Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Deposition and characterization of α-Fe 2 O 3 /Pd thin films for neutron reflectometry studies

Here, we report deposition of hematite/Pd thin films on silicon wafers via radio frequency (RF) magnetron sputtering and subsequent characterization for future in situ neutron reflectometry studies. Following deposition, the hematite/Pd thin films were characterized as prepared and after annealing in air for 2h at 400, 500, and 600 °C, respectively. Raman spectroscopy, grazing incidence x-ray diffraction, and neutron reflectometry (NR) were used to characterize the structure and chemical compositions of the thin films. The results indicate that pure α-Fe 2 O 3 (hematite) films were produced, free from other iron oxide phases and impurities. NR data reveal that one intermediate layer between the Pd layer and the hematite layer was formed during sputtering deposition processes. The fitted scattering length density (SLD) of the as-deposited hematite layer is 70% of the theoretical SLD value, indicating that the grains are loosely packed in the RF-deposited hematite films. After annealing at elevated temperatures, the hematite films show increased SLD values but remain comparable to that of preannealed.

36 MATERIALS SCIENCE↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

Experimental Study of Supercooled Large Droplet Impingement Effects

Typically, ice accretion results from small supercooled droplets (droplets cooled below freezing), usually 5 to 50 microns in diameter, which can freeze upon impact with an aircraft surface. Recently, ice accretions resulting from supercooled large droplet (SLD) conditions have become a safety concern. Current ice accretion codes have been extensively tested for Title 14 Code of Federal Regulations Part 25, Appendix C icing conditions but have not been validated for SLD icing conditions. This report presents experimental methods for investigating large droplet impingement dynamics and for obtaining small and large water droplet impingement data.

ICE ACCRETION CODE↗

Combined, time-resolved, in situ neutron reflectometry and X-ray diffraction analysis of dynamic SEI formation during electrochemical N 2 reduction

One means of improving performance for electrochemical ammonia production through the Li-mediated N 2 reduction reaction (Li-NRR) is by cycling the current driving the reaction between open-circuit conditions and periods of applied current density. Herein, we have investigated the dynamics of the electrode–electrolyte interface under Li-NRR conditions during current cycling using in situ time-resolved neutron reflectometry and grazing-incidence synchrotron X-ray diffraction. During cycling, measured neutron reflectivity curves indicated bilayer formation in which Li-containing species such as LiOH, Li 2 O, and small quantities of Li 3 N and metallic Li primarily appeared in a thin layer at the cathode surface, above which formed a much larger, porous, ‘solid–electrolyte interface’ (SEI) layer. Upon return to open-circuit conditions, Li-containing species quickly moved out of the thin layer, leaving a compact, stable layer of decomposition products underneath the SEI layer. This SEI layer concomitantly filled with electrolyte or dissolved, becoming indistinguishable from the electrolyte via contrast in scattering-length density (SLD). During the second current cycle, Li-containing species again preferentially deposited directly atop the cathode, with the thick SEI-like layer again appearing within a minute. This SEI layer exhibited a lower SLD more quickly than in the first cycle, which might suggest that Li-containing species become distributed within the porous SEI layer. Furthermore, these time-resolved observations of SEI and plated layers during current cycling suggest that benefits associated with return to open-circuit conditions between periods of applied current density may be related to the concomitant loss of Li-containing species from a thin layer at the cathode surface into a porous SEI layer that becomes filled with electrolyte or dissolves.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Superluminescent Diodes for Smart Lighting Systems. Final Report

The solid-state lighting ecosystem has evolved very rapidly over the last few years, with significant improvements in the technical performance of light-emitting diodes (LEDs) and the commoditization of LED-based lighting fixtures. As the performance of conventional lighting products begins to saturate, there is growing market interest in “Lighting as a Service” applications that will leverage advanced systems to impart new functionalities to lighting and improve energy efficiency, human health, and productivity. These “Smart Lighting” systems will include high-performance light sources, specialized sensors, and dynamic controls to deliver high quality, energy efficient, color tunable lighting with customized spatial light delivery and integrated visible light communication capability. To achieve these capabilities, smart lighting systems will place greater demands on the performance of light sources. Highly efficient sources with additional functionalities compared to conventional LEDs, such as small form factor, large modulation bandwidth, and spatially coherent output beams, will be required. While laser diodes have been proposed as potential sources for smart lighting systems, they also exhibit several properties that pose challenges, such as temporal coherence, extremely high spatial coherence, and ultra-narrow linewidths. To address these issues, we propose an investigation of an alternative device architecture known as a superluminescent diode (SLD). SLDs are similar in form to ridge laser diodes and share many of the same characteristics, such as stimulated emission operation, spatially coherent output, small form factor, and the potential for large modulation bandwidth. However, the operating principle for SLDs is distinct from laser diodes in that SLDs lack a strong cavity feedback mechanism, resulting in spatially coherent but temporally incoherent light output. Thus, SLDs may address the issues with laser diodes for lighting, while simultaneously maintaining some of the desirable characteristics of both laser diodes and LEDs. The objectives of this proposal are to design, grow, and fabricate blue (450 nm) SLDs on polar c-plane and nonpolar m-plane free-standing GaN substrates, and to evaluate their potential as sources in smart lighting systems through basic device characterization and detailed investigations of their efficiency droop and modulation bandwidth. The primary scientific aims of this work are to understand the fundamental role of optical gain in the superluminescent (non-lasing) regime on efficiency droop and modulation bandwidth in III-nitride emitters and to understand the effects of higher optical gain on SLD performance by comparing polar c-plane and nonpolar m-plane SLDs. The University of New Mexico (UNM) will collaborate with Sandia National Laboratories (SNL) and the Center for Integrated Nanotechnologies to design, fabricate, grow, and characterize the SLDs. UNM will perform the design and epitaxial growth, while SNL will focus on the fabrication and device characterization. The novelty of the proposed work includes the first comprehensive theoretical and experimental investigations of efficiency droop and the first investigation of modulation bandwidth in GaN-based emitters operating in the superluminescent regime. Moreover, the comparison of c-plane and m-plane SLDs will enable the first analysis of the effects of higher optical gain on the device performance. The development of high-performance GaN-based SLDs may enable efficiency gains and improved functionality in next-generation smart lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase Doppler Interferometry for Efficient Cloud Drop Size Distribution, Number Density, and LWC Measurements

Threats to aviation safety as a result of super-cooled large drops (SLD) has been addressed by the FAA rules change (14 CFR Part 25) with the additional icing certification requirement. SLD clouds often consist of bi-modal drop size spectra leading to significant problems in simulating and characterizing these conditions in situ and in icing wind tunnels. Legacy instrumentation for measuring drop size distributions and liquid water content are challenged under these conditions. The large size range measurement problem is addressed with the development of the Phase Doppler Interferometer, Flight Probe Dual-Range (PDI FPDR). The method is described in this report along with the measurement capabilities including the dynamic measurement range and overall working size range. The PDI instrument bases drop size measurements on the light wavelength as the measurement length scale. The light wavelength is a much more robust scale, especially as compared to the light scattering intensity. Additionally, methods for accurately characterizing the sample volume in situ based on measured drop velocity and transit time are reviewed, given the importance of this parameter for merging results and measuring LWC. Droplet coincidence in the sample volume can be problematic so this condition is treated with an innovative signal parsing approach. Measurement examples acquired in the NASA IRT are provided. Measurements of LWC showed good agreement with the Artium Particle Imaging (PI) instrument but diverged from the tunnel calibration results for larger MVD values.

42 ENGINEERING↗

NASA/FAA/NCAR Supercooled Large Droplet Icing Flight Research: Summary of Winter 1996-1997 Flight Operations

During the winter of 1996-1997, a flight research program was conducted at the NASA-Lewis Research Center to study the characteristics of Supercooled Large Droplets (SLD) within the Great Lakes region. This flight program was a joint effort between the National Aeronautics and Space Administration (NASA), the National Center for Atmospheric Research (NCAR), and the Federal Aviation Administration (FAA). Based on weather forecasts and real-time in-flight guidance provided by NCAR, the NASA-Lewis Icing Research Aircraft was flown to locations where conditions were believed to be conducive to the formation of Supercooled Large Droplets aloft. Onboard instrumentation was then used to record meteorological, ice accretion, and aero-performance characteristics encountered during the flight. A total of 29 icing research flights were conducted, during which "conventional" small droplet icing, SLD, and mixed phase conditions were encountered aloft. This paper will describe how flight operations were conducted, provide an operational summary of the flights, present selected experimental results from one typical research flight, and conclude with practical "lessons learned" from this first year of operation.

Miller, Dean↗

Subject Load-Harness Interaction During Zero-Gravity Treadmill Exercise

When astronauts exercise on orbit, a subject load device (SLD) must be used to return the subject back to the supporting surface. The load in the SLD needs to be transferred the body by a harness which typically distributes this load between the pelvis and We shoulders. Through the use of a zero-gravity simulator, this research compared subject comfort and ground reaction forces during treadmill running at three levels of subject load (60%,80%, and 100% of body weight) in two harness designs ("shoulder only" and "waist "and shoulder ").

McCrory, Jean L.↗

Locomotion in simulated microgravity: gravity replacement loads

BACKGROUND: When an astronaut walks or runs on a treadmill in microgravity, a subject load device (SLD) is used to return him or her back to the treadmill belt. The gravity replacement load (GRL) in the SLD is transferred, via a harness, to the pelvis and/or the shoulders. This research compared comfort and ground reaction forces during treadmill running in a microgravity locomotion simulator at GRLs of 60%, 80%, and 100% of body weight (BW). Two harness designs (shoulder springs only (SSO) and waist and shoulder springs (WSS)) were used. HYPOTHESES: 1) The 100% BW gravity replacement load conditions would be comfortably tolerated and would result in larger ground reaction forces and loading rates than the lower load conditions, and 2) the WSS harness would be more comfortable than the SSO harness. METHODS: Using the Penn State Zero Gravity Locomotion Simulator (ZLS), 8 subjects ran at 2.0 m x s(-1) (4.5 mph) for 3 min at each GRL setting in each harness. Subjective ratings of harness comfort, ground reaction forces, and GRL data were collected during the final minute of exercise. RESULTS: The 100% BW loading conditions were comfortably tolerated (2.3 on a scale of 0-10), although discomfort increased as the GRL increased. There were no overall differences in perceived comfort between the two harnesses. The loading rates (27.1, 33.8, 39.1 BW x s(-1)) and the magnitudes of the first (1.0, 1.4, 1.6 BW) and second (1.3, 1.7, 1.9 BW) peaks of the ground reaction force increased with increasing levels (60, 80, 100% BW respectively) of GRL. CONCLUSIONS: Subjects were able to tolerate a GRL of 100% BW well. The magnitude of the ground reaction force peaks and the loading rate is directly related to the magnitude of the GRL.

NASA Discipline Musculoskeletal↗

Additional Study of Water Droplet Median Volume Diameter (MVD) Effects on Ice Shapes

This paper reports the result of an experimental study in the NASA Glenn Icing Research Tunnel (IRT) to evaluate how well the MVD-independent effect identified previously might apply to SLD conditions in rime icing situations. Models were NACA 0012 wing sections with chords of 53.3 and 91.4 cm. Tests were conducted with a nominal airspeed of 77 m/s (150 kt) and a number of MVD's ranging from 15 to 100 m with LWC of 0.5 to 1 g/cu m. In the present study, ice shapes recorded from past studies and recent results at SLD and Appendix-C conditions are reviewed to show that droplet diameter is not important to rime ice shape for MVD of 30 microns or larger, but for less than 30 m drop sizes a rime ice shape transition from convex to wedge to spearhead type ice shape is observed.

Tsao, Jen-Ching↗

A Database of Supercooled Large Droplet Ice Accretions [Supplement]

A unique, publicly available database regarding supercooled large droplet (SLD) ice accretions has been developed in NASA Glenn's Icing Research Tunnel. Identical cloud and flight conditions were generated for five different airfoil models. The models chosen represent a variety of aircraft types from the horizontal stabilizer of a large transport aircraft to the wings of regional, business, and general aviation aircraft. In addition to the standard documentation methods of 2D ice shape tracing and imagery, ice mass measurements were also taken. This database will also be used to validate and verify the extension of the ice accretion code, LEWICE, into the SLD realm.

VanZante, Judith Foss↗

Providing Internet Access to High-Resolution Lunar Images

The OnMoon server is a computer program that provides Internet access to high-resolution Lunar images, maps, and elevation data, all suitable for use in geographical information system (GIS) software for generating images, maps, and computational models of the Moon. The OnMoon server implements the Open Geospatial Consortium (OGC) Web Map Service (WMS) server protocol and supports Moon-specific extensions. Unlike other Internet map servers that provide Lunar data using an Earth coordinate system, the OnMoon server supports encoding of data in Moon-specific coordinate systems. The OnMoon server offers access to most of the available high-resolution Lunar image and elevation data. This server can generate image and map files in the tagged image file format (TIFF) or the Joint Photographic Experts Group (JPEG), 8- or 16-bit Portable Network Graphics (PNG), or Keyhole Markup Language (KML) format. Image control is provided by use of the OGC Style Layer Descriptor (SLD) protocol. Full-precision spectral arithmetic processing is also available, by use of a custom SLD extension. This server can dynamically add shaded relief based on the Lunar elevation to any image layer. This server also implements tiled WMS protocol and super-overlay KML for high-performance client application programs.

Plesea, Lucian↗

Comparison of Aircraft Icing Growth Assessment Software

A research project is underway to produce computer software that can accurately predict ice growth under any meteorological conditions for any aircraft surface. An extensive comparison of the results in a quantifiable manner against the database of ice shapes that have been generated in the NASA Glenn Icing Research Tunnel (IRT) has been performed, including additional data taken to extend the database in the Super-cooled Large Drop (SLD) regime. The project shows the differences in ice shape between LEWICE 3.2.2, GlennICE, and experimental data. The project addresses the validation of the software against a recent set of ice-shape data in the SLD regime. This validation effort mirrors a similar effort undertaken for previous validations of LEWICE. Those reports quantified the ice accretion prediction capabilities of the LEWICE software. Several ice geometry features were proposed for comparing ice shapes in a quantitative manner. The resulting analysis showed that LEWICE compared well to the available experimental data.

Wright, William↗

Super Cooled Large Droplet Analysis of Several Geometries Using LEWICE3D Version 3

Super Cooled Large Droplet (SLD) collection efficiency calculations were performed for several geometries using the LEWICE3D Version 3 software. The computations were performed using the NASA Glenn Research Center SLD splashing model which has been incorporated into the LEWICE3D Version 3 software. Comparisons to experiment were made where available. The geometries included two straight wings, a swept 64A008 wing tip, two high lift geometries, and the generic commercial transport DLR-F4 wing body configuration. In general the LEWICE3D Version 3 computations compared well with the 2D LEWICE 3.2.2 results and with experimental data where available.

Bidwell, Colin S.↗

Comparison of Bimodal Ice Shapes on Full-Chord and Hybrid CRM Midspan Models

An ice shape database has been created to document ice accretions on a full-chord length and hybrid versions of a 65 percent scale size of the mid-span section of the Common Research Model resulting from an exposure to a Super-cooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each ice accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from monomodal distributions of identical cloud droplet Median Volume Diameter (MVD) were obtained and compared. Results indicated that the ice shapes resulting from the monomodal and bimodal drop size distributions have similar 2D Maximum Combined Cross Section, or MCCS, ice shape around the model leading edge region and equivalent ice mass measurement per unit span to within the IRT SLD cloud calibration uncertainty, as expected with this approach, but the bimodal distributions have distinctly larger ice feathers that extended further back on the chord of the model. For most test conditions, the overall size and shape of the main ice accretions compared well between the full-chord and hybrid models.

Icing↗

Comparison of Bimodal Ice Shapes on Full-Chord and Hybrid CRM Midspan Models

An ice shape database has been created to document ice accretions on a full-chord length and hybrid versions of a 65 percent scale size of the mid-span section of the Common Research Model resulting from an exposure to a Super-cooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each ice accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from monomodal distributions of identical cloud droplet Median Volume Diameter (MVD) were obtained and compared. Results indicated that the ice shapes resulting from the monomodal and bimodal drop size distributions have similar 2D Maximum Combined Cross Section, or MCCS, ice shape around the model leading edge region and equivalent ice mass measurement per unit span to within the IRT SLD cloud calibration uncertainty, as expected with this approach, but the bimodal distributions have distinctly larger ice feathers that extended further back on the chord of the model. For most test conditions, the overall size and shape of the main ice accretions compared well between the full-chord and hybrid models

Icing , Simulation, Validation↗

Comparison of Bimodal Ice Shapes on Full-Chord and Hybrid CRM Midspan Models

An ice shape database has been created to document ice accretions on a full-chord length and hybrid versions of a 65 percent scale size of the mid-span section of the Common Research Model resulting from an exposure to a Super-cooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each ice accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from monomodal distributions of identical cloud droplet Median Volume Diameter (MVD) were obtained and compared. Results indicated that the ice shapes resulting from the monomodal and bimodal drop size distributions have similar 2D Maximum Combined Cross Section, or MCCS, ice shape around the model leading edge region and equivalent ice mass measurement per unit span to within the IRT SLD cloud calibration uncertainty, as expected with this approach, but the bimodal distributions have distinctly larger ice feathers that extended further back on the chord of the model. For most test conditions, the overall size and shape of the main ice accretions compared well between the full-chord and hybrid models.

Icing↗

A Preliminary Study of Inter-Facility LWC Differences in Appendix C and Supercooled Large Droplet Conditions due to Calibration Instruments

The simulation of clouds containing Supercooled Large Droplets has received increasing attention due to the introduction of Appendix O and future associated requirements for means of compliance. Supercooled Large Droplet conditions can cover four orders of magnitude in drop sizes, imposing a larger instrument measurement challenge than for Appendix C conditions. Wind tunnel facilities have adopted different instrumentation for liquid water content measurement, with fundamentally different principles of operation. In order to explore the comparability of the different instruments used for Appendix C and SLD measurement, and its impact on confidence in measurements used for means of compliance, a project was established to conduct a series of dedicated tests at three wind tunnel facilities. To date, liquid water content measurements have been completed using a Multi-Element sensor as the common instrument at two of the facilities. The data have provided preliminary information suggesting that substantial inter-facility differences likely exist in liquid water content estimates in Supercooled Large Droplet conditions that appear to be largely attributable to the choice of calibration instruments. These results are dependent on the assumption that the Multi-Element probe would produce equivalent measurements at the two facilities if the liquid water content were the same, regardless of other environmental differences that may exist between the two facilities. Planned further testing with other liquid water content measurement techniques may provide further information to confirm or refute the results of this study.

aircraft icing↗