Search NASA⌕ Search

SEARCH · Search NASA

Results for “Recovery Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Urine Pretreatment Configuration and Test Results for Space Applications

Pretreatment of urine using Oxone and sulfuric acid is baselined in the International Space Station (ISS) waste water reclamation system to control odors, fix urea and control microbial growth. In addition, pretreatment is recommended for long term flight use of urine collection and two phase separation to reduce or eliminate fouling of the associated hardware and plumbing with urine precipitates. This is important for ISS application because the amount of maintenance time for cleaning and repairing hardware must be minimized. This paper describes the development of a chemical pretreatment system based on solid tablet shapes which are positioned in the urine collection hose and are dissolved by the intrained urine at the proper ratio of pretreatment to urine. Building upon the prior success of the developed and tested solid Oxone tablet a trade study was completed to confirm if a similar approach, or alternative, would be appropriate for the sulfuric acid injection method. In addition, a recommended handling and packaging approach of the solid tablets for long term, safe and convenient use on ISS was addressed. Consequently, the solid tablet concept with suitable packaging was identified as the Urine Pretreat / Prefilter Assembly (UPPA). Testing of the UPPA configuration confirmed the disolution rates and ratios required by ISS were achieved. This testing included laboratory controlled methods as well as a 'real world' test evaluation that occurred during the 150 day Stage 10 Water Recovery Test (WRT) conducted at NASA Marshall Space Flight Center (MSFC).

Howard, Stanley G.↗

Hollow Fiber Membrane Bioreactor Systems for Wastewater Processing: Effects of Environmental Stresses Including Dormancy Cycling and Antibiotic Dosing

Membrane-aerated biofilm reactors (MABRs) have been studied for a number of years as an alternate approach for treating wastewater streams during space exploration. While the technology provides a promising pre-treatment for lowering organic carbon and nitrogen content without the need for harsh stabilization chemicals, several challenges must be addressed before adoption of the technology in future missions. One challenge is the transportation of bioreactors containing intact, active biofilms as a means for rapid start-up on the International Space Station or beyond. Similarly, there could be a need for placing these biological systems into a dormant state for extended periods when the system is not in use, along with the ability for rapid restart. Previous studies indicated that there was little influence of storage condition (4 or 25 C, with or without bulk fluid) on recovery of bioreactors with immature biofilms (48 days old), but that an extensive recovery time was required (20+ days). Bioreactors with fully established biofilms (13 months) were able to recover from a 7-month dormancy within 4 days (approximately 1 residence). Further dormancy and recovery testing is presented here that examines the role of biofilm age on recovery requirements, repeated dormancy cycle capabilities, and effects of long-duration dormancy cycles (8-9 months) on HFMB systems. Another challenge that must be addressed is the possibility of antibiotics entering the wastewater stream. Currently, for most laboratory tests of biological water processors, donors providing urine may not contribute to the study when taking antibiotics because the effects on the system are yet uncharacterized. A simulated urinary tract infection event, where an opportunistic, pathogenic organism, E. coli, was introduced to the HFMBs followed by dosing with an antibiotic, ciprofloxacin, was completed to study the effect of the antibiotic on reactor performance and to also examine the development of antibiotic-resistant communities within the system.

Bioreactor Systems↗

Correlation between Mechanical Behavior and Actuator-type Performance of Ni-Ti-Pd High-temperature Shape Memory Alloys

High-temperature shape memory alloys in the NiTiPd system are being investigated as lower cost alternatives to NiTiPt alloys for use in compact solid-state actuators for the aerospace, automotive, and power generation industries. A range of ternary NiTiPd alloys containing 15 to 46 at.% Pd has been processed and actuator mimicking tests (thermal cycling under load) were used to measure transformation temperatures, work behavior, and dimensional stability. With increasing Pd content, the work output of the material decreased, while the amount of permanent strain resulting from each load-biased thermal cycle increased. Monotonic isothermal tension testing of the high-temperature austenite and low temperature martensite phases was used to partially explain these behaviors, where a mismatch in yield strength between the austenite and martensite phases was observed at high Pd levels. Moreover, to further understand the source of the permanent strain at lower Pd levels, strain recovery tests were conducted to determine the onset of plastic deformation in the martensite phase. Consequently, the work behavior and dimensional stability during thermal cycling under load of the various NiTiPd alloys is discussed in relation to the deformation behavior of the materials as revealed by the strain recovery and monotonic tension tests.

Bigelow, Glen S.↗

ORBITAL ANGULAR MOMENTUM BEAMS RESEARCH USING A FREE-ELECTRON LASER OSCILLATOR

We present a Fixed-Field-Alternating (FFA) permanent magnet racetrack electron accelerator with energy range between 10-60 GeV for the future LHeC. Electron beam is brought back to the linac by the single beam line without requiring electric power REDUCING estimated wall power of 100 MW in the present LHeC design to a negligible power for arcs as the permanent magnets are used. The design is based on experience from the very successful commissioning of the Cornell University and Brookhaven National Laboratory Energy Recovery Test Accelerator ? ?CBETA?. The proposal supports sustainability efforts for LHeC by making a 'green' accelerator. It is an energy recovery linac with 99.9% energy efficiency and reduces the power consumption by using small permanent magnets. The FFA non-linear gradient design is a racetrack shape, where, as in the CBETA, the arcs are matched by adiabatic transition to the two (LHeC) or multiple straight sections. Two 10 GeV superconducting linacs are placed on both sides of the Interaction Region (IR) significantly reducing the power of synchrotron radiation loss.

Trbojevic, D.↗

Large-scale Gravitational Lens Modeling with Bayesian Neural Networks for Accurate and Precise Inference of the Hubble Constant

We investigate the use of approximate Bayesian neural networks (BNNs) in modeling hundreds of time delay gravitational lenses for Hubble constant (H 0 ) determination. Here, our BNN was trained on synthetic Hubble Space Telescope quality images of strongly lensed active galactic nuclei with lens galaxy light included. The BNN can accurately characterize the posterior probability density functions (PDFs) of model parameters governing the elliptical power-law mass profile in an external shear field. We then propagate the BNN-inferred posterior PDFs into an ensemble H 0 inference, using simulated time delay measurements from a plausible dedicated monitoring campaign. Assuming well-measured time delays and a reasonable set of priors on the environment of the lens, we achieve a median precision of 9.3% per lens in the inferred H 0 . A simple combination of a set of 200 test lenses results in a precision of 0.5 km s –1 Mpc –1 (0.7%), with no detectable bias in this H 0 recovery test. The computation time for the entire pipeline—including the generation of the training set, BNN training and H0 inference—translates to 9 minutes per lens on average for 200 lenses and converges to 6 minutes per lens as the sample size is increased. Being fully automated and efficient, our pipeline is a promising tool for exploring ensemble-level systematics in lens modeling for H 0 inference.

79 ASTRONOMY AND ASTROPHYSICS↗

Microbiological test results of the environmental control and life support systems vapors compression distillation subsystem recycle tank components following various pretreatment protocols

Microbiological samples were collected from the recycle tank of the vapor compression distillation (VCD) subsystem of the water recovery test at NASA MSFC following a 68-day run. The recycle tank collects rejected urine brine that was pretreated with a commercially available oxidant (Oxone) and sulfuric acid and pumps it back to the processing component of the VCD. Samples collected included a water sample and two swab samples, one from the particulate filter surface and a second from material floating on the surface of the water. No bacteria were recovered from the water sample. Both swab samples contained a spore-forming bacterium, Bacillus insolitus. A filamentous fungus was isolated from the floating material. Approximately 1 month after the pretreatment chemicals were changed to sodium hypochlorite and sulfuric acid, a swab of the particulate filter was again analyzed for microbial content. One fungus was isolated, and spore-forming bacteria were observed. These results indicate the inability of these pretreatments to inhibit surface attachment. The implications of the presence of these organisms are discussed.

Huff, Tim↗

Sample test array and recovery (STAR) platform at the National Ignition Facility

We have developed the Sample Test Array and Recovery (STAR) platform for the National Ignition Facility (NIF) for studying the thermal and hydrodynamic responses of materials in extreme environments. The STAR platform expands the range of obtainable fluences and quadruples the rate that materials experiments can be conducted at the NIF. Example configurations are demonstrated for fluences spanning 0.56–34 J/cm 2 with environmental isolation for post-shot material recovery and inspection and up to 1740 J/cm 2 without isolation, with surface heating rates of up to 2 × 10 14 K/s. Lastly, an example experiment involving thermally driven shock and spallation of aluminum alloy 7075 is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parachute Line Hook Includes Integral Loop Expander

Parachute packing simplified with modified line hook. One person packs parachutes for test recovery vehicles faster than previously two-person team. New line hook includes expander that opens up two locking loops so parachute lines are pulled through them. Parachutes are packed at high pressure to be compressed into limited space available in test vehicles.

Bayless, G. B.↗

Microbiological test results using three urine pretreatment regimes with 316L stainless steel

Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

Huff, Timothy L.↗

Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and the recovered signals can be further classified as planet candidates or false positives in the exact same manner as detections from the nominal (i.e., observed) pipeline run (Twicken et al., 2016, Thompson et al., in preparation). To date, the PLTI test has been the standard means of measuring pipeline completeness averaged over large samples of targets (Christiansen et al., 2015, 2016; Christiansen, 2017). However, since the PLTI test uses only one injection per target, it does not elucidate individual-target variations in pipeline completeness due to differences in stellar properties or astrophysical variability. Thus, we developed the FLTI test to provide a numerically efficient way to fully map individual targets and explore the performance of the pipeline in greater detail. The FLTI tests thereby allow a thorough validation of the pipeline completeness models (such as window function (Burke and Catanzarite, 2017a), detection efficiency (Burke Catanzarite, 2017b), etc.) across the spectrum of Kepler targets (i.e., various astrophysical phenomena and differences in instrumental noise). Tests during development of the FLTI capability revealed that there are significant target-to-target variations in the detection efficiency.

DR25↗

Optically stimulated luminescence dosimetry on mobile phone back protective glass

Protective glasses from the back of modern smartphones were tested as potential emergency dosimeters using optically stimulated luminescence (OSL). The glasses were shown to exhibit several favorable dosimetric properties including a strong sensitivity to radiation, a linear dose-response relationship from 0.1 to 8 Gy, a 3% reproducibility, and a minimum detectable dose in the low tens of milligray, even after significant fading. The OSL signal was observed to lose ~78% and ~90% of the original intensity over 1 h and 1 week, respectively; however, a fading curve was developed to correct for any such signal loss. A dose-recovery test demonstrated that reconstructed doses were capable of accuracies within 20%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recovering the Star Formation Histories of Recently Quenched Galaxies: The Impact of Model and Prior Choices

Accurate models of the star formation histories (SFHs) of recently quenched galaxies can provide constraints on when and how galaxies shut down their star formation. The recent development of nonparametric SFH models promises the flexibility required to make these measurements. However, model and prior choices significantly affect derived SFHs, particularly for post-starburst galaxies (PSBs), which have sharp changes in their recent SFH. In this paper, we create mock PSBs, then use the Prospector SED fitting software to test how well four different SFH models recover key properties. We find that a two-component parametric model performs well for our simple mock galaxies, but is sensitive to model mismatches. The fixed- and flexible-bin nonparametric models included in Prospector are able to rapidly quench a major burst of star formation, but systematically underestimate the post-burst age by up to 200 Myr. We develop a custom SFH model that allows for additional flexibility in the recent SFH. Our flexible nonparametric model is able to constrain post-burst ages with no significant offset and just ~90 Myr of scatter. Our results suggest that while standard nonparametric models are able to recover first-order quantities of the SFH (mass, SFR, average age), accurately recovering higher-order quantities (burst fraction, quenching time) requires careful consideration of model flexibility. These mock recovery tests are a critical part of future SFH studies. Finally, we show that our new, public SFH model is able to accurately recover the properties of mock star-forming and quiescent galaxies and is suitable for broader use in the SED fitting community. https://github.com/bd-j/prospector

79 ASTRONOMY AND ASTROPHYSICS↗

Accounting for Sustainability and Performance: Contrasting Effects of PET-Derived Modifiers on Asphalt Durability

The valorization of waste plastics in roadway infrastructure requires careful balance between sustainability and performance, as ineffective modifiers may incur both environmental and financial costs. This study shows that two modifiers derived from the same waste plastic source (PET)-DOTP (N1,N4-(dioctyl)terephthalamide) and HETP (N1,N4-Bis(2-hydroxyethyl)terephthalamide)-exhibit opposite effects on asphalt properties, despite having nearly the same carbon footprint. DOTP improves elastic recovery in multiple creep recovery tests (MCRT), while HETP increases strain accumulation and reduces elasticity. Density functional theory (DFT) shows that DOTP's molecular structure can disperse well in bitumen mixtures by binding to both polar and non-polar components. In contrast, HETP binds only to the binder's polar sites, lacking adequate dispersion. This increases the risk of aggregation of polar compounds in the bitumen mixture, resulting in a more deformation-prone binder. A techno-economic analysis highlights trade-offs between sustainability and performance in industrial-scale synthesis. This study advocates for applying first-principles thinking in material design, coupled with experimental validation, to engineer plastic waste-derived additives that achieve both performance and sustainability goals.

36 MATERIALS SCIENCE↗

Sub-m s−1 upper limits from a deep HARPS-N radial-velocity search for planets orbiting HD 166620 and HD 144579

ABSTRACT Minimizing the impact of stellar variability in radial velocity (RV) measurements is a critical challenge in achieving the 10 cm s−1 precision needed to hunt for Earth twins. Since 2012, a dedicated programme has been underway with HARPS-N, to conduct a blind RV rocky planets search (RPS) around bright stars in the Northern hemisphere. Here we describe the results of a comprehensive search for planetary systems in two RPS targets, HD 166620 and HD 144579. Using wavelength-domain line-profile decorrelation vectors to mitigate the stellar activity and performing a deep search for planetary reflex motions using a trans-dimensional nested sampler, we found no significant planetary signals in the data sets of either of the stars. We validated the results via data-splitting and injection recovery tests. Additionally, we obtained the 95th percentile detection limits on the HARPS-N RVs. We found that the likelihood of finding a low-mass planet increases noticeably across a wide period range when the inherent stellar variability is corrected for using scalpelsU-vectors. We are able to detect planet signals with Msin i ≤ 1 M⊕ for orbital periods shorter than 10 d. We demonstrate that with our decorrelation technique, we are able to detect signals as low as 54 cm s−1, which brings us closer to the calibration limit of 50 cm s−1 demonstrated by HARPS-N. Therefore, we show that we can push down towards the RV precision required to find Earth analogues using high-precision radial velocity data with novel data-analysis techniques.

Anna John, A. (ORCID:0000000217156939)↗

Precise cosmological constraints from BOSS galaxy clustering with a simulation-based emulator of the wavelet scattering transform

For this study, we perform a reanalysis of the BOSS CMASS DR12 galaxy dataset using a simulation-based emulator for the wavelet scattering transform (WST) coefficients. Moving beyond our previous works, which laid the foundation for the first galaxy clustering application of this estimator, we construct a neural net-based emulator for the cosmological dependence of the WST coefficients and the 2-point correlation function multipoles, trained from the state-of-the-art suite of abacussummit simulations combined with a flexible halo occupation distribution (HOD) galaxy model. In order to confirm the accuracy of our pipeline, we subject it to a series of thorough internal and external mock parameter recovery tests, before applying it to reanalyze the CMASS observations in the redshift range 0.46 < z < 0.57. We find that a joint WST+2-point correlation function likelihood analysis allows us to obtain marginalized 1⁢σ errors on the Λ⁢ CDM parameters that are tighter by a factor of 2.5–6, compared to the 2-point correlation function, and by a factor of 1.4–2.5 compared to the WST-only results. This corresponds to a competitive 0.9%, 2.3% and 1% level of determination for parameters ω c , ⁢σ 8 &n s , respectively, and also to a 0.7% and 2.5% constraint on derived parameters h and ƒ⁡(z)⁢⁢σ 8 ⁡(z), in agreement with the Planck 2018 results. Our results reaffirm the constraining power of the WST and highlight the exciting prospect of employing higher-order statistics in order to fully exploit the power of upcoming stage-IV spectroscopic observations.

79 ASTRONOMY AND ASTROPHYSICS↗

A Search for FeH in Hot-Jupiter Atmospheres with High-dispersion Spectroscopy

Most of the molecules detected thus far in exoplanet atmospheres, such as water and CO, are present for a large range of pressures and temperatures. In contrast, metal hydrides exist in much more specific regimes of parameter space, and so can be used as probes of atmospheric conditions. Iron hydride (FeH) is a dominant source of opacity in low-mass stars and brown dwarfs, and evidence for its existence in exoplanets has recently been observed at low resolution. We performed a systematic search of archival CARMENES near-infrared data for signatures of FeH during transits of 12 exoplanets. These planets span a large range of equilibrium temperatures (600 ≲ T eq ≲ 4000 K) and surface gravities (2.5 ≲ logg ≲ 3.5). We did not find a statistically significant FeH signal in any of the atmospheres, but obtained potential low-confidence signals (signal-to-noise ratio ~ 3) in two planets, WASP-33b and MASCARA-2b. Previous modeling of exoplanet atmospheres indicate that the highest volume mixing ratios (VMRs) of 10 -7 to 10 -9 are expected for temperatures between 1800 and 3000 K and log g≳3. The two planets for which we find low-confidence signals are in the regime where strong FeH absorption is expected. We performed injection and recovery tests for each planet and determined that FeH would be detected in every planet for VMRs &NestedGreaterGreater;10 -6 , and could be detected in some planets for VMRs as low as 10 -9.5 . Additional observations are necessary to conclusively detect FeH and assess its role in the temperature structures of hot-Jupiter atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

A Decade of Radial-velocity Monitoring of Vega and New Limits on the Presence of Planets

We present an analysis of 1524 spectra of Vega spanning 10 yr, in which we search for periodic radial-velocity variations. A signal with a periodicity of 0.676 day and a semi-amplitude of ∼10 m s{sup −1} is consistent with the rotation period measured over much shorter time spans by previous spectroscopic and spectropolarimetric studies, confirming the presence of surface features on this A0 star. The activity signal appears to evolve on long timescales, which may indicate the presence of failed fossil magnetic fields on Vega. TESS data reveal Vega’s photometric rotational modulation for the first time, with a total amplitude of only 10 ppm. A comparison of the spectroscopic and photometric amplitudes suggests that the surface features may be dominated by bright plages rather than dark spots. For the shortest orbital periods, transit and radial-velocity injection recovery tests exclude the presence of transiting planets larger than 2 R {sub ⊕} and most non-transiting giant planets. At long periods, we combine our radial velocities with direct imaging from the literature to produce detection limits for Vegan planets and brown dwarfs out to distances of 15 au. Finally, we detect a candidate radial-velocity signal with a period of 2.43 days and a semi-amplitude of 6 m s{sup −1}. If caused by an orbiting companion, its minimum mass would be ∼20 M {sub ⊕}; because of Vega’s pole-on orientation, this would correspond to a Jovian planet if the orbit is aligned with the stellar spin. We discuss the prospects for confirmation of this candidate planet.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗