Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resonance techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Temperature Mapping of Stacked Silicon Dies from X-Ray-Diffraction Intensities

Increasing power densities in integrated circuits have led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In three- dimensional (3D) integrated circuits, conventional surface techniques like infrared thermometry are unable to measure the 3D temperature distribution, and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer a high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-ray-diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of individual silicon dies in a stack. Here, utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate, for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 × 400 μm 2 , and a temporal resolution of 20 s. Utilizing a sufficiently high-intensity laboratory source, e.g., from a liquid-anode source, this method can be scaled down to laboratories for noninvasive temperature mapping of 3D integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rigid body mode identification of the PAH-2 helicopter using the eigensystem realization algorithm

The rigid body modes of the PAH-2 'Tiger' helicopter were identified using the Eigensystem Realization Algorithm (ERA). This work complements ground vibration tests performed using DLR's traditional phase resonance technique and the ISSPA (Identification of Structural System Parameters) method. Rigid body modal parameters are important for ground resonance prediction. Time-domain data for ERA were obtained by inverse Fourier transformation of frequency response functions measured with stepped-sine excitation. Mode purity (based on the Phase Resonance Criterion) was generally equal to or greater than corresponding results obtained in the ground vibration tests. All identified natural frequencies and mode shapes correlate well with corresponding ground vibration test results. The modal identification approach discussed in this report has become increasingly attractive in recent years due to the steadily declining cost and increased performance of scientific computers. As illustrated in this application, modern time-domain methods can be successfully applied to data acquired using DLR's existing test equipment. Some suggestions are made for future applications of time domain modal identification in this manner.

Schenk, Axel↗

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.↗

Surface physics and chemistry

Electron paramagnetic resonance techniques for studying surface chemistry and physics pertinent to catalysis

CATALYTIC ACTIVITY↗

Notched graphite polymimide composites at room and notched graphite polymide composites at room and elevated temperatures

The fracture behavior in graphite/polyimide (Gr/PI) Celion 6000/PMR-15 composites was characterized. Emphasis was placed on the correlation between the observed failure modes and the deformation characteristics of center-notched Gr/Pl laminates. Crack tip damage growth, fracture strength and notch sensitivity, and the associated characterization methods were also examined. Special attention was given to nondestructive evaluation of internal damage and damage growth, techniques such as acoustic emission, X-ray radiography, and ultrasonic C-scan. Microstructural studies using scanning electron microscopy, photomicrography, and the pulsed nuclear magnetic resonance technique were employed as well. All experimental procedures and techniques are described and a summary of representative results for Gr/Pl laminates is given.

Awerbuch, J.↗

Collisional Removal of O2 (c(sup 1) Sigma(sup-)(sub u), nu=9) by O2, N2, and He

The collisional removal Of 02 molecules in selected vibrational levels of the c state is studied using a two-laser double-resonance technique. The output of the first laser excites the 02 to nu = 9 or 10 of the c Sigma - state, and the ultraviolet output of the second laser monitors specific rovibrational levels via resonance-enhanced ionization. The temporal evolution of the c Sigma u state vibrational level is observed by scanning the time delay between the two pulsed lasers. As the rate constants for 02 and N2 are similar in magnitude, N2 collisions dominate the removal rate in the earth's atmosphere. For v= 10 colliding with 02, we find a removal rate constant that is 2-5 times that for v=9 and that single quantum collision cascade is an important pathway for removal.

Copeland, Richard A.↗

Fundamental 235 Uranium Nuclear Resonance Spectroscopy (End of Year Report)

Uranium-235 is ubiquitous in the nuclear industry however, detailed characterization by magnetic resonance spectroscopy has remained largely elusive to-date. Conventional nuclear magnetic resonance techniques are ill-suited for characterizing 235 U due to the small gyromagnetic ratio and extremely large quadrupole moment of this spin$^{7}$ /2 isotope. Thus, we have designed and built a high-frequency nuclear quadrupole resonance spectrometer for measuring the quadrupole resonance of this important isotope. A successful nuclear quadrupole resonance measurement of 235 U would be a significant accomplishment and could yield valuable physical parameters such as chemical shifts, local electric field gradients, and through-bond and through-space internuclear couplings, all of which are directly related to local structure. These terms can be used to understand structural details of poorly characterized uranium materials and can improve computational models of uranium for which accurate reference data is lacking

07 ISOTOPE AND RADIATION SOURCES↗

London Penetration Depth Measurements Using Tunnel Diode Resonators

The London penetration depth λ is the basic length scale for electromagnetic behavior in a superconductor. Precise measurements of λ as a function of temperature, field and impurity scattering have been instrumental in revealing the nature of the order parameter and pairing interactions in a variety of superconductors discovered over the past decades. Here we recount our development of the tunnel-diode resonator technique to measure λ as function of temperature and field in small single crystal samples. Furthermore, we discuss the principles and applications of this technique to study unconventional superconductivity in the copper oxides and other materials such as iron-based superconductors. The technique has now been employed by several groups world-wide as a precision measurement tool for the exploration of new superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-frequency microwave resonance measurements from an aircraft - A quantitative estimate of the directional ocean surface spectrum

The use of the two-frequency microwave-resonance technique for airborne measurements of ocean surface-wave spectral components is examined in a summary of experiments conducted with a coherent Ku-band radar flown on a P-3 aircraft in the 1979 MARSEN and 1980 ARSLOE projects. The 1D theoretical formulation used in the analysis of the MARSEN data by Johnson et al. (1982) is extended to the 2D case; the experimental conditions are described in detail; and typical data are presented graphically, analyzed, and compared with independent measurements obtained with a surface-contour radar. The 3.5-deg pencil-beam configuration used in ARSLOE is shown to produce spectra with good directional characteristics (strong resonances at angles of incidence 13-48 deg). It is found that the proper inversion of radar data to surface-elevation spectra requires surface-reflectivity-modulation sources in addition to the long-wave orbital velocity.

Johnson, J. W.↗

Time-Resolved Optical Pump-Resonant X-ray Probe Spectroscopy of 4-Thiouracil: A Simulation Study

We theoretically monitor the photoinduced ππ* → nπ* internal conversion process in 4-thiouracil (4TU), triggered by an optical pump. The element-sensitive spectroscopic signatures are recorded by a resonant X-ray probe tuned to the sulfur, oxygen, or nitrogen K-edge. We employ high-level electronic structure methods optimized for core-excited electronic structure calculation combined with quantum nuclear wavepacket dynamics computed on two relevant nuclear modes, fully accounting for their quantum nature of nuclear motions. We critically discuss the capabilities and limitations of the resonant technique. For sulfur and nitrogen, we document a pre-edge spectral window free from ground-state background and rich with ππ* and nπ* absorption features. The lowest sulfur K-edge shows strong absorption for both ππ* and nπ*. In the lowest nitrogen K-edge window, we resolve a state-specific fingerprint of the ππ* and an approximate timing of the conical intersection via its depletion. A spectral signature of the nπ* transition, not accessible by UV–vis spectroscopy, is identified. The oxygen K-edge is not sensitive to molecular deformations and gives steady transient absorption features without spectral dynamics. Here, the ππ*/nπ* coherence information is masked by more intense contributions from populations. Altogether, element-specific time-resolved resonant X-ray spectroscopy provides a detailed picture of the electronic excited-state dynamics and therefore a sensitive window into the photophysics of thiobases.

97 MATHEMATICS AND COMPUTING↗

Spatially and Temporally Resolved Velocimetry for Hypersonic Flows

The development of new hypersonic flight vehicles is limited by the physical understanding that may be obtained from ground test facilities. This has motivated the present development of a temporally and spatially resolved velocimetry measurement for Sandia National Laboratories (SNL) Hypersonic Wind Tunnel (HWT) using Femtosecond Laser Electronic Excitation Tagging (FLEET). First, a multi-line FLEET technique has been created for the first time and tested in a supersonic jet, allowing simultaneous measurements of velocities along multiple profiles in a flow. Secondly, two different approaches have been demonstrated for generating dotted FLEET lines. One employs a slit mask pattern focused into points to yield a dotted line, allowing for two- or three-component velocity measurements free of contamination between components. The other dotted-line approach is based upon an optical wedge array and yields a grid of points rather than a dotted line. Two successful FLEET measurement campaigns have been conducted in SNL’s HWT. The first effort established optimal diagnostic configurations in the hypersonic environment based on earlier benchtop reproductions, including validation of the use of a 267 nm beam to boost the measurement signal-to-noise ratio (SNR) with minimal risk of perturbing the flow and greater simplicity than a comparable resonant technique at 202 nm. The same FLEET system subsequently was reconstituted to demonstrate the ability to make velocimetry measurements of hypersonic turbulence in a realistic flow field. Mean velocity profiles and turbulence intensity profiles of the shear layer in the wake of a hypersonic cone model were measured at several different downstream stations, proving the viability of FLEET as a hypersonic diagnostic.

33 ADVANCED PROPULSION SYSTEMS↗

Microwave Meissner screening properties of proximity-coupled topological-insulator / superconductor bilayers

The proximity-coupled topological-insulator / superconductor (TI/SC) bilayer system is a representative system to realize topological superconductivity. In order to better understand this unique state and enable future applications of the TI/SC bilayer, a comprehensive characterization and understanding of the microscopic properties of the bilayer are required. In this work, a microwave Meissner screening study, which exploits a high-precision microwave resonator technique, is conducted on the SmB 6 /YB 6 thin-film bilayers as an example TI/SC system. The study reveals spatially dependent electrodynamic screening response of the TI/SC system that is not accessible to other techniques, from which the corresponding microscopic properties of a TI/SC bilayer can be obtained. The TI thickness dependence of the effective penetration depth suggests the existence of a bulk insulating region in the TI layer. The spatially dependent electrodynamic screening model analysis provides an estimate for the characteristic lengths of the TI/SC bilayer: normal penetration depth, normal coherence length, and the thickness of the surface states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selecting the Optimal Fluorinated Ether Co-Solvent for Lithium Metal Batteries

To guide the selection of a suitable fluorinated ether (FE) co -solvent for lithium metal batteries, it is crucial to understand the relationship between the organic structures of the FEs and the electrochemical performance of an FE-containing electrolyte. In this work, 1,1,2,2-tetrafluoro-1-(2,2,2-trifluoroethoxy)ethane (FEE), 1,1,2,2-tetrafluoro-3-(1,1,2,2-tetrafluoroethoxy)-propane (TTE), and 1,2-bis(1,1,2,2-tetrafluoroethoxy)ethane (OFDEE) were chosen as representative FE co-solvents because of their distinct structural properties. The structure-activity relationship between the FEs and the electrochemical performance of Li||LiNi 0.6 Mn 0.2 Co 0.2 O 2 (Li||NMC622) cells was correlated and quantified by Fourier-transform infrared and multi-dimensional nuclear magnetic resonance techniques. Sand's model was also employed to assess the extent of lithium dendrite formation in the cells using various FE electrolytes. The cycling performance of Li||NMC622 cells using different FE co-solvents follows the order FEE > TTE > OFDEE. Further, since the direct measurement of Sand's time is difficult, we introduced relative Sand's time to probe the diffusion behavior of each electrolyte, and the results showed that the best performance was obtained in the electrolyte with the longest relative Sand's time. Moreover, the lithium metal cell using the electrolyte with FEE co-solvent showed similar capacity retention compared with the baseline electrolyte at room temperature, but it demonstrated significantly improved low-temperature performance. The results indicate that FEE is a promising co-solvent candidate for improving the low-temperature performance of lithium metal batteries because it possesses not only non-solvating behavior but also very low viscosity and non-flammability. The advanced electrolyte LiPF 6 -FEC-DMC-FEE enables very stable cycling of lithium metal batteries at various temperatures.

25 ENERGY STORAGE↗