Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers

Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR). Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices. The selected channels are dense difference Gaussian channels (DDOG).A body phantom and a head phantom were imaged 50 times at different dose levels to obtain the data needed to assess image quality. The phantoms consisted of uniform backgrounds with low contrast signals embedded at various locations. The tasks the observer model performed included (1) detection of a signal of known location and shape, and (2) detection and localization of a signal of known shape. The employed DDOG channels are based on the response of the human visual system. Performance was assessed using the areas under ROC curves and areas under localization ROC curves. Results: For signal known exactly (SKE) and location unknown/signal shape known tasks with circular signals of different sizes and contrasts, the authors’ task-based measures showed that a FBP equivalent image quality can be achieved at lower dose levels using the IR algorithm. For the SKE case, the range of dose reduction is 50%–67% (head phantom) and 68%–82% (body phantom). For the study of location unknown/signal shape known, the dose reduction range can be reached at 67%–75% for head phantom and 67%–77% for body phantom case. These results suggest that the IR images at lower dose settings can reach the same image quality when compared to full dose conventional FBP images. Conclusions: The work presented provides an objective way to quantitatively assess the image quality of a newly introduced CT IR algorithm. The performance of the model observers using the IR images was always higher than that seen using the FBP images in the authors’ SKE and SKE location unknown detection tasks. To achieve a FBP-equivalent image quality in CT systems, the authors can lower the radiation dose by using this IR image reconstruction algorithm. Further studies are warranted using clinical data and human observer to validate these results for more complicated and realistic tasks.

60 APPLIED LIFE SCIENCES↗

Evaluation of the performance of event reconstruction algorithms in the JSNS 2 experiment using a 252 Cf calibration source

JSNS 2 investigates short-baseline neutrino oscillations using a 24-meter baseline and a 17-tonne Gd-loaded liquid scintillator target. Accurate event-reconstruction algorithms are crucial for analyzing experimental data. The algorithms undergo meticulous validation through calibration with a 252 Cf source. This paper outlines the methodology and evaluates the reconstruction performance, focusing on neutrino interactions up to approximately 50 MeV for sterile neutrino searches. Both 252 Cf and Michel electron events are studied to evaluate reconstruction accuracy. The analysis concludes that the uncertainty of the fiducial volume, with an appropriate correction, is much less than the requirement of JSNS 2 requirement (10%). Furthermore, the energy resolution is measured to be 3.3 ± 0.1% for the Michel electron endpoint and 4.3 ± 0.1% for the n-Gd peak in the central region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Three-Dimensional Reconstruction Algorithm for Scanning Transmission Electron Microscopy Data from a Single Sample Orientation

Abstract Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data. We apply the approach to a lead iridate, PbIrO, and yttrium-stabilized zirconia, YZrO, heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction. We demonstrate that Pb–Ir atomic columns are visible in the uppermost layers of the reconstructed volume. We compare this approach to the alternative techniques of depth sectioning using differential phase contrast scanning transmission electron microscopy (DPC-STEM) and multislice ptychographic reconstruction.

47 OTHER INSTRUMENTATION↗

Comparison of 3-D Bubble Reconstruction Algorithms

Obtaining 3-D bubble shape is important in studying bubble dynamics in two-phase flows, as well as in conducting high-fidelity measurement for code validation applications. With accurate shape information of individual bubbles, the time-averaged parameters including void fraction, interfacial area concentration and Sauter mean diameter can be obtained precisely. Such information will also benefit the development of advanced models of hydrodynamic forces such as the drag force and lift force, which are sensitive to the shape and size of bubbles. Limited by the optical property of gas-liquid system, the silhouette of a bubble along the camera axis is what one can obtain from typical high speed imaging systems. Assumptions have to be made to obtain the 3-D bubble shape from the 2-D images. In this paper, three different bubble reconstruction algorithms, using one or two camera views, are examined to assess their performances in the reconstruction process. (authors)

42 ENGINEERING↗

Iterative Stress Reconstruction Algorithm to Estimate Three-Dimensional Residual Stress Fields in Manufactured Components

Residual stress (RS) significantly impacts the mechanical performance of components. Measurement of RS often provides incomplete data in terms of components of stress and spatial density. Employing such fields in finite element simulations results in significant modification of the field to achieve equilibrium and compatibility among strains. To overcome this, an iterative stress reconstruction algorithm (ISRA) is developed to estimate 3D RS fields that satisfy equilibrium, are stress component-wise complete, and represent the characterized data sampled. An Al 7075-T651 plate and an additively manufactured (AM) A36 steel wall are considered for RS reconstruction using measurement data from the literature. A maximum variation of ~2.5 MPa in the Al plate, and ~10 MPa in the steel wall are observed between the reconstructed and measured stresses. Furthermore, unknown stress components emerge and reach significant magnitudes (upto ~2.3 MPa in the Al plate and ~45 MPa in the AM wall) during ISRA. Indeed, it is found that minor errors in measurement or data processing are eliminated through the physical requirements during ISRA. Employing a reconstructed RS field is hence not just more accurate given its compatibility, but it additionally corrects for minor errors in measurement. Furthermore, it is found that spatially dense measurement data result in convergence with fewer iterations. Finally, although ISRA yields a nonunique solution dependent on boundary conditions, measurement errors, fitting errors, and mesh density, it accommodates for uncertainties and inaccuracies in measurement, as opposed to failing to reach a physically realistic converged solution.

42 ENGINEERING↗

Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry

Purpose: In this article, the image quality of reconstructed volumes by four algorithms for digital tomosynthesis, applied in the case of breast, is investigated using synchrotron radiation. Methods: An angular data set of 21 images of a complex phantom with heterogeneous tissue-mimicking background was obtained using the SYRMEP beamline at ELETTRA Synchrotron Light Laboratory, Trieste, Italy. The irradiated part was reconstructed using the multiple projection algorithm (MPA) and the filtered backprojection with ramp followed by hamming windows (FBR-RH) and filtered backprojection with ramp (FBP-R). Additionally, an algorithm for reducing the noise in reconstructed planes based on noise mask subtraction from the planes of the originally reconstructed volume using MPA (MPA-NM) has been further developed. The reconstruction techniques were evaluated in terms of calculations and comparison of the contrast-to-noise ratio (CNR) and artifact spread function. Results: It was found that the MPA-NM resulted in higher CNR, comparable with the CNR of FBP-RH for high contrast details. Low contrast objects are well visualized and characterized by high CNR using the simple MPA and the MPA-NM. In addition, the image quality of the reconstructed features in terms of CNR and visual appearance as a function of the initial number of projection images and the reconstruction arc was carried out. Slices reconstructed with more input projection images result in less reconstruction artifacts and higher detail CNR, while those reconstructed from projection images acquired in reduced angular range causes pronounced streak artifacts. Conclusions: Of the reconstruction algorithms implemented, the MPA-NM and MPA are a good choice for detecting low contrast objects, while the FBP-RH, FBP-R, and MPA-NM provide high CNR and well outlined edges in case of microcalcifications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Acceptability of Iterative Reconstruction Algorithms in Head CT: An Assessment of Sinogram Affirmed Iterative Reconstruction (SAFIRE) vs. Filtered Back Projection (FBP) Using Phantoms

Computed tomography (CT) is the primary imaging investigation for many neurologic conditions with a proportion of patients incurring cumulative doses. Iterative reconstruction (IR) allows dose optimization, but head CT presents unique image quality complexities and may lead to strong reader preferences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the Tracker Seeded Reconstruction Algorithm

• Mu2e has two separate track-search algorithms usedin online track reconstruction • Reconstruction is tested using Monte Carlo simulation • I am investigating the background events triggered bythe TrkPatRecalgorithm

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extensive analysis of reconstruction algorithms for DESI 2024 baryon acoustic oscillations

Reconstruction of the baryon acoustic oscillation (BAO) signal has been a standard procedure in BAO analyses over the past decade and has helped to improve the BAO parameter precision by a factor of ∼2 on average. The Dark Energy Spectroscopic Instrument (DESI) BAO analysis for the first year (DR1) data uses the “standard” reconstruction framework, in which the displacement field is estimated from the observed density field by solving the linearized continuity equation in redshift space, and galaxy and random positions are shifted in order to partially remove non-linearities. There are several approaches to solving for the displacement field in real survey data, including the multigrid (MG), iterative Fast Fourier Transform (iFFT), and iterative Fast Fourier Transform particle (iFFTP) algorithms. In this work, we analyze these algorithms and compare them with various metrics including two-point statistics and the displacement itself using realistic DESI mocks. We focus on three representative DESI samples, the emission line galaxies (ELG), quasars (QSO), and the bright galaxy sample (BGS), which cover the extreme redshifts and number densities, and potential wide-angle effects. We conclude that the MG and iFFT algorithms agree within 0.4% in post-reconstruction power spectrum on BAO scales with the RecSym convention, which does not remove large-scale redshift space distortions (RSDs), in all three tracers. The RecSym convention appears to be less sensitive to displacement errors than the RecIso convention, which attempts to remove large-scale RSDs. However, iFFTP deviates from the first two; thus, we recommend against using iFFTP without further development. In addition, we provide the optimal settings for reconstruction for five years of DESI observation. The analyses presented in this work pave the way for DESI DR1 analysis as well as future BAO analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Do Epistemic Uncertainties Allow for Replacing Microstructural Experiments with Reconstruction Algorithms?

A novel problem in computational materials modeling is addressed: “Are the computational microstructure reconstruction techniques reliable enough to replace experiments?” Here, “reliable” computations are associated with producing “expected” reconstructions that are adequately close to the experimental data. The output of computational techniques can deviate from the experimental measurements because of the epistemic uncertainties in the algorithms. In this work, an analytical formulation for quantification of epistemic uncertainties in a microstructure reconstruction algorithm based on Markov random field is presented. The method is used to predict the large-scale spatial distribution of a microstructure given an experimental input measured over a small spatial domain. However, small variations are observed on the microstructural features of the synthesized samples due to the Markov random field algorithm. The proposed analytical technique aims to quantify these uncertainties and estimate their propagation to the macroscale material properties to provide a significant understanding on how reliable it is to replace the experiments with the Markov random field model to predict microstructural maps over large spatial domains.

97 MATHEMATICS AND COMPUTING↗

Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology

Purpose: Iterative reconstruction (IR) reduces noise, thereby allowing dose reduction in computed tomography (CT) while maintaining comparable image quality to filtered back-projection (FBP). This study sought to characterize image quality metrics, delineation, dosimetric assessment, and other aspects necessary to integrate IR into treatment planning. Methods: CT images (Brilliance Big Bore v3.6, Philips Healthcare) were acquired of several phantoms using 120 kVp and 25–800 mAs. IR was applied at levels corresponding to noise reduction of 0.89–0.55 with respect to FBP. Noise power spectrum (NPS) analysis was used to characterize noise magnitude and texture. CT to electron density (CT-ED) curves were generated over all IR levels. Uniformity as well as spatial and low contrast resolution were quantified using a CATPHAN phantom. Task specific modulation transfer functions (MTF{sub task}) were developed to characterize spatial frequency across objects of varied contrast. A prospective dose reduction study was conducted for 14 patients undergoing interfraction CT scans for high-dose rate brachytherapy. Three physicians performed image quality assessment using a six-point grading scale between the normal-dose FBP (reference), low-dose FBP, and low-dose IR scans for the following metrics: image noise, detectability of the vaginal cuff/bladder interface, spatial resolution, texture, segmentation confidence, and overall image quality. Contouring differences between FBP and IR were quantified for the bladder and rectum via overlap indices (OI) and Dice similarity coefficients (DSC). Line profile and region of interest analyses quantified noise and boundary changes. For two subjects, the impact of IR on external beam dose calculation was assessed via gamma analysis and changes in digitally reconstructed radiographs (DRRs) were quantified. Results: NPS showed large reduction in noise magnitude (50%), and a slight spatial frequency shift (∼0.1 mm{sup −1}) with application of IR at L6. No appreciable changes were observed for CT-ED curves between FBP and IR levels [maximum difference ∼13 HU for bone (∼1% difference)]. For uniformity, differences were ∼1 HU between FBP and IR. Spatial resolution was well conserved; the largest MTF{sub task} decrease between FBP and IR levels was 0.08 A.U. No notable changes in low-contrast detectability were observed and CNR increased substantially with IR. For the patient study, qualitative image grading showed low-dose IR was equivalent to or slightly worse than normal dose FBP, and is superior to low-dose FBP (p < 0.001 for noise), although these did not translate to differences in CT number, contouring ability, or dose calculation. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using the most aggressive IR level [−1.2 ± 4.9 HU (range: −17.6–12.5 HU)]. No clinically significant contour differences were found between IR and FBP, with OIs and DSCs ranging from 0.85 to 0.95. Negligible changes in dose calculation were observed. DRRs preserved anatomical detail with <2% difference in intensity from FBP combined with aggressive IRL6. Conclusions: These results support integrating IR into treatment planning. While slight degradation in edges and shift in texture were observed in phantom, patient results show qualitative image grading, contouring ability, and dosimetric parameters were not adversely affected.

60 APPLIED LIFE SCIENCES↗

An efficient reconstruction algorithm for diffusion on triangular grids using the nodal discontinuous Galerkin method

High-energy-density (HED) hydrodynamics studies such as those relevant to inertial confinement fusion and astrophysics require highly disparate densities, temperatures, viscosities, and other diffusion parameters over relatively short spatial scales. This presents a challenge for high-order accurate methods to effectively resolve the hydrodynamics at these scales, particularly in the presence of highly disparate diffusion. A significant volume of engineering and physics applications use an unstructured discontinuous Galerkin (DG) method developed based on the finite element mesh generation and algorithmic framework. This work discusses the application of an affine reconstructed nodal DG method for unstructured grids of triangles. Solving the diffusion terms in the DG method is non-trivial due to the solution representations being piecewise continuous. Hence, the diffusive flux is not defined on the interface of elements. The proposed numerical approach reconstructs a smooth solution in a parallelogram that is enclosed by the quadrilateral formed by two adjacent triangle elements. The interface between these two triangles is the diagonal of the enclosed parallelogram. Similar to triangles, the mapping of parallelograms from a physical domain to a reference domain is an affine mapping, which is necessary for an accurate and efficient implementation of the numerical algorithm. Thus, all computations can still be performed on the reference domain, which promotes efficiency in computation and storage. This reconstruction does not make assumptions on choice of polynomial basis. Reconstructed DG algorithms have previously been developed for modal implementations of the convection–diffusion equations. However, to the best of the authors’ knowledge, this is the first practical guideline that has been proposed for applying the reconstructed algorithm on a nodal discontinuous Galerkin method with a focus on accuracy and efficiency. As a result, the algorithm is demonstrated on a number of benchmark cases as well as a challenging substantive problem in HED hydrodynamics with highly disparate diffusion parameters.

Computational efficiency↗

Multi-track reconstruction algorithms in the Mu2e experiment

The Mu2e experiment, under construction at Fermilab, will search for the neutrino-less coherent µ−N → e−N conversion in the field of a 27 Al nucleus, a CLFV process. While the main goal of the experiment is to reconstruct the conversion electron, i.e., an event with a single track, there are motivations to develop an efficient tracking algorithm for reconstructing more simultaneous tracks. This could better constrain the background generated by p¯-annihilation in the Al target and search for Beyond the Standard Model processes. In this paper, we present the algorithms designed to reconstruct multi-particle events.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Trigger and Reconstruction Algorithms for the Japanese Experiment Module- Extreme Universe Space Observatory (JEM-EUSO)

The JEM-EUSO collaboration intends to study high energy cosmic ray showers using a large downward looking telescope mounted on the Japanese Experiment Module of the International Space Station. The telescope focal plane is instrumented with approx.300k pixels operating as a digital camera, taking snapshots at approx. 1MHz rate. We report an investigation of the trigger and reconstruction efficiency of various algorithms based on time and spatial analysis of the pixel images. Our goal is to develop trigger and reconstruction algorithms that will allow the instrument to detect energies low enough to connect smoothly to ground-based observations.

Adams, J. H., Jr.↗

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗

Optical tomography reconstruction algorithm with the finite element method: An optimal approach with regularization tools

Highlights: •New strategies to improve the accuracy of the reconstruction through mesh and finite element parameterization. •Use of gradient filtering through an alternative inner product within the adjoint method. •An integral form of the cost function is used to make the reconstruction compatible with all finite element formulations, continuous and discontinuous. •Gradient-based algorithm with the adjoint method is used for the reconstruction. -- Abstract: Optical tomography is mathematically treated as a non-linear inverse problem where the optical properties of the probed medium are recovered through the minimization of the errors between the experimental measurements and their predictions with a numerical model at the locations of the detectors. According to the ill-posed behavior of the inverse problem, some regularization tools must be performed and the Tikhonov penalization type is the most commonly used in optical tomography applications. This paper introduces an optimized approach for optical tomography reconstruction with the finite element method. An integral form of the cost function is used to take into account the surfaces of the detectors and make the reconstruction compatible with all finite element formulations, continuous and discontinuous. Through a gradient-based algorithm where the adjoint method is used to compute the gradient of the cost function, an alternative inner product is employed for preconditioning the reconstruction algorithm. Moreover, appropriate re-parameterization of the optical properties is performed. These regularization strategies are compared with the classical Tikhonov penalization one. It is shown that both the re-parameterization and the use of the Sobolev cost function gradient are efficient for solving such an ill-posed inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Compressed Sensing-based Image Reconstruction Algorithm for Solar Flare X-Ray Observations

One way of imaging X-ray emission from solar flares is to measure Fourier components of the spatial X-ray source distribution. We present a new compressed sensing-based algorithm named VIS-CS, which reconstructs the spatial distribution from such Fourier components. We demonstrate the application of the algorithm on synthetic and observed solar flare X-ray data from the Reuven Ramaty High Energy Solar Spectroscopic Imager satellite and compare its performance with existing algorithms. VIS-CS produces competitive results with accurate photometry and morphology, without requiring any algorithm- and X-ray-source-specific parameter tuning. Its robustness and performance make this algorithm ideally suited for the generation of quicklook images or large image cubes without user intervention, such as for imaging spectroscopy analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-track reconstruction algorithm in the Mu2e experiment

The Mu2e experiment, under construction at Fermilab, will search for the neutrino-less coherent $\mu^-N\rightarrow e^-N$ conversion in the field of a $^{27}$Al nucleus. Such a process violates lepton flavor conservation. About $60\%$ of muons stopped by an $^{27}$Al nucleus will undergo nuclear capture, while about $40\%$ will decay in orbit. To quantify the conversion probability, we define $R_{\mu e}$, which is given by the ratio between the $\mu^-\rightarrow e^-$ conversion rate and the nuclear capture rate [1]: \begin{equation} R_{\mu e}= \frac{\Gamma\left(\mu^- + N\left(Z,A\right)\rightarrow e^- + N\left(Z,A\right)\right)}{\Gamma\left(\mu^- + N\left(Z,A\right)\rightarrow \nu^-_\mu + N\left(Z-1,A\right)\right)}\,. \end{equation} The upper limit on $R_{\mu e}$ is $7\cdot 10^{-13}$ at $90\%$ CL, set by the SINDRUM II experiment~\cite{SINDRUM II:limit}. The goal of the Mu2e experiment is to reach a sensitivity on $R_{\mu e}$ of $8\cdot 10^{-17}$ at $90\%$ CL. This represents a four-order of magnitude improvement over the current experimental limit. Mu2e will take its first data in 2027. The signature for the muon conversion is a monochromatic electron of $104.97$~\si{\mega\eV}/c, an energy slightly below the muon rest mass. While the main experiment goal is to reconstruct the conversion electron, i.e., an event with a single track, there are motivations to develop an efficient tracking algorithm for reconstructing more simultaneous tracks. This could better constrain the background generated by $p\bar{p}$-annihilation in the Al target and to search for other Beyond the Standard Model processes. In this paper, we present an algorithm designed to reconstruct multi-particle events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗