Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

W-Band ARM Scanning Cloud Radar (WSACR) 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Co-Polarization Mode (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

W-Band ARM Scanning Cloud Radar (WSACR) 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Cross Mode (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

W-Band ARM Scanning Cloud Radar (WSACR) 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Cross-Polarization Model (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

Electronic Scanning Strategies in Adaptive Electrical Capacitance Volume Tomography: Tradeoffs and Prospects

Electrical Capacitance Volume Tomography (ECVT) has been applied for imaging of multiphase flows found in industrial applications. The ill-posed nature of the image reconstruction problem in ECVT and the consequent low resolution can be alleviated by employing electronic scanning enabled by electrode segmentation and reconfiguration during data acquisition. Here we study electronic scanning strategies that mimic physical rotation and shifting of the sensor along its symmetry axis. First, we study the feasibility of electronic scanning by analyzing the capacitance transducer circuit in SPICE. Then, we simulate electronic scanning using the finite element method for different electrode shapes, for which we compare the image reconstruction results and acquisition time. We find a noticeable improvement in image resolution for the scanning cases over conventional ECVT. Lastly, among the scanning cases, we emphasize a particular electrode shape that provides the best image resolution along with the minimal amount of acquisition time.

47 OTHER INSTRUMENTATION↗

Safer and optimized vulnerability scanning for operational technology through integrated and automated passive monitoring and active scanning

Vulnerability scanning of embedded sensors and controllers have a history of causing disruption and malfunction within operation technology environments. Traditional information technology vulnerability scanning generally consists of blunt exercising all or a large population of test conditions to understand how equipment responds. Often the large number and varied conditions of the tests are too much for embedded systems to handle. This paper presents a methodology and framework for integrating passive monitoring and active scanning techniques to optimize the type and amount of necessary active communication tests while achieving acceptable levels of device and vulnerability discovery. Bayesian probability and networks are leveraged for inference to drive the automation of the scanning actions to achieve confidence in discovery. Through inference, selecting the optimal active scans with the least risk and highest confidence impact is possible, thereby eliminating unnecessary scans with uncertain effects. Results of experimenting with real power systems and the following probabilities are provided.

Key Management, ICS, SCADA, Authentication↗

Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast Scanning Probe Microscopy via Machine Learning: Non-Rectangular Scans with Compressed Sensing and Gaussian Process Optimization

Fast scanning probe microscopy enabled via machine learning allows for a broad range of nanoscale, temporally resolved physics to be uncovered. However, such examples for functional imaging are few in number. Here, using piezoresponse force microscopy (PFM) as a model application, a factor of 5.8 reduction in data collection using a combination of sparse spiral scanning with compressive sensing and Gaussian process regression reconstruction is demonstrated. It is found that even extremely sparse spiral scans offer strong reconstructions with less than 6% error for Gaussian process regression reconstructions. Further, the error associated with each reconstructive technique per reconstruction iteration is analyzed, finding the error is similar past ≈15 iterations, while at initial iterations Gaussian process regression outperforms compressive sensing. Finally, this study highlights the capabilities of reconstruction techniques when applied to sparse data, particularly sparse spiral PFM scans, with broad applications in scanning probe and electron microscopies.

36 MATERIALS SCIENCE↗

Lidar arc scan uncertainty reduction through scanning geometry optimization

Abstract. Doppler lidars are frequently operated in a mode referred to as arc scans, wherein the lidar beam scans across a sector with a fixed elevation angle and the resulting measurements are used to derive an estimate of the n minute horizontal mean wind velocity (speed and direction). Previous studies have shown that the uncertainty in the measured wind speed originates from turbulent wind fluctuations and depends on the scan geometry (the arc span and the arc orientation). This paper is designed to provide guidance on optimal scan geometries for two key applications in the wind energy industry: wind turbine power performance analysis and annual energy production prediction. We present a quantitative analysis of the retrieved wind speed uncertainty derived using a theoretical model with the assumption of isotropic and frozen turbulence, and observations from three sites that are onshore with flat terrain, onshore with complex terrain and offshore, respectively. The results from both the theoretical model and observations show that the uncertainty is scaled with the turbulence intensity such that the relative standard error on the 10 min mean wind speed is about 30 % of the turbulence intensity. The uncertainty in both retrieved wind speeds and derived wind energy production estimates can be reduced by aligning lidar beams with the dominant wind direction, increasing the arc span and lowering the number of beams per arc scan. Large arc spans should be used at sites with high turbulence intensity and/or large wind direction variation.

47 OTHER INSTRUMENTATION↗

Simultaneous scanning near-field optical and X-ray diffraction microscopy for correlative nanoscale structure-property characterization

A multimodal imaging instrument has been developed that integrates scanning near-field optical microscopy with nanofocused synchrotron X-ray diffraction imaging. The instrument allows for the simultaneous nanoscale characterization of electronic/near-field optical properties of materials together with their crystallographic structure, facilitating the investigation of local structure–property relationships. The design, implementation and operating procedures of this instrument are reported. The scientific capabilities are demonstrated in a proof-of-principle study of the insulator–metal phase transition in samarium sulfide (SmS) single crystals induced by applying mechanical pressure via a scanning tip. The multimodal imaging of an in situ tip-written region shows that the near-field optical reflectivity can be correlated with the heterogeneously transformed structure of the near-surface region of the crystal.

insulator–metal transitions↗

Characterization of two-dimensional hexagonal boron nitride using scanning electron and scanning helium ion microscopy

Characterization of the structural and physical properties of two-dimensional (2D) materials, such as layer number and inelastic mean free path measurements, is very important to optimize their synthesis and application. In this study, we characterize the layer number and morphology of hexagonal boron nitride (h-BN) nanosheets on a metallic substrate using field emission scanning electron microscopy (FE-SEM) and scanning helium ion microscopy (HIM). Using scanning beams of various energies, we could analyze the dependence of the intensities of secondary electrons on the thickness of the h-BN nanosheets. Based on the interaction between the scanning particles (electrons and helium ions) and h-BN nanosheets, we deduced an exponential relationship between the intensities of secondary electrons and number of layers of h-BN. With the attenuation factor of the exponential formula, we calculate the inelastic mean free path of electrons and helium ions in the h-BN nanosheets. Our results show that HIM is more sensitive and consistent than FE-SEM for characterizing the number of layers and morphology of 2D materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Holistic scan optimization of nacelle-mounted lidars for inflow and wake characterization at the RAAW and AWAKEN field campaigns

In this article, we provide a methodological framework for designing the scanning strategies of nacelle-mounted scanning lidars for wind energy field experiments, and apply it at two major experimental field campaigns. For the Rotor Aerodynamics, Aeroelastics, and Wake project (RAAW), we leverage two scanning lidars on one turbine to characterize the incoming turbulence and the turbine wake. For the American WAKE experimeNt (AWAKEN), we use four scanning lidars on top of four turbines in a large wind power plant to investigate both individual wakes and wind-plant-scale flow features.

17 WIND ENERGY↗

TLSLEAF: Automatic Leaf Angle Estimates From Single-Scan Terrestrial Laser Scanning

Leaf angle distribution (LAD) in forest canopies affects estimates of leaf area, light interception, and global-scale photosynthesis, but is often simplified to a single theoretical value. Here, we present TLSLeAF (Terrestrial Laser Scanning Leaf Angle Function), an automated open-source method of deriving LADs from terrestrial laser scanning. TLSLeAF produces canopy-scale leaf angle and LADs by relying on gridded laser scanning data. The approach increases processing speed, improves angle estimates, and requires minimal user input. Key features are automation, leaf–wood classification, beta parameter output, and implementation in R to increase accessibility for the ecology community. TLSLeAF precisely estimates leaf angle with minimal distance effects on angular estimates while rapidly producing LADs on a consumer-grade machine. We challenge the popular spherical LAD assumption, showing sensitivity to ecosystem type in plant area index and foliage profile estimates that translate to c. 25% and c. 11% increases in canopy net photosynthesis (c. 25%) and solar-induced chlorophyll fluorescence (c. 11%). TLSLeAF can now be applied to the vast catalog of laser scanning data already available from ecosystems around the globe. The ease of use will enable widespread adoption of the method outside of remote-sensing experts, allowing greater accessibility for addressing ecological hypotheses and large-scale ecosystem modeling efforts.

3D↗

Advances and Challenges of SCAN and r 2 SCAN Density Functionals in Transition‐Metal Compounds

ABSTRACT Transition‐metal compounds (TMCs) with open‐shell d ‐electrons are characterized by a complex interplay of lattice, charge, orbital, and spin degrees of freedom, giving rise to various fascinating applications. Often exhibiting exotic properties, these compounds are commonly classified as correlated systems due to strong inter‐electronic interactions called Hubbard U . This inherent complexity presents significant challenges to Kohn‐Sham density functional theory (KS‐DFT), the most widely used electronic structure method in condensed matter physics and materials science. While KS‐DFT is, in principle, exact for the ground‐state total energy, its exchange‐correlation energy must be approximated in practice. The mean‐field nature of KS implementations, combined with the limitations of current exchange‐correlation density functional approximations, has led to the perception that DFT is inadequate for correlated systems, particularly TMCs. Consequently, a common workaround involves augmenting DFT with an on‐site Hubbard‐like U correction. In recent years, the strongly constrained and appropriately normed (SCAN) density functional, along with its refined variant r 2 SCAN, has achieved remarkable progress in accurately describing the structural, energetic, electronic, magnetic, and vibrational properties of TMCs, challenging the traditional perception of DFT's limitations. This review explores the design principles of SCAN and r 2 SCAN, highlights their key advancements in studying TMCs, explains the mechanisms driving these improvements, and addresses the remaining challenges in this evolving field.

Zhang, Yubo [Minjiang Collaborative Center for The↗

Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A visual evaluation of the spatial resolution using the x-ray test pattern indicated that the resolution was 1.8 lp/mm at the IFP and 1.2 lp/mm at heights of −100 and 100 mm from the IFP. The authors demonstrated that a spatial resolution of 1.2–1.8 lp/mm could be obtained within heights of 200 mm of the IFP. The slice sensitivity varied between 11.1 and 13.8 mm for heights between −50 and 100 mm, and there was no critical change in the slice sensitivity within a height range of 150 mm around the IFP. The phantom results demonstrated that tomosynthesis and long-view images could be reconstructed. Conclusions: PS-TS-F provides tomosynthesis images while using low-cost systems that have no tomographic scanning function, such as tableside-controlled universal R/F systems or universal radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-206-06: Analytic Dose Function for CT Scans in Infinite Cylinders as a Function of Scan Length and Cylinder Radius

Purpose: The radiation dose absorbed at a particular radius ρ within the central plane of a long cylinder following a CT scan is a function of the length of the scan L and the cylinder radius R along with kVp and cylinder composition. An analytic function was created that that not only expresses these dependencies but is integrable in closed form over the area of the central plane. This feature facilitates explicit calculation of the planar average dose. The “approach to equilibrium” h(L) discussed in the TG111 report is seamlessly included in this function. Methods: For a cylindrically symmetric radiation field, Monte Carlo calculations were performed to compute the dose distribution to long polyethylene cylinders for scans of varying L for cylinders ranging in radius from 5 to 20 cm. The function was developed from the resultant Monte Carlo data. In addition, the function was successfully fit to data taken from measurements on the 30 cm diameter ICRU/TG200 phantom using a real-time dosimeter. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. There are competing effects as the beam penetrates the cylinder from the outside: attenuation, resulting in a decrease; scatter, abruptly increasing at the circumference. This competition may result in an absolute maximum between the center and outer edge leading to a “gull wing” shape for the radial dependence. For the smallest cylinders, scatter may dominate to the extent that there is an absolute maximum at the center. Conclusion: An integrable, analytic function has been developed that provides the radial dependency of dose for the central plane of a scan of length L for cylinders of varying diameter. Equivalently, we have developed h(L,R,ρ).

60 APPLIED LIFE SCIENCES↗