Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Damage Calculation Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurement of regional compliance using 4DCT images for assessment of radiation treatment

Purpose: Radiation-induced damage, such as inflammation and fibrosis, can compromise ventilation capability of local functional units (alveoli) of the lung. Ventilation function as measured with ventilation images, however, is often complicated by the underlying mechanical variations. The purpose of this study is to present a 4DCT-based method to measure the regional ventilation capability, namely, regional compliance, for the evaluation of radiation-induced lung damage. Methods: Six 4DCT images were investigated in this study: One previously used in the generation of a POPI model and the other five acquired at Henry Ford Health System. A tetrahedral geometrical model was created and scaled to encompass each of the 4DCT image domains. Image registrations were performed on each of the 4DCT images using a multiresolution Demons algorithm. The images at the end of exhalation were selected as a reference. Images at other exhalation phases were registered to the reference phase. For the POPI-modeled patient, each of these registration instances was validated using 40 landmarks. The displacement vector fields (DVFs) were used first to calculate the volumetric variation of each tetrahedron, which represents the change in the air volume. The calculated results were interpolated to generate 3D ventilation images. With the computed DVF, a finite element method (FEM) framework was developed to compute the stress images of the lung tissue. The regional compliance was then defined as the ratio of the ventilation and stress values and was calculated for each phase. Based on iterative FEM simulations, the potential range of the mechanical parameters for the lung was determined by comparing the model-computed average stress to the clinical reference value of airway pressure. The effect of the parameter variations on the computed stress distributions was estimated using Pearson correlation coefficients. Results: For the POPI-modeled patient, five exhalation phases from the start to the end of exhalation were denoted by P{sub i}, i=1,...,5, respectively. The average lung volume variation relative to the reference phase (P{sub 5}) was reduced from 18% at P{sub 1} to 4.8% at P{sub 4}. The average stress at phase P{sub i} was 1.42, 1.34, 0.74, and 0.28 kPa, and the average regional compliance was 0.19, 0.20, 0.20, and 0.24 for i=1,...,4, respectively. For the other five patients, their average R{sub v} value at the end-inhalation phase was 21.1%, 19.6%, 22.4%, 22.5%, and 18.8%, respectively, and the regional compliance averaged over all six patients is 0.2. For elasticity parameters chosen from the potential parameter range, the resultant stress distributions were found to be similar to each other with Pearson correlation coefficients greater than 0.81. Conclusions: A 4DCT-based mechanical model has been developed to calculate the ventilation and stress images of the lung. The resultant regional compliance represents the lung's elasticity property and is potentially useful in correlating regions of lung damage with radiation dose following a course of radiation therapy.

60 APPLIED LIFE SCIENCES↗

A Radiation Chemistry Code Based on the Green's Function of the Diffusion Equation

Stochastic radiation track structure codes are of great interest for space radiation studies and hadron therapy in medicine. These codes are used for a many purposes, notably for microdosimetry and DNA damage studies. In the last two decades, they were also used with the Independent Reaction Times (IRT) method in the simulation of chemical reactions, to calculate the yield of various radiolytic species produced during the radiolysis of water and in chemical dosimeters. Recently, we have developed a Green's function based code to simulate reversible chemical reactions with an intermediate state, which yielded results in excellent agreement with those obtained by using the IRT method. This code was also used to simulate and the interaction of particles with membrane receptors. We are in the process of including this program for use with the Monte‐Carlo track structure code Relativistic Ion Tracks (RITRACKS). This recent addition should greatly expand the capabilities of RITRACKS, notably to simulate DNA damage by both the direct and indirect effect.

Plante, Ianik↗

Thermo-mechanical simulations of CO{sub 2} laser–fused silica interactions

CO{sub 2} laser heating of silica glass is used in many scientific and industrial applications. Particularly, localized CO{sub 2} laser heating of silica glass has demonstrated its ability to mitigate surface damage on optics used for high power laser applications. To develop such applications, the control of temperature, heat affected area, and resulting mechanical stresses are critical. Therefore, it is necessary to understand the silica transformation, the material ejection, and the thermo-mechanical stresses induced by the laser heating and subsequent cooling. In this paper, we detail the development of comprehensive thermo-mechanical numerical simulations of these physical processes, based on finite-element method. The approach is developed for 2D or 3D cases to tackle the case of a moving beam at the surface of the sample, and we particularly discuss the choice of the different parameters based on bibliographic inputs. The thermal and mechanical numerical results have been compared to different dedicated experimental studies: infrared thermography measurements at the surface of the irradiated area, optical profilometry measurements of the laser-processed sites, and photo-elastic measurements. Very consistent results are obtained between numerical and experimental results for the description of the temperature gradients, the material ejection, and the residual stresses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of information entropy for convergence assessment of molecular dynamics simulations

The lack of a reliable method to evaluate the convergence of molecular dynamics simulations has contributed to discrepancies in different areas of molecular dynamics. Here, the method of information entropy is introduced to molecular dynamics for stationarity assessment. The Shannon information entropy formalism is used to monitor the convergence of the atom motion to a steady state in a continuous spatial domain and is also used to assess the stationarity of calculated multidimensional fields such as the temperature field in a discrete spatial domain. It is demonstrated in this work that monitoring the information entropy of the atom position matrix provides a clear indicator of reaching steady state in radiation damage simulations, non-equilibrium molecular dynamics thermal conductivity computations, and simulations of Poiseuille and Couette flow in nanochannels. A main advantage of the present technique is that it is non-local and relies on fundamental quantities available in all molecular dynamics simulations. Unlike monitoring average temperature, the technique is applicable to simulations that conserve total energy such as reverse non-equilibrium molecular dynamics thermal conductivity computations and to simulations where energy dissipates through a boundary as in radiation damage simulations. The method is applied to simulations of iron using the Tersoff/ZBL splined potential, silicon using the Stillinger–Weber potential, and to Lennard–Jones fluid. Its applicability to both solids and fluids shows that the technique has potential for generalization to other areas in molecular dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Correlation of electron and proton irradiation-induced damage in InP solar cells

When determining the best solar cell technology for a particular space flight mission, accurate prediction of solar cell performance in a space radiation environment is essential. The current methodology used to make such predictions requires extensive experimental data measured under both electron and proton irradiation. Due to the rising cost of accelerators and irradiation facilities, such extensive data sets are expensive to obtain. Moreover, with the rapid development of novel cell designs, the necessary data are often not available. Therefore, a method for predicting cell degradation based on limited data is needed. Such a method has been developed at the Naval Research Laboratory based on damage correlation using 'displacement damage dose' which is the product of the non-ionizing energy loss (NIEL) and the particle fluence. Displacement damage dose is a direct analog of the ionization dose used to correlate the effects of ionizing radiations. In this method, the performance of a solar cell in a complex radiation environment can be predicted from data on a single proton energy and two electron energies, or one proton energy, one electron energy, and Co(exp 60) gammas. This method has been used to accurately predict the extensive data set measured by Anspaugh on GaAs/Ge solar cells under a wide range of electron and proton energies. In this paper, the method is applied to InP solar cells using data measured under 1 MeV electron and 3 MeV proton irradiations, and the calculations are shown to agree well with the measured data. In addition to providing accurate damage predictions, this method also provides a basis for quantitative comparisons of the performance of different cell technologies. The performance of the present InP cells is compared to that published for GaAs/Ge cells. The results show InP to be inherently more resistant to displacement energy deposition than GaAs/Ge.

Walters, Robert J.↗

TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks

Purpose: Radiotherapy treatment is specified by radiation dose prescriptions, but biological DNA damage actually controls treatment effectiveness. It is impractical to directly measure dose in the clinic, so we measure quantities, such as collected charge, and calculate the relationship to dose. At small fields, such as those in stereotactic radiosurgery (SRS), charged-particle equilibrium (CPE) breaks down and the accuracy of the measurement for delivered dose decreases. By measuring DNA double-strand breaks (DSB) directly, we believe treatment accuracy could improve by providing a more meaningful measurement. Methods: A DNA dosimeter, consisting of magnetic streptavidin beads attached to 4 kilobase pair DNA strands labeled with biotin and fluorescein amidite (FAM) on opposing ends, was suspended in phosphate-buffered saline (PBS). Twenty µL samples were placed in plastic micro-capillary tubes inside a water tank setup and irradiated with 10 cm, 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm radiation field sizes, where the three smallest sizes were cones. After irradiation, the dosimeters were mechanically separated into beads (intact DNA) and supernatant (broken DNA/FAM) using a magnet. The fluorescence was read and the probability of DSB was calculated. This was used to calculate the output factor for an SRS beam and compared to that measured using a diode detector. Results: The output factors relative to a 10 cm field were 0.89±0.07, 0.76±0.08, 0.59±0.04, and 0.78±0.12 for the field sizes of 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm, respectively. Some of the diode measurements do not fall within these uncertainties. Conclusion: This was the first attempt to measure output factors in a water tank with the DNA dosimeter. Although differences compared to the diode were observed, the uncertainty analysis ignored systematic errors. For future work, we will repeat this experiment to quantify and correct systematic errors, such as those caused by positional alignment and sample contamination. This work was funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

Radiation Dose–Dependent Hippocampal Atrophy Detected With Longitudinal Volumetric Magnetic Resonance Imaging

Purpose: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. Methods and Materials: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI before and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. Results: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=−0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean −6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). Conclusions: The hippocampus demonstrates radiation dose–dependent atrophy after treatment for brain tumors. Quantitative MRI is a noninvasive imaging technique capable of measuring radiation effects on intracranial structures. This technique could be investigated as a potential biomarker for development of reliable dose constraints for improved cognitive outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Griffin's Transmutation Solver to Calculate Radiation Damage

Displacement Radiation Damage originates from all nuclides, not just those that are naturally occurring. Currently only damage from naturally-occurring nuclides, or sometimes damage from one transmutation product is considered. It is proposed that the transmutation solvers implemented in many codes be used to calculate this radiation damage. This would explicitly treat damage from all sources without additionally burdening the user. A proof-of-concept implementation was created in Griffin. The implementation showed that only minor code modifications are necessary to add this feature. When compared against an analytical benchmark the results Griffin could calculate were very accurate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron knock-on damage in hexagonal boron nitride monolayers

We combine first-principles molecular-dynamics simulations with high-resolution transmission electron microscopy experiments to draw a detailed microscopic picture of irradiation effects in hexagonal boron nitride (h-BN) monolayers. We determine the displacement threshold energies for boron and nitrogen atoms in h-BN, which differ significantly from the tight-binding estimates found in the literature and remove ambiguity from the interpretation of the experimental results. We further develop a kinetic Monte Carlo model which allows to extend the simulations to macroscopic time scales and make a direct comparison between theory and experiments. Our results provide a comprehensive picture of the response of h-BN nanostructures to electron irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydroxyl radical yields in the heavy ion radiolysis of water

Scavenging experiments coupled with Monte Carlo track structure and kinetics simulations have been used to determining and understand the yields of hydroxyl radicals in the radiolysis of water with protons and carbon ions. Carbon dioxide production from aerated formic acid solutions with concentrations ranging from 10-3 to 1 mol./dm3 was used as a probe of the time dependence of the hydroxyl radical yield from about 5 ns to 1 ?s. Numerical extrapolation of the results at slightly different ion energies in combination with data from gamma radiolysis experiments allows a systematic analysis of both track average and track segment yields, with considerable track chemistry found to occur on the nanosecond to microsecond time scale. Track chemistry calculations utilizing Monte Carlo track structure simulations and nonhomogeneous independent reaction times diffusion-reaction modeling of product yields reproduce experimental observations. Subsequently, the track simulation methods were used to predict hydroxyl radical kinetics in deaerated and aerated water at neutral pH. Taken with literature data for helium ion beam studies, the results offer insight into the potential for indirect radiation induced damage to biological systems for light ions with very different track structures.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Statistical Study of Primary Knock-on Atoms under Neutron Irradiation in RMC Code

Materials in high flux neutron condition will suffer from an evolution of damage which ultimately restricts the lifetime of the fuel clad and reactor pressure vessel. Atoms in irradiated material transform to primary knock-on atoms (PKAs) by absorbing the kinetic energy transferred from neutrons, and the energy released from nuclear reactions. The secondary collision cascades which are induced by PKAs create point defects within the material, with residual vacancies and interstitials eventually causing swelling and embrittlement that degrades mechanical behavior. For a long time, Displacements per Atom (DPA) index has been identified as a measure of radiation damage in material. Nowadays, several advanced methods, such as Molecular Dynamics (MD) and Kinetic Monte Carlo (KMC) simulations, have been developed for more accurately simulating the evolution of the damage. However, all of these techniques need more comprehensive information of PKA, such as the type, energy, direction and spatial distribution. The limitations of DPA emerge and a method should be provided to simulate the generative process of PKAs. Recently, a deterministic analysis code SPECTRA-PKA has been developed by Gilbert to calculate the energy spectra of almost all types PKAs by solving the group-to-group cross-section matrices equation which includes neutron scattering, light charged particles, and recoils of the residual nuclei. But this deterministic analysis code could not give the direction, spatial and time distribution of PKAs. Based on the Geant4 program, Cui Zhenguo has simulated the irradiation by neutrons with 1 MeV energy in zirconium, while only the two adjacent elastic collisions between injected neutron and target atoms are taken into consideration. In this paper, Monte Carlo method to calculate PKAs information during neutron transport in RMC code is introduced. RMC is a continuous-energy Reactor Monte Carlo neutron and photon transport code being developed by Department of Engineering Physics at Tsinghua University, Beijing. PKAs in zirconium are calculated in fixed neutron source mode. Statistical information of PKAs in PWR fuel cell and SFR fuel cell is shown and compared. The results show that Monte Carlo method can provide more comprehensive information of PKAs. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-272: Radiation Damage Comparison Between Intensity Modulated Radiotherapy and Field-In-Field Technique in Breast Cancer Treatments

Purpose: To compare normal tissue complications between IMRT and FIF treatment in breast cancer. Methods: 16 patients treated with IMRT plan and 20 patients treated with FIF plan were evaluated in this study. Both kinds of plans were generated using Eclipse treatment planning system by dosimetrist following clinical radiotherapy treatment guidelines. The plans were reviewed and approved by radiation oncologist. The average survival fraction (SF) for three different normal tissue cells of each concerned structure can be calculated from differential dose volume histogram (DVH) using linear quadratic model. The three types of normal tissues include radiosensitive, moderately radiosensitive and radio-resistant that represents 70%, 50% and 30% survival fractions, respectively, for a 2-Gy open field. Equivalent uniform doses (EUD) for corresponding normal tissues of each structure were calculated. Results: The EUDs of the lungs, heart, healthy breast and spinal cord with both IMRT and FIF treatments were calculated. Considering the average value of all IMRT plans, the lung of treated side absorbed 16.0% of dosage prescribed to the tumor if the radiosensitivity of the lung is similar to the radiosensitive cell line. For moderately radiosensitive and radio-resistant lung tissue, the average EUDs can be 18.9% and 22.4% of prescription. In contrast, patients treated with FIF plans were delivered 6.0%, 7.5% and 10.3% of prescribed dose for radiosensitive, moderately radiosensitive and radio-resistant lung tissue, respectively. Comparing heart EUDs between IMRT and FIF plans, average absorbed doses in IMRT treatment were 7.7%, 8.7% and 9.7% of prescription for three types of heart normal tissue cell lines while FIF treatments delivered only 1.3%, 1.5% and 1.6% of prescription dose. For the other organs, the results were similar. Conclusion: The results indicated that breast cancer treatment using IMRT technique had more normal tissue damage than FIF treatment. FIF demonstrated more effective normal tissue dose reduction in breast cancer treatment.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-06: Nanoparticle-Aided External Beam Radiotherapy Leveraging the Cerenkov Effect

Purpose: This study investigates the feasibility of exploiting the Cerenkov radiation (CR) present during external beam radiotherapy (EBRT) for significant therapeutic gain, using titanium dioxide nanoparticles (titania) delivered via a new design of radiotherapy biomaterials. Methods: Recently published work has shown that CR generated by radionuclides during PET imaging could substantially enhance damage to cancer cells in the presence of 0.625 µg/g titania. We hypothesize that equal or greater damage can be achieved during EBRT. To test this hypothesis, Monte Carlo simulation was done using GEANT4 in order to get the total CR yield inside a tumor volume during EBRT compared to that of the radionuclides. We considered a novel approach where a sufficiently potent concentration of the titania was delivered directly into the tumor using radiotherapy biomaterials (e.g. fiducials) loaded with the titania. The intra-tumor distribution/diffusion of titania released from the fiducials was calculated. An in-vitro MTS assay experiment was also carried out to establish the relative non-toxicity of titania for concentrations of up to 1 µg/g. Results: For a radiotherapy biomaterial loaded with 15 µg/g of 2-nm titania, at least 0.625 µg/g could be delivered through out a tumor sub-volume of 2-cm diameter after 14 days. This concentration level could inflict substantial damage to tumor cells during EBRT. The Monte Carlo results showed the CR yield in tumor by 6 MV radiation was higher than the radionuclides and hence potentially greater damage may be obtained during EBRT. No significant cell viability change was observed for 1 µg/g titania. Conclusion: Altogether, these preliminary findings demonstrate a potential new approach that can be used to take advantage of the CR present during megavoltage EBRT to boost damage to tumor cells. The results provide significant impetus for further experimental studies towards development of nanoparticle-aided EBRT powered by the Cerenkov effect.

60 APPLIED LIFE SCIENCES↗

Effect of Prolonged Ultraviolet Radiation Exposure on the Blast Response of Fiber Reinforced Composite Plates

An experimental study with corresponding numerical simulations was conducted to evaluate the blast response of composite plates after prolonged exposure to ultraviolet radiation. Two composite materials were used in this study, namely carbon fiber/epoxy and glass fiber/vinyl ester. The composite materials consisted of four unidirectional fiber plies oriented in a [± 45°]s layup. The plates were placed in a QUV Accelerated Weathering Tester for 500 h of exposure on each face, totaling 1000 h of ultraviolet radiation exposure, equivalent to 2.5 MJ/m{sup 2} of energy. The QUV Accelerated Weathering Tester was equipped with eight UVA-340 lamps to provide real service life exposure conditions. Material characterization experiments were performed on virgin specimens, as well as specimens exposed to ultraviolet radiation for 1000 h to determine its effect on the mechanical properties of the composites. Blast experiments were conducted on the composite plates to investigate the dynamic response before and after exposure to ultraviolet radiation. The plates were clamped on all edges and subjected to an air blast using a shock tube apparatus. Three-dimensional digital image correlation was coupled with high-speed photography to obtain full-field displacements of the specimens during blast loading. Furthermore, three piezoelectric pressure transducers were mounted on the shock tube apparatus and utilized to measure the pressure history of the shock wave loading. The quasi-static material characterization showed that the tensile modulus E{sub 1} had minimal change after exposure to ultraviolet radiation for 1000 h. However, matrix-dominated properties such as the in-plane shear modulus G{sub 12} increased after exposure to ultraviolet light for both the carbon and glass fiber composites, which resulted in lower out-of-plane displacements during blast loading. For the carbon fiber plates, the forced vibration frequency induced by the transverse blast load was higher in plates exposed to ultraviolet radiation when compared to virgin specimens. However, for the glass fiber plates exposed to ultraviolet radiation, the forced vibration frequency decreased when compared to virgin specimens. Finally, the finite element simulations were in good agreement with the experimental results. The simulations revealed that the glass fiber plates exposed to ultraviolet radiation had higher failure strains at the boundary than virgin specimens, despite having higher stiffness. A parametric study in which higher loading was simulated also showed that the glass fiber plates experienced more damage after 1000 h of ultraviolet radiation exposure.

36 MATERIALS SCIENCE↗

Reproducible radiation-damage processes in proteins irradiated by intense x-ray pulses

X-ray free-electron lasers have enabled femtosecond protein nanocrystallography, a novel method to determine the structure of proteins. It allows time-resolved imaging of nanocrystals that are too small for conventional crystallography. The short pulse duration helps in overcoming the detrimental effects of radiation damage because x rays are scattered before the sample has been significantly altered. It has been suggested that, fortuitously, the diffraction process self-terminates abruptly once radiation damage destroys the crystalline order. Our calculations show that high-intensity x-ray pulses indeed trigger a cascade of damage processes in ferredoxin crystals, a particular metalloprotein of interest. However, we found that the damage process is initially not completely random. Correlations exist among the protein monomers, so that Bragg diffraction still occurs in the damaged crystals, despite significant atomic displacements. Our results show that the damage process is reproducible to a certain degree, which is potentially beneficial for the orientation step in single-molecule imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-127: Charged Particle Transport in Condensed Media

Purpose: Provide quality interaction cross sections for charged particle Monte Carlo (MC) track structure codes and evaluate low energy electron transport in condensed media. Methods: MC methods and codes are often used to model or simulate charged particle radiation transport in matter. Detailed (or event-by-event) track structure simulations are of special interest for the modeling of the physical and chemical stages of radiation action with matter and the initial radiation damage to biological systems. They require reliable interaction cross sections of all radiation qualities considered (e.g., electrons, protons, alpha particles, light and heavy ions) with the target material under consideration, mainly in the condensed phase, including liquids and solids. Interaction cross sections are calculated using the dielectric formalism, a mixture of first principles, theoretical modeling and experimental information for bulk and surface transport and implemented into MC track structure codes. Secondary electron emission yields from amorphous solid water (ASW) and thin metal foils (copper and gold) after fast proton impact are simulated and measured experimentally. Results: After considering different transport models for bulk and surface transport and a careful modeling of the experimental geometry, simulated secondary electron emission yields follow the trends of experimental data well. Furthermore, yields for electron emissions below 50 eV are sensitive to differential elastic scattering cross sections. Conclusion: Low-energy electron transport in condensed media is still a challenge for detailed track structure simulation codes. Interaction cross-sections, transport models, and target geometry need to be considered adequately. The research was funded in part by NSF Major Research Instrumentation Program 2009, Award Number: 0923270 and by NIH/NCI R01 CA93351.

60 APPLIED LIFE SCIENCES↗

Fundamental Science-Based Simulation of Nuclear Waste Forms

This report presents a hierarchical multiscale modeling scheme based on two-way information exchange. To account for all essential phenomena in waste forms over geological time scales, the models have to span length scales from nanometer to kilometer and time scales from picoseconds to millenia. A single model cannot cover this wide range and a multi-scale approach that integrates a number of different at-scale models is called for. The approach outlined here involves integration of quantum mechanical calculations, classical molecular dynamics simulations, kinetic Monte Carlo and phase field methods at the mesoscale, and continuum models. The ultimate aim is to provide science-based input in the form of constitutive equations to integrated codes. The atomistic component of this scheme is demonstrated in the promising waste form xenotime. Density functional theory calculations have yielded valuable information about defect formation energies. This data can be used to develop interatomic potentials for molecular dynamics simulations of radiation damage. Potentials developed in the present work show a good match for the equilibrium lattice constants, elastic constants and thermal expansion of xenotime. In novel waste forms, such as xenotime, a considerable amount of data needed to validate the models is not available. Integration of multiscale modeling with experimental work is essential to generate missing data needed to validate the modeling scheme and the individual models. Density functional theory can also be used to fill knowledge gaps. Key challenges lie in the areas of uncertainty quantification, verification and validation, which must be performed at each level of the multiscale model and across scales. The approach used to exchange information between different levels must also be rigorously validated. The outlook for multiscale modeling of wasteforms is quite promising.

Continuum Model↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗