The retinal threshold gradient in the presence of a high-luminance target and in total darkness
Mean retinal threshold gradient along horizontal meridian for dark and light adapted eyes, considering dynamic neural mechanism
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Mean retinal threshold gradient along horizontal meridian for dark and light adapted eyes, considering dynamic neural mechanism
Experiments were undertaken to elucidate the stimulus luminance-retinal area relationship that underlies response time (RT) behavior. Mean RT was significantly faster to stimuli imaged beyond about 70 deg of arc from the fovea when their luminance was increased by an amount equal to the foveal stimulus luminance multiplied by the cosine of the angle between the peripheral stimuli and the line of sight. This and additional data are discussed in relation to previous psychophysical data and to possible response mechanisms.
Principles of thermodynamics are applied to the study of the ultramicroscopic anatomy of the inner eye. Concepts introduced and discussed include: the retina as a three-dimensional sensor, light signals as coherent beams in relation to the dimensions of retinal pigments, pigment effects topographed by the conjugated antennas effect, visualizing lights, the autotropic function of hemoglobin and some cytochromes, and reversible structural arrangements during photopic adaptation. A paleoecological diagram is presented which traces the evolution of scotopic vision (primitive system) to photopic vision (secondary system) through the emergence of structures sensitive to the intensity, temperature, and wavelengths of the visible range.
It has been asserted that the pitch orientation of a visual array and of an observer's body jointly determine the perception of GREL. The current study formally tests this assertion over an extended range with multiple combinations of visual and body pitch orientations. Ten subjects were individually secured in a Circolectric bed surrounded by a room (pitchroom) with walls that could be pitched at various angles with respect to gravity. The bed and the walls of the room were independently adjusted to each of five positions relative to gravitational vertical: -15, -7.5, 0, +7.5, and +15 degrees, yielding 25 combinations of body x room pitch angles, and retinal image pitch (RIP) conditions ranging from -30 to +30 degrees. Each subject set a target to apparent GREL while viewing it against a background of two electroluminescent strips on the outer edges of the far wall of the room. As determined by ANOVA, the orientation of the room, and its interaction with that of the observer, significantly altered GREL (p less than 0.01). Regression analysis showed that GREL was best described as a linear summation of the weighted independent contributions from a body-referenced mechanism (B) and a visual mechanism given by the orientation of the background array on the retina (RIP). The equation for this relationship is: GREL = .74 (B) +.64 (RIP) - 1.42; r-squared = .994.
We studied short-term (30 min) adaptation of the vestibulo-ocular reflex (VOR) in five normal humans using a "position error" stimulus without retinal image motion. Both before and after adaptation a velocity gain (peak slow-phase eye velocity/peak head velocity) and a position gain (total eye movement during chair rotation/amplitude of chair motion) were measured in darkness using search coils. The vestibular stimulus was a brief ( approximately 700 ms), 15 degrees chair rotation in darkness (peak velocity 43 degrees /s). To elicit adaptation, a straight-ahead fixation target disappeared during chair movement and when the chair stopped the target reappeared at a new location in front of the subject for gain-decrease (x0) adaptation, or 10 degrees opposite to chair motion for gain-increase (x1.67) adaptation. This position-error stimulus was effective at inducing VOR adaptation, though for gain-increase adaptation the primary strategy was to substitute augmenting saccades during rotation while for gain-decrease adaptation both corrective saccades and a decrease in slow-phase velocity occurred. Finally, the presence of the position-error signal alone, at the end of head rotation, without any attempt to fix upon it, was not sufficient to induce adaptation. Adaptation did occur, however, if the subject did make a saccade to the target after head rotation, or even if the subject paid attention to the new location of the target without actually looking at it.
Motion sickness in the general population is a significant problem driven by the increasingly more sophisticated modes of transportation, visual displays, and virtual reality environments. It is important to investigate non-pharmacological alternatives for the prevention of motion sickness for individuals who cannot tolerate the available anti-motion sickness drugs, or who are precluded from medication because of different operational environments. Based on the initial work of Melvill Jones, in which post hoc results indicated that motion sickness symptoms were prevented during visual reversal testing when stroboscopic vision was used to prevent retinal slip, we have evaluated stroboscopic vision as a method of preventing motion sickness in a number of different environments. Specifically, we have undertaken a five part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness while: (1) using visual field reversal, (2) reading while riding in a car (with or without external vision present), (3) making large pitch head movements during parabolic flight, (4) during exposure to rough seas in a small boat, and (5) seated and reading in the cabin area of a UH60 Black Hawk Helicopter during 20 min of provocative flight patterns.
Significant risks for visual impairment associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions [1]. We hypothesize that microgravity-induced fluid shifts result in pathological changes within blood vessels of the retina that precede development of visual and other ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated for two studies in 30deg infrared (IR) Heidelberg Spectralis(Registered Trademark) images with NASA's innovative VESsel GENeration Analysis (VESGEN) software [2,3]. The retrospective studies include: (1) before, during and after (pre, mid and post) 6º head-down tilt (HDT) in human subjects during 70 days of bed rest, and (2) before and after missions to the International Space Station (ISS) by U.S. crew members. Results for both studies are almost complete. A preliminary example for HDT is described below.
PURPOSE: We investigated whether retinis pigmentosa (RP) patients with residual visual field of < 100 degrees could perceive heading from optic flow. METHODS: Four RP patients and four age-matched normally sighted control subjects viewed displays simulating an observer walking over a ground. In experiment 1, subjects viewed either the entire display with free fixation (full-field condition) or through an aperture with a fixation point at the center (aperture condition). In experiment 2, patients viewed displays of different durations. RESULTS: RP patients' performance was comparable to that of the age-matched control subjects: heading judgment was better in the full-field condition than in the aperture condition. Increasing display duration from 0.5 s to 1 s improved patients' heading performance, but giving them more time (3 s) to gather more visual information did not consistently further improve their performance. CONCLUSIONS: RP patients use active scanning eye movements to compensate for their visual field loss in heading perception; they might be able to gather sufficient optic flow information for heading perception in about 1 s.
Dehydrogenases activities in rabbit retina homogenates exposed to oxygen at high partial pressure for various time periods
When a wide field is sinusoidally modulated both in space and in time, the spatial frequency of the pattern will appear doubled at high rates of modulation. Kelly (1966) proposed that this illusion is due to temporal integration of the nonlinear brightness response of the visual system. The anatomical locus of this temporal integrator is uncertain, and could be subcortical. Results indicate that spatial frequency doubling follows binocular disparity detection and is thus a cortical phenomenon.
Investigation confirmed that GRR images can be consistently obtained and that these images contain information required to detect the optical inequality of one eye compared to the fellow eye. Digital analyses, electro-optical analyses, and trained observers were used to evaluate the GRR images. Two and three dimensional plots were made from the digital analyses results. These plotted data greatly enhanced the GRR image content, and it was possible for nontrained observers to correctly identify normal vs abnormal ocular status by viewing the plots. Based upon the criteria of detecting equality or inequality of ocular status of a person's eyes, the trained observer correctly identified the ocular status of 90% of the 232 persons who participated in this program.
A remote television viewing system employing an eye tracker is disclosed, wherein a small region of the image appears in high resolution, and the remainder of the image appears in low resolution. The eye tracker monitors the position of the viewer's line of sight. The eye tracker position data is transmitted to the remote television camera and control. Both the remote camera and television display are adapted to have selectable high-resolution and low resolution raster scan modes. The position data from the eye tracker is used to determine the point at which the high-resolution scan is to commence. The video data defining the observed image is encoded in a novel format, wherein in each data field, the data representing the position of the high resolution region of predetermined size appears first, followed by the high resolution zone video data and then the low-resolution region data. As the viewer's line of sight relative to the displayed image changes, the position of the high resolution region changes to track the viewer's line of sight.
Lightweight, inexpensive electronic and photographic instrument developed for detection, monitoring, and objective quantification of ocular/systemic disease or physiological alterations of retina, blood vessels, or other structures in anterior and posterior chambers of eye. Operated with little training. Functions with human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in hospital, laboratory, field, or other environment. Produces video images viewed directly and/or digitized for simultaneous or subsequent analysis. Also equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images of skin, nose, ear, throat, or mouth to detect lesions or diseases.
A method for tracking an object in a sequence of images is described. Such sequence of images may, for example, be a sequence of television frames. The object in the current frame is correlated with the object in the previous frame to obtain the relative location of the object in the two frames. An optical joint transform correlator apparatus is provided to carry out the process. Such joint transform correlator apparatus forms the basis for laser eye surgical apparatus where an image of the fundus of an eyeball is stabilized and forms the basis for the correlator apparatus to track the position of the eyeball caused by involuntary movement. With knowledge of the eyeball position, a surgical laser can be precisely pointed toward a position on the retina.
Losses of photoreceptor cells (rods) from the retinas of New Zealand white (NZW) rabbits were detectable within 2 years after localized acute irradiation of optic and proximal tissues with greater than or equal to 7 Gy of 530 MeV u(exp -1) Ar-40 ions or greater than or equal to 2 Gy of 465 MeV u(exp -1) Fe-56 ions in the Bragg plateau region of energy deposition. Those limits were determined only from an analysis of variance of dose groups because the shapes of the dose response curves at early post-irradiation times are not known, a concern being addressed by experiments in progress. Losses of photoreceptor cells for the period 0.5-2.5 years post-irradiation, determined by provisional linear regression analysis, were approxiamtely 1.7% Gy(exp -1) and 2.5% Gy(exp.-1) for Ar-40 and Fe-56 ions, respectively.
A lightweight, relatively inexpensive electronic and photographic instrument has been re-developed for the detection, monitoring, and objective quantification of ocular/ systemic disease or physiological alterations of the retina, blood vessels, or other structures in the anterior and posterior chambers of the eye. The instrument can be operated with little training. It can function with a human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in a hospital, laboratory, field, or other environment. The instrument produces video images that can be viewed directly and/or digitized for simultaneous or subsequent analysis. It can also be equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images ot the skin, nose, ear, throat, or mouth to detect lesions or diseases.
No abstract available
Losses of photoreceptor cells (rods) from the retinas of New Zealand white (NZW) rabbits were detectable within 2 years after localized acute irradiation of optic and proximal tissues with > or = 7 Gy of 530 MeV u-1 40Ar ions or > or = 2 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition. Those limits were determined only from an analysis of variance of dose groups because the shapes of the dose response curves at early post-irradiation times are not known, a concern being addressed by experiments in progress. Losses of photoreceptor cells for the period 0.5-2.5 years post-irradiation, determined by provisional linear regression analysis, were approximately 1.7% Gy-1 and 2.5% Gy-1 for 40Ar and 56Fe ions, respectively.