Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reflection Interference Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

46 records · Page 3

Generalized analytical and numerical modeling of optical second harmonic generation in anisotropic crystals and complex heterostructures using #SHAARP package

Optical second harmonic generation (SHG) is a nonlinear optical effect widely used for nonlinear optical microscopy and laser frequency conversion. The closed-form analytical solution of the nonlinear optical responses is essential for evaluating the optical responses of new materials whose optical properties are unknown a priori. Many approximations have therefore been employed in the existing analytical approaches, such as slowly varying approximation, weak reflection of the nonlinear polarization, transparent medium, high crystallographic symmetry, Kleinman symmetry, easy crystal orientation along a high-symmetry direction, phase matching conditions and negligible interference among nonlinear waves, which may lead to large errors in the reported material properties. To avoid these approximations, here we have developed an open-source package named Second Harmonic Analysis of Anisotropic Rotational Polarimetry (#SHAARP) for single interface (si) and in multilayers (ml) for homogeneous crystals. The reliability and accuracy are established by experimentally benchmarking with both the SHG polarimetry and Maker fringes predicted from the package using standard materials. SHAARP.si and SHAARP.ml are available through GitHub https://github.com/Rui-Zu/SHAARP and https://github.com/bzw133/SHAARP.ml, respectively.

complex systems↗

Photovoltaic module antireflection coating degradation survey using color microscopy and spectral reflectance

Abstract Commercial antireflective coatings (ARCs) on photovoltaic (PV) module glass can improve module power by 2.5%–3.0%, but their long‐term field performance requires additional study. In this paper, we investigate ARC performance on fielded modules using two nondestructive techniques: reflectance spectroscopy and RGB microscopy, finding a large variation in coating durability and performance. For new coatings, the fleet average nominal power enhancement is 2.8%. This power enhancement is observed to degrade at approximately −0.05%/year absolute over the first 8 years of fielding in arrays that are not regularly cleaned. Interferometry and imaging results imply that coating loss for these modules is due to slow chemical thinning of the initial 125 nm thick coating by 1.4 to 5.0 nm/year. Due to the physics of interference coatings, the performance loss is projected to accelerate as the coating is further thinned, resulting in a coating lifetime (time to 80% of initial performance) of 7.5 to 25 years. At the higher 5.0 nm/year coating loss rates, we estimate that −0.14%/year power degradation of the module can be attributed solely to ARC degradation over the first 20 years. Extreme coating loss is observed on some modules where after 8 years fielding, the coating can be completely removed with a single wet wipe with a lens tissue. A case study is also presented comparing ARC and noncoated modules installed at a single site in 2013. We find that the ARC modules have a 2.6% higher soiling power loss than the noncoated modules; this exceeds the ARC power enhancement of 2.4% and leads to the surprising conclusion that the ARC lowers production for modules in this location due to increased soiling. These results demonstrate that RGB microscopy is a powerful, field‐capable, and quantitative characterization technique for assessing degradation of PV module ARCs.

Karin, Todd↗

Lifetime Stability and Microstructure Properties of Cr/B 4 C X-ray Reflective Multilayer Coatings

Here, this paper demonstrates that highly reflective Cr/B 4 C multilayer interference coatings with nanometric layer thicknesses, designed to operate in the soft X-ray photon energy range, have stable reflective performance for a period of 3 years after deposition. The microstructure and chemical composition of layers and interfaces within Cr/B 4 C multilayers is also examined, with emphasis on the B 4 C-on-Cr interface where a significant diffusion layer is formed and on the oxide in the top B 4 C layer. Lastly, multiple characterization techniques (X-ray reflectivity at different photon energies, X-ray photoelectron spectroscopy, transmission electron microscopy, electron diffraction and X-ray diffraction) are employed and the results reveal a consistent picture of the Cr/B 4 C layer structure.

36 MATERIALS SCIENCE↗

Optical second harmonic generation in anisotropic multilayers with complete multireflection of linear and nonlinear waves using ♯SHAARP.ml package

Abstract Optical second harmonic generation (SHG) is a nonlinear optical effect widely used for nonlinear optical microscopy and laser frequency conversion. Closed-form analytical solution of the nonlinear optical responses is essential for evaluating materials whose optical properties are unknown a priori. A recent open-source code, ♯SHAARP. si , can provide such closed form solutions for crystals with arbitrary symmetries, orientations, and anisotropic properties at a single interface. However, optical components are often in the form of slabs, thin films on substrates, and multilayer heterostructures with multiple reflections of both the fundamental and up to ten different SHG waves at each interface, adding significant complexity. Many approximations have therefore been employed in the existing analytical approaches, such as slowly varying approximation, weak reflection of the nonlinear polarization, transparent medium, high crystallographic symmetry, Kleinman symmetry, easy crystal orientation along a high-symmetry direction, phase matching conditions and negligible interference among nonlinear waves, which may lead to large errors in the reported material properties. To avoid these approximations, we have developed an open-source package named Second Harmonic Analysis of Anisotropic Rotational Polarimetry in Multilayers (♯SHAARP. ml ). The reliability and accuracy are established by experimentally benchmarking with both the SHG polarimetry and Maker fringes using standard and commonly used nonlinear optical materials as well as twisted 2-dimensional heterostructures.

36 MATERIALS SCIENCE↗

Visible photoluminescence and room temperature ferromagnetism in high In-content InGaN:Yb nanorods grown by molecular beam epitaxy

We report the growth of high indium content InGaN:Yb nanorods grown on c-plane sapphire (0001) substrates using plasma assisted molecular beam epitaxy. The in situ reflection high energy electron diffraction patterns recorded during and after the growth revealed crystalline nature of the nanorods. The nanorods were examined using electron microscopy and atomic force microscopy. The photoluminescence studies of the nanorods showed the visible emissions. The In composition was calculated from x-ray diffraction, x-ray photoelectron spectroscopy, and the photoluminescence spectroscopy. The In-concentration was obtained from photoluminescence using modified Vegard's law and found to be around 37% for InGaN and 38% for Yb (5 ± 1%)-doped InGaN with a bowing parameter b = 1.01 eV. The Yb-doped InGaN showed significant enhancement in photoluminescence properties compared to the undoped InGaN. The Yb-doped InGaN nanorods demonstrated the shifting of the photoluminescence band at room temperature, reducing luminescence amplitude temperature dependent fluctuation, and significant narrowing of excitonic emission band as compared to the undoped InGaN. The magnetic properties measured by superconducting quantum interference devices reveals room temperature ferromagnetism, which can be explained by the double exchange mechanism and magnetostriction.

36 MATERIALS SCIENCE↗

Contribution from Ising domains overlapping out-of-plane to perpendicular magnetic anisotropy in Mn 4 N thin films on MgO(001)

Single phase ε-Mn4N thin and ultrathin films are grown on MgO(001) using molecular beam epitaxy. Reflection high-energy electron diffraction and outof-plane x-ray diffraction measurements are taken for each sample in order to determine the in- and out-of-plane strain for each sample. Vibrating sample magnetometry and superconducting quantum interference device measurements, which are performed on the thin and ultrathin films respectively, are used to plot the magnetization of each sample versus both in- and out-of-plane $\vec H$-fields and to determine the magnitude of perpendicular magnetic anisotropy in these films. Three significant components of perpendicular magnetic anisotropy are observed in these films and are attributed to sample strain (1 component) and shape (2 components). Among these components, the most significant component (0.8 to 4.9 $\frac{Merg}{cm^3}$) is identified as a second term of shape anisotropy, which possesses a negative linear relationship with sample thickness over the range from 9 nm to 310 nm. Atomic (magnetic) force microscopy measurements show the presence of a surface localized magnetic polarization (22% to 82%), which increases with decreasing thickness, when the net magnetization of the films is zero. The second term of shape anisotropy as well as the surface localized polarization, which each depend on sample thickness, are each regarded as a consequence of Ising domains overlapping out-of-plane in these films.

Materials Science↗

How Different CETP Inhibitors Effect on CETP Conformation and its Function in CE Transfer among Various Overall Period of Performance

Cholesteryl ester transfer protein (CETP) inhibitors are a new class of therapies for dyslipidemia that simultaneously improve two major cardiovascular disease (CVD) risk factors: elevated LDL-cholesterol and reduced HDL-cholesterol. However, the detailed molecular mechanisms underlying their efficacy are poorly understood, as are any potential mechanistic differences among the drugs in this class. Herein, we employed electron microscopy (EM) to investigate the effects of three of these agents (i.e., Torcetrapib, Dalcetrapib and Anacetrapib) on the CETP structure, CETP-lipoprotein complex formation and CETP-mediated cholesteryl ester (CE) transfer. We found that although none of inhibitors altered the structure of CETP or the conformation of CETP-lipoprotein binary complexes, all inhibitors decreased the binding ratios of HDL-CETP-LDL ternary complexes, especially Torcetrapib and Anacetrapib. The decreased ratios of ternary complexes caused the direct reduction of the CE transfer rates among lipoproteins. However, we also found all inhibitors increased the binding ratios of binary complex, e.g. HDL-CETP and LDL-CETP, which reflect a new mechanism of inhibition: one distal end of CETP bound to a first lipoprotein would trigger a conformational change on the other distal end, resulting in a decreased binding ratio to a second lipoprotein. Therefore, we suggest a new-generation inhibitor that reduces the formation of binary complexes, which may prevent inhibitor interference with the regular lipoprotein metabolism, such as in overly-tight binding of CETP to lipoprotein observed during the treatment of CVD.

59 BASIC BIOLOGICAL SCIENCES↗

The Role of Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology: Proceedings of a Workshop

Quantum concepts hold the potential to enable significant advances in sensing and imaging technologies that could be vital to the study of biological systems. The workshop Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology, held online March 8–10, 2021, was organized to examine the research and development needs to advance biological applications of quantum technology. Hosted by the National Academies of Sciences, Engineering, and Medicine, the event brought together experts working on state-of-the-art, quantum-enabled technologies and scientists who are interested in applying these technologies to biological systems. Through talks, panels, and discussions, the workshop facilitated a better understanding of the current and future biological applications of quantum-enabled technologies in fields such as microbiology, molecular biology, cell biology, plant science, mycology, and many others. The workshop was organized around three main themes. The first, quantum in biology, examined quantum concepts that are hypothesized to be important for life processes and that researchers are working to observe through biological imaging and sensing. The second, quantum for biology, addressed ways to use quantum concepts to enhance technologies for biological imaging and sensing. The third, biology for quantum, offered a wider discussion of how the frontiers of biological imaging and sensing could enable future study using quantum concepts, tools, or technologies. Throughout the workshop, participants identified a wide range of emerging approaches and opportunities at the intersection of quantum physics and biological sensing and imaging. During the workshop, there were some differences in how each speaker defined the term quantum. During one of the panels, Prem Kumar offered thoughts on what phenomena are classical versus quantum, explaining that techniques get progressively more quantum as you move from just having superposition to having superposition with measurement and entanglement. Another explanation from Clarice Aiello delineates the definition into several levels. This includes a base level of “quantum-ness,” which reflects that all matter is made of atoms, and when these particles are isolated they behave based on quantum mechanical principles. A second level is related to quantum coherence, where a single quantum object might be found in a coherent superposition state. A final level, which she described as the quantum-entangled level, involves multiple quantum systems which are entangled among themselves. Overall, the workshop touched on concepts such as superposition, entanglement, and squeezing and their potential implications for communication, computing, and simulation, in addition to the workshop’s main focal area, biological sensing and imaging. At the opening of the workshop, Thorsten Ritz of the University of California, Irvine, identified two questions at the heart of quantum biology: Is the machinery of life quantum mechanical, and can quantum mechanics be used to study the machinery of life in new ways? Participants highlighted systems in which researchers have explored these questions, from the vast array of molecular interactions involved in biological processes such as photosynthesis, to the mechanics involved in cellular functions such as differentiation and aggregation, to the role of oscillating magnetic fields in flight orientation among birds. Sensing and imaging technologies are crucial to biological research; these technologies could both enhance the study of quantum effects and be enhanced by quantum concepts. A critical challenge in biological research is to develop imaging and sensing tools that do not damage or interfere with the often fragile and fleeting systems being studied. Attendees discussed a variety of established and emerging technologies that could enhance noninvasive biological imaging, including single- and two-photon spectroscopy, single-molecule spectroscopy, quantum illumination, ghost imaging, and cryo-electron microscopy. One example came from Marlan Scully who gave a keynote address on the first day of the workshop. Scully emphasized the use of different laser technologies, which exhibit coherence and other quantum properties, in moving toward real-world biological applications, such as the detection of SARS-CoV-2. Both tools and theory will play an important role in advancing quantum biology research and applications. Several participants suggested theorists and experimentalists should work in tandem to understand and model biological processes. While physics often reduces systems to their simplest forms for fundamental insights, participants also noted the value of observing and understanding biological systems in all their “messiness,” capturing both the inner workings of biological systems and the complex interactions that occur within and between organisms. In discussions among participants, several attendees stressed the need to match emerging tools with the right scientific questions. Rather than developing quantum technologies as “a hammer looking for a nail,” participants emphasized a focus on exploring the problems these technologies are best suited to address. For example, it is important to consider the size of the phenomenon being studied, the timescales that are important in answering the scientific question, and other relevant considerations. Every tool along the spectrum from classical to quantum involves its own set of trade-offs. For example, Ted Laurence of the Lawrence Livermore National Laboratory said that quantum measurements, such as single photon counting, fluorescence transitions, and lasers, can take longer to produce the same results as classical measurements. These quantum measurements, however, do not require calibration and can enable new research questions to be answered. Prem Kumar, Northwestern University, noted that, despite their promise, quantum approaches should not be used simply for the sake of using quantum, especially in situations where classical approaches better meet the needs of the researcher. Understanding and applying quantum concepts could enable advances in a wide range of application areas including energy, synthetic biology, medicine, and sustainability. For example, Michelle O’Malley, University of California, Santa Barbara, described how improved noninvasive imaging approaches could help capture the complex interactions and functions involved in the breakdown of organic matter by microbial communities and lead to new technologies for capturing valuable products from plant waste. Several other participants discussed needs in tracking the movement of metabolites and molecules in microbial communities for insights into nutrient cycling in environments such as soil. Margaret Ahmad, Sorbonne University, discussed potential opportunities to leverage the magnetic properties of cryptochromes to advance new treatment approaches for diseases such as COVID-19 and cancer. Looking toward the future development of the field, participants discussed challenges to advancing quantum biology that arise from disciplinary disconnects between physicists and biologists. The siloing of academic research disciplines represents a significant barrier to progress. Disconnects in terminology, motivations and priorities, and structural barriers to collaborative work underscore the need for concerted efforts to bridge these divides. Attendees and speakers offered suggestions for resolving these divergences, establishing a shared language, moving the field forward, and fostering meaningful feedback between disciplines. Overall, participants stressed a need for balance, open communication, collaboration, unity, and clear dialogue on trade-offs between quantum and classical approaches. Keiko Torii, The University of Texas at Austin, said that the best collaborations happen when the project provides mutual advantages that can show off everyone’s talents, each team finds the work interesting, and partners develop a camaraderie to pursue new knowledge. To enable near- and long-term opportunities in this space, participants suggested that exploratory, high-risk funding could improve existing instrumentation to explore quantum enhancement collaboratively. They also emphasized the need for collaboration between quantum physicists and sensing/imaging scientists, which could be advanced through a dedicated quantum biology investigator program. People, even more than technology, will be crucial to the future of quantum biology. Participants explored training, education, and workforce needs to further develop this burgeoning field and cultivate the next generation of scientists. While many programs are still in their nascent stages, participants highlighted examples of approaches and programs being developed at various types of institutions to engage students and professional scientists in quantum biology research. Several participants stressed the need for an inclusive approach, spanning disciplines as well as communities to foster a diverse field fueled by the intellectual contributions of a wide range of people, including historically under-resourced schools and students. To increase awareness and excitement about quantum physics and related areas of biology, attendees suggested capitalizing on the “buzz” around quantum. Several participants emphasized the need to start early, introducing students to quantum concepts and their appealing “weirdness” in K–12 education. Engaging students early—before they become entrenched in traditional disciplinary siloes as typically happens in graduate school—could help to galvanize interest in the area and foster a generation of scientists with the interdisciplinary mindset and skills needed to advance this interdisciplinary field. While these efforts could be advanced at many levels and across multiple sectors, several participants suggested a national quantum biology center could be a valuable hub to coordinate and support quantum biology education and workforce development across academia, industry, and government.

59 BASIC BIOLOGICAL SCIENCES↗

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision Oxygen Isotope Measurements of Two C-Rich Hydrated Interplanetary Dust Particles

Introduction: Chondritic-smooth IDPs (Interplanetary Dust Particles) are low porosity objects whose mineralogy is dominated by aqueous alteration products such as Mg-rich phyllosilicates (smectite and serpentine group) and Mg-Fe carbonate minerals. Their hydrated mineralogy combined with low atmospheric entry velocities have been used to infer an origin largely from asteroidal sources. Spectroscopic studies show that the types and abundance of organic matter in CS IDPs is similar to that in CP IDPs. Although CS IDPs show broad similarities to primitive carbonaceous chondrites, only a few particles have been directly linked to specific meteorite groups such as CM and CI chondrites based on the presence of diagnostic minerals. Many CS IDPs however, have carbon contents that greatly exceed that of known meteorite groups suggesting that they either may derive from comets or represent samples of more primitive parent bodies than do meteorites. It is now recognized that many large, dark primitive asteroids in the outer main belt, as well as some trans-Neptunian objects, show spectroscopic evidence for aqueous alteration products on their surfaces. Some CS IDPs exhibit large bulk D enrichments similar to those observed in the cometary CP IDPs. While hydrated minerals in comets have not been unambiguously identified to date, the presence of the smectite group mineral nontronite has been inferred from infrared spectra obtained from the ejecta from comet 9P/Tempel 1 during the Deep Impact mission. Recent observations of low temperature sulfide minerals in Stardust mission samples suggest that limited aqueous activity occurred on comet Wild-2. All of these observations, taken together, suggest that the high-carbon hydrated IDPs are abundant and important samples of primitive solar system objects not represented in meteorite collections. Oxygen isotopic compositions of chondrites reflect mixing between a 16O-rich reservoir and a 17O,18O-rich reservoir produced via mass-independent fractionation. The composition of the 16O-rich reservoir is well constrained but material representing the 17O,18O-rich end-member is rare. Self-shielding models predict that cometary water, presumed to represent this reservoir, should be enriched in 17O and 18O by greater than 200 per mille. The high-carbon hydrated IDPs may be among the best materials available to search for preserved "cometary" H2O signatures. In order to better understand the origin and evolution of these particles, we have obtained 10 hydrated interplanetary dust particles for coordinated mineralogical, isotopic and organic analyses. We have previously reported the results of mineralogical and O isotopic measurements of two hydrated IDPs; here we present results of O isotopic measurements of three additional IDPs. Samples and Methods: Three interplanetary dust particles (L2079C35, L2083D46 and L2083E46) were embedded in S and partially ultramicrotomed into approximately 70 nanometer sections for analysis via transmission electron microscopy (TEM). The remainders of the unsliced particles were removed from S and pressed into high purity Au foil that was cleaned with HF acid and annealed at 800 degrees Centigrade. The pressed IDPs were analyzed via electron microprobe analysis (EPMA) for quantitative bulk chemical analysis. After EPMA analysis, the IDPs were subjected to precision O isotope analysis with the UCLA Cameca IMS-1270 ion probe. A 20 kiloelectronvolt, 0.5 nanoangstrom Cs+ primary beam of approximately 15 micrometers diameter was used for each measurement. Small particles of San Carlos olivine and Burma spinel were pressed into the Au foil for use as standards to correct for instrumental mass fractionation. The detection system was configured for multicollection, with 16O measured on a Faraday cup, and 17O and 18O measured on electron multipliers (EMs). Individual analyses consisted of 15 cycles of 10 seconds per cycle. Additionally, two microtome thin sections were measured for H isotopic compositions with the JSC NanoSIMS 50L ion probe. An 8 picoangstrom, 16 kiloelectronvolt Cs plus primary beam was used. Measurements consisted of H, C, 12C, 16O, and 18O collected with EMs in multicollection. Terrestrial biotite and kerogen were used for isotopic standards. A significant challenge in O isotope measurement of hydrated minerals is the interference from 16OH at mass 17O. We ensured that the 17O and 16OH peaks were fully resolved by using a mass resolution of greater than 7000 and by careful analyses of San Carlos olivine, Burma spinel and chlorite hydrated mineral standards. The hydride was further suppressed with a cold finger attached to an LN2 dewar to trap volatiles in the sample chamber. All sputtered ions were counted (i.e. presputtering was not used); after applying background, yield and deadtime corrections, we performed a change-point analysis on our data via R in order to determine when the sample reached sputtering equilibrium; data points collected prior to the change point were excluded. Change-point analysis was also used to determine whether the IDP had completely sputtered. Results: Mineralogy. IDPs C35 and E46 exhibited hydrated mineralogies, Fe-Ni sulfide grains, nanoglobules and occasional enstatite grains distributed throughout a fine-grained Mg-Fe saponite matrix. C35 also contained breunnerite (Mg,Fe)CO3; solar flare tracks were observed in enstatite, indicating minimal atmospheric entry heating. The mineralogy of D46 is dominated by a large FeS grain with a minor component of adhering silicate material. D46 was strongly heated during atmorpheric entry as evidenced by a well-developed magnetite rim. EPMA analyses show that both C35 and E46 have high carbon contents of 20 weight percentage (approximately 6X CI). D46 contains approximately 6 wt.weight percentage C. A significant amount of the carbon is present as carbon nanoglobules. Results: Hydrogen isotopes: Although the bulk delta D values of both sections of L2079C35 were within error of SMOW (minus 33 plus or minus 19 per mille, 1 plus or minus 14 per mille 1 sigma), several delta D-rich hotspots were also identified, reaching 2000 per mille. As shown in Fig. 1, these hotspots are clearly associated with discrete carbonaceous inclusions that are akin to nanoglobules found in many meteorites and other IDPs. Oxygen Isotopes. Results of the oxygen isotope measurements are shown in Figure 1. The oxygen isotope composition for L2079C35 was delta 18O equals plus11.6 plus or minus 1.9per mille, delta 17O equals plus 7.9 plus or minus 1.9per mille (2 standard errors). The oxygen isotope composition for L2083D46 was delta 18O equals minus 8.1 plus or minus 1.9 per mille, delta 17O equals minus 6.4 plus or minus 3.1 per mille (2 standard errors). The oxygen isotope composition for L2083E46 was delta 18O equals plus 12.0 plus or minus 1.9 per mille, delta 17O equals plus 9.2 plus or minus 2.0 per mille (2 standard errors). Discussion: Despite mineralogical similarities to highly aqueously altered carbonaceous chondrites, the hydrated IDPs we analyzed have oxygen isotopic compositions that are distinct from matrix materials in the CI, CM, and CR chondrites. The IDPs plot along the Young-Russell line, with delta 17O values for C35 and E46 suggestive of interaction with a 16O-poor reservoir. However, we have thus far not observed evidence of extreme 16O-poor reservoirs expected from self-shielding models and observed in Acfer 094 simplectite. The high carbon contents of the IDPs also set them apart from known meteoritic samples. The lack of atmospheric entry heating effects are consistent with low encounter velocities and suggest either an asteroidal source, or a low inclination, low eccentricity cometary origin. Conclusions: The unusual oxygen isotopic compositions, high carbon contents, and the abundance of Drich nanoglobules, together, suggest that the high-carbon, hydrated IDPs are derived from a primitive source that is not yet represented in meteorite collections.

Snead, C. J.↗