Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

How to design a focusing guide: The large moderator case1

As continuously shaped super-mirrors are becoming available, the conceptual design of focusing guides should explore a wider range of possibilities to accomplish an efficient neutron beam extraction. Starting from a desired phase-space volume at the sample position and using an upstream ray-tracing approach, the acceptance diagram of any focusing guide can be calculated at the moderator position. To ensure high brilliance transfer and homogeneous coverage, the acceptance diagram should be fully included in the neutron source emission phase-space volume. Following this idea, the guide system can be scaled into dimensionless geometric figures that convey performance limits for a desired cross-section reduction. Moreover, if we impose a monotonic increase of the reflection angle with divergence angle at the sample position, the shape of the mirror is analytically determined. This approach was applied in the design of a focusing guide for SNAP instrument at SNS, at ORNL, USA. The results of McStas simulations are presented with different options included. Our approach facilitates finding an optimal solution for connecting multiple guide pieces to avoid excessive losses and ensure a homogeneous phase space coverage.

Frost, Matthew↗

Initial performances of first undulator-based hard x-ray beamlines of NSLS-II compared to simulations

Commissioning of the first X-ray beamlines of NSLS-II included detailed measurements of spectral and spatial distributions of the radiation at different locations of the beamlines, from front-ends to sample positions. Additionally, comparison of some of these measurement results with high-accuracy calculations of synchrotron (undulator) emission and wavefront propagation through X-ray transport optics, performed using SRW code, is presented.

47 OTHER INSTRUMENTATION↗

Issues in the reconstruction of environmental doses on the basis of thermoluminescence measurements in the Techa riverside

The potential of thermoluminescence measurements of bricks from the contaminated area of the Techa river valley, Southern Urals, Russia, for reconstructing external exposures of affected population groups has been studied. Thermoluminescence dating of background samples was used to evaluate the age of old buildings available on the river banks. The anthropogenic gamma dose accrued in exposed samples is determined by subtracting the natural radiation background dose for the corresponding age from the accumulated dose measured by thermoluminescence. For a site in the upper Techa river region, where the levels of external exposures were extremely high, the depth-dose distribution in bricks and the dependence of accidental dose on the height of the sampling position were determined. For the same site, Monte Carlo simulations of radiation transport were performed for different source configurations corresponding to the situation before and after the construction of a reservoir on the river and evacuation of the population in 1956. A comparison of the results provides an understanding of the features of the measured depth-dose distributions and height dependencies in terms of the source configurations and shows that bricks from the higher sampling positions are likely to have accrued a larger fraction of anthropogenic dose from the time before the construction of the reservoir. The applicability of the thermoluminescent dosimetry method to environmental dose reconstruction in the middle Techa region, where the external exposure was relatively low, was also investigated.

NASA Discipline Radiation Health↗

TEAM Electron Microscope Animation

The TEAM Electron Microscope, a device that enables atomic-scale imaging in 3-D, has a rotating stage that can hold and position samples inside electron microscopes with unprecedented stability, position-control accuracy, and range of motion.The TEAM Stage makes one of the world's most powerful electron microscopes even better, and enables previously impossible experiments.

47 OTHER INSTRUMENTATION↗

Properties of large area ErBa2Cu3O(7-x) thin films deposited by ionized cluster beams

ErBa2Cu3O(7-x) films have been produced by simultaneous deposition of Er, Ba, and Cu from three ionized cluster beam (ICB) sources at acceleration voltages of 0.3 to 0.5 kV. Combining ozone oxidation with ICB deposition at 650 C eliminated any need of post annealing processing. The substrates were rotated at 10 rotations per minute during the deposition which took place at a rate of about 3 to 4 nm. Films with areas up to 70 mm in diameter have been made by ICB deposition. These films, 100 nm thick, were deposited on SrTiO3 (100) substrates at 650 C in a mixture of six percent O3 in O2 at a total pressure of 4 x 10(exp -4) Torr. They had T(sub c) ranging from 84.3 K to 86.8 K over a 70 mm diameter and J(sub c) above 10(exp 6) A/sq cm at 77 K. X ray diffraction measurements of the three samples showed preferential c-axis orientation normal to the substrate surface. Scanning electron micrographs (SEM) of the three samples also show some texture dependence on sample position. For the three samples, there is a correlation between SEM texture, full width at half-maximum of rocking curves and J(sub c) versus temperature curves.

Levenson, L. L.↗

Conceptual moderator studies for the Spallation Neutron Source short-pulse second target station

Candidate moderator configurations for a short-pulse second target station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) have been identified using a global optimizer framework built around the MCNPX particle transport code. Neutron brightness metrics were selected as the figure-of-merit. We assumed that STS would use one out of six proton pulses produced by an SNS accelerator upgraded to operate at 1.3 GeV proton energy, 2.8 MW power and 60 Hz repetition rate. The simulations indicate that the peak brightness can be increased by a factor of 5 and 2.5 on a per proton pulse basis compared to the SNS first target station for both coupled and decoupled para-hydrogen moderators, respectively. Additional increases by factors of 3 and 2 were demonstrated for coupled and decoupled moderators, respectively, by reducing the area of neutron emission from 100 × 100 mm{sup 2} to 20 × 20 mm{sup 2}. This increase in brightness has the potential to translate to an increase of beam intensity at the instruments’ sample positions even though the total neutron emission of the smaller moderator is less than that of the larger. This is especially true for instruments with small samples (beam dimensions). The increased fluxes in the STS moderators come at accelerated poison and de-coupler burnout and higher radiation-induced material damage rates per unit power, which overall translate into lower moderator lifetimes. A first effort was undertaken to group decoupled moderators into a cluster collectively positioning them at the peak neutron production zone in the target and having a three-port neutron emission scheme that complements that of a cylindrical coupled moderator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Electrostatic Levitation Facility at NASA's Marshall Space Flight Center

Containerless processing is an important area of research in materials science. Electrostatic levitation (ESL) represents an emerging technology which permits containerless processing in a vacuum environment. NASA's Marshall Space Flight Center (MSFC) established a levitation facility to provide a critical resource to the microgravity materials science research community to continue and enhance ground-based research in the support of the development of flight experiments during the transition to Space Station. During ESL processing, charged specimens are levitated in the electrostatic field produced by the system's electrodes. Three sets of positioning electrodes represent the heart of the MSFC system. Two dual-axis position sensitive detectors provide input for the PID control-loop computer. Sample position is maintained by adjusting the control voltages for the power supplies of the positioning electrodes. A UV source refreshes the charge on specimens during processing via the photoelectric effect. Lasers permit sample heating independent of positioning. The processing chamber typically operates under vacuum condition approximately = 10(exp -7) Torr. Electrostatic levitation provides a materials science research tool for investigations of refractory solids and melts. Topics of investigation include thermophysical properties, phase equilibria, metastable phase formation, undercooling and nucleation, time-temperature-transformation diagrams and other aspects of materials processing. Current capabilities and recent results of processing studies for metals, alloys and oxides will be reviewed.

Rogers, Jan R.↗

The Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: Large-scale structure catalogues for cosmological analysis

ABSTRACT We present large-scale structure catalogues from the completed extended Baryon Oscillation Spectroscopic Survey (eBOSS). Derived from Sloan Digital Sky Survey (SDSS) IV Data Release 16 (DR16), these catalogues provide the data samples, corrected for observational systematics, and random positions sampling the survey selection function. Combined, they allow large-scale clustering measurements suitable for testing cosmological models. We describe the methods used to create these catalogues for the eBOSS DR16 Luminous Red Galaxy (LRG) and Quasar samples. The quasar catalogue contains 343 708 redshifts with 0.8 < z < 2.2 over 4808 deg2. We combine 174 816 eBOSS LRG redshifts over 4242 deg2 in the redshift interval 0.6 < z < 1.0 with SDSS-III BOSS LRGs in the same redshift range to produce a combined sample of 377 458 galaxy redshifts distributed over 9493 deg2. Improved algorithms for estimating redshifts allow that 98 per cent of LRG observations result in a successful redshift, with less than one per cent catastrophic failures (Δz > 1000 km s−1). For quasars, these rates are 95 and 2 per cent (with Δz > 3000 km s−1). We apply corrections for trends between the number densities of our samples and the properties of the imaging and spectroscopic data. For example, the quasar catalogue obtains a χ2/DoF = 776/10 for a null test against imaging depth before corrections and a χ2/DoF= 6/8 after. The catalogues, combined with careful consideration of the details of their construction found here-in, allow companion papers to present cosmological results with negligible impact from observational systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

OpenMSI Arrayed Analysis Tools (OMAAT) v2.0

Mass spectrometry (MS) is an analytical technique that enables all chemical species within a complex mixture to be resolved and identified based on their mass:charge ratio. MS is an increasingly important tool in life science research and development because it can resolve or separate small molecules, peptides, lipids, proteins, biopolymers and fragments of all of these structures. Unfortunately, the use of MS has been limited for lack of software tools to visualize, manipulate, store and transfer MS data. Ben Bowen, Oliver Ruebel and colleagues made a huge advance on the resolution of these limitations with the invention of "OpenMSI" (#2013-004), a computational method that makes the handling of these very large files (up to 50 Tb) much easier, especially for scientists with limited background in bioinformatics or sophisticated software applications of the type needed to handle such data files. With the OpenMSI Arrayed Analysis Tool (OMAAT, #2016-188) invention, the authors take MS data analysis one step further by providing tolls for automatic sample position optimization and ion selection. Even though sample deposition technologies have improved greatly, there is always the chance of encountering outliers in a predefined roster, especially in very large sample sets. Manual curation of the data would be extremely time consuming, so the inventors have included an algorithm that automatically finds the outliers. OMAAT is written in Python with accompanying Jupyter (formerly iPython) notebook and is fully integrated with OpenMSI.

Bowen, Benjamin↗

Investigating Pyroclastic Volcanism in the Taurus-Littrow Valley (TLV) Using the Station 3 Double Drive Tube 73001-73002

Well over 100 pyroclastic deposits have been identified on the Moon. Eruptive processes such as represented by these deposits transported endogenous volatiles from the Moon’s mantle to its surface. Debris from pyroclastic deposits has been identified in all Apollo and Luna samples. The high-Ti pyroclastic de- posit sampled at Shorty Crater by the Station 4 double drive tube (74001-74002) is our best sampling of these types of deposits. Samples 78500 and 78526, NAC images of fissures in the Sculptured Hills, ash identified in 70001-7, and other green volcanic glass indicate that very low-Ti basalt (VLT) erup- tions also occurred in TLV. The double drive tube core being investigated by the ANGSA initiative provides an- other view of TLV pyroclastic eruptions. The regolith in 73001-73002 and the regolith breccias therein have nu- merous pyroclastic beads. Some individual regolith brec- cia fragments have abundant pyroclastic beads (>50 in a polished surface). In this work, we address the following questions. Do these glass beads overlap in composition with those sampled elsewhere in the TLV or do they rec- ord another episode of pyroclastic eruption? Are the magmas associated with pyroclastic eruptions petroge- netically related to the crystalline mare basalts in the TLV? Finally, is the volatile record of the pyroclastic eruptions better preserved in the newly opened and spe- cially contained Station 3 double drive tube core?

C.K. Shearer↗

Incident beam simulations for the CNCS instrument

This data set contains incident beam simulations for the 100 most frequently used configurations of the cold neutron chopper spectrometer (CNCS) instrument at the Spallation Neutron Source. A mcpl output was placed 0.2 m upstream of the sample position. Each file provides enough events to sufficiently sample the beam profile and intensity incident on the sample for that configuration. They can then be used for sample simulations.

47 OTHER INSTRUMENTATION↗

Containerless processing projects

The primary research objective was the examination of fundamental acoustics of the Drop Physics Module. An advanced chamber system was developed for acoustics and sample characterization. Sample interaction with an acoustic field was studied. The shaping of liquid drops by acoustic forces was also examined. The acoustic torque as a function of sample position and shape was studied along with levitated sample stability and the effects of feedback systems.

Source record↗

NASA GRC and MSFC Space-Plasma Arc Testing Procedures

Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

Ferguson, Dale C.↗

NASA GRC and MSFC Space-Plasma Arc Testing Procedures

Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space flight Center (MSFC) for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing testing standardization. To be discussed are: 1. Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debye lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Preventing sustained discharges during testing. 5. Real array or structure samples versus idealized samples. 6. Validity of LEO tests for GEO samples. 7. Extracting arc threshold information from arc rate versus voltage tests. 8 . Snapover and current collection at positive sample bias. Glows at positive bias. Kapton pyrolization. 9. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 10. Testing for Paschen discharge thresholds. Testing for dielectric breakdown thresholds. Testing for tether arcing. 11. Testing in very dense plasmas (ie thruster plumes). 12. Arc mitigation strategies. Charging mitigation strategies. Models. 13. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

Ferguson, Dale C.a↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

36 MATERIALS SCIENCE↗

Contamination concerns in the modular containerless processing facility

This paper describes the problems of the control and management of contamination in the Modular Containerless Processing Facility (MCPF), that is being currently developed at the JPL for the Space Station, and in the MCPF's precursor version, called the Drop Physics Module (DPM), which will be carried aboard one or more Space Shuttle missions. Attention is given to the identification of contamination sources, their mode of transport to the sample positioned within the chamber, and the protection of the sample, as well as to the mathematical simulatiom of the contaminant transport. It is emphasized that, in order to choose and implement the most appropriate contamination control strategy for each investigator, a number of simplified mathematical simulations will have to be developed, and ground-based contamination experiments will have to be carried out with identical materials.

Seshan, P. K.↗

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q -range of typically 0.006–3.2 Å −1 . Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

60 APPLIED LIFE SCIENCES↗

Flexible approach to vibrational sum-frequency generation using shaped near-infrared light

We describe a new approach that expands the utility of vibrational sum-frequency generation (vSFG) spectroscopy using shaped near-infrared (NIR) laser pulses. Here, we demonstrate that arbitrary pulse shapes can be specified to match experimental requirements without the need for changes to the optical alignment. In this way, narrowband NIR pulses as long as 5.75 ps are readily generated, with a spectral resolution of about 2.5 cm -1 , an improvement of approximately a factor of 3 compared to a typical vSFG system. Moreover, the utility of having complete control over the NIR pulse characteristics is demonstrated through nonresonant background suppression from a metallic substrate by generating an etalon waveform in the pulse shaper. The flexibility afforded by switching between arbitrary NIR waveforms at the sample position with the same instrument geometry expands the type of samples that can be studied without extensive modifications to existing apparatuses or large investments in specialty optics.

36 MATERIALS SCIENCE↗