Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Towards Integrating Data Quality Assessments and Radiometer Uncertainty for Determining the Expanded Uncertainty of Three-Component Solar Radiation Measurements

Accurate solar irradiance data are fundamental for determining the design and performance characteristics of photovoltaic systems. The uncertainty of solar irradiance measurements depends on many factors including radiometer design, calibration, installation, maintenance, and operational environment. The key contributors to this uncertainty can be classified as the measurement uncertainty of a particular radiometer and the operational uncertainty determined for the time of measurement. Radiometer measurement uncertainty estimates (U R ) can be based on well-established methods used as part of the radiometer calibration process. Estimates of operational uncertainties (U o ) require consideration of additional site-specific factors that affect data quality. A method is needed for establishing the accuracy of solar irradiance data by integrating an existing data quality process and measurement uncertainty estimates for specific radiometers. An algorithm has been developed to integrate data quality analyses and measurement uncertainty estimates for three-component solar irradiance data: global horizontal (total hemispheric) irradiance, direct normal (beam) irradiance, and diffuse horizontal (sky) irradiance collected at one- to 60-minute intervals. The algorithm has been tested using one-minute irradiance measurements. The goal of the project is to distribute a user-friendly software package based on the new algorithm.

data integrity↗

Boundary layer moisture variability at the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic observatory during marine conditions

Abstract. Boundary layer moisture variability at the Eastern North Atlantic (ENA) site during marine conditions is examined at monthly and daily timescales using 5 years of ground-based observations and output from the European Center for Medium range Weather Forecast (ECMWF) reanalysis model. The annual cycle of the mixed-layer total water budgets is presented to estimate the relative contribution of large-scale advection, local moisture tendency, entrainment, and precipitation to balance the moistening due to surface latent heat flux on monthly timescales. When marine conditions prevail, advection of colder and dry air from the north acts as an important moisture sink (∼ 50 % of the overall budget) during fall and winter driving the seasonality of the budget. Entrainment and precipitation contribute to the drying of the boundary layer (∼ 25 % and ∼ 15 % respectively), and the local change in moisture contributes to a small residual part. On a daily temporal scale, moist and dry mesoscale columns of vapor (∼ 10 km) are analyzed during 10 selected days of precipitating stratocumulus clouds. Adjacent moist and dry columns present distinct mesoscale features that are strongly correlated with clouds and precipitation. Dry columns adjacent to moist columns have more frequent and stronger downdrafts immediately below the cloud base. Moist columns have more frequent updrafts, stronger cloud-top cooling, and higher liquid water path and precipitation compared to the dry columns. This study highlights the complex interaction between large-scale and local processes controlling the boundary layer moisture and the importance of spatial distribution of vapor to support convection and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A ATF (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A ATF which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A IR TMIST 3B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗