Search NASA⌕ Search

SEARCH · Search NASA

Results for “Robustness analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

SU-E-T-621: Analysis of Robustness of Proton Pencil Beam Scanning Technique for Delivery of Craniospinal Irradiation

Purpose: To investigate the robustness and safety of craniospinal irradiation (CSI) planned with a proton pencil beam scanning (PBS) technique which overcomes the complexity of the planning associated with feathering match lines. Methods: Six CSI patients were planned with gradient-dose matching using PBS technique. Uniform dose coverage to the entire target volumes was achieved with averaged junction lengths of 6.9±0.3 cm. Robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in longitudinal direction and compared with the original non-shifted plan with metrics of conformity number (CN) and homogeneity index (HI). An anthropomorphic phantom study using film measurements was also carried out on a plan with 5 cm junction length. Results: For a given junction length, the dose errors were directly proportional to the setup errors. Setup errors of 3 mm from each field caused on average 3.5% lower CN and 2.1% higher HI. Minimal D95% to PTV and D98% to CTV were reduced by 2.2%±1.5% and 2.8%±1.7% respectively. A drop of maximal 6.8%±5.5% on the minimal dose to the cribriform plate was also observed. When the junction length was 5cm or longer, these 3mm setup errors from each field resulted in up to 12% dose errors. Consistent results were reached between film measurements and planned dose profiles in the junction area. Due to near-zero exit doses beyond the target volume, sparing of anterior organs such as heart, liver, lung and kidney were observed. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the CSI treatment with matched proton fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust and safe to longitudinal setup errors compared to conventional feathering methods.

60 APPLIED LIFE SCIENCES↗

Improving Access to Foundational Energy Performance Data

Access to foundational energy performance data is key to improving the efficiency of the built environment. However, stakeholders often lack access to what they perceive as credible energy performance data. Therefore, even if a stakeholder determines that a product would increase efficiency, they often have difficulty convincing their management to move forward. Even when credible data do exist, such data are not always sufficient to support detailed energy performance analyses, or the development of robust business cases. One reason for this is that the data parameters that are provided are generally based on the respective industry norms. Thus, for mature industries with extensive testing standards, the data made available are often quite detailed. But for emerging technologies, or for industries with less well-developed testing standards, available data are generally insufficient to support robust analysis. However, even for mature technologies, there is no guarantee that the data being supplied are the same data needed to accurately evaluate a product?s energy performance. To address these challenges, the U.S. Department of Energy funded development of a free, publically accessible Web-based portal, the Technology Performance Exchange(TM), to facilitate the transparent identification, storage, and sharing of foundational energy performance data. The Technology Performance Exchange identifies the intrinsic, technology-specific parameters necessary for a user to perform a credible energy analysis and includes a robust database to store these data. End users can leverage stored data to evaluate the site-specific performance of various technologies, support financial analyses with greater confidence, and make better informed procurement decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The dissolution behavior of borosilicate glasses in far-from equilibrium conditions

In far-from-equilibrium conditions, the dissolution of borosilicate glasses used to immobilize nuclear waste is known to be a function of both temperature and pH. The aim of this paper is to study effects of these variables on three model waste glasses (SON68, ISG, AFCI). To do this, experiments were conducted at temperatures of 23, 40, 70, and 90 °C and pH(RT) values of 9, 10, 11, and 12 with the single-pass flow-through (SPFT) test method. The results from these tests were then used to parameterize a kinetic rate model based on transition state theory. Both the absolute dissolution rates and the rate model parameters are compared with previous results. Discrepancies in the absolute dissolution rates as compared to those obtained using other test methods are discussed. Rate model parameters for the three glasses studied here are nearly equivalent within error and in relative agreement with previous studies. The results were analyzed with a linear multivariate regression (LMR) and a nonlinear multivariate regression performed with the use of the Glass Corrosion Modeling Tool (GCMT), which is capable of providing a robust uncertainty analysis. This robust analysis highlights the high degree of correlation of various parameters in the kinetic rate model. As more data are obtained on borosilicate glasses with varying compositions, the effect of glass composition on the rate parameter values could possibly be obtained. This would allow for the possibility of predicting the forward dissolution rate of glass based solely on composition

Neeway, James J.↗

Electrical Energy Storage Data Submission Guidelines

Energy storage technologies are positioned to play a substantial role in power delivery systems. They are being touted as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, due to their relative infancy, there is a lack of knowledge on how these resources truly operate over time. Data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verifying the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data the provider supplies for analysis. After review of energy storage data received from several providers, it has become clear that some of these data are inconsistent and incomplete, raising the question of their efficacy for robust analysis. This report reviews and proposes general guidelines such as sampling rates and data points that providers must supply for robust data analysis to take place. Consistent guidelines are the basis of the proper protocol and ensuing standards to (a) reduce the time it takes data to reach those who are providing analysis; (b) allow them to better understand the energy storage installations; and (c) enable them to provide high-quality analysis of the installations. This report is intended to serve as a starting point for what data points should be provided when monitoring. As battery technologies continue to advance and the industry expands, this report will be updated to remain current.

25 ENERGY STORAGE↗

Electrical Energy Storage Data Submission Guidelines, Version 2

Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.

25 ENERGY STORAGE↗

e RPCA : Robust Principal Component Analysis for Exponential Family Distributions

Abstract Robust principal component analysis (RPCA) is a widely used method for recovering low‐rank structure from data matrices corrupted by significant and sparse outliers. These corruptions may arise from occlusions, malicious tampering, or other causes for anomalies, and the joint identification of such corruptions with low‐rank background is critical for process monitoring and diagnosis. However, existing RPCA methods and their extensions largely do not account for the underlying probabilistic distribution for the data matrices, which in many applications are known and can be highly non‐Gaussian. We thus propose a new method called RPCA for exponential family distributions (), which can perform the desired decomposition into low‐rank and sparse matrices when such a distribution falls within the exponential family. We present a novel alternating direction method of multiplier optimization algorithm for efficient decomposition, under either its natural or canonical parametrization. The effectiveness of is then demonstrated in two applications: the first for steel sheet defect detection and the second for crime activity monitoring in the Atlanta metropolitan area.

Zheng, Xiaojun↗

Global Value Chain and Manufacturing Analysis on Geothermal Power Plant Turbines

In this study, we have undertaken a robust analysis of the global supply chain and manufacturing costs for components of Organic Rankine Cycle (ORC) Turboexpander and steam turbines used in geothermal power plants. We collected a range of market data influencing manufacturing from various data sources and determined the main international manufacturers in the industry. The data includes the manufacturing cost model to identify requirements for equipment, facilities, raw materials, and labor. We analyzed three different cases; 1) 1 MW geothermal ORC Turboexpander 2) 5 MW ORC Turboexpander 3) 20 MW geothermal Steam Turbine

15 GEOTHERMAL ENERGY↗

Requirements and Recommendations for a Physical Attack Characterization Framework

This study seeks to identify existing frameworks or develop requirements and recommendations for a new framework that can consistently characterize physical attacks, analogous to MITRE ATT&CK®. MITRE ATT&CK is widely used across government, research organizations, and the cyber security community to characterize cyber attack tactics, techniques, and procedures (TTPs) in a consistent and commonly understood manner. While physical attack taxonomies, methodologies, and other tools for evaluating physical security do exist, many are sector and/or facility-type specific—and therefore not able to provide comparable scenarios across sectors—or are more focused on security assessment instead of the characterization of attacks themselves. A MITRE ATT&CK analog for physical attacks on critical infrastructure would provide a common language and structure for analysis of physical attacks. Existing attack characterization methodologies do not robustly address cyber-physical security risks. To fully understand a facility’s security needs, it is important to understand the entire vulnerability landscape from both a physical and a cyber perspective. To underscore this need, organizations such as the Cybersecurity and Infrastructure Security Agency (CISA) are calling for a coordinated approach to cyber and physical security, which they refer to as cyber and physical security convergence. A physical attack characterization framework that could be used jointly with MITRE ATT&CK would help support a more robust analysis in support of convergence, enabling the consistent characterization of attacks that utilize both cyber and physical tactics and techniques. This could provide analysts and stakeholders with a clearer understanding of how security mitigations deployed in the physical realm impact security risks in the cyber realm, and vice versa. In this study, the project team evaluates existing physical security taxonomies and methodologies to assess whether an existing method can be used to create a “physical half” of MITRE ATT&CK. This study then provides requirements and recommendations for a framework that can leverage aspects of existing methodologies. The goal of the final framework is for it to be widely adopted and referenced, regardless of critical infrastructure sector, facility type, or facility components. This study also identifies applicable use cases for when and how a framework could be applied across the various critical infrastructure sectors for a variety of attack types or motivations. Through a literature review of existing security-focused methodologies and taxonomies, engagement with relative stakeholders, evaluation of potential physical attack framework use cases, and subsequent identification of requirements, this study identified the following key findings and recommendations: There is a need for a new physical attack characterization framework; A physical attack framework should be interoperable with the MITRE ATT&CK framework; A physical attack framework should be broadly applicable, but with detailed tactics, techniques, and procedures that encompass the entire attack path; A physical attack framework should be based on observed or feasible events; A physical attack framework should adapt features from existing methodologies, frameworks, and taxonomies; A physical attack framework should be owned, overseen, and maintained by one organization.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SIRHEN : a data reduction program for photonic Doppler velocimetry measurements.

SIRHEN (Sandia InfraRed HEtrodyne aNalysis) is a program for reducing data from photonic Doppler velocimetry (PDV) measurements. SIRHEN uses the short-time Fourier transform method to extract velocity information. The program can be run in MATLAB (2008b or later) or as a Windows executable. This report describes the new Sandia InfraRed HEtrodyne aNalysis program (SIRHEN; pronounced 'siren') that has been developed for efficient and robust analysis of PDV data. The program was designed for easy use within Sandia's dynamic compression community.

99 GENERAL AND MISCELLANEOUS↗