Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radio Transmitter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

39 records · Page 3

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗