Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ratio of stable isotope concentrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

49 records · Page 3

Interpretation of hydrothermal conditions, production-injection induced effects, and evidence for enhanced geothermal system-type heat exchange in response to >30 years of production at Roosevelt Hot Springs, Utah, USA

The Roosevelt Hot Springs hydrothermal system is located at the base of the Mineral Mountains in southwestern Utah on the eastern side of the Basin and Range. Hydrothermal activity is related to relatively recent bimodal magmatism, and the system is hosted in coarsely crystalline rock made of Oligocene–Miocene granitoids and Precambrian gneiss. The hydrothermal plume covers ~5 km 2 , with a maximum temperature of 268 °C at ~750 m depth, and a vertically extensive fault-fracture mesh east of the Opal Mound fault controls the upflow of hydrothermal fluids. Power generation (currently 38 MWe gross) began in 1984, and up through 2016, four wells were used for fluid production, and three wells were used for edge-field injection. Chemical analyses of produced fluids show that modern reservoir fluid compositions are similar to but more concentrated than those at the start of production, having near-neutral pH, total dissolved solids of 7000–10,000 mg/kg, and ionic ratios of Cl/HCO 3 ~50–100, Cl/SO4 ~50–100, and Na/K ~4–5. Chemical geothermometers indicate equilibration temperatures that mainly range between 240° and 300 °C. Early production induced a steep drop in pressure (~3.0–3.5 MPa), which was accompanied by a 250–300 m lowering of piezometric levels in wells and development of a shallow steam zone across the system. Hydrothermal fluid compositions evolved continuously in response to production-related steam-loss and injection breakthrough, which is reflected by gradual increases in chloride of up to 35% and stable isotope ratios of up to ~2‰δ 18 O and ~10‰δD. Simple mixing model calculations suggest that there has been a significant amount, ~10–20 MW th , of sustained multi-decadal heat mining and enhanced geothermal system (EGS)–type heat transfer by the injectate as it returns to the production zone. Overall, the two factors that have sustained long-term power production (currently 38 MWe gross) are the increased upflow of deep chloride water and, to a lesser extent, the mining of heat at <1 km depth.

58 GEOSCIENCES↗

Radio observations of molecules in the interstellar gas

Since 1968, radio astronomy has made it possible to identify nearly 50 molecules in the dense concentrations of the interstellar gas now generally termed molecular clouds. Most interstellar molecules are familiar stable compounds. However, one-fifth of the discovered species are ions, radicals, and acetylenic carbon chains so reactive in the laboratory that before being detected in space they had rarely been observed or were entirely unknown. The heavy atom backbone of the known interstellar molecules is a linear chain of C, N, O, or S. Si is found in two diatomic molecules. Rings and branched chains are missing. The most readily observed spectral lines of most interstellar molecules correspond to rotational transitions at millimeter wavelengths. These are generally excited by H2 collisions. A number of rare isotopic species are observed in interstellar molecules. Isotopic ratios differing from those on Earth exist, and can in almost all cases be attributed to stellar nucleosynthesis since the formation of the solar system.

Thaddeus, P.↗

The Effects of Experimentally Induced Zircon Annealing on Melt Inclusion-Zircon Geochemistry: A Case Study of Archean Zircon From the Barberton Complex

Crystalline melt inclusions (MIs) in Archean zircons can potentially constrain the evolution of magmatic processes. However, to obtain a homogeneous glassy MI representative of the parent melt, devitrified MIs must be heated at temperatures above the liquidus. Although, it is well known that radiation damaged domains in MI-host zircon undergo temperature-time dependent annealing, the effects of annealing on zircon stable isotope and trace element compositions has received less attention. In this study, we heated multiple aliquots of low-magnetism zircons with relatively low levels of radiation damage (Deff<9.6x1014 α-events/mg) from a 3.304 Ga tonalite gneiss xenolith from the Barberton greenstone belt (sample B87-18; Kamo and Davis, 1994) in an internally-heated pressure vessel at 0.4GPa and 1000–1200°C. Zircons were imaged by SEM (CL, BSE) to determine the zoning patterns around the MIs. The radiation damage preserved in the heated and unheated zircons was determined by measuring broadening of the 3(SiO4) Raman stretching band of zircon (FWHM). Oxygen isotope ratios (δ18O), OH/O ratios, and trace and rare earth element (TREE) concentrations were measured in the zircons and MIs using SIMS. The FWHM and Raman shift of the zircon 3(SiO4) band show a systematic increase of zircon crystallinity with increasing experimental temperature. Despite increasing crystallinity, the 3(SiO4) FWHM is not correlated with δ18O(Zrn) values in the heated or unheated zircons, suggesting that δ18O was not altered by laboratory heating in these low initial radiation damage zircons. FWHM and OH/O are positively correlated in both heated and unheated zircons. The unheated zircons have the largest FWHM and OH/O (OH/OMAX=3.5×10-4) suggesting that H2O was lost during experimental heating due to the progressive annealing of radiation-damaged domains in the zircons. Zircon TREE concentrations and FWHM values are not correlated despite the presence of TREE altered domains in both the heated and unheated zircons. Our results demonstrate that pre-experimental zircon TREE concentrations and δ18O(Zrn) remain intact during laboratory heating of crystalline MIs in zircon, while secondary H2O hosted in radiation damaged domains is partially lost. Thus, MIs in low initial radiation damage Archean zircon are a potentially viable tool for constraining melt compositions.

Joseph P. Gonzalez↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deuterium Isotope Fractionation of Polycyclic Aromatic Hydrocarbons in Meteorites as an Indicator of Interstellar/Protosolar Processing History

The stable isotope composition of soluble and insoluble organic compounds in carbonaceous chondrites can be used to determine the provenance of organic molecules in space. Deuterium enrichment in meteoritic organics could be a residual signal of synthetic reactions occurring in the cold interstellar medium or an indicator of hydrothermal parent-body reactions. δD values have been measured in grains and bulk samples for a wide range of meteorites; however, these reservoirs are highly variable and may have experienced fractionation during thermal and/or aqueous alteration. Among the plethora of organic compounds in meteorites are polycyclic aromatic hydrocarbons (PAHs), which are stable and abundant in carbonaceous chondrites, and their δD ratio may preserve evidence about their formation environment as well as the influence of parent-body processes. This study tests hypotheses about the potential links between PAHs-deuteration concentrations and their formation conditions by examining the δD ratio of PAHs in three CM carbonaceous chondrites representing an aqueous alteration gradient. We use deuterium enrichments in soluble 2–5-ring PAHs as an indicator of either photon-driven deuteration due to unimolecular photodissociation in warm regions of space, gas-phase ion–molecule reactions in cold interstellar regions of space, or UV photolysis in ices. We also test hypothesized reaction pathways during parent-body processing that differ between partially and fully aromatized PAHs. New methodological approaches were developed to extract small, volatile PAHs without fractionation. Our results suggest that meteoritic PAHs could have formed through reactions in cold regions, with possible overprinting of deuterium enrichment during aqueous parent-body alteration, but the data could not rule out PAH alteration in icy mantles as well.

H V Graham↗

A new hypothesis for the origin of Amazonian Dark Earths

Amazonian Dark Earths (ADEs) are unusually fertile soils characterised by elevated concentrations of microscopic charcoal particles, which confer their distinctive colouration. Frequent occurrences of pre-Columbian artefacts at ADE sites led to their ubiquitous classification as Anthrosols (soils of anthropic origin). However, it remains unclear how indigenous peoples created areas of high fertility in one of the most nutrient-impoverished environments on Earth. Here, we report new data from a well-studied ADE site in the Brazilian Amazon, which compel us to reconsider its anthropic origin. The amounts of phosphorus and calcium—two of the least abundant macronutrients in the region—are orders of magnitude higher in ADE profiles than in the surrounding soil. The elevated levels of phosphorus and calcium, which are often interpreted as evidence of human activity at other sites, correlate spatially with trace elements that indicate exogenous mineral sources rather than in situ deposition. Stable isotope ratios of neodymium, strontium, and radiocarbon activity of microcharcoal particles also indicate exogenous inputs from alluvial deposition of carbon and mineral elements to ADE profiles, beginning several thousands of years before the earliest evidence of soil management for plant cultivation in the region. Our data suggest that indigenous peoples harnessed natural processes of landscape formation, which led to the unique properties of ADEs, but were not responsible for their genesis. If corroborated elsewhere, this hypothesis would transform our understanding of human influence in Amazonia, opening new frontiers for the sustainable use of tropical landscapes going forward.

54 ENVIRONMENTAL SCIENCES↗

Natural isotopic compositions of titanium, iron, and nickel observed in commercial fuel pellets – Promising candidate elements for stable isotope tagging

Stable isotope taggants would constitute unique identifiers for nuclear fuel cycle materials, resulting in expedited timelines and high confidence provenance assessments for nuclear forensics investigations. However, reliably identifying and interpreting stable isotope taggants in nuclear materials recovered from outside of regulatory control will largely be predicated on the assumption that the taggant element intrinsic to the untagged nuclear material exhibits natural isotopic ratios. Here, we present high-precision Ti, Fe, and Ni isotope compositions in 13 commercial low-enriched uranium (LEU) fuel pellets to assess the suitability of these transition metals as stable isotope taggants. Our investigations reveal limited isotope variations among the fuel pellets in all three elements, which are consistent with small mass-dependent isotope fractionations, comparable to variations previously reported for natural samples. In practice, isotopically tagged nuclear materials are expected to fall along isotopic mixing lines, since intrinsic background levels of taggant elements dilute the taggant towards natural isotope compositions. Furthermore, the observation that Ti, Fe, and Ni isotope compositions in a suite of LEU fuel pellets are close to or indistinguishable from estimates for the Bulk Silicate Earth demonstrates that a two end-member mixing assumption would be valid for these transition metals, indicating that all three are promising candidate elements for stable isotope tagging. Finally, we present mass balance calculations to quantify isotopic perturbations expected from admixing isotopically anomalous Ti, Fe, and Ni taggants to assess the interplay between elemental and taggant concentrations and find favorable compromises for facilitating successful taggant identification with current analytical methods.

Intentional forensics↗

A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." Here, this study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for determining stable isotope ratios of dissolved organic carbon in interstitial and other natural marine waters

A procedure is described for the analysis of the stable carbon isotopic composition of dissolved organic carbon (DOC) in natural waters from marine and higher-salinity environments. Rapid (less than 5 min) and complete oxidation of DOC is achieved using a modification of previous photochemical oxidation techniques. The CO2 evolved from DOC oxidation can be collected in less than 10 min for isotopic analysis. The procedure is at present suitable for oxidation and collection of 1-5 micromoles of carbon and has an associated blank of 0.1-0.2 micromole of carbon. Complete photochemical oxidation of DOC standards was demonstrated by quantitative recovery of CO2 as measured manometrically. Isotopic analyses of standards by photochemical and high-temperature sealed-tube combustion methods agreed to within 0.3%. Photochemical oxidation of DOC in a representative sediment pore-water sample was also quantitative, as shown by the excellent agreement between the photochemical and sealed-tube methods. The delta 13C values obtained for pore-water DOC using the two methods of oxidation were identical, suggesting that the modified photochemical method is adequate for the isotopically non-fractionated oxidation of pore-water DOC. The procedure was evaluated through an analysis of DOC in pond and pore waters from a hypersaline microbial mat environment. Concentrations of DOC in the water column over the mat displayed a diel pattern, but the isotopic composition of this DOC remained relatively constant (average delta 13C = -12.4%). Pore-water DOC exhibited a distinct concentration maximum in the mat surface layer, and delta 13C of pore-water DOC was nearly 8% lighter at 1.5-2.0-cm depth than in the mat surface layer (0-0.5-cm depth). These results demonstrate the effectiveness of the method in elucidating differences in DOC concentration and delta 13C over biogeochemically relevant spatial and temporal scales. Carbon isotopic analysis of DOC in natural waters, especially pore waters, should be a useful probe of biogeochemical processes in recent environments.

NASA Discipline Exobiology↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1σ) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

Morgan, Leah↗

Changuinola peat soil characteristics and gas emission raw data October 2019

This dataset comprises radiocarbon and geochemical measurements from peat and porewater samples collected across various depths at a site in Bocas del Toro, Panama. The study focuses on carbon cycling dynamics in tropical peatlands by examining carbon isotopic signatures (¹⁴C and ¹³C) and elemental compositions of bulk peat, dissolved organic carbon (DOC), carbon dioxide (CO₂), and methane (CH₄). Key parameters include radiocarbon ages and isotopic ratios (δ¹³C) of bulk peat, concentrations of carbon (%C) and nitrogen (%N), and radiocarbon content of porewater gases and dissolved organic carbon (DOC). The data provide insights into the vertical and spatial distribution of carbon sources and possible preservation and decomposition processes within tropical peat profiles, offering critical information for understanding carbon storage and greenhouse gas emissions in these ecosystems.This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) carbon isotopic signatures (¹⁴C and ¹³C); (5) concentrations of carbon (%C) and nitrogen (%N); (6) radiocarbon content of porewater carbon dioxide (CO₂), and methane (CH₄) ; (7) porewater DOC; (8) bulk peat sampling protocol; (9) porewater sampling protocol; (10) porewater gas collection methods; and (11) gas extraction methods. All files are in .csv format and can be opened with any software that supports this file types.

54 ENVIRONMENTAL SCIENCES↗