spectra as an RV modulation of the star A. We interpret it as being caused by spots on the stellar surface, and the star to be rotating with the given period. From the rotation and level of activity, we found that the system is 380(sup + 220, sub -100) Myr old, consistent with an isochrone analysis (220 (sup +2120, sub -90) Myr). This work may serve as a test case for future studies of low mass stars, brown dwarfs, and exoplanets by combination of RV and direct imaging data.

direct imaging detection of a low-mass companion↗

Assessment of MODIS On-Orbit Calibration Using a Deep Convective Cloud Technique

The MODerate Resolution Imaging Spectroradiometer (MODIS) sensors onboard Terra and Aqua satellites are calibrated on-orbit with a solar diffuser (SD) for the reflective solar bands (RSB). The MODIS sensors are operating beyond their designed lifetime and hence present a major challenge to maintain the calibration accuracy. The degradation of the onboard SD is tracked by a solar diffuser stability monitor (SDSM) over a wavelength range from 0.41 to 0.94 micrometers. Therefore, any degradation of the SD beyond 0.94 micrometers cannot be captured by the SDSM. The uncharacterized degradation at wavelengths beyond this limit could adversely affect the Level 1B (L1B) product. To reduce the calibration uncertainties caused by the SD degradation, invariant Earth-scene targets are used to monitor and calibrate the MODIS L1B product. The use of deep convective clouds (DCCs) is one such method and particularly significant for the short-wave infrared (SWIR) bands in assessing their long-term calibration stability. In this study, we use the DCC technique to assess the performance of the Terra and Aqua MODIS Collection-6 L1B for RSB 1 3- 7, and 26, with spectral coverage from 0.47 to 2.13 micrometers. Results show relatively stable trends in Terra and Aqua MODIS reflectance for most bands. Careful attention needs to be paid to Aqua band 1, Terra bands 3 and 26 as their trends are larger than 1% during the study time period. We check the feasibility of using the DCC technique to assess the stability in MODIS bands 17-19. The assessment test on response versus scan angle (RVS) calibration shows substantial trend difference for Aqua band 1between different angles of incidence (AOIs). The DCC technique can be used to improve the RVS calibration in the future.

Mu, Qiaozhen↗

MODIS and VIIRS On-Orbit Calibration and Characterization Using Observations from Spacecraft Pitch Maneuvers

Two MODIS instruments (Terra and Aqua) and two VIIRS instruments (S-NPP and JPSS-1) are currently operated inspace, continuously making global earth observations in the spectral range from visible (VIS) to long-wave infrared(LWIR). These observations have enabled a broad range of environmental data records to be generated and distributed insupport of both operational and scientific community. Despite extensive pre-launch calibration and characterizationperformed for both MODIS and VIIRS instruments and routine on-orbit calibration activities carried out using their onboardcalibrators (OBC), various spacecraft maneuvers have also been designed and implemented to further enhance thesensor on-orbit calibration and data quality. This paper focuses on the use of observations made during spacecraft pitchmaneuvers of MODIS and VIIRS in support of their on-orbit characterization of thermal emissive bands (TEB) responseversus scan-angle (RVS). In the case of Terra MODIS, lunar observations made from instrument nadir view duringspacecraft pitch maneuvers are used to compare with that made regularly through instrument space view (SV) port toevaluate on-orbit changes in RVS and band-to-band registration (BBR) for the reflective solar bands (RSB). In additionto results derived from spacecraft pitch maneuvers performed for MODIS and VIIRS, discussion is provided on theadvantages, challenges, and lessons for future considerations and improvements.

Xiong, Xiaoxiong↗

Methods of Earth View Based Calibration of the Response Versus Scan Angle of the MODIS Reflective Solar Bands

The MODIS instruments on the Terra and Aqua spacecraft are cross-track scanning radiometers that view the Earth scene, a space view port, and the on-board calibrators using a two-sided scan mirror. The reflectivity of the scan mirror varies with the angle of the incident light, and changes in this response versus scan angle (RVS) need to be tracked on orbit in order to maintain accurate calibration. In this paper, we review various methods of RVS calibration of the reflective solar bands using pseudo-invariant desert targets and discuss potential advantages and disadvantages for use in future calibration.

Twedt, Kevin A.↗

The MODIS RSB calibration and look-up-table delivery process for Collection 6 and 6.1

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on-board the Aqua and Terra space-craft have provided valuable science data for the last 18 and 20 years, respectively. Each instrument is equipped with 36 spectral bands, 20 of which are reflective solar bands (RSBs). These bands cover a wavelength range of 0.4 – 2.2μm and are calibrated on-orbit using several on-board calibrators (OBCs), such as a solar diffuser (SD)and a solar diffuser stability monitor (SDSM), along with regularly-scheduled lunar observations through the space view (SV) port. The gain (1/m1) and response-verses-scan angle (RVS) are updated on a near-monthly basis and act as the primary look-up-tables (LUTs) for the RSB calibration. A set of separate uncertainty LUTs for each of the RSBs are also delivered regularly and incorporated into the Level 1B (L1B) product to generate a pixel-level Uncertainty Index (UI). In addition to the gain, RVS and uncertainty, there are several other LUTs associated with the reflective bands that are either updated less frequently or remain static. The accuracy of both the forward-predicted and historical RSB LUTs, which are derived by the MODIS Characterization Sup-port Team (MCST), is important in maintaining the quality and accuracy of the L1B and science products.To ensure a timely and accurate LUT update, MCST has established a comprehensive set of procedures. This paper provides an overview of the calibration process, along with the current LUT delivery process for the RSB sin Collection 6 (C6) and Collection 6.1 (C6.1). Improvements to be implemented in future collections are also discussed.

MODIS↗

TOI-431/HIP 26013: a super-Earth and a sub-Neptune transiting a bright, early K dwarf, with a third RV planet

We present the bright (V mag = 9.12), multiplanet system TOI-431, characterized with photometry and radial velocities (RVs). We estimate the stellar rotation period to be 30.5 ± 0.7 d using archival photometry and RVs. Transiting Exoplanet Survey Satellite ( TESS ) objects of Interest (TOI)-431 b is a super-Earth with a period of 0.49 d, a radius of 1.28 ± 0.04 R ⊕ , a mass of 3.07 ± 0.35 M ⊕ , and a density of 8.0 ± 1.0 g cm −3 ; TOI-431 d is a sub-Neptune with a period of 12.46 d, a radius of 3.29 ± 0.09 R ⊕ , a mass of 9.90+1.53 −1.49 M ⊕ , and a density of 1.36 ± 0.25 g cm −3 . We find a third planet, TOI-431 c, in the High Accuracy Radial velocity Planet Searcher RV data, but it is not seen to transit in the TESS light curves. It has an Msin i of 2.83+0.41 −0.34 M ⊕ , and a period of 4.85 d. TOI-431 d likely has an extended atmosphere and is one of the most well-suited TESS discoveries for atmospheric characterization, while the super-Earth TOI-431 b may be a stripped core. These planets straddle the radius gap, presenting an interesting case-study for atmospheric evolution, and TOI-431 b is a prime TESS discovery for the study of rocky planet phase curves.

Ares Osborn↗

Space Shuttle Program Dual Docked Operations

Due to the ever-increasing visiting vehicle traffic to and from the International Space Station (ISS) during mated Orbiter/ISS missions, it became apparent to both the ISS Program (ISSP) and the Space Shuttle program (SSP) that there would arise occasions where a visiting vehicle docking and/or undocking could overlap when the Space Shuttle Orbiter was docked to the ISS, referred to as Dual Docked Operations (DDO). The primary concerns were that plumes from the visiting vehicles would cause contamination, corrosion, and erosion to Space Shuttle surfaces and present a toxicity hazard to ground personnel when processing the Space Shuttle after landing. This potential conflict provided the genesis for evaluating risk mitigations to gain maximum flexibility for managing potential visiting vehicle traffic to and from the ISS and to maximize launch and landing opportunities for all visiting vehicles. The overarching goal of this effort was to assess the viability and readiness of the SSP to protect for DDO on any given mission. To assess the viability of performing DDO, the ISSP delivered plume particle fluence (i.e., number of particles per unit area) and contamination deposition based on the visiting vehicle’s proximity operations to the SSP for evaluation. This paper summarizes the concept definition, studies, and analysis results generated by the SSP, ISSP, and Mission Operations Directorate (MOD) for implementing DDO involving the Orbiter and Russian vehicles (RVs). Discussion and results presented herein represent a generic assessment of the SSP and ISSP integrated safety and technical evaluations of DDO involving the Orbiter and RVs. Mission-specific analysis and operational impacts were conducted flight-by-flight as they arose.

Launch vehicles↗

Using Dome Concordia to Characterize the Long-Term Stability of VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments aboard the Suomi NPP and NOAA-20 spacecraft have successfully provided Earth image products since 2011 and 2017, respectively. Maintaining accurate radiometric calibration and calibration consistency between the two sensors is a necessity for the continued quality of long-term data records. In this work, the use of frequent VIIRS measurements of brightness temperature over the area surrounding Dome Concordia (Dome C), Antarctica (75.1 °S, 123.4°E) to track the long-term stability of its thermal emissive bands (TEB) is presented. The extremely dry, cold, and rarefied atmosphere of the site makes it ideal to track and detect long-term changes in the TEB responses via analysis of near-nadir and off-nadir VIIRS overpasses in reference to the surface temperature measurements provided by an automated weather station (AWS). Multi-year Dome C measurements have been used to assess the stability of the VIIRS response-versus-scan-angle (RVS) of the half-angle-mirror (HAM), derived from prelaunch characterization, and detector differences at multiple scan angles. Also, included in this work is the RVS stability assessments using the Dome C overpasses. The methodology developed via this work will also be applied to the recently launched VIIRS instrument onboard the NOAA-21 satellite (previously JPSS-2) in the future.

Amit Angal↗

MODIS Aqua Reflective Solar Bands Calibration for NASA's R2018 Ocean Color Products

Remote sensing ocean color products have stringent requirements on radiometric calibration stability. To address a calibration deficiency in MODIS Aqua in recent years, the NASA Ocean Biological Processing Group (OBPG) developed a new calibration for the reflective solar bands. Prior to the reprocessing of NASA's ocean color products for 2018 (R2018), the OBPG MODIS products had been based on calibration provided by the MODIS Calibration Support Team (MCST). Several modifications were made to the MCST calibration approach to improve the calibration accuracy for ocean color products. These include: 1) apply 936nm detector normalization to solar diffuser stability monitor (SDSM) data to reduce coherent noise; 2) modeling solar diffuser (SD) degradation wavelength dependency to determine SD degradation in near-infrared and shortwave infrared wavelength; 3) detector gains are computed using SD screen-closed data to better match ocean radiance levels in all bands; 4) a simple atmospheric correction is performed to reduce bidirectional reflectance distribution function (BRDF) effects in desert trends; 5) modulated relative spectral response (RSR) impact on ocean data is estimated and used to adjust the calibration coefficients. 6) smoothing is used to characterize the temporal change in calibration, and response versus scan angle (RVS) changes are characterized using 2nd order polynomials to improve spatial/temporal calibration stability. Relative to the previous R2014 ocean color products, the R2018 calibration removed the suspect late-mission global trends in blue-band water-leaving reflectance, and some anomalously large short-term variability (spikes) in the temporal trend of chlorophyll concentration. This paper will describe the OBPG calibration with a focus on the differences between the MCST and OBPG approaches.

calibration↗

StarHorse results for spectroscopic surveys and Gaia DR3: Chrono-chemical populations in the solar vicinity, the genuine thick disk, and young alpha-rich stars

The Gaia mission has provided an invaluable wealth of astrometric data for more than a billion stars in our Galaxy. The synergy between Gaia astrometry, photometry, and spectroscopic surveys gives us comprehensive information about the Milky Way. Using the Bayesian isochrone-fitting code StarHorse, we derive distances and extinctions for more than 10 million unique stars listed in both Gaia Data Release 3 and public spectroscopic surveys: 557 559 in GALAH+ DR3, 4 531 028 in LAMOST DR7 LRS, 347 535 in LAMOST DR7 MRS, 562 424 in APOGEE DR17, 471 490 in RAVE DR6, 249 991 in SDSS DR12 (optical spectra from BOSS and SEGUE), 67 562 in the Gaia-ESO DR5 survey, and 4 211 087 in the Gaia RVS part of the Gaia DR3 release. StarHorse can increase the precision of distance and extinction measurements where Gaia parallaxes alone would be uncertain. We used StarHorse for the first time to derive stellar ages for main-sequence turnoff and subgiant branch stars, around 2.5 million stars, with age uncertainties typically around 30%; the uncertainties drop to 15% for subgiant-branch-only stars, depending on the resolution of the survey. With the derived ages in hand, we investigated the chemical-age relations. In particular, the α and neutron-capture element ratios versus age in the solar neighbourhood show trends similar to previous works, validating our ages. We used the chemical abundances from local subgiant samples of GALAH DR3, APOGEE DR17, and LAMOST MRS DR7 to map groups with similar chemical compositions and StarHorse ages, using the dimensionality reduction technique t-SNE and the clustering algorithm HDBSCAN. We identify three distinct groups in all three samples, confirmed by their kinematic properties: the genuine chemical thick disk, the thin disk, and a considerable number of young alpha-rich stars (427) that are also a part of the delivered catalogues. We confirm that the genuine thick disk’s kinematics and age properties are radically different from those of the thin disk and compatible with high-redshift (z ≈ 2) star-forming disks with high dispersion velocities. We also find a few extra chemical populations in GALAH DR3 thanks to the availability of neutron-capture element information.

79 ASTRONOMY AND ASTROPHYSICS↗

LAMOST Time-Domain survey: first results of four K2 plates

From Oct. 2019 to Apr. 2020, LAMOST performed a time-domain (TD) spectroscopic survey of four K2 plates with both low- and medium-resolution observations. The low-resolution spectroscopic survey acquired 282 exposures ( ≈ 46.6 h) over 25 nights, yielding a total of about 767 000 spectra, and the medium-resolution survey took 177 exposures ( ≈ 49.1 h) over 27 nights, collecting about 478 000 spectra. More than 70%/50% of low-resolution/medium-resolution spectra have signal-to-noise ratio higher than 10. We determine stellar parameters (e.g., T eff , log g, [Fe/H]) and radial velocity (RV) with different methods, including LASP, DD-Payne and SLAM. In general, these parameter estimations from different methods show good agreement, and the stellar parameter values are consistent with those of APOGEE. We use the Gaia DR2 RV values to calculate a median RV zero point (RVZP) for each spectrograph exposure by exposure, and the RVZP-corrected RVs agree well with the APOGEE data. The stellar evolutionary and spectroscopic masses are estimated based on the stellar parameters, multi-band magnitudes, distances and extinction values. Finally, we construct a binary catalog including about 2700 candidates by analyzing their light curves, fitting the RV data, calculating the binarity parameters from medium-resolution spectra and cross-matching the spatially resolved binary catalog from Gaia EDR3. In conclusion, the LAMOST TD survey is expected to represent a breakthrough in various scientific topics, such as binary systems, stellar activity, stellar pulsation, etc.

79 ASTRONOMY AND ASTROPHYSICS↗