Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Review of Hybrid (Deterministic/Monte Carlo) Radiation Transport Methods, Codes, and Applications at Oak Ridge National Laboratory

This paper provides a review of the hybrid (Monte Carlo/deterministic) radiation transport methods and codes used at the Oak Ridge National Laboratory and examples of their application for increasing the efficiency of real-world, fixed-source Monte Carlo analyses. The two principal hybrid methods are (1) Consistent Adjoint Driven Importance Sampling (CADIS) for optimization of a localized detector (tally) region (e.g., flux, dose, or reaction rate at a particular location) and (2) Forward Weighted CADIS (FW-CADIS) for optimizing distributions (e.g., mesh tallies over all or part of the problem space) or multiple localized detector regions (e.g., simultaneous optimization of two or more localized tally regions). The two methods have been implemented and automated in both the MAVRIC sequence of SCALE 6 and ADVANTG, a code that works with the MCNP code. As implemented, the methods utilize the results of approximate, fast-running 3-D discrete ordinates transport calculations (with the Denovo code) to generate consistent space- and energy-dependent source and transport (weight windows) biasing parameters. These methods and codes have been applied to many relevant and challenging problems, including calculations of PWR ex-core thermal detector response, dose rates throughout an entire PWR facility, site boundary dose from arrays of commercial spent fuel storage casks, radiation fields for criticality accident alarm system placement, and detector response for special nuclear material detection scenarios and nuclear well-logging tools. Substantial computational speed-ups, generally O(102-4), have been realized for all applications to date. This paper provides a brief review of the methods, their implementation, results of their application, and current development activities, as well as a considerable list of references for readers seeking more information about the methods and/or their applications.

97 MATHEMATICS AND COMPUTING↗

Analysis of Radiation Transport Due to Activated Coolant in the ITER Neutral Beam Injection Cell

Detailed spatial distributions of the biological dose rate due to a variety of sources are required for the design of the ITER tokamak facility to ensure that all radiological zoning limits are met. During operation, water in the Integrated loop of Blanket, Edge-localized mode and vertical stabilization coils, and Divertor (IBED) cooling system will be activated by plasma neutrons and will flow out of the bioshield through a complex system of pipes and heat exchangers. This paper discusses the methods used to characterize the biological dose rate outside the tokamak complex due to 16 N gamma radiation emitted by the activated coolant in the Neutral Beam Injection (NBI) cell of the tokamak building. Activated coolant will enter the NBI cell through the IBED Primary Heat Transfer System (PHTS), and the NBI PHTS will also become activated due to radiation streaming through the NBI system. To properly characterize these gamma sources, the production of 16 N, the decay of 16 N, and the flow of activated water through the coolant loops were modeled. The impact of conservative approximations on the solution was also examined. Once the source due to activated coolant was calculated, the resulting biological dose rate outside the north wall of the NBI cell was determined through the use of sophisticated variance reduction techniques. The AutomateD VAriaNce reducTion Generator (ADVANTG) software implements methods developed specifically to provide highly effective variance reduction for complex radiation transport simulations such as those encountered with ITER. Using ADVANTG with the Monte Carlo N-particle (MCNP) radiation transport code, radiation responses were calculated on a fine spatial mesh with a high degree of statistical accuracy. In conclusion, advanced visualization tools were also developed and used to determine pipe cell connectivity, to facilitate model checking, and to post-process the transport simulation results.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of the Performance of Various Correlated Fission Multiplicity Monte Carlo Codes

When measuring special nuclear material for a large array of national security needs, it is often important to accurately predict outcomes of the physical experiment using Monte Carlo radiation transport codes. Historically, radiation transport codes have uncorrelated fission emissions. In reality, both spontaneous and induced fissions release particles that are correlated in time, energy, and multiplicity. This work investigates the performance of various current Monte Carlo codes that take into account the correlated physics of fission neutrons. Only fission neutrons are of interest and the physics of gamma production in fission is ignored. Because of their large impact on correlated neutron results, underlying fission neutron multiplicity distributions utilized by the different codes are also compared. The codes currently being compared include MCNP{sup R}6, MCNP{sup R}6/FREYA, and MCNPX-PoliMi. By default, MCNP{sup R}6 uses a bounded integer treatment to sample the number of neutrons emitted from each fission event. The FMULT card, an optional input in MCNP that allows for user definition of spontaneous and induced fission parameters, can be utilized to call either built-in or user-specified multiplicities to replace the bounded integer treatment. Similarly, MCNPX-PoliMi utilizes one of a few different built-in multiplicity sets. MCNPX-PoliMi also models the multiplicity dependence of emitted neutron energy in spontaneous fission. It is possible to use an anisotropic model for emitted fission neutrons in MCNPXPoliMi, but this option was not used. For MCNP{sup R}6/FREYA, the FREYA fission event generator determines the number of particles emitted for each fission event and gives the results to MCNP{sup R}6 for transport. The fission event generator uses fission fragment mass and kinetic energy distributions, unbounded statistical evaporation models, and conservation of energy and momentum to generate the number, energy, and direction of neutrons released by each fission event. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

grmonty: A MONTE CARLO CODE FOR RELATIVISTIC RADIATIVE TRANSPORT

We describe a Monte Carlo radiative transport code intended for calculating spectra of hot, optically thin plasmas in full general relativity. The version we describe here is designed to model hot accretion flows in the Kerr metric and therefore incorporates synchrotron emission and absorption, and Compton scattering. The code can be readily generalized, however, to account for other radiative processes and an arbitrary spacetime. We describe a suite of test problems, and demonstrate the expected N {sup -1/2} convergence rate, where N is the number of Monte Carlo samples. Finally, we illustrate the capabilities of the code with a model calculation, a spectrum of the slowly accreting black hole Sgr A* based on data provided by a numerical general relativistic MHD model of the accreting plasma.

79 ASTRONOMY AND ASTROPHYSICS↗

In Situ Visualization of Radiation Transport Geometry

The ultimate goal for radiation transport is to perform full-core reactor modelling and simulation. Advances in computational simulation bring this goal close to reality and the newest Monte Carlo transport codes have begun to shift to using accelerators that have become a stalwart in the supercomputing and HPC space. Within the reactor modelling and simulation community, Monte Carlo transport simulations are considered the gold standard for simulation. Through the use of "combinatorial geometry" (constructive solid geomtry), complex models can be used with fewer approximation compromises while at the same time scale to run on some of the largest supercomputers in the world.Unfortunately, the state-of-the-art for "combinatorial geometry" visualization is to decompose the geometry into a mesh. This approach could require a significant amount of memory which is antithetical to in situ visualization. To address this issue, we introduce a ray caster for visualizing combinatorial geometry in radiation transport code. By only using the accelerators for the radiation transport code and leaving the CPU cores idle, there is an opportunity to conduct on node in situ visualization with the idle CPU cores, something domain experts have up to this point been unable to do. By utilizing VTK-m, the visualization can be run on the CPU as this particular application demands, but also run on any architecture that is supported by VTK-m, enabling future re-use across different platforms.

Kim, Mark B.↗

l3d2vtk: An MCNPTools Utility to Enable LNK3DNT File Visualization & Post-Processing

This paper describes recent work to develop and incorporate a utility program into the MCNPTools package that enables LNK3DNT file visualization & post-processing. A LNK3DNT file is a binary Cartesian, cylindrical, or spherical structured mesh file that describes material and material relative density distributions by mesh voxel. This mesh file format is principally used by the PARTISN discrete-ordinates radiation-transport code. However, the MCNP ® Monte Carlo radiation-transport code can use LNK3DNT files to specify geometry, and the MCNP code can produce LNK3DNT files representing a user-defined region of the MCNP constructive solid geometry (CSG). Because of the use of LNK3DNT files as MCNP input and output and with other computer codes, improving the ability to visualize and/or quantitatively post-process LNK3DNT files benefits end users. In particular, it is helpful to visually verify that the material and density distributions are as expected. Also, an analyst can orient viewers with respect to other in formation, e.g., by co-plotting a voxelized representation of MCNP CSG with mesh tally and/or particle track results. However, until now, the only capability to interactively interrogate LNK3DNT files is through a 2-D slice plotter provided by the Monte Carlo Application ToolKit (MCATK), which is not currently distributed outside of Los Alamos National Laboratory. The utility created as part of this work converts LNK3DNT binary files to an ASCII XML-based StructuredMesh VTK (.vts) file. The geometries supported are 1-D spherical and cylindrical ( r ), 1-D Cartesian ( x ), 2-D cylindrical ( r-z and r-θ ) and Cartesian ( x-y ), and 3-D cylindrical ( r-z-θ ) and Cartesian ( x-y-z ). This file format is chosen to minimize external dependencies (e.g., on an HDF5 library) and to provide a file that can be interrogated by the user in a text editor or standard visualization applications (e.g., ParaView or VisIt). However, other file formats may provide more utility such as XDMF, which can use HDF5 and is discussed further as something to explore as future work. This paper is organized as follows: a brief introduc tion to the MCNPTools library and utility programs is given, the LNK3DNT-to-VTK (l3d2vtk) utility functionality is de scribed, and then an example post-processing workflow using the ParaView application is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PIMAL: Phantom wIth Moving Arms and Legs Version 4.1.0

Computational phantoms with articulated arms and legs have been developed to enable radiation dose estimation for male and female receptors in different postures. Using a user-friendly graphical user interface (GUI), the PIMAL (Phantom wIth Moving Arms and Legs) software can be employed to adjust the posture of a phantom, generate a corresponding input file for the Monte Carlo N-Particle (MCNP®) radiation transport code, and perform the radiation transport simulations for the dose calculations in MCNP®. The MCNP® code can be run natively from the PIMAL interface or externally in the MCNP® command prompt via the generated MCNP® PIMAL input file.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Validation of the Shift Monte Carlo Code for Fixed-Source Radiation Transport Problems

Simulations of neutron and photon transport using the Shift Monte Carlo radiation transport code are compared with experimental measurements and their corresponding benchmark simulations from several sets of experiments. Overall, Shift results match the calculations made by the benchmark teams quite well and match the measured values, which typically have large uncertainties, fairly well. A variety of attenuation/scattering problems are examined, as well as a streaming problem and a skyshine problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Introduction to an MCGIDI Mini-App and Performance Comparisons with XSBench

In high-performance Monte Carlo (MC) radiation transport codes, cross section lookups often account for the majority of computational expens. In response to this observation, a number of nuclear data mini-apps have been developed to profile and optimize the lookup process. A review of these mini-apps can be found in Ref. In contrast to a fully fledged MC code, nuclear data mini-apps do not feature particle tracking; instead, the cross section lookup process is considered in isolation, a simplification that allows for easier implementation and evaluation of various lookup schemes and techniques. GIDI+, as described on its public repository1, is ...a collection of C++ libraries for accessing evaluated and processed nuclear data stored in the Generalized Nuclear Database Structure (GNDS). In addition to reading GNDS files, GIDI+ has functions to sum and collapse multi-group data as needed by deterministic transport codes, and to sample GNDS data as needed by Monte Carlo transport codes. Certain modes of Mercury, a LLNL-developed MC radiation transport code, utilize GIDI+ for cross section lookups. Specifically, Mercury uses the MCGIDI library contained within GIDI+ to perform lookups on GPUs. A mini-app exercising MCGIDI’s cross section lookup capabilities would prove useful for optimization, which in turn could improve the performance of client codes such as Mercury. Such a mini-app could also be used to assess the performance of MCGIDI compared to other nuclear data mini-apps. In this document, we introduce a nuclear data mini-app built with the MCGIDI library. The MCGIDI mini-app (MCGIDI-MA) was developed to closely resemble the methodology present in XSBench, a nuclear data mini-app developed at Argonne National Laboratory. The remainder of this section provides an overview on XSBench. Section 2 describes MCGIDI-MA and its usage. Section 3 contains performance results of MCGIDI-MA on LLNL’s Lassen and Quartz compute platforms, as well as comparisons to XSBench performance where appropriate. In Section 4, we present a summary of our findings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Full 3D visualization tool-kit for Monte Carlo and deterministic transport codes

We propose a package of tools capable of translating the geometric inputs and outputs of many Monte Carlo and deterministic radiation transport codes into open source file formats. These tools are aimed at bridging the gap between trusted, widely-used radiation analysis codes and very powerful, more recent and commonly used visualization software, thus supporting the design process and helping with shielding optimization. Three main lines of development were followed: mesh-based analysis of Monte Carlo codes, mesh-based analysis of deterministic codes and Monte Carlo surface meshing. The developed kit is considered a powerful and cost-effective tool in the computer-aided design for radiation transport code users of the nuclear world, and in particular in the fields of core design and radiation analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multigroup Neutron Cross Section Generation for the SCEPTRE Code

Multigroup neutron cross sections were generated for the deterministic radiation transport code SCEPTRE. ENDF/B-VII.1 nuclear data files were downloaded from Los Alamos National Laboratory (LANL), processed with the LANL cross-section preparation code NJOY-2012, and post-processed to produce a SCEPTRE-formatted cross section file. A simple radiation transport problem was used to compare results calculated with MCNP, a continuous-energy radiation transport code from LANL, to results calculated with SCEPTRE using the NJOY-2012-produced multigroup cross sections. This problem was used to debug the python scripts used to post-process the NJOY-2012 output and to assess the accuracy of the multigroup cross sections. These comparisons demonstrate that the multigroup cross sections generated in this work are accurate for most elements but yielded inaccurate results for several common transition metals. This discrepancy appears to result from poor treatment of the resolved resonance region of the continuous-energy cross sections. Further work is recommended to investigate alternative methods to treat these resonances with NJOY-2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP6 Gets Correlated with CGM 3.4 - Paper 41

Version 3.4 of the Cascading Gamma-ray Multiplicity (CGM) code has been integrated into version 6 of the Monte Carlo radiation transport code MCNP. The current release is MCNP6 which is the merger of MCNPX 2.7.0 and MCNP5. MCNP6 is a general purpose Monte Carlo radiation transport code that can transport 34 different particles and heavy ions. CGM was originally integrated into MCNPX 2.7.0 as an undocumented feature, but was never released to the public. With the integration of CGM into MCNP6 the code now has the capability of producing correlated secondary particle/gamma emissions and should be available in future release of MCNP. Before the integration of CGM, MCNP only used libraries that contain the total multiplicity but not the multiplicity distribution or the correlations. Lacking this information requires the code to use integer sampling to determine the multiplicity. In the example of thermal neutron capture on Cl-35, presented in the results section, MCNP does integer sampling. This means MCNP would produce one gamma 17% of the time and two gammas 82% giving a mean multiplicity of 1.83. Using CGM, MCNP can now produce a spectrum of multiplicities. The use of CGM has several advantages over the use of ACE data libraries in MCNP6: 1) it has correlated gamma production, 2) it produces a distribution of gamma multiplicities per interaction, whereas ACE produces an average between two integer multiplicities, 3) it is a theoretical model that may predict experimentally unmeasured physical quantities that may not be in experimental based data libraries. CGM conserves energy and angular momentum internally to CGM; however, angular emission information is not currently sent back to MCNP6. Future work will include the integration of correlated neutrons from CGM. Also, the reaction type will be passed to CGM to set the spin and parity for a particular reaction when possible. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Mapping at JET and ITER using advanced computational acceleration techniques and tools - Paper 63

The Applied Radiation Physics group at the Culham Centre for Fusion Energy (CCFE) have developed and applied state-of-the-art radiation mapping methods and tools to enable complex shielding calculations in fusion devices during plasma operations, and associated maintenance in the device and surrounding areas. Here, we present the description and application of those tools to produce radiation maps both to support the JET safety case (the EU experimental tokamak device based at Culham) and the planned DT campaign in the next few years; and the ITER device. Radiation mapping of fusion facilities are essential for assessing radiation hardness of electronics during operations, and to define safe working dose limits to staff during routine maintenance. At CCFE the Monte Carlo radiation transport code MCNP6 is one of the codes used to perform radiation transport calculations. Due to the size and complexity of the JET and ITER devices, and their surrounding buildings, a suite of tools have been created at CCFE to reduce the computational requirements of the calculations. This paper describes three of these tools, which have been developed and applied to nuclear and radiological field mapping in fusion devices. The results presented in this paper highlight the application of three methods that have been used to improve the computational efficiency and capabilities for radiation mapping in fusion devices such as JET and ITER. These methods are Global Variance Reduction, the Surface Source Mesh routine and the Smeared Source routine. This paper demonstrates the three techniques used in combination, enabling a very computationally challenging fusion problem to become tractable (with acceptable computing effort), also enabling improved capability to allow the mapping of radiations fields during transport operations for activated materials. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

(U) Radiation Hydrodynamics in the Ristra Project’s Symphony code: Initial release

One of the recent focuses in the next-generation code (NGC/Ristra)project at LANL is to develop a cell-centered Lagrangian radiation-hydrodynamics code under FleCSI framework. The FleCSI frame-work provides a unified data and execution model in order to insulate production code development from the uncertainty of evolving runtimeand architectures. We have developed the code, Symphony, which in-corporates the hydrodynamics code, FleCSALE, and the radiation transport code, Puno.This memo is intended to describe the coupling of radiation and hydrodynamics within the Ristra Project’s code Symphony.

97 MATHEMATICS AND COMPUTING↗

Synthetic Spectra of Pair-instability Supernovae in 3D

Pair-instability supernovae (PISNe) may signal the deaths of extremely massive stars in the local Universe or massive primordial stars after the end of the Cosmic Dark Ages. Hydrodynamic simulations of these explosions, performed in 1D, 2D, and 3D geometry, have revealed the strong dependence of mixing in the PISN ejecta on dimensionality. This chemical rearrangement is mainly driven by Rayleigh–Taylor instabilities that start to grow shortly after the collapse of the carbon–oxygen core. We report on the effects of such mixing on the spectroscopic evolution of PISNe by post-processing explosion profiles with the radiation diffusion-equilibrium code SNEC and the implicit Monte Carlo–discrete diffusion Monte Carlo radiation transport code SuperNu . The first 3D radiation transport calculation of a PISN explosion is presented, yielding viewing-angle-dependent synthetic spectra and light curves. Our findings show that while 2D and 3D mixing does not significantly affect the light curves of PISNe, their spectroscopic and color evolution are impacted. Strong features of intermediate-mass elements dominated by silicon, magnesium, and oxygen appear at different phases and reach different intensities depending on the extent of mixing in the silicon/oxygen interface of the PISN ejecta. In contrast, we do not find a significant dependence of PISN light curves and spectra on viewing angle. These results showcase the capabilities of SuperNu to handle 3D radiation transport and highlight the importance of modeling time series of spectra in identifying PISNe with future missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Criticality and Radiation Shielding Analysis for the Storage and Transfer of MARVEL Reactor Spent Nuclear Fuel

This report documents the results of preliminary nuclear criticality and radiation shielding assessments during transfer and dry storage of irradiated Microreactor Applications Research Validation and Evaluation (MARVEL) reactor fuel at Idaho National Laboratory (INL). The assessments focus on transfer casks and storage canisters that are currently in use at INL, which may be compatible with the irradiated MARVEL reactor fuel. The criticality assessments were performed using the radiation transport code MCNP6 with 37 MARVEL reactor fuel elements in various configurations and scenarios. All transfer and storage configurations under dry conditions were below the assumed criticality safety limit of 0.93. Some storage and transfer configurations under wet conditions exceeded the criticality safety limit. This suggests that the appropriate administrative and engineering controls, in addition to reducing the number of MARVEL reactor fuel elements per transfer cask or storage canister, can be expected to ensure criticality safety under all scenarios. The radiation shielding assessments were performed by generating conservative neutron and photon source terms using the ORIGEN module in the SCALE suite of codes. These source spectra were used to estimate the dose equivalent rates using the radiation transport code MCNP6, both on contact and 1 m away from the fuel and transfer casks. The maximum estimated dose equivalent rate of 37 unshielded MARVEL reactor fuel elements on contact is approximately 42000 R/hr. The maximum estimated dose equivalent rates on contact to the ATR transfer cask, HFEF-5 transfer cask, and high load charger were approximately 233 mR/hr, 171 mR/hr, and 201 mR/hr, respectively. This suggests that with the appropriate administrative and engineering controls, all three transfer casks analyzed can be expected to provide sufficient radiation shielding to workers during transfer of irradiated MARVEL reactor fuel. These calculations are performed to support the planning and strategy for the MARVEL project and will demonstrate the technical viability of the different configurations discussed and help identify where engineered or administrative controls may be necessary. A complete criticality safety analysis and radiation shielding analysis, including validation and contingency and accident analysis must be completed by licensed and authorized personnel before any transfer or storage of MARVEL reactor nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗