Search NASA⌕ Search

SEARCH · Search NASA

Results for “SNM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Bayesian Inference of High-density Nuclear Symmetry Energy from Radii of Canonical Neutron Stars

The radius R 1.4 of neutron stars (NSs) with a mass of 1.4 M ⊙ has been extracted consistently in many recent studies in the literature. Using representative R 1.4 data, we infer high-density nuclear symmetry energy E sym (ρ) and the associated nucleon specific energy E 0 (ρ) in symmetric nuclear matter (SNM) within a Bayesian statistical approach using an explicitly isospin-dependent parametric equation of state (EOS) for nucleonic matter. We found the following. (1) The available astrophysical data can already significantly improve our current knowledge about the EOS in the density range of ρ 0 - 2.5ρ 0 . In particular, the symmetry energy at twice the saturation density ρ 0 of nuclear matter is determined to be E sym (2ρ 0 )=${39.2}_{-8.2}^{+12.1}$ MeV at a 68% confidence level. (2) A precise measurement of R 1.4 alone with a 4% 1σ statistical error but no systematic error will not greatly improve the constraints on the EOS of dense neutron-rich nucleonic matter compared to what we extracted from using the available radius data. (3) The R 1.4 radius data and other general conditions, such as the observed NS maximum mass and causality condition, introduce strong correlations for the high-order EOS parameters. Consequently, the high-density behavior of E sym (ρ) inferred depends strongly on how the high-density SNM EOS E 0 (ρ) is parameterized, and vice versa. (4) Finally, the value of the observed maximum NS mass and whether it is used as a sharp cutoff for the minimum maximum mass or through a Gaussian distribution significantly affects the lower boundaries of both E 0 (ρ) and E sym (ρ) only at densities higher than about 2.5ρ 0 .

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian Inference of the Symmetry Energy of Superdense Neutron-rich Matter from Future Radius Measurements of Massive Neutron Stars

In this work, using as references the posterior probability distribution functions of the equation of state (EOS) parameters inferred from the radii of canonical neutron stars (NSs) reported by the LIGO/VIRGO and NICER Collaborations based on their observations of GW170817 and PSR J0030+0451, we investigate how future radius measurements of more massive NSs will improve our current knowledge about the EOS of superdense neutron-rich nuclear matter, especially its symmetry energy term. Within the Bayesian statistical approach using an explicitly isospin-dependent parametric EOS for the core of NSs, we infer the EOS parameters of superdense neutron-rich nuclear matter from three sets of imagined mass–radius correlation data representing typical predictions by various nuclear many-body theories, that is, the radius stays the same, decreases, or increases with increasing NS mass within ±15% between 1.4 and 2.0 M$_\odot$. The corresponding NS average density increases quickly or slowly or slightly decreases as the NS mass increases from 1.4 to 2.0 M$_\odot$. While the EOSs of symmetric nuclear matter (SNM) inferred from the three data sets are approximately the same, the corresponding symmetry energies above about twice the saturation density of nuclear matter are very different, indicating that the radii of massive NSs carry important information about the high-density behavior of nuclear symmetry energy with little influence from the remaining uncertainties of the SNM EOS at suprasaturation densities.

79 ASTRONOMY AND ASTROPHYSICS↗

System, algorithm, and method using short pulse interrogation with neutrons to detect and identify matter

A system, method, and algorithm for detecting and identifying special nuclear material (SNM) (including fissionable material), explosives, or drugs is disclosed. This material detection system relies on active interrogation of material using a short, intense neutron pulse, and characterization of the resulting prompt gamma response in two short time windows, the first concurrent with and the second immediately following the end of the neutron pulse, optionally subject to a total transit delay time of the neutrons from the neutron source to the target and from the target to the gamma detector. A high data rate analysis system implements data stream analysis and statistical correlations of the two short time window gamma responses to rapidly detect or identify SNM, explosives, or drugs. The duration of the neutron pulse is so short that minimal dose results. Various shields help to minimize the background signal falling on the gamma detector to improve sensitivity.

Derzon, Mark S.↗

Statistical Approaches for Pebble Bed Reactor Operations and Safeguards

The design of pebble bed reactors (PBRs) and their method of operation align more closely with statistical approaches used in manufacturing and process control than traditional safeguards statistical approaches. The reason is PBRs will employ a nondestructive assay (NDA) measurement (burnup measurement system [BUMS]) that is part of the fuel handling system supporting discharge decisions in addition to the reactor code which monitor performance. The integration of these two approaches provides the opportunity to monitor reactor performance statistically for both operations and safeguards in ways not achievable using other reactor designs. For light water reactors (LWRs), knowledge about reactor code performance in predicting irradiated special nuclear material (SNM) content historically was only achieved from special measurement campaigns or from fuel reprocessing. Conversely, through statistical comparison of the BUMS with the reactor code-predicted values, PBRs can achieve this in real time. The resulting SNM distribution is an indicator of reactor performance because factors such as transit time and path of the pebble fuel through the reactor determine the plutonium production and uranium depletion. By analyzing the predicted and measured values, opportunities exist to adjust operating parameters, fuel design, and other characteristics to optimize performance and fuel utilization. From a safeguards perspective, this approach also provides the information necessary to validate declared values and evaluate whether the reactor is being operated as expected. This paper outlines statistical approaches for PBRs that can be used to support both operations and safeguards.

Ball, Cory↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In Situ Spectroscopic Monitoring of MSR Molten Salt and Off-Gas Systems

A significant challenge that must be overcome before commercialization of molten salt reactors is tracking special nuclear material (SNM) through the reactor and subsystems such as fuel chemical processing and off-gas systems. In recent years, several approaches have been explored to track SNM, fission products, and corrosion products in these different subsystems. One such approach is to employ laser and optical spectroscopy to measure the atomic and molecular signals of MSR salts. The advantages of these approaches are that they typically are non-intrusive and offer the capability of process monitoring while still providing low uncertainties. At the Idaho National Laboratory, spectroscopy approaches such as laser-induced breakdown spectroscopy (LIBS) and ultraviolet-visible (UV-Vis) spectroscopy have been utilized to investigate molten salts in an aerosol (LiCl, KCl, RbCl2, NdCl3, and PrCl3) and vapor phases (MgCl5, NdCl5, and ZrCl4) with success. Testing to date has yielded qualitative information on all the above species and quantitative data and analytical figures of merit for species in the vapor phases. These findings, including results from ongoing testing, as well as the experimental conditions and potential applications will be presented.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Performance of a dynamic single bubbler in single and two-phase immiscible liquids

Ensuring nonproliferation and safeguards of special nuclear materials (SNM) is a critical aspect of advancing the nuclear fuel cycle. Traditional bubbler systems used to estimate liquid levels and densities in nuclear recycling processes have limitations, particularly in harsh environments where dip-tube corrosion and buildup necessitate frequent maintenance and recalibration. This study explores the Dynamic Single Bubbler (DSB) method, which utilizes a single dip-tube attached to a linear actuator to estimate liquid properties dynamically. This approach is extended to estimate liquid-liquid interfaces in immiscible liquids and employs a linear regression method to reduce uncertainties and improve accuracy. The DSB method achieved density estimate uncertainties of less than 0.5% and surface level estimate uncertainties typically under 0.5%, across various fluids including water, acetone, methanol, mineral oil, glycerol, and aqueous salt solutions. Results indicate that the DSB method provides accurate and robust estimates of liquid density and surface levels with minimal maintenance and without the need for calibration. Additionally, the method's applicability to immiscible liquids and various dip-tube geometries was demonstrated, showing promise for widespread use in nuclear and other industrial applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

Vertically Self-Oriented, Ultrafast 1D ZnO:Li Nanorods as Scintillators for Thermal Neutron Detection

Detection of special nuclear materials (SNMs) is of vital importance in the prevention of nuclear terrorism and to secure states’ national security. Neutron detection is a particularly useful tool to identify SNM, and neutron-sensitive scintillators have many promising properties, such as ease of use, good time resolution, and high detection efficiency. In this work, we develop highly stable, self-oriented, ultrafast 1D ZnO:Li (and codoped with Al, Ga, and In) nanorods (NRs) as thermal neutron-sensitive scintillators. Lithium-6 has high thermal neutron cross section for the (n, α) reaction in ZnO:Li scintillators which have a vertical nano array design greatly increasing the effective surface area and scintillation efficiency. Cost-effective low-temperature (95 °C) hydrothermal growth is used to obtain highly crystalline ZnO:Li nano scintillators by combining nuclear range data and electron transport mechanisms. Among the studies using low-temperature hydrothermal synthesis and a relatively low annealing temperature (≈350 °C) along with optimized NRs (length ≈ 5–8 μm, mean diameter ≈ 700 nm) for thermal neutron detection, this study reports the shortest scintillation decay time (≈ 470 ps) so far to the best of our knowledge. In conclusion, this nano array scintillator combines the advantages of a low-cost growth technique with environmentally friendly and widely available materials.

Ions↗

Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification

Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian inference of nuclear incompressibility from collective flow in mid-central Au+Au collisions at 400–1500 MeV/nucleon

The incompressibility K of symmetric nuclear matter (SNM) is determined through a Bayesian analysis of collective flow data from Au + Au collisions at beam energies $E = 400 -1500$ MeV/nucleon. This analysis utilizes a Gaussian process (GP) emulator applied to the isospin-dependent quantum molecular dynamics (IQMD) model for heavy-ion collisions, both with and without incorporating the momentum dependence of the single-nucleon potentials. Specifically, at the 68% confidence level, using rapidity and transverse velocity dependence of proton elliptic flow data with and without consideration of the momentum dependence, the inferred incompressibility values are $K=188.9^{+2.9}_{-4.5}$ MeV and $256.1^{+8.2}_{-8.7}$ MeV at $E = 400$ MeV/nucleon, respectively. When the transverse momentum dependence of proton-like directed flow data is included, the inferred incompressibility values become $K=222.3^{+9.0}_{-9.9}$ MeV and $K=285.5^{+6.7}_{-7.3}$ MeV, respectively. Furthermore, we found that the value of K derived from observables of proton elliptic flow increases with beam energy. Finally, this indicates that the equation of state (EoS) of nuclear matter hardens at higher densities and temperatures in reactions with higher beam energies.

Bayesian inference↗

Low Mutation Rate and Atypical Mutation Spectrum in Prasinoderma coloniale : Insights From an Early Diverging Green Lineage

Mutations are the ultimate source of genetic diversity on which natural selection and genetic drift act, playing a crucial role in evolution and long-term adaptation. At the molecular level, the spontaneous mutation rate (µ), defined as the number of mutations per base per generation, thus determines the adaptive potential of a species. Through a mutation accumulation experiment, we estimate the mutation rate and spectrum in Prasinoderma coloniale, a phytoplankton species from an early-branching lineage within the Archaeplastida, characterized by an unusually high genomic guanine-cytosine (GC) content (69.8%). We find that P. coloniale has a very low total mutation rate of µ = 2.00 × 10 -10 . The insertion–deletion mutation rate is almost 5 times lesser than the single nucleotide mutation rate with µ ID = 3.40 × 10 -11 and µ SNM = 1.62 × 10 -10 . Prasinoderma coloniale also exhibits an atypical mutational spectrum: While essentially all other eukaryotes show a bias toward GC to AT mutations, no evidence of this AT-bias is observed in P. coloniale. Since cytosine methylation is known to be mutagenic, we hypothesized that this may result from an absence of C-methylation. Surprisingly, we found high levels of C-methylation (14% in 5mC, 25% in 5mCG contexts). Methylated cytosines did not show increased mutation rates compared with unmethylated ones, not supporting the prevailing notion that C-methylation universally leads to higher mutation rates. Overall, P. coloniale combines a GC-rich genome with a low mutation rate and original mutation spectrum, suggesting the almost universal AT-bias may not have been present in the ancestor of the green lineage.

59 BASIC BIOLOGICAL SCIENCES↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of symmetry energy on sound speed and spinodal decomposition in dense neutron-rich matter

Using a meta model for nuclear Equation of State (EOS) with its parameters constrained by astrophysical observations and terrestrial nuclear experiments, we examine effects of nuclear EOS especially its symmetry energy $E$ sym ($ρ$) term on the speed of sound squared $C$ $^2_s$($ρ$) and the critical density ρt where $C$ $^2_s$($ρ_t$) vanishes (indicating the onset of spinodal decomposition) in both dense neutron-rich nucleonic matter relevant for relativistic heavy-ion collisions and the cold $n$ + $p$ + $e$ + $μ$ matter in neutron stars at $β$- equilibrium. Unlike in nucleonic matter with fixed values of the isospin asymmetry $δ$, in neutron stars with a density dependent isospin profile $δ$($ρ$) determined consistently by the $β$-equilibrium and charge neutrality conditions, the $C$ $^2_s$($ρ$) almost always show a peak and then vanishes at $ρ_t$. Furthermore, the latter strongly depends on the high-density behavior of $E$ sym ($ρ$) if the skewness parameter $J$ 0 characterizing the stiffness of high-density symmetric nuclear matter (SNM) EOS is not too far above its currently known most probable value of about -190 MeV inferred from recent Bayesian analyses of neutron star observables. Moreover, in the case of having a super-soft $E$ sym ($ρ$) that is decreasing with increasing density above about twice the saturation density of nuclear matter, the $ρ$ $t$ is significantly lower than the density where the $E$ sym ($ρ$) vanishes (indicating the onset of isospin-separation instability and pure neutron matter formation) in neutron star cores.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗