Search NASA⌕ Search

SEARCH · Search NASA

Results for “Root cause analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strain energy-based fatigue failure analyses of LB-PBF Inconel 718: Effect of build orientation

Additively manufactured Inconel 718 parts fabricated in three build orientations (horizontal, vertical, and angled at 45 degrees) are tested in fully-reversed bending fatigue mode. Damping measurements via the Impulse Excitation technique are used to assess the defects content in the microstructure and fractography analysis is performed to detect the root cause of failure. Two micro- and macro-scale methodologies of fatigue damage estimation based on the dissipated heat per cycle and the statistical estimation of micro-plastic strain energies are used to assess fatigue damage. It is shown that at a given stress level, the vertically built specimens endure the most fatigue damage before failure while the diagonally built ones sustain the least. As a result, the fatigue life is estimated for arbitrary load amplitudes via a microstructure-sensitive algorithm with acceptable accuracy as compared to the experiments.

36 MATERIALS SCIENCE↗

The Distribution of U.S. Electric Utility Revenue Decoupling Rate Impacts from 2005 to 2017

Investments in energy efficiency and distributed generation reduce electric utility retail sales. Since electric utilities have historically collected a large portion of revenues from volumetric energy rates (¢/kWh), such reductions in sales can impact the utility’s ability to sufficiently recover non-production costs. Regulatory mechanisms that “decouple” utility revenues from sales were implemented to help make the utility indifferent to energy efficiency and distributed generation by ensuring the utility is able to collect an allowed level of revenue each year regardless of its sales. However, noticeable and consistent surcharges over time may create the perception of an incorrectly designed or implemented decoupling mechanism. To date, there are limited quantitative analyses of the rate adjustments due to decoupling mechanisms implemented among U.S. electric utilities (see Morgan, 2013). Given the recent rapid increase in distributed energy resource (DER) adoption in some states and utility service territories, consumers may be facing more prevalent and ongoing decoupling surcharges. This, in turn, may undermine stakeholder support for implementation of decoupling mechanisms and the associated utility support for energy efficiency and DERs. To determine the size of retail rate adjustments associated with decoupling mechanisms and whether they have a tendency towards bill surcharges or credits, we analyzed a large dataset of historical annual decoupling rate adjustments for 21 electric utilities in 11 states between 2005 and 2017. We found that decoupling mechanisms adjusted rates, both up and down, between rate cases, and the majority of those adjustments (54 percent) are small (within a range of -1 to 1 percent). However, we also found that 64 percent of the rate adjustment observations in our sample showed a positive rate adjustment. Importantly, once a surcharge is applied there is an 86 percent chance that there will be a surcharge in the next year as well. While our analysis did not seek to understand the root causes for such results, some possible factors include the accuracy of revenue requirement forecasts, emerging structural changes in customer use and production of energy, misaligned financial motivation, and other factors that influence sales (e.g., economic recession).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Drivers for the cracking of multilayer polyamide‐based backsheets in field photovoltaic modules: In‐depth degradation mapping analysis

Abstract There is a lack of understanding on the root cause of cracking of photovoltaic (PV) backsheets due to the challenge of multilayer characterization and the complicated failure modes at the submodule level. In this work, the in‐depth degradation mapping of field‐exposed polyamide‐based (PA‐based) PV module backsheets was studied, with the major focus on the identification of underlying drivers for the through cracking (in between the solar cells). PV modules were retrieved from five different locations, comprising a variety of climates, including humid subtropical, hot‐summer Mediterranean, tropical savanna climate, and hot arid. A suite of microscale cross‐sectional characterizations, including chemical changes, fluorescence intensity, and modulus as a function of distance from the air surface of the backsheet, was performed. Results showed more advanced signs of degradation of the inner layer than the outer layer in the cracking region. Increases in the modulus were identified as the major indicator for the cracking. Moreover, a rudimentary test by immersion in acetic acid, which forms during photodegradation of the ethylene‐vinyl acetate copolymer (EVA) encapsulant, showed the first‐time direct evidence that acetic acid can largely accelerate the chemical degradation and facilitate the cracking of PA inner layer. This study suggests that the field cracking of PA‐based backsheet can be attributed to the combined effects of chemical degradation and physical reorganization (chemi‐crystallization) under cyclic thermomechanical stresses. Therefore, it is important to consider effects of local microclimates and interlayer infection to understand the heterogeneous nature of backsheet failures.

Lyu, Yadong↗

Retail Hydrogen Station Reliability Status and Advances

One of the most vital emerging commercial markets for hydrogen is fuel cell-powered mobility including cars, trucks, and buses. These vehicles are refueled via a network of hydrogen fueling stations, with the highest number of U.S. stations being in California. The numbers of both fuel cell electric vehicles (FCEVs) and hydrogen stations have increased in the last two years, with anecdotal information from FCEV drivers indicating that station reliability is hurting the consumer acceptability of FCEV technologies. Therefore, this study benchmarks the current state of hydrogen station reliability in practice and presents on-going research that is investigating the failures that are contribute to hydrogen station reliability issues. This is accomplished with an analysis of operation, safety, and maintenance data from hydrogen stations and fuel cell electric vehicles to benchmark the maintenance and failure of hydrogen stations and their components. This analysis, of over 5,000 station maintenance events, presents the leading maintenance categories and failure rates, and is a prerequisite to the development of data-driven reliability improvement plans. We present a reliability growth analysis and on-going research into the root causes of failure for dispensers, a particularly failure-prone subsystem.

08 HYDROGEN↗

Application of Manufacturing Quality Management Principles to PV System Installations

To help SETO/DOE achieve its goals, the IBTS team proposed a project addressing system reliability by improving installation standards and quality management. The proposed approach was designed to help achieve measurable reductions in installation defect density and improvements in the performance of PV systems by optimizing design and installation of residential and commercial PV systems. This approach addressed the soft costs associated with installations and quality management. The project demonstrated improved system reliability and reduced PV system installation costs. The software developed improved operations, decreased risk, and increased the overall value of PV systems across their lifecycle. The project used several data collection methods, including extensive industry surveys, face-to-face high-level interviews at industry conferences, stakeholder teleconferences, and in-depth interviews conducted by IBTS staff. Results from the research found the industry needs a uniform assessment method for national providers to be more efficient; the software should support both code officials and installers; most industry stakeholders would find value in a centralized software system that allows them to collect, report, and review information on in-process and completed solar installations; and mobile solutions that bridge existing knowledge gaps with inspectors and integrate with existing methodologies (such as permitting software) are of great value. The software solution developed is web-based, allowing for national access, and is built on a Google Firebase platform that can handle significant users and data. It can be used onsite or remotely, allowing for code compliance to continue despite ongoing pandemic related delays or shutdowns for local economies. The information provided by the software tool allows users to uniformly assess a system for compliance and use that aggregated data to identify training topics or create internal process designed to improving issues and reducing occurrence. This solution has multiple benefits in managing quality at time of use and promoting an increase in future safety and quality through education. Perhaps most importantly, this software increases public safety by ensuring compliance of installed systems and allows for local AHJs to remotely engage specialized and qualified solar specific expertise for oversite of the installation in their jurisdictions. Data analysis provides the quality feedback loop identifying the root cause of failure and drives installation practices to improve through training and education, resulting in systems with higher performance, greater reliability, and reduced operations and maintenance costs. With the successful completion of this project, the industry can expect reduced soft costs and increased performance and safety and will ultimately benefit from longer performing systems that cost less to operate.

14 SOLAR ENERGY↗

Thermodynamic analysis of hydrogel swelling in aqueous sodium chloride solutions

Here, a comprehensive thermodynamic model is presented for swelling and salt partitioning of poly (n-isopropyl acrylamide) hydrogels in aqueous sodium chloride (NaCl) solutions at 298 K. Together with a Helmholtz energy expression for network elastic energy, a modified electrolyte Nonradom Two-Liquid activity coefficient model is used to represent both the long-range electrostatic interactions and the short-range van der Waals interactions present in the gel phase. The model parameters include one network parameter per hydrogel system plus two binary parameters per interaction pair in the polymer–solvent-salt systems. With semiquantitave agreement with experimental data for both hydrogel swelling and salt partitioning up to salt saturation, the analysis suggests the ion hydration between NaCl and water is the root cause for hydrogel deswelling in aqueous NaCl solution at high NaCl concentrations, i.e., NaCl weight fraction >0.03. On the other hand, the strong repulsive interaction between NaCl and hydrogel polymer is the dominant factor for salt partitioning.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

Automated Programmable Logic Controller Memory Forensics Using RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and Internet-based technologies has enhanced industrial control system operations but have inadvertently increased their vulnerabilities to cyber attacks. When an industrial control system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies. Memory forensics is critical in the incident analysis process to ascertain what occurred. Approaches for analyzing the persistent memory in industrial control devices are limited and almost nonexistent for volatile memory. This chapter proposes an automated methodology for programmable logic controller memory dump analysis using computer vision and deep learning techniques. The methodology converts the sequences of bytes in a programmable logic controller memory dump to red-green-blue pixels and employs a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. The trained model is employed to automatically segment new memory images and identify forensic artifacts. Evaluation of the methodology on a Schneider Electric Modicon M221 programmable logic controller under code injection and code modification attacks demonstrates its ability to detect attack artifacts in memory dumps.

Asmar Awad, Rima [ORNL] (ORCID:0000000233407742)↗

Drilling Down I/O Bottlenecks with Cross-layer I/O Profile Exploration

I/O performance monitoring tools such as Darshan and Recorder collect I/O-related metrics on production systems and help understand the applications' behavior. However, some gaps prevent end-users from seeing the whole picture when it comes to detecting and drilling down to the root causes of I/O performance slowdowns and where those problems originate. These gaps arise from limitations in the available metrics, their collection strategy, and the lack of translation to actionable items that could advise on optimizations. This paper highlights such gaps and proposes solutions to drill down to the source code level to pinpoint the root causes of I/O bottlenecks scientific applications face by relying on cross-layer analysis combining multiple performance metrics related to I/O software layers. We demonstrate with two real applications how metrics collected in high-level libraries (which are closer to the data models used by an application), enhanced by source-code insights and natural language translations, can help streamline the understanding of I/O behavior and provide guidance to end-users, developers, and supercomputing facilities on how to improve I/O performance. Using this cross-layer analysis and the heuristic recommendations, we attained up to 6.9× speedup from run-as-is executions.

Ather, Hammad↗

IOMiner v0.3

Modern HPC systems are collecting large amounts of I/O performance data. The massive volume and heterogeneity of this data, however, have made timely performance of in-depth integrated analysis difficult. To overcome this difficulty and to allow users to identify the root causes of poor application I/O performance, we developed IOMiner, an I/O log analytics framework.

Byna, Suren↗

Beyond Binary: Automated PLC Memory Forensics through RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and the evolution of industrial control systems (ICS) to adopt Internet-based technologies enhanced productivity, but have inadvertently increased their vulnerability to cyber-based malicious attacks. When an ICS system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies to safeguard against future instances. Memory forensics is critical in the analysis process to ascertain what occurred. To date, approaches to analyze the persistent memory in ICS devices are limited, and almost nonexistent for volatile memory. This paper proposes an automated methodology, COMA, for PLC memory dump analysis using computer vision and deep learning techniques. Specifically, COMA converts the sequences of bytes in a PLC memory dump to RGB pixels and creates a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. COMA then uses the trained model to automatically segment new memory images and extract forensic artifacts. We evaluate COMA on a Schneider Electric Modicon M221 PLC involving two cyber-based attack scenarios: (i) code injection and (ii) code modification. The empirical results show that COMA can successfully detect attack artifacts in memory dumps in both scenarios.

Asmar Awad, Rima↗

Wind turbine main bearing rating lives as determined by IEC 61400‐1 and ISO 281: A critical review and exploratory case study

Abstract This paper studies the rating lives of wind turbine main bearings, as determined by the IEC 61400‐1 and ISO 281 standards. A critical review of relevant bearing life theory and turbine design requirements is provided, including discussion on possible shortcomings such as the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed exploratory case study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity, and contamination levels. Rating lives are found to be sufficiently above the desired 20‐year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are temperature and contamination. Overall, the results of this study suggest that an ISO 281 rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. It is recommended that a similar analysis be undertaken for ISO/TS 16281 rating lives, along with further efforts to identify principal root causes of main bearing failures in future work, possibly leading to a new application standard specific to this component. It is also recommended that the impacts of partial wake impingement on main bearing rating lives are investigated.

17 WIND ENERGY↗

Active multi-mode data analysis to improve fault diagnosis in AHUs

Faults in heating, ventilation and air conditioning systems can lead to increased energy consumption, occupant comfort issues, and reduced equipment lifetime. Commercial fault detection and diagnosis (FDD) tools has been increasingly deployed in U.S. commercial buildings. While they are helping to achieve energy efficiency and operational reliability, there remain gaps in their fault diagnostic capabilities. The diagnostic results often contain multiple distinct candidate root causes (CRCs) or offer no insight into CRCs. This study developed a novel active rule-based multi-mode data analysis method to enhance diagnostic resolution by applying proven rule sets and additional new rules to data from multiple known operational modes. The proposed method was demonstrated using enhanced air handling unit performance assessment rule sets and validated with the simulated data of two air handling units. New metrics, namely, reduced number of CRCs and improvement ratio, were developed to quantify the improvement of fault diagnostic resolution. The validation results showed that the proposed method effectively reduced the number of CRCs in contrast to analyzing data solely for a single mode of operation. It achieved a median improvement ratio of 80% in 19 test cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗