Search NASA⌕ Search

SEARCH · Search NASA

Results for “SMACs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flight vehicle propellant surface motion by numerical method

The marker and cell technique is applied to three idealized hydrodynamic situations of interest to the Space Shuttle External Tank (ET). These applications illustrate the versatility of this technique as well as its usefulness in solving similar problems in the aerospace industry. The codes used are the simplified marker and cell (SMAC) code and the variable grid simplified marker and cell code named ERIE. The examples focus on the dropout height in the LH2 tank, the slosh behavior of propellant in the bottom dome of the ET during thrust termination, both of which are required to accurately determine the amount of usable propellants, and the effect on liquid surface due to LO2 tank wall motions occurring during Space Shuttle lift-off. Comparisons with experimental results and linear theory are also presented.

Mehta, G.↗

Toxicological safeguards in the manned Mars missions

Safeguards against toxic chemical exposures during manned Mars missions (MMMs) will be important for the maintenance of crew health and the accomplishment of mission objectives. Potential sources include offgassing, thermodegradation or combustion of materials, metabolic products of crew members, and escape of chemical from containment. Spacecraft maximum allowable concentration (SMAC) limits will have to be established for potential contaminants during the MMMs. The following factors will be used in establishing these limits: duration of mission, simultaneous exposure to other contaminants, deconditioning of crew members after long periods of reduced gravity, and simultaneous exposure to ionizing radiation. Atmospheric contaminant levels in all compartments of the transit spacecraft and Manned Mars Station (MMS) will be monitored at frequent intervals with a real time analyzer. This analyzer will be highly automated, requiring minimal crew time and expertise. The atmospheric analyzer will find other usages during the MMMs such as analyzing Martian atmospheres and soils, exhaled breath and body fluids of crew members, and reaction products in chemical processing facilities.

Coleman, Martin E.↗

Human exposure limits to hypergolic fuels

Over the past four decades, many studies have been conducted on the toxicities of the rocket propellants hydrazine (HZ) and monomethylhydrazine (MH). Numerous technical challenges have made it difficult to unambiguously interpret the results of these studies, and there is considerable divergence between results obtained by different investigators on the inhalation concentrations (MAC's) for each toxic effect inducible by exposure to hypergolic fuels in spacecraft atmospheres, NASA undertook a critical review of published and unpublished investigations on the toxicities of these compounds. The current state of the art practices for similar studies. While many questions remain unanswered, MAC's were determined using the best available data for a variety of toxic endpoints for potential continuous exposure durations ranging from 1 hour to 180 days. Spacecraft MAC's (SMAC's) were set for each compound based on the most sensitive toxic endpoint at each exposure duration.

Garcia, H. D.↗

Airborne trace organic contaminant removal using thermally regenerable multi-media layered sorbents

A cyclic two-step process is described which forms the basis for a simple and highly efficient air purification technology. Low molecular weight organic vapors are removed from contaminated airstreams by passage through an optimized sequence of sorbent media layers. The contaminant loaded sorbents are subsequently regenerated by thermal desorption into a low volume inert gas environment. A mixture of airborne organic contaminants consisting of acetone, 2-butanone, ethyl acetate, Freon-113 and methyl chloroform has been quantitatively removed from breathing quality air using this technique. The airborne concentrations of all contaminants have been reduced from initial Spacecraft Maximum Allowable Concentration (SMAC) levels to below the analytical limits of detection. No change in sorption efficiency was observed through multiple cycles of contaminant loading and sorbent regeneration via thermal desorption.

Atwater, James E.↗

Guidelines for developing spacecraft maximum allowable concentrations for Space Station contaminants

The National Aeronautics and Space Administration (NASA) is preparing to launch a manned space station by the year 1996. Because of concerns about the health, safety, and functioning abilities of the crews, NASA has requested that the National Research Council (NRC) through the Board on Environmental Studies and Toxicology (BEST) provide advice on toxicological matters for the space-station program. The Subcommittee on Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants was established by the Committee on Toxicology (COT) to address NASA's concerns. Spacecraft maximum allowable concentrations (SMAC's) are defined as the maximum concentrations of airborne substances (such as gas, vapor, or aerosol) that will not cause adverse health effects, significant discomfort, or degradation in crew performance.

Source record↗

Four-Dimensional Oceanic and Atmosperic Data Assimilation with Tropical Rainfall Measuring Mission Data

An oceanic data assimilation system which allows to utilize the forthcoming Tropical Rainfall Measuring Mission (TRMM) data has been developed and applied to the Pacific Ocean to produce the velocity field. The assimilated data will be indispensable to examine the effects of rainfall and its variability on the structure and circulation of the tropical oceans and to assess the impact of global warming due to the increase of carbon dioxide on the ocean circulation system and the marine pollution caused by oil spill and ocean damping of radionuclide. The data will also provide the verification for the oceanic and ocean-atmosphere coupled General Circulation Models (GCM's). The system consists of oceanic GCM, analysis scheme and data. In the system the flow field has been determined to be physically consistent with the observed density field and the sea surface winds derived from the Special Sensor Microwave Imagery (SSM/I) data which drive the ocean current. The time integration has been performed for five years until the flow field near the surface attained the steady state starting from the rest ocean with observed temperature and salinity fields, and the SSM/I surface wind velocity. The resultant flow field showed high producibility of the system. Especially the flow near the ocean surface agreed well with available observed data. The system, for the first time, succeeded to produce the eastward subtropical current which has been discovered in the joint investigation on Kuroshio current (CSK) in the 1960s. To verify the quality of the flow field a trajectory analysis has been carried out and compared with the Algos buoy data. BRIEF DESCRIPTION OF THE DATA ASSIMILATION SYSTEM ## Oceanic GCM and analysis scheme--The basic equations are much the same as used for the GCM's, except for the Newtonian damping terms introduced into the prediction equations for the potential temperature and salinity to maintain these fields as observed. The C grid of 2'lat. by 2'long. in horizontal and the 11 vertical levels are applied to the entire Pacific Ocean. At the east and west ocean boundaries the periodic boundary conditions are applied creating fictitious ocean there. The SMAC Method is used to increase the accuracy of mass conservation. * Data--The JODC temperature and salinity data obtained from 1906 to 1988 are used in the system between Long.100'E. and 60'W. The surface wind data are derived from the SSM/I data by Dr-R. Atlas of NASA/GSFC. The data set contains every 6 hours data from July 1987 to June 1989 on the grid of 2'lat. by 2.5'long. The averaged for the whole period and then interpolated into the 2'lat. by 2'long. grid data are used to force the system. The sea bottom topography data was based on the General Bathymetric Chart of the Ocean (GEBCO) supplied by the Canadian Hydrographic Service under contract with the International Hydrographic Organization and International Oceanographic Commission of UNESCO.

Takano, Kenji↗

Volatiles Evolved from Soybean Products Intended for Use in Long Duration Space Missions

Soybeans have been baselined to be grown in a habitat (Advanced Life Support Systems Integration Test Bed, ALSSITB) intended for evaluating advanced life support systems developed for long duration missions to the Moon or Mars. The ALSSITB is being constructed at NASA-Johnson Space Center and is composed of 5 chambers (4.6 m x 11.3 m each) and an airlock joined by an interconnecting tunnel (3.7 m x 19.2 m). Processed soy products such as soy milk and soy bread are planned to be incorporated into a nutritionally sound, plant-based food system. Since all consumables will be recycled and reused, volatile compounds evolved during the manufacturing of these food products need to be quantified to assess their impact on this closed loop system. Soy milk was made in a prototype machine and bread in a commercial bread baking machine. These machines were each placed in a tightly closed chamber and, at the completion of the process, air volatiles were identified and quantified by GC/MS. For soy milk, ethanol, acetaldehyde, methanol, hexanal, propanal and acetone and for soybread, acetaldehyde, ethanol, N-propanol and ethyl acetate were detected in significant quantities. The crew members will spend an average of 180 days in the ALSSITB and it was estimated that 138 batches of soy milk will be processed in the tunnel and 130 loaves of soybread would be baked in the habitat chamber during their stay. The aforementioned volatiles would surpass the 180 day Spacecraft Maximum Allowable Concentrations (SMACs) if no means of scrubbing are adapted which would lead to toxic levels of these compounds. Therefore, sufficient means for eliminating the contribution of volatiles evolved from food processing and preparation equipment needs to be provided in the ALSSITB.

Vodovotz, Yael↗

The Role of Toxicity Testing in NASA's Future Missions

NASA has deemed it necessary to perform the Toxicity Test (offgassing of toxic products) on all non-metallic materials proposed for use in habitable environments onboard the Shuttle and International Space Station flS,!J. This requirement stems from the desire to maintain a healthy, breathable atmosphere for the astronauts. As Shuttle missions have lengthened and with the habitation of the International Space Station, the need for understanding and controlling the contaminants in breathable atmospheres has increased. The increased duration of humans in space present two concerns to the astronauts with regard to their breathing air: 1. Breathing the on-board air. 2. Improved cleaning/filtering of existing air. Trends using existing toxicity data for materials and an understanding of the air cleaning/filtering capabilities in relation to Spacecraft Maximum Allowable Concentrations (SMAC) of offgassed components are explored. Recommendations are made for materials selection practices that should be followed to ensure a safe and healthy breathing environment for astronauts aboard these long term projects. The importance and relevance of Toxicity testing and materials selection in conjunction with the new NASA missions of creating a human presence on the Moon and traveling to Mars are described.

Whitfield, Steve↗

Quasi Real Time Data Analysis for Air Quality Monitoring with an Electronic Nose

Cabin Air Quality Monitoring: A) Functions; 1) Incident monitor for targeted contaminants exceeding targeted concentrations. Identify and quantify. 2) Monitor for presence of compounds associated with fires or overheating electronics. 3) Monitor clean-up process. B) Characteristics; 1) Low mass, low power device. 2) Requires little crew time for maintenance and calibration. 3) Detects, identifies and quantifies selected chemical species at or below 24 hour SMAC.

data analysis↗

STS-113/11A: Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned in December 2002 and in May 2003 aboard Soyuz 5

The toxicological assessments of grab sample canisters (GSCs) returned aboard STS-l13 and Soyuz 5 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 79-120% except as noted in the table. One sample was returned with the valve opened. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) has leaked from heat-exchange units in large quantities, so its concentration is tracked separately. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. The table shows that the air quality in general was acceptable for crew respiration through the middle of December 2002. No conclusions can be made about the air quality after that date due to NASA's inability to return air samples from the ISS . Alcohols are not being controlled to the recently lowered guideline of 5 mg/m3, which was recommended to protect the water recovery systems. The airlock sample was taken during the regeneration of Met ox canisters in the adjacent Node. The trace pollutants were not increased above background; however, inspection of table 1 in the appendix shows a CO2 concentration of 17,000 mg/cu m, which is a relatively high concentration, but still below the 24-hour SMAC of23,000 mg/cu m. The control of OFP continues to be adequate at least through December 2002. Formaldehyde concentrations suggest that the high levels that were being found in the Lab atmosphere have subsided. This is probably attributable to the restoration of IMV in early February 2003 . Before the obstructing material was removed from ducts the Lab formaldehyde concentrations approached 0.06 mg/cu m, whereas after the repair the levels were near 0.04 mg/m3 . This does not mean that local sources in the Lab have been reduced, only that the excess of formaldehyde produced in the Lab is distributed into the whole volume of the ISS.

James, John T.↗

STS 134, 135 and 26S Return Samples: Air Quality aboard Shuttle (STS-134) and International Space Station

This is a very limited set of samples on which to perform an air quality assessment. However, based on these samples, we have no reason to believe that nominal ISS air is unsafe to breathe. We must continue to be vigilant when dealing with nominal atmospheres in ISS. New, unmanned modules require special attention when the crew first enters. Carbon Monoxide Accumulation aboard ISS: Beginning in late 2008 the nominal concentrations of CO began increasing gradually (Figure 1). The results from samples returned on this flight indicate that the CO concentrations, after dropping in late 2009, have cycled upward and then settled back to concentrations near 2 mg/m3. In any case, these changes are well below the 180-day SMAC for CO, which is17 mg/m3. There is no threat to crew health. Carbon Dioxide: This anthropogenic compound has drawn much attention recently because of the possibility that it could contribute to the effects of intracranial hypertension experienced because of spaceflight-induced fluid shifts. From now on we will maintain a plot (Figure 2) of carbon dioxide concentrations ( SD) by averaging the values found in the 3-5 mini-GSC samples taken each month in diverse locations of the ISS. This will enable us to estimate the average exposure of crewmembers to carbon dioxide during their stay aboard the ISS. In general, concentrations are being maintained below 3.5 mmHg. Figure 1

James, John T.↗

Modeling Geometric Arrangements of TiO2-Based Catalyst Substrates and Isotropic Light Sources to Enhance the Efficiency of a Photocatalystic Oxidation (PCO) Reactor

The closed confined environments of the ISS, as well as in future spacecraft for exploration beyond LEO, provide many challenges to crew health. One such challenge is the availability of a robust, energy efficient, and re-generable air revitalization system that controls trace volatile organic contaminants (VOCs) to levels below a specified spacecraft maximum allowable concentration (SMAC). Photocatalytic oxidation (PCO), which is capable of mineralizing VOCs at room temperature and of accommodating a high volumetric flow, is being evaluated as an alternative trace contaminant control technology. In an architecture of a combined air and water management system, placing a PCO unit before a condensing heat exchanger for humidity control will greatly reduce the organic load into the humidity condensate loop ofthe water processing assembly (WPA) thereby enhancing the life cycle economics ofthe WPA. This targeted application dictates a single pass efficiency of greater than 90% for polar VOCs. ~ Although this target was met in laboratory bench-scaled reactors, no commercial or SBIR-developed prototype PCO units examined to date have achieved this goal. Furthermore, the formation of partial oxidation products (e.g., acetaldehyde) was not eliminated. It is known that single pass efficiency and partial oxidation are strongly dependent upon the contact time and catalyst illumination, hence the requirement for an efficient reactor design. The objective of this study is to maximize the apparent contact time and illuminated catalyst surface area at a given reactor volume and volumetric flow. In this study, a Ti02-based photocatalyst is assumed to be immobilized on porous substrate panels and illumination derived from linear isotropic light sources. Mathematical modeling using computational fluid dynamics (CFD) analyses were performed to investigate the effect of: 1) the geometry and configuration of catalyst-coated substrate panels, 2) porosity of the supporting substrate, and 3) varying the light source and spacing on contact time and illuminated catalyst area.

Richards, Jeffrey T.↗

Shocking Results on the Adverse Effects of CO2 Exposures

Carbon dioxide (CO2) is released in large quantities from humans while they live and work in spacecraft or work outside the spacecraft during extravehicular activity (EVA). Removal of this anthropogenic pollutant requires major resources, and these resources increase dramatically as the levels of CO2 set to protect human health and performance are reduced. The current Spacecraft Maximum Allowable Concentration of CO2 aboard the ISS is 0.7% or 5.3 mmHg; however, according to Chits (mission action requests), NASA and its international partners have agreed to control CO2 levels to less than 4 mmHg. In the meantime, retrospective investigations attempting to associate crew symptoms with elevated CO2 levels over the life if the International Space Station (ISS) are underway to determine if this level is sufficient to protect against health and performance decrements. Anecdotal reports suggest that crewmembers are not able to perform complex tasks as readily in spaceflight as they were able during ground-based training. While physiological effects of CO2 have been studied for many decades, it is only recently that the effects of CO2 on higher reasoning capabilities have been studied. The initial results are shocking. For example, one study published in the respected journal Environmental Health Perspectives showed obvious adverse effects of CO2 exposures on higher reasoning at 1.9 mmHg. The implications and limitations of this study are paramount in determining future CO2 SMACs for human spaceflight, both aboard the ISS and in exploration-class missions. Key Words: carbon dioxide, spacecraft, air quality, toxic effects

James, John T.↗

An Assessment of Environmental Health Needs

Environmental health fundamentally addresses the physical, chemical, and biological risks external to the human body that can impact the health of a person by assessing and controlling these risks in order to generate and maintain a health-supportive environment. In manned spacecraft, environmental health risks are mitigated by a multi-disciplinary effort, employing several measures including active and passive controls, by establishing environmental standards (SMACs, SWEGs, microbial and acoustics limits), and through environmental monitoring. Human Health and Performance (HHP) scientists and Environmental Control and Life Support (ECLS) engineers consider environmental monitoring a vital component to an environmental health management strategy for maintaining a healthy crew and achieving mission success. ECLS engineers use environmental monitoring data to monitor and confirm the health of ECLS systems, whereas HHP scientists use the data to manage the health of the human system. Because risks can vary between missions and change over time, environmental monitoring is critical. Crew health risks associated with the environment were reviewed by agency experts with the goal of determining risk-based environmental monitoring needs for future NASA manned missions. Once determined, gaps in environmental health knowledge and technology, required to address those risks, were identified for various types of exploration missions. This agency-wide assessment of environmental health needs will help guide the activities/hardware development efforts to close those gaps and advance the knowledge required to meet NASA manned space exploration objectives. Details of the roadmap development and findings are presented in this paper.

Macatangay, Ariel V.↗

Toxicological Assessment of ISS Air Quality: April - May 2013

A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.

Meyers, Valerie↗

An Assessment of Environmental Health Needs for Manned Spacecraft

Environmental health fundamentally addresses the physical, chemical, and biological risks external to the human body that can impact the health of a person by assessing and controlling these risks in order to generate and maintain a health‐supportive environment. Environmental monitoring coupled with other measures including active and passive controls and the implementation of environmental standards (SMACs, SWEGs, microbial and acoustics limits) are used to ensure environmental health in manned spacecraft. NASA scientists and engineers consider environmental monitoring a vital component to an environmental health management strategy for maintaining a healthy crew and achieving mission success. Environmental monitoring data confirms the health of ECLS systems, in addition to contributing to the management of the health of human systems. Crew health risks associated with the environment were reviewed by agency experts with the goal of determining risk-based environmental monitoring needs for future NASA manned missions. Once determined, gaps in knowledge and technology, required to address those risks, were identified for various types of Exploration missions. This agency‐wide assessment of environmental health needs will help guide the activities/hardware development efforts to close those gaps and advance the knowledge required to meet NASA manned space exploration objectives. Details of this assessment and findings are presented in this paper.

Macatangay, Ariel V.↗

Protecting Astronaut Health at First Entry into Vehicles Visiting the international Space Station: Insights from Whole-Module Offgas Testing

NASA has accumulated considerable experience in offgas testing of whole modules prior to their docking with the International Space Station (ISS). Since 1998, the Space Toxicology Office has performed offgas testing of the Lab module, both MPLM modules, US Airlock, Node 1, Node 2, Node 3, ATV1, HTV1, and three commercial vehicles. The goal of these tests is twofold: first, to protect the crew from adverse health effects of accumulated volatile pollutants when they first enter the module on orbit, and secondly, to determine the additional pollutant load that the ISS air revitalization systems must handle. In order to predict the amount of accumulated pollutants, the module is sealed for at least 1/5th the worst‐case time interval that could occur between the last clean air purge and final hatch closure on the ground and the crew's first entry on orbit. This time can range from a few days to a few months. Typically, triplicate samples are taken at pre‐planned times throughout the test. Samples are then analyzed by gas chromatography and mass spectrometry, and the rate of accumulation of pollutants is then extrapolated over time. The analytical values are indexed against 7‐day spacecraft maximum allowable concentrations (SMACs) to provide a prediction of the total toxicity value (T‐value) at the time of first entry. This T‐value and the toxicological effects of specific pollutants that contribute most to the overall toxicity are then used to guide first entry operations. Finally, results are compared to first entry samples collected on orbit to determine the predictive ability of the ground‐based offgas test.

Meyers, Valerie↗

Analysis of Process Gases and Trace Contaminants in Membrane-Aerated Gaseous Effluent Streams.

In membrane-aerated biofilm reactors (MABRs), hollow fibers are used to supply oxygen to the biofilms and bulk fluid. A pressure and concentration gradient between the inner volume of the fibers and the reactor reservoir drives oxygen mass transport across the fibers toward the bulk solution, providing the fiber-adhered biofilm with oxygen. Conversely, bacterial metabolic gases from the bulk liquid, as well as from the biofilm, move opposite to the flow of oxygen, entering the hollow fiber and out of the reactor. Metabolic gases are excellent indicators of biofilm vitality, and can aid in microbial identification. Certain gases can be indicative of system perturbations and control anomalies, or potentially unwanted biological processes occurring within the reactor. In confined environments, such as those found during spaceflight, it is important to understand what compounds are being stripped from the reactor and potentially released into the crew cabin to determine the appropriateness or the requirement for additional mitigation factors. Reactor effluent gas analysis focused on samples provided from Kennedy Space Center's sub-scale MABRs, as well as Johnson Space Center's full-scale MABRs, using infrared spectroscopy and gas chromatography techniques. Process gases, such as carbon dioxide, oxygen, nitrogen, nitrogen dioxide, and nitrous oxide, were quantified to monitor reactor operations. Solid Phase Microextraction (SPME) GC-MS analysis was used to identify trace volatile compounds. Compounds of interest were subsequently quantified. Reactor supply air was examined to establish target compound baseline concentrations. Concentration levels were compared to average ISS concentration values and/or Spacecraft Maximum Allowable Concentration (SMAC) levels where appropriate. Based on a review of to-date results, current trace contaminant control systems (TCCS) currently on board the ISS should be able to handle the added load from bioreactor systems without the need for secondary mitigation.

Gaseous Effluent Streams↗