Search NASA⌕ Search

SEARCH · Search NASA

Results for “SILICON RADIATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurement of LET distribution and dose equivalent on board the space shuttle STS-65

Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD)" utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 microSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5 degrees) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15-200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.

manned↗

Radiation Effects of Protons and Electrons in Silicon Diffused-Junction Detectors

Diffused n-on-p silicon particle detectors were irradiated with 1-Mev electrons, and with 31-Mev and 8.2-Mev protons. The detector capacitance was observed to increase with electron irradiation and to decrease with proton irradiation. A physical interpretation is given in terms of defect energy levels known to be introduced in silicon by irradiation. Defect ionization states are taken to be characteristic of the space-charge region, rather than of bulk silicon. The relation to other studies of damage in semiconductor particle detectors is pointed out, considering differences in the types of detector and irradiation used. The significance of these results is discussed for detector applications where the damage threshold is exceeded.

Scott, R. E.↗

Imaging antenna array at 119 microns

A focal-plane imaging antenna array has been demonstrated at 119 microns. The array is a line of evaporated silver bow-tie antennas with bismuth microbolometer detectors on a silicon substrate. Radiation is coupled into the array by a lens placed on the back of the substrate. The bolometers are thermally isolated from the silicon substrate with a half-micron layer of polyimide. The array performance is demonstrated by coherent imaging of a series of holes at half the diffraction-limited cut-off frequency.

Neikirk, N. P.↗

Laboratory characterization of direct readout Si:Sb and Si:Ga infrared detector arrays

Highlights of recent results obtained at Ames Research Center in performance evaluations of infrared detector arrays are presented. Antimony- and gallium-doped silicon direct readout 58x62 element hybrid devices from Ames' ongoing detector technology development program are described. The observed characteristics meet most of the performance goals specified by the Space Infrared Telescope Facility (SIRTF) instrument teams and compare favorably with the best performance reported for discrete non-integrating extrinsic silicon detectors. Initial results of radiation environment testing are reported, and non-ideal behavior demonstrated by these test devices is discussed.

Mckelvey, Mark E.↗

The development of infrared detectors and mechanisms for use in future infrared space missions

The environment above earth's atmosphere offers significant advantages in sensitivity and wavelength coverage in infrared astronomy over ground-based observatories. In support of future infrared space missions, technology development efforts were undertaken to develop detectors sensitive to radiation between 2.5 micron and 200 micron. Additionally, work was undertaken to develop mechanisms supporting the imaging and spectroscopy requirements of infrared space missions. Arsenic-doped-Silicon and Antimony-doped-Silicon Blocked Impurity Band detectors, responsive to radiation between 4 micron and 45 micron, were produced in 128x128 picture element arrays with the low noise, high sensitivity performance needed for space environments. Technology development continued on Gallium-doped-Germanium detectors (for use between 80 micron and 200 micron), but were hampered by contamination during manufacture. Antimony-doped-Indium detectors (for use between 2.5 micron and 5 micron) were developed in a 256x256 pixel format with high responsive quantum efficiency and low dark current. Work began on adapting an existing cryogenic mechanism design for space-based missions; then was redirected towards an all-fixed optical design to improve reliability and lower projected mission costs.

Houck, James R.↗

High-energy neutron spectroscopy with thick silicon detectors

The high-energy neutron component of the space radiation environment in thick structures such as the International Space Station contributes to the total radiation dose received by an astronaut. Detector design constraints such as size and mass have limited the energy range of neutron spectrum measurements in orbit to about 12 MeV in Space Shuttle studies. We present a new method for high-energy neutron spectroscopy using small silicon detectors that can extend these measurements to more than 500 MeV. The methodology is based on measurement of the detector response function for high-energy neutrons and inversion of this response function with measured deposition data to deduce neutron energy spectra. We also present the results of an initial shielding study performed with the thick silicon detector system for high-energy neutrons incident on polyethylene.

Non-NASA Center↗

Methods of measurement for semiconductor materials, process control, and devices

Activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices are described. Topics investigated include: measurements of transistor delay time; application of the infrared response technique to the study of radiation-damaged, lithium-drifted silicon detectors; and identification of a condition that minimizes wire flexure and reduces the failure rate of wire bonds in transistors and integrated circuits under slow thermal cycling conditions. Supplementary data concerning staff, standards committee activities, technical services, and publications are included as appendixes.

Bullis, W. M.↗

A high resolution semiconductor detector for applications in space

Nuclear radiation detectors with volumes of approximately 1 cu cm was fabricated from single crystals of germanium-silicon alloy containing as much as 20 weight percent germanium. The properties of these detectors were investigated and will be discussed. Tests reveal that the gamma ray photoelectric peak efficiency of an alloy detector with only 12 weight percent germanium is approximately 4 times that of a silicon detector of equal volume. The room temperature roomure appears to be a good possibility. Storage for long periods at room temperature does not seem to adversely affect these devices. The results of preliminary radiation damage experiments suggest that the alloy detectors possess a radiation damage resistance far greater than that of silicon.

Alexander, P.↗

Advanced Radiation Detectors and Detector Systems Research

Real‐time awareness of space radiation is critical for missions beyond LEO. Missions to the Moon, Mars, Near‐Earth‐Objects (NEOs), inner and outer planets, as well as other destinations in space, will require embedded instrumentation to provide feedback for “smart”, adaptive control systems. Precision instrumentation will also be needed to provide improved data for space radiation modeling and space weather forecasting and awareness. Compact instrumentation on small platforms such as CubeSats and other small space‐faring vehicles will provide a better understanding of the space radiation environment by supplying data from multiple locations in space where information is yet unknown. Compact integrable solid‐state detectors with low noise and high tolerance of operation in a radiation environment are enabled by the application of Wide Band Gap semiconductors as radiation detectors. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies that enable improved instruments for space science missions. A variety of radiation detectors are under development, such as silicon carbide semiconductor detectors, for applications to space science, lunar prospecting, and fission power systems.

Field and particle detectors↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

Tunable Antireflection Layers for Planar Bolometer Arrays

It remains a challenge to obtain high-efficiency coupling of far-infrared through millimeter radiation to large-format detector arrays. The conventional approach of increasing detector coupling is to use reflective backshorts. However, this approach often results in excessive systematic errors resulting from reflections off the backshort edge. An alternate approach to both increasing quantum efficiency and reducing systematics associated with stray light is to place an antireflective coating near the front surface of the array. When incorporated with a resistive layer and placed behind the detector focal plane, the AR coating can serve to prevent optical ghosting by capturing radiation transmitted through the detector. By etching a hexagonal pattern in silicon, in which the sizes of the hexes are smaller than the wavelength of incident radiation, it is possible to fabricate a material that has a controllable dielectric constant, thereby allowing for simple tunable optical device fabrication. To this end, we have fabricated and tested tunable silicon "honeycomb" AR layers and AR/resistive layer devices. These devices were fabricated entirely out of silicon in order to eliminate problems associated with differential contraction upon detector cooling.

Brown, Ari-David↗

Silicon Detector System for Cross Section Measurements

In order to estimate the radiation shielding effectiveness of materials it is necessary to know cosmic ray particles are broken up as they pass though these materials. The breakup of cosmic ray particles is characterized by the nuclear fragmentation cross sections, i.e. an effective geometrical cross section assigned to each target nucleus that represents its apparent size for fragmenting the incident particle. The values of these cross sections depend on the details of nuclear physics and cannot be calculated from first principles owing to the many-body nature of the interactions. The only way to determine them is to measure them. Once a sufficient number of cross sections have been measured, the systematic nature of the interactions allows other cross-sections to be estimated. The number of cross sections that contribute to the estimation of shielding effectiveness is very large 10,000. Fortunately most make minor contributions. These can be estimated from nuclear systematics. Only those who's uncertainties make significant contributions to the error in the shielding effectiveness estimations need to be measured. In the past it has proven difficult to measure light fragment production cross sections from the interactions of heavy cosmic rays owing to the size of the detectors used. We have developed a highly pixilated silicon (Si) detector system that can individually identify these light fragments while making efficient use of costly accelerator time. This system is an outgrowth of detector technology developed under a CDDF and a Code S sponsored cosmic ray experiment.

Source record↗

Multidirectional Cosmic Ray Ion Detector for Deep Space CubeSats

Understanding the nature of anisotropy of solar energetic protons (SEPs) and galactic cosmic ray (GCR) fluxes in the interplanetary medium is crucial in characterizing time-dependent radiation exposure in interplanetary space for future exploration missions. NASA Glenn Research Center has proposed a CubeSat-based instrument to study solar and cosmic ray ions in lunar orbit or deep space. The objective of Solar Proton Anisotropy and Galactic cosmic ray High Energy Transport Instrument (SPAGHETI) is to provide multi-directional ion data to further understand anisotropies in SEP and GCR flux. The instrument is to be developed using large area detectors fabricated from high density, high purity silicon carbide (SiC) to measure linear energy transfer (LET) of ions. Stacks of these LET detectors are arranged in a CubeSat at orthogonal directions to provide multidirectional measurements. The low-noise, thermally-stable nature of silicon carbide and its radiation tolerance allows the multidirectional array of detector stacks to be packed in a 6U CubeSat without active cooling. A concept involving additional coincidence/anticoincidence detectors and a high energy Cherenkov detector is possible to further expand ion energy range and sensitivity.

Extraterrestrial Radiation↗

Blocked impurity band hybrid infrared focal plane arrays for astronomy

High-performance infrared hybrid focal plane arrays using 10- x 50-element Si:As blocked-impurity-band (BIB) detectors (cutoff wavelength = 28 microns) and matching switched MOSFET multiplexers have been developed and characterized for space astronomy. Use of impurity-band-conduction technology provides detectors which are nuclear-radiation-hard and free of the many anomalies associated with conventional silicon photoconductive detectors. Emphasis in the present work is on recent advances in detector material quality which have led to significantly improved detector and hybrid characteristics. Results demonstrating increased quantum efficiency (particularly at short-wavelength infrared), obtained by varying the BIB detector properties (infrared active layer thickness and arsenic doping profile), are summarized. Measured read noise and dark current for different temperatures are reported. The hybrid array performance achieved demonstrates that BIB detectors are well suited for use in astronomical instrumentation.

Reynolds, D. B.↗

Cryogenic telescope on the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has completed an unbiased all-sky survey at wavelengths from 10 to 100 microns. The design and performance of the focal plane array is described with emphasis on in-orbit measurements of the sensitivity and stability. In the four broad spectral bands centered at 12, 25, 60, and 100 microns, the system noise equivalent flux density (NEFD) values are in Jy/(Square root of Hz), 0.03, 0.025, 0.046, and 0.21, respectively (Jansky = 10 to the -26th W/sq m/Hz). For point sources, a single scan at the survey rate of 3.8 arcmin/s yields limiting flux densities at the 3-sigma confidence level of 0.36, 0.30, 0.39, and 1.2 Jy. The dc stability of the junction field effect transistor (JFET) amplifiers and the excellent off-axis rejection of the telescope permit total flux measurements of extended infrared emission at levels below 6,000,000 Jy/sr. Response of the extrinsic silicon and germanium photo-detectors to ionizing radiation is described.

Low, F. J.↗