At least 55 records · Page 3

High-Resolution Electrospray Ionization Mass Spectrometry Analysis of Water- Soluble Organic Aerosols Collected with a Particle into Liquid Sampler

This work demonstrates the utility of a particle-into-liquid sampler (PILS) a technique traditionally used for identification of inorganic ions present in ambient or laboratory aerosols for the analysis of water soluble organic aerosol (OA) using high resolution electrospray ionization mass spectrometry (HR ESI-MS). Secondary organic aerosol (SOA) was produced from 0.5 ppm mixing ratios of limonene and ozone in a 5 m3 Teflon chamber. SOA was collected simultaneously using a traditional filter sampler and a PILS. The filter samples were later extracted with either water or acetonitrile, while the aqueous PILS samples were analyzed directly. In terms of peak intensities, types of detectable compounds, average O:C ratios, and organic mass to organic carbon ratios, the resulting high resolution mass spectra were essentially identical for the PILS and filter based samples. SOA compounds extracted from both filter/acetonitrile extraction and PILS/water extraction accounted for >95% of the total ion current in ESI mass spectra. This similarity was attributed to high solubility of limonene SOA in water. In contrast, significant differences in detected ions and peak abundances were observed for pine needle biomass burning organic aerosol (BBOA) collected with PILS and filter sampling. The water soluble fraction of BBOA is considerably smaller than for SOA, and a number of unique peaks were detectable only by the filter/acetonitrile method. The combination of PILS collection with HR-ESI-MS analysis offers a new approach for molecular analysis of the water-soluble organic fraction in biogenic SOA, aged photochemical smog, and BBOA.

09 BIOMASS FUELS↗

Determination of critical experiment correlations using the sampler sequence within scale 6.2 - 14602

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique. (authors)

42 ENGINEERING↗

Small-Noise Analysis and Symmetrization of Implicit Monte Carlo Samplers

Implicit samplers are algorithms for producing independent, weighted samples from multivariate probability distributions. These are often applied in Bayesian data assimilation algorithms. We use Laplace asymptotic expansions to analyze two implicit samplers in the small noise regime. Our analysis suggests a symmetrization of the algorithms that leads to improved implicit sampling schemes at a relatively small additional cost. Here, computational experiments confirm the theory and show that symmetrization is effective for small noise sampling problems.

97 MATHEMATICS AND COMPUTING↗

A new time calibration method for switched-capacitor-array-based waveform samplers

Here we have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. Ultimately, the new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Aerosol Filter Sampler Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the filter sampler.

54 ENVIRONMENTAL SCIENCES↗

A lightweight, high output soil sampler

Sampler is useful on or under earth's surface or on sea bottom. Larger sample amount is obtained relative to sampler size and weight and limited particle size sample material is continuously delivered. Silicone rubber linear in transport tube nearly eliminates grinding or particulate processing during sampling, and reduces required torque.

Howard, E. A.↗

Improved high volume air sampler

Sampler permits size separations of particles by directing sampled air through cross-sectional area sufficiently large that air velocity is reduced to point where particles or larger size will settle out. Sampler conducts air downward and through slots around periphery of unit into relatively open interior of house.

King, R. B.↗

The Viking surface sampler

A surface sampler subsystem for the Viking Lander has been designed, fabricated, cleaned, and successfully tested. Testing has included component level tests to qualification environment and subsystem level tests. This development hardware has also been integrated into a System Test Bed (STB) for the lander system. In addition to the normal dynamic and thermal environments the surface sampler hardware has been tested in an aircraft to simulate the effects of the reduced Martian gravity. Although problems have been encountered with the first-build and integration, the basic design appears to be sound and hardware qualification is scheduled for late 1973.

Seger, R. B.↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

Deyo, J.↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind-sensitive directional air sampler has been developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. Functional testing of a prototype sampler is described; all items exhibited performance and life sufficient to carry out field performance test operations. Life testing of the wind direction sensor and the directional porting valves, which are critical to reliable operation, was emphasized with successful results.

Deyo, J.↗

Mobile Air Sampler

Vehicle-mounted sampler gathers specimens along highways and in tunnels. In contrast to fixed air-collection installations, mobile sampler requires no official approval for use on highways.

Tucker, C. E.↗

Solid-Sorbent Air Sampler

Portable unit takes eight 24-hour samples. Volatile organic compounds in air collected for analysis by portable, self-contained sampling apparatus. Sampled air drawn through sorbent material, commercial porous polymer of 2, 3-diphenyl-p-phenylene oxide. High-boiling-point organic compounds adsorbed onto polymer, while low-boiling-point organics pass through and returned to atmosphere. Sampler includes eight sample tubes filled with polymeric sorbent. Organic compounds in atmosphere absorbed when air pumped through sorbent. Designed for checking air in spacecraft, sampler adaptable to other applications as leak detection, gas-mixture analysis, and ambient-air monitoring.

Galen, T. J.↗

Timing Sampler For Delay Measurements

Integrated circuit called timing sampler used to measure delays in complementary metal oxide/silicon logic gates. Circuit chip contains chains of inverters and metal traces having minimum parasitic delays (delay chains), circuits to compare pulse timings, and output multiplexer. Timing sampler enables delay measurements for both positive and negative logic-level transitions by use of variety of circuit geometries representing tentative practical designs.

Blaes, Brent R.↗

Evaluation of a pneumatic Martian soil sampler concept

The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

Schaefer, John L.↗

A High Volume Stack Sampler

The stack sampler described in this paper has been developed to overcome the difficulties of particulate sampling with presently available equipment. Its use on emissions from hog fuel fired boilers, back-fired incinerators, wigwam burners, asphalt plants, and seed cleaning cyclones is reported. The results indicate that the sampler is rapid and reliable in its use. It is relatively simple and inexpensive to operate. For most sources it should be considered over the more complicated and expensive sampling trains being used and specified.

Boubel, Richard W.↗

Touch and Go Surface Sampler (TGSS)

The Touch and Go Surface Sampler (TGSS) is a new class of planetary and small body sample acquisition tool that can be used for the surface exploration of Europa, Titan and comets. TGSS in its basic configuration consists of a high speed sampling head attached to the end of a flexible shaft. The sampling head consists of counter rotating cutters that rotates at speeds of 3000 to 15000 RPM. The attractive feature of this if touch and go type sampler is that there are no requirements for a lander type spacecraft. Additional information is contained in the original extended abstract.

Gorevan, S. P.↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗