Search NASA⌕ Search

SEARCH · Search NASA

Results for “Return Air Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Aeroheating Testing of the Mars Sample Return Earth Entry System with Surface Roughness

The Mars Sample Return Earth Entry System is a mission concept which would be the first NASA entry vehicle to utilize a woven thermal protection system as well as a 52.5 degree sphere-cone forebody geometry. Due to its novel design, historic experimental data sets were insufficient to validate the models used to characterize the expected aerothermal environment. A wind tunnel test campaign was funded by the Mars Sample Return Earth Entry System project in the NASA Langley 20-Inch Mach 6 Air Tunnel in order to obtain validation data. The December 2023 test entry of this campaign sought to obtain thermographic data to capture the impact of supersonic flow near woven surface roughness elements on convective heating augmentation, which was the largest remaining uncertainty in aerothermal design of the Earth Entry System. Data obtained were in family with prior results obtained on identical woven patterns without supersonic flow present at roughness elements, and it was found that this presence of supersonic flow did not have a noticeable effect on surface convective heating augmentation. Data were directly leveraged to support the NASA Mars Sample Return flight program and this data set is valuable for validating computational solutions on roughness-resolved grids.

Mars Sample Return↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-compartment Aerosol Transport Model

A simple aerosol transport model was developed for a multi-compartmented cleanroom. Each compartment was treated as a well-mixed volume with ventilating supply and return air. Gravitational settling, intercompartment transport, and leakage of exterior air into the system were included in the model. A set of first order, coupled, ordinary differential equations was derived from the conservation equations of aerosol mass and air mass. The system of ODEs was then solved in MATLAB using pre-existing numerical methods. The model was verified against cases of (1) constant inlet-duct concentration, and (2) exponentially decaying inlet-duct concentration. Numerical methods resulted in normalized error of less than 10 -9 when model solutions were compared to analytical solutions. The model was validated against experimental measurements from a single field test and showed good agreement in the shape and magnitude of the aerosol concentration profile with time.

54 ENVIRONMENTAL SCIENCES↗

On the analysis of clear air radar echoes severely contaminated by clutter

Many radar systems work in environments where clutter return overwhelm the atmospheric echoes. Sometimes by as much as 50 dB. At the Arecibo Observatory (AO), for example, clutter levels are conspicuously high. This situation greatly reduces its usefulness for lower atmospheric studies. It is not possible in general, to observe height profiles of the vertical component of the wind velocity. This parameter is important to understand planetary scale circulation, mountain and lee waves, turbulence, troprospheric and stratorspheric interactions and vertical transport of horizontal momentum. The topics discussed include the following: clutter propagation characteristics, knowledge-based spectral analysis system, and signal analysis system.

Ierkic, H. Mario↗

Do-It-Yourself Additives Recharge Auto Air Conditioning

In planning for a return mission to the Moon, NASA aimed to improve the thermal control systems that keep astronauts comfortable and cool while inside a spacecraft. Goddard Space Flight Center awarded a Small Business Innovation Research (SBIR) contract to Mainstream Engineering Corporation, of Rockledge, Florida, to develop a chemical/mechanical heat pump. IDQ Inc., of Garland, Texas, exclusively licensed the technology and incorporates it into its line of Arctic Freeze products for automotive air conditioning applications. While working on the design, Mainstream Engineering came up with a unique liquid additive called QwikBoost to enhance the performance of the advanced heat pump design.

Source record↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic control study of the icing research tunnel refrigeration system

The Icing Research Tunnel (IRT) at the NASA Lewis Research Center is a subsonic, closed-return atmospheric tunnel. The tunnel includes a heat exchanger and a refrigeration plant to achieve the desired air temperature and a spray system to generate the type of icing conditions that would be encountered by aircraft. At the present time, the tunnel air temperature is controlled by manual adjustment of freon refrigerant flow control valves. An upgrade of this facility calls for these control valves to be adjusted by an automatic controller. The digital computer simulation of the IRT refrigeration plant and the automatic controller that was used in the simulation are discussed.

Kieffer, Arthur W.↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Water vapor recovery from plant growth chambers

NASA is investigating the use of plant growth chambers (PGCs) for space missions and for bases on the moon and Mars. Key to successful development of PGCs is a system to recover and reuse the water vapor that is transpired from the leaves of the plants. A design is presented for a simple, reliable, membrane-based system that allows the recovery, purification, and reuse of the transpired water vapor through control of temperature and humidity levels in PGCs. The system is based on two membrane technologies: (1) dehumidification membrane modules to remove water vapor from the air, and (2) membrane contactors to return water vapor to the PGC (and, in doing so, to control the humidity and temperature within the PGC). The membrane-based system promises to provide an ideal, stable growth environment for a variety of plants, through a design that minimizes energy usage, volume, and mass, while maximizing simplicity and reliability.

Ray, R. J.↗

A Plug-and-Play Duct System Evaluation

This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Plug-and-Play Duct System Evaluation

This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-incomehomes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach for Practical Grid-Resolved Roughness Aerothermodynamic Simulations for Woven Heatshield Surfaces

An approach for simulating the aerothermal environment over a patterned roughness surface within an otherwise axisymmetric flow is developed. The patterned roughness is simplified into a sinusoidal shape that captures the basic features of a charred 3MDCP ablator. Two orientations of this pattern, which are equally flight relevant due to the forming process, enable periodic boundary conditions along the edges of a grid spanning a single roughness element. This simplified three-dimensional grid represents the minimum problem size for a patterned roughness simulation, which enables computationally efficient grid-resolved roughness simulations. This approach is validated by simulating the Langley Mach 6 measurements made on a similar sinusoidal surface, which results in convective heating within 5% of the experimental data. Applying this approach to Mars Sample Return (MSR) Earth Entry System (EES) flight cases, considering simulations with both 11 species air and 30 species air with ablation products, results in heating augmentation that is slightly lower than the widely-used Dahm correlation approach, with the difference being dependent on pattern orientation. This result provides the only insight into the behavior of the roughness augmentation at the high temperature reacting flow conditions present for EES flight cases, which are not captured by available ground test measurements. For shear augmentation, the simulations revealed that the surface-parallel pressure component is dominant. For arc-jet tests targeted to flight values for shear, the higher arc-jet pressures required to match flight values for shear result in up to a 400% increase in the rough wall shear value, which is not captured by the Dahm correlation. This indicates that, to avoid significant over-testing, grid-resolved roughness simulations are required to determine arc-jet conditions that produce flight shear levels in rough-wall scenarios.

Christopher O Johnston↗

Biosatellite II mission

Biosatellite B was launched from Cape Kennedy, Florida, on a two-stage DELTA launch vehicle at 6:04 p.m. on 7 September, 1967. Approximately nine minutes later the 435 kg spacecraft biological laboratory was placed into a satisfactory 315 km near-circular earth orbit, successfully separated from the launch vehicle's second stage and was designated Biosatellite II. The scientific payload consisting of thirteen selected general biology and radiation experiments were subjected to planned, carefully controlled environmental conditions during 45 hours of earth-orbital flight. The decision was made to abbreviate the scheduled 3-day mission by approximately one day because of a threatening tropical storm in the recovery area, and a problem of communication with the spacecraft from the tracking stations. Highest priority was placed on recovery which was essential to obtain the scientific results on all the experiments. The operational phase of the mission came to a successful conclusion with the deorbit of the recovery capsule, deployment of the parachute system and air recovery by the United States Air Force. The 127 kg recovery capsule was returned to biology laboratories at Hickam Air Force Base, Hawaii, for disassembly and immediate inspection and analysis of the biological materials by the experimenters. It was evident immediately that the quality of the biology was excellent and this fact gave promise of a high return of scientific data. The environmental conditions provided to the experimental material in the spacecraft, provisions for experimental controls, and operational considerations are presented as they relate to interpretation of the experimental results.

Biosatellite 2 Project↗

New Platform Provides Innovation

Sky Bridge is the primary unclassified scientific computing platform at Sandia, serving all Mission Areas within the Laboratories. At the formal ribbon cutting in December 2014, Laboratories Director Paul Hommert emphasized the importance of the Institutional Computing Program in providing a critical core Laboratories capability. The deployment of Sky Bridge more than doubled the computing cycles available in Sandia’s restricted computing environment, while incorporating the same underlying architecture as the existing ASC/TLCC2 compute clusters, thus allowing many existing computer codes to run on the system without any major modifications. Sky Bridge immediately addressed the shortfall in projected computing cycles for Sandia’s programs of energy and environment, nuclear weapons life expectancy program (NW LEP), and Applied Laboratory Technology (ALT). From a technological perspective, Sky Bridge is contributing to the readiness of the data center facility and operations personnel for a transition to liquid cooling in future HPC systems and other high-density systems. By comparing the performance and energy costs of Sky Bridge to similar systems (e.g., Dark Bridge) that are air-cooled rather than liquid-cooled, it will also provide valuable data for making return on investment decisions for future purchases. Installation of Sky Bridge enables decommissioning of the Red Sky supercomputer, reduce energy and support costs, and make room for future HPC systems already planned through the ASC and Institutional Computing programs. Sky Bridge’s use of liquid cooling (cold plate to the systems processors) and more efficient power distribution (480 V direct to the rack) saved over $\$$700, 000 in construction costs while reducing annual operating costs by $\$$120,000.

97 MATHEMATICS AND COMPUTING↗

A system for measuring methane fluxes from inland and coastal wetland environments

A CH4 measuring system with a sensitivity of 0.01 ppmv and a response time of 1 sec is described. Pulses are separable from moving and stationary readings, the device floats, and air velocity in the chamber can be controlled in the range 0-4.4 m/sec. The system is set on the water so that controlled speed air from beneath can enter an inner chamber and be pumped through a gas filter correlation system (GFC) before being returned to the chamber. The GFC mechanism yields an absorption signal in the form of a dc voltage, which a processor orders printed on a strip chart as a function of time. Detection of the CH4 amounts is through IR absorption, and the sensitivity of the instrument has been measured at .002-.051 g/sq m per day with air flows in the range 0.90-4.40 m/sec. The unit can be modified to detect CO and CO2, and further applications for low plant canopies and land surfaces are indicated.

Sebacher, D. I.↗