Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCADA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Refurbishment and Automation of the Thermal/Vacuum Facilities at the Goddard Space Flight Center

The thermal/vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the 11 facilities, currently 10 of the systems are scheduled for refurbishment and/or replacement as part of a 5-year implementation. Expected return on investment includes the reduction in test schedules, improvements in the safety of facility operations, reduction in the complexity of a test and the reduction in personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering and for the automation of thermal/vacuum facilities and thermal/vacuum tests. Automation of the thermal/vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs) and the use of Supervisory Control and Data Acquisition (SCADA) systems. These components allow the computer control and automation of mechanical components such as valves and pumps. In some cases, the chamber and chamber shroud require complete replacement while others require only mechanical component retrofit or replacement. The project of refurbishment and automation began in 1996 and has resulted in the computer control of one Facility (Facility #225) and the integration of electronically controlled devices and PLCs within several other facilities. Facility 225 has been successfully controlled by PLC and SCADA for over one year. Insignificant anomalies have occurred and were resolved with minimal impact to testing and operations. The amount of work remaining to be performed will occur over the next four to five years. Fiscal year 1998 includes the complete refurbishment of one facility, computer control of the thermal systems in two facilities, implementation of SCADA and PLC systems to support multiple facilities and the implementation of a Database server to allow efficient test management and data analysis.

Donohue, John T.↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-World Distribution System Modeling Framework for Transmission-and-Distribution Cosimulation: Preprint

This paper presents a modeling methodology for realistic distribution system simulation and analysis. The methodology involves three major approaches: utility model conversion, feeder load modeling, and feeder model validation. The feeder models obtained from the utility are converted to the format that is more flexible for analysis and algorithm development. The load profiles down to each node are modeled in detail using advanced metering infrastructure data and supervisory control and data acquisition (SCADA) system measured load data. Then the distribution system models are validated by comparing the simulated feeder-head voltage results and SCADA measured voltage data. To better understand the bulk system operations and the interactions between transmission and distribution systems, the modeled realistic distribution systems are integrated into a transmission-and-distribution cosimulation framework to perform the system simulation from the bulk system down to each node in the distribution system.

load modeling↗

HIDES (Hybrid Intrusion Detection for Energy Systems) [SWR-19-65]

Hybrid Intrusion Detection for Energy Systems (HIDES) is a conglomerate detector that incorporates three major components: (1) Signature-based detection that involves information technology (IT) related anomaly detection rules, (2) Behavior-based detection that utilizes specially crafted rulesets for detecting abnormal behavior regarding the power system's supervisory control and data acquisition (SCADA) communication streams, and (3) Learning-based detection that combines SCADA communication with phasor measurements to identify otherwise non-detectible attack vectors. The software itself interconnects intrusion detection engine (IDE) enabling communications between the generated OT and IT alerts with phasor measurements for the learning-based detection system. The resulting detection system can detect a wide array of IT, OT, and physical attacks in a real-time setting.

Rivera, Joshua↗

Literature Review of Electromagnetic Pulse (EMP) and Geomagnetic Disturbance (GMD) Effects on Oil and Gas Pipeline Systems

This document summarizes the findings of a review of published literature regarding the potential impacts of electromagnetic pulse (EMP) and geomagnetic disturbance (GMD) phenomena on oil and gas pipeline systems. The impacts of telluric currents on pipelines and their associated cathodic protection systems has been well studied. The existing literature describes implications for corrosion protection system design and monitoring to mitigate these impacts. Effects of an EMP on pipelines is not a thoroughly explored subject. Most directly related articles only present theoretical models and approaches rather than specific analyses and in-field testing. Literature on SCADA components and EMP is similarly sparse and the existing articles show a variety of impacts to control system components that range from upset and damage to no effect. The limited research and the range of observed impacts for the research that has been published suggests the need for additional work on GMD and EMP and natural gas SCADA components.

02 PETROLEUM↗

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain Empowered Provenance Framework for Sensor Identity Management and Data Flow Security in Fossil-based Power Plants

The overall goals of this project are divided into 3 important phases. First, a peer-to-peer SCADA network is to be established where identity profile of sensors from fossil-power plants will be stored in an immutable manner in order to verify data flow integrity in real time. Second, it is aimed to develop a Blockchain-based provenance platform to audit equipment operations along with data and process integrity violations. In this phase, various operational rules will be incorporated in the ledger on behalf of the operating sensor so its abnormal use can be easily detected. In addition, it is aimed to achieve provenance when the rate of transactions is exceedingly high, thus enabling to design a scalable provenance scheme that can work in real time when number of data collecting points or sensor units increase in fossil-based power plants. Finally, a working testbed will be developed to integrate the Blockchain platform with sensor-based fossil power plant comprising of Remote Terminal Units (RTU) and SCADA devices. Using multiple Raspberry-PIs mimicking the role of RTUs that are interfaced with multiple sensors devices will be deployed to serve as a critical component of fossil power plant and the performance metrics such as throughput, latency, bootstrapping time, etc., will be evaluated on the testbed.

20 FOSSIL-FUELED POWER PLANTS↗

Nine Canyon Long-Duration Energy Storage: A Feasibility Study

The Nine Canyon Long Duration Energy Storage (LDES) Feasibility Study explores the technical and economic viability of deploying advanced energy storage technologies at Energy Northwest's (EN) Nine Canyon (9C) Wind Project site in Benton County, Washington. Supported by the Washington State Department of Commerce and the U.S. Department of Energy’s Office of Electricity under its LDES Voucher Program, the study represents a collaborative effort between EN, Pacific Northwest National Laboratory (PNNL), and ARES North America. At the core of this effort is the development of a generalized techno-economic modeling framework and evaluation tool designed to assess the value proposition of LDES projects across a variety of contexts. The modeling tool is technology-agnostic and accommodates user-defined parameters such as rated power, energy duration, round-trip efficiency, capital and operational costs, and dispatch constraints. It also integrates economic inputs, including market prices, energy revenue structures, and financing parameters to evaluate performance through key metrics. The tool provides utilities with a transparent, adaptable platform to support decision-making, investment prioritization, and portfolio planning for various storage technologies. To guide scenario design and interpretation, the study first surveyed the LDES technology landscape, including lithium-ion batteries, flow batteries, non-hydro gravity storage, and thermo-mechanical systems, comparing cost trajectories, technical performance, safety and hazards, materials sourcing and recyclability, and spatial/siting considerations. This literature-grounded review highlights technology trade-offs and reinforces the need to align technology choice with site characteristics, use cases, and project objectives. A companion chapter examines ownership structures (EN ownership, third-party ownership, shared models) and offtake options (energy marketing, capacity/energy PPAs, time-of-use PPAs, block-delivery PPAs, and tolling), where PPAs (power purchase agreements) represent contractual arrangements for buying and selling electricity. The chapter also highlights implications for risk allocation, capital access, operational control, and revenue certainty. The study also evaluates supervisory control and data acquisition (SCADA) and transmission interconnection pathways, options include upgrading the existing SCADA or deploying a dedicated LDES controller, with attention to protection schemes, data telemetry, cybersecurity, and regulatory coordination with BPA. In addition, an ARES-specific geotechnical and hydrology assessment presented in the appendix screens multiple corridors for slope stability, bearing capacity, cut-and-fill magnitude, and stormwater behavior.

25 ENERGY STORAGE↗

Cybersecurity Center for Offshore Wind Energy (Final Project Report)

This project establishes a Cybersecurity Center for Offshore Wind Energy with the objective of designing and operating a cyber-physical testbed for wind energy farms (WEFs) that enables comprehensive cybersecurity research. The testbed incorporates a Supervisory Control and Data Acquisition (SCADA) system connected to turbine models via industrial-grade programmable logic controllers (PLCs) and remote terminal units (RTUs). It supports side-channel data acquisition, implementation and analysis of various cyberattack scenarios, and development of attack detection, mitigation, and best-practice guidance tailored to wind energy systems. During the project, the team expanded the number and fidelity of mathematical turbine models (MTMs), integrated these models with SCADA infrastructure, and deployed a scaled physical turbine and associated sensors. High-resolution operational and side-channel data streams were collected and used to refine machine-learning (ML)-based attack detection systems and to extend the WindCRAFT framework to multi-turbine threat scenarios. The project demonstrated a realistic, scalable environment for evaluating cyber threats, validated attack detection approaches using enriched datasets, and identified new multi-turbine and inter-turbine communication attack vectors. The resulting testbed, models, and security mechanisms provide a foundation for ongoing R&D and deployment of cyber-resilient offshore wind energy systems.

17 WIND ENERGY↗

Added value of site load measurements in probabilistic lifetime extension: a Lillgrund case study

Site-specific fatigue estimation is an essential part of wind turbine lifetime extension, with various methods depending on data availability. The present study compares probabilistic lifetime extension assessment results for rotor blades with and without load measurements. It also addresses two key questions in such assessments: the applicability of the Frandsen model for estimating waked turbulence under complex and mixed wake conditions and the extrapolation of mid-term data over longer time periods. The case study wind turbine is SWT-2.3-93, located at the edge of the Lillgrund wind farm, situated in the Øresund Strait between Denmark and Sweden. The turbine is extensively instrumented, with 5 years of data available from its supervisory control and data acquisition (SCADA) system. Although the Frandsen turbulence estimates deviate in a different manner from measurements at below- and above-rated mean wind speeds, the model remains a conservative approach for fatigue load prediction and reliability. In the current case study, the site-specific assessment using strain gauge measurements yields a 33 % higher annual fatigue reliability index after 35 years compared to a scenario based on the Frandsen estimation combined with ambient environmental data and a generic aeroelastic model. The results also demonstrate that the sensitivity of fatigue reliability to load uncertainty is negligible when load measurements are used directly but relatively high when relying on the Frandsen model in combination with a generic aeroelastic model. Overall, the high variability of the lifetime extension in different scenarios of data availability and accuracy shows the importance and added value of high-quality measurements combined with wind-farm-level SCADA and a model updated in real time (digital twins).

17 WIND ENERGY↗

Gearbox bearing crack growth prognostics and uncertainty quantification with physics-informed machine learning

This paper introduces the extreme theory of functional connections (X-TFC), a physics-informed machine learning algorithm, and tailors it to estimate the remaining useful life (RUL) of wind turbine gearbox bearings experiencing fatigue crack growth. Unlike purely data-driven methods, X-TFC embeds a physics model, based on Head's theory in this work, into its training objective. The core of X-TFC is a random-projection single-layer neural network trained via an extreme learning machine, which requires only limited damage progression data and solves for output weights with a least-squares optimization algorithm. A composite loss function balances the network's fit to observed degradation data against the residuals of the governing crack growth differential equation, ensuring the learned damage trajectory remains physically plausible. When applied to a vibration-based health-index (HI) dataset measured during the growth of a crack on the inner ring of a high-speed bearing in a wind turbine gearbox (Bechhoefer and Dubé, 2020), X-TFC achieves near-zero prediction bias. Even when trained on only the first 10 %–20 % of the damage progression data, with sufficient physics weighting its predictions remain monotonic and smooth, delivering high prognosability and trendability. To quantify the epistemic uncertainty, we employ a Monte Carlo ensemble of independently initialized X-TFC models trained on noise-perturbed data, which yields confidence intervals around each RUL estimate and captures both model-parameter and epistemic uncertainty. In addition to a vibration-based HI, we demonstrate that the proposed framework can be directly applied to a supervisory control and data acquisition (SCADA) data-based HI (Eftekhari Milani et al., 2026) measured during similar wind turbine gearbox bearing crack faults, preserving its accuracy and interpretability. This extension shows the versatility of our approach, which is applicable to bearings of multiple gearbox manufacturers, models, and ratings using only SCADA data. By integrating domain knowledge with machine learning, X-TFC offers a rapid, reliable tool for crack prognostics. Its adaptability to other bearing failure modes, such as pitch bearing ring cracks, positions X-TFC as a powerful enabler of data-driven, physics-informed asset management in the wind energy sector and beyond.

17 WIND ENERGY↗

Design and analysis of a wake model for spatially heterogeneous flow

Abstract. Methods of turbine wake modeling are being developed to more accurately account for spatially variant atmospheric conditions within wind farms. Most current wake modeling utilities are designed to apply a uniform flow field to the entire domain of a wind farm. When this method is used, the accuracy of power prediction and wind farm controls can be compromised depending on the flow-field characteristics of a particular area. In an effort to improve strategies of wind farm wake modeling and power prediction, FLOw Redirection and Induction in Steady State (FLORIS) was developed to implement sophisticated methods of atmospheric characterization and power output calculation. In this paper, we describe an adapted FLORIS model that features spatial heterogeneity in flow-field characterization. This model approximates an observed flow field by interpolating from a set of atmospheric measurements that represent local weather conditions. The objective of this method is to capture heterogeneous atmospheric effects caused by site-specific terrain features, without explicitly modeling the geometry of the wind farm terrain. The implemented adaptations were validated by comparing the simulated power predictions generated from FLORIS to the actual recorded wind farm output from the supervisory control and data acquisition (SCADA) recordings and large eddy simulations (LESs). When comparing the performance of the proposed heterogeneous model to homogeneous FLORIS simulations, the results show a 14.6 % decrease for mean absolute error (MAE) in wind farm power output predictions for cases using wind farm SCADA data and a 18.9 % decrease in LES case studies. The results of these studies also indicate that the efficacy of the proposed modeling techniques may vary with differing site-specific operational conditions. This work quantifies the accuracy of wind plant power predictions under heterogeneous flow conditions and establishes best practices for atmospheric surveying for wake modeling.

17 WIND ENERGY↗

Anomaly Detection in Power Quality at Data Centers

The goal during my internship at the National Center for Critical Information Processing and Storage (NCCIPS) is to implement an anomaly detection method through the StruxureWare SCADA Power Monitoring system. The benefit of the anomaly detection mechanism is to provide the capability to detect and anticipate equipment degradation by monitoring power quality prior to equipment failure. First, a study is conducted that examines the existing techniques of power quality management. Based on these findings, and the capabilities of the existing SCADA resources, recommendations are presented for implementing effective anomaly detection. Since voltage, current, and total harmonic distortion demonstrate Gaussian distributions, effective set-points are computed using this model, while maintaining a low false positive count.

Grichine, Art↗

Updating the Thermal Vacuum Chambers at the NASA Johnson Space Center

Chambers A and B are two large thermal vacuum chambers at Johnson Space Center which enable space simulation for unmanned and human-rated missions, respectively. With the resurgence in deep space missions for scientific research and various private commercial ventures, these chambers are expected to be used frequently for at least the next decade. For qualifying the James Webb Space Telescope, upgrades to Chamber A were performed which included the addition of a 12.5 kW refrigeration system with helium shrouds capable of simulating deep space environment and an efficient and reliable LN2 natural flow thermosiphon system for the thermal shield. Continuous improvements since then have focused on ensuring operational readiness by modernizing the data acquisition, recording, controls, and visualization systems for both chambers and clean room. These upgrades will be the focus of this paper. Controlling the Cryochambers was enhanced by moving from a 32-bit SCADA system to a 64-bit architected system. Infrastructural changes involved installing redundant power circuits, adding new servers, network switches, and including load balancing with fail-over between servers to minimize downtime. Instead of distributed servers, 3 redundant servers are used to share configurations. Configurations are now kept in a shared SQL instance making it easy to deploy and maintain. During this upgrade process many sub-systems (PLCs and NI PXI interfaces to sensors) were upgraded from the prior OPC-DA to the more secure OPC-UA protocol. Cryo-system PLCs were updated to allow Ganni cycle floating pressure calculations from any cold box to be sent to any compressor. During the project, the team recreated over 70,000 live data points, 50000 historical data points, and 4000 alarms. Finally, the graphical interfaces were upgraded to support HTML 5 in conjunction shared pages were implemented reducing the total number of webpages by over 75%. These system updates reinvigorated the previous SCADA system which had reached its end of life. The same look and feel was maintained while providing operators with an updated interface to control, troubleshoot, and record. The new system architecture is more robust and easier to maintain creating a path forward to address remaining problem points and implement additional features.

Cody Schaefer↗

Updating the Thermal Vacuum Chambers at the NASA Johnson Space Center

Chambers A and B are two large thermal vacuum chambers at Johnson Space Center which enable space simulation for unmanned and human-rated missions, respectively. With the resurgence in deep space missions for scientific research and various private commercial ventures, these chambers are expected to be used frequently for at least the next decade. For qualifying the James Webb Space Telescope, upgrades to Chamber A were performed which included the addition of a 12.5 kW refrigeration system with helium shrouds capable of simulating deep space environment and an efficient and reliable LN2 natural flow thermosiphon system for the thermal shield. Continuous improvements since then have focused on ensuring operational readiness by modernizing the data acquisition, recording, controls, and visualization systems for both chambers and clean room. These upgrades will be the focus of this paper. Controlling the Cryochambers was enhanced by moving from a 32-bit SCADA system to a 64-bit architected system. Infrastructural changes involved installing redundant power circuits, adding new servers, network switches, and including load balancing with fail-over between servers to minimize downtime. Instead of distributed servers, 3 redundant servers are used to share configurations. Configurations are now kept in a shared SQL instance making it easy to deploy and maintain. During this upgrade process many sub-systems (PLCs and NI PXI interfaces to sensors) were upgraded from the prior OPC-DA to the more secure OPC-UA protocol. Cryo-system PLCs were updated to allow Ganni cycle floating pressure calculations from any cold box to be sent to any compressor. During the project, the team recreated over 70,000 live data points, 50000 historical data points, and 4000 alarms. Finally, the graphical interfaces were upgraded to support HTML 5 in conjunction shared pages were implemented reducing the total number of webpages by over 75%. These system updates reinvigorated the previous SCADA system which had reached its end of life. The same look and feel was maintained while providing operators with an updated interface to control, troubleshoot, and record. The new system architecture is more robust and easier to maintain creating a path forward to address remaining problem points and implement additional features.

Cody Schaefer↗

Network visualization, intrusion detection, and network healing

The present disclosure is related to a cyber-security system that includes a Supervisory Control and Data Acquisition (SCADA) network monitor configured to receive a data set from a power system network, an event manager, and a mitigation system, where the SCADA network monitor includes an anomaly detector.

Rivera, Joshua Eli↗

Predicting wind farm operations with machine learning and the P2D‐RANS model: A case study for an AWAKEN site

Abstract The power performance and the wind velocity field of an onshore wind farm are predicted with machine learning models and the pseudo‐2D RANS model, then assessed against SCADA data. The wind farm under investigation is one of the sites involved with the American WAKE experimeNt (AWAKEN). The performed simulations enable predictions of the power capture at the farm and turbine levels while providing insights into the effects on power capture associated with wake interactions that operating upstream turbines induce, as well as the variability caused by atmospheric stability. The machine learning models show improved accuracy compared to the pseudo‐2D RANS model in the predictions of turbine power capture and farm power capture with roughly half the normalized error. The machine learning models also entail lower computational costs upon training. Further, the machine learning models provide predictions of the wind turbulence intensity at the turbine level for different wind and atmospheric conditions with very good accuracy, which is difficult to achieve through RANS modeling. Additionally, farm‐to‐farm interactions are noted, with adverse impacts on power predictions from both models.

17 WIND ENERGY↗